DATA SHEET

Cable Management, Distribution & DC Surge Protection


PTTA Product Series
RTP-8706

The deployment of Remote Radio


Head (RRH) architecture poses
unique challenges to the mobile
telecom industry. Raycap’s
innovative and flexible RRH Cable
Management, Distribution and
Protection Solutions provide high
levels of flexibility, availability and
reliability to radio equipment while
mitigating the risk of damage
due to lightning.
Features
 Outdoor tower or rooftop solution
 Power cable management, distribution and protection for up to 3 DC circuits
 Supports up to 3 circuit breakers
 Supports 4 interchangeable options of Overvoltage Protection (OVP) as follows:
- No OVP
- Class II with In=20kA (8/20)
- Class I with Iimp=5kA (10/350)
- Class I with Iimp=12.5kA (10/350)
 Pluggable OVP based on Strikesorb Protective Device (SPD) provides easy field
installation or upgrade without requirement of any tools or rewiring
270 239
 Fully customizable cable ports/connectors
 Various mounting options available
 Flexible design accommodates future site upgrades
 Lightweight aerodynamic design
301
 Non-halogenated, non-flame propagating enclosure rated for indoor and outdoor
installation
 Moisture/pressure equalization vent
159 108
[mm]

Benefits of Strikesorb® Technology


 Strikesorb Surge Protective Devices (SPD) are specifically designed for the Remote
Radio Head (RRH) installation environment and certified for use in DC applications
and at low operating voltages (48V).
 Strikesorb modules offer Class I or Class II protection and are certified by VDE per
the IEC 61643-11 standard as suitable for installation in areas where direct or indirect
lightning exposure is expected.
 Strikesorb incorporates a unique design which enables it to dissipate absorbed
transient/surge energy safely, without excessive heating.
 Strikesorb provides very low voltage protection level as it does not employ spark gaps
or other switching elements offering unique protection levels to the RRH and BBU.
 Strikesorb offers unique maintenance-free protection and provides safe operation
without the need of thermal disconnectors which are the frequent cause of
SPD failures.
 Strikesorb is certified according to IEC 61643-11 for use in-line to power lines
protected with a circuit breaker up to 630A.

Strikesorb is a registered trademark of Raycap


© 2015 Raycap  All rights reserved.
www.raycap.com G00-00-693 160915
Release-3
SPECIFICATIONS Cable Management, Distribution & DC Surge Protection
PTTA Product Series
RTP-8706

RTP-8706
Electrical
OVP Class I 5kA
Surge Protective Device (SPD) per IEC 61643-11 Class I
Surge protection technology MOV
Nominal operating DC voltage 48 VDC
Maximum continuous operating DC voltage [Uc] 75 VDC
Nominal discharge current [In] per IEC 61643-11 for Class II -
Maximum discharge current [Imax] per IEC 61643-11 for Class II -
Impulse discharge current [Iimp] per IEC 61643-11 for Class I 5kA 10/350 μs
Voltage protection level [Up] per IEC 61643-11 300 V
OVP Type Strikesorb 30-V1-HV
Circuit breaker (ordered separately) 16A, Category C, Din Rail
Maximum Rated Load Current 100A
Mechanical Specifications
Incoming / Outgoing power 1 x up to Ø32 mm main power / 3 x Ø13 mm power jumpers
Grounding Cable gland supporting up to 16 mm2
Suppression connection method Compression lug, 2.5 mm2 - 50 mm2
Environmental rating IP67 per EN 60529
Impact resistance IK09 per EN 62262
UV resistant UL 746C (equivalent to ISO 4892-2)
Flammability rating UL94-5V
Box material Hot compression molded fiberglass reinforced polyester (thermoset)
Operating temperature -35° C to +70° C
Enclosure dimension (L × W × H) 239 mm x 301 mm x 108 mm
Lock facility External padlock
Moisture valve Gore-Tex
Standards Compliance & Certifications
Strikesorb modules are compliant to the following Surge Protective Device (SPD) standards:
IEC 61643-11:2011, EN 61643-11:2012, UL 1449 4th Edition, IEEE C62.41:2002, IEEE C62.45:2002, NEMA LS-1 10-year product warranty
Strikesorb modules have the following certifications:
VDE (per IEC 61643-11:2011 and EN 61643-11:2012), UL (per UL 1449 4th Edition)
Products are compliant to the following standards:
EN 60529, EN 62262, UL 746C, UL 94