ERRATA as of March 15, 2012

ACI 301M-10
Specifications for Structural Concrete
1st printing
Reported by ACI Committee 301

1.3.2, Cited publications, page 9, update reference to:


CRSI MSP-2-01 Manual of Standard Practice, 28th edition

Table 4.2.3.3.a, page 24, Eq. (4-3) in Line 3, add prime symbol:
fcr′ = fc + 1.34kss fcr′ = fc′ + 1.34kss

9.2.1.2.e (1), page 37, wrong conversion:


…than 3 mm under 45 kN 0.45 kN concentrated force…

9.2.2.3.b, page 38, point 1) subpoint (e):


Store the mixed grout at the temperature range listed in (a)

Store the mixed grout at the temperature range listed in (b)

9.3.9.1, page 42:


…Strand length protruding beyond wedges after cutting shall not be less than 13 mm.