Rumus Yg Dipakai
Effisiensi 𝑉𝑎𝑐𝑡𝑢𝑎𝑙
Tegangan 𝐸𝑓𝑓 = × 100% V: Tegangan (V) atau (KV)
Aktual Field 𝑉𝑠𝑒𝑡𝑡𝑖𝑛𝑔
Dust ρvs: Dust Resistivity (Ωm2)
𝐴𝑐 × 𝑅𝑚
Resistivity 𝜌𝑣𝑠 = Ac: Collection Area (m2)
𝛿 Rm: Mean Electrical Resistivity (Ω)
Effisiensi ESP Ƞ: Effisiensi
(Deutsch- e: base of natural logarithm
Anderson) −𝑤(𝐴⁄𝑄 ) w: migration velocity (m/s)
𝜂 = 1−𝑒 A: the effective collecting plate area
of the precipitator (m2)
Q: Gas flowrate the precipitator (m3/s)
Kecepatan dp: ukuran diameter partikel (𝜇𝑚)
Migrasi 𝑑𝑝×𝐸𝑜×𝐸𝑝 E: kuat medan listrik (V/m)
W= 4𝜇𝜋 W: kecepatan migrasi (m/s)
𝜇: 𝑣𝑖𝑠𝑘𝑜𝑠𝑖𝑡𝑎𝑠 𝑔𝑎𝑠 𝑏𝑢𝑎𝑛𝑔 (𝑝𝑎𝑠)
Kuat Medan Ko: permittivity (8.85x10-12 F/m)
3×𝑤×𝜇
Listrik E2=2×𝐾𝑜×𝑃𝑎 Pa: p atam
Ket: Ec=Ep=E
Tegangan
untuk kuat V= Exd d: jarak kedua keeping (cm)
medan listrik
Laju aliran Q: laju aliran (m3/s)
Q= AxV A: luas collector plate (m2)
V: velocity (m2/s)
Specific 𝐴 Q: laju aliran (m3/s)
Collection SCA=𝑄
A: luas collector plate (m2)
Area (SCA)
Aspek ratio AR=
𝑝𝑎𝑛𝑗𝑎𝑛𝑔 𝑒𝑓𝑓𝑒𝑘𝑡𝑖𝑓 𝑝𝑒𝑙𝑎𝑡 𝑝𝑒𝑛𝑔𝑢𝑚𝑝𝑢𝑙 (m2)
𝑡𝑖𝑛𝑔𝑔𝑖 𝑒𝑓𝑓𝑒𝑘𝑡𝑖𝑓 𝑝𝑒𝑙𝑎𝑡 𝑝𝑒𝑛𝑔𝑢𝑚𝑝𝑢𝑙 (m2)
Daya korona P= (V1xI1 + V2xI2 + V3xI3 + . . . +
V8xI8)
1. Menghitung Kuat Medan Listrik
Diketahui: V= 56 KV
D= 20 cm = 0.20 m
𝑉
E= 𝐷
56 𝐾𝑉
= 0.20 𝑚 = 280 KV/m
E= Eo = Ep
2. Menghitung Migration Velocity
Diketahui: 𝜇 = 1.8x10-5
Ko= 8.85 x 10-12
−𝑤(𝐴⁄𝑄)
𝜂 = 1−𝑒
−0.026 (2340⁄98075)
= 1−𝑒
= 0.8935 x 100%
= 89.3%
4. Menghitung Specific Collection Area (SCA)
Diketahui: A= 2340m2
Q= 98075 m3/h
𝐴
𝑆𝐶𝐴 =
𝑄
2340 𝑚2
= 3
98075𝑚 ⁄ℎ
2340 𝑚2
= 3
98.075×1000𝑚 ⁄ℎ
23.859 𝑚2
= 3
1000𝑚 ⁄ℎ