Download as pdf
Download as pdf
You are on page 1of 4
© Siemens AG 2019 Level Measurement Continuous level measurement Close oe) Ultrasonic controllers overview HydroRanger 200 is an ultrasonic tevel controller for up to shxpumps and provides contol, diferential control, and open ‘channel flow mantorng Benefits + Montore wet wells, weirs and tlumes + Digital communications with bull-n Modbus RTU via RS 485 ‘+ Compatible with SmartLinx system and SIMATIC PDM configuration software Single or dual point level monitoring 6 relay (standard), 1 or 3 relay (optional) ‘Avo False-Echo Suppression fo fixed obstruction avoidance Ani-groase ringtide mark buildup Ditferentia! ampiler transcever for common mode noise rejection and improved signal-to-noise ratio. ‘+ Wall and panel mounting options ‘Wapptication For water authorities, municipal water, and wastewater plants, HydroRangor 200 is an economical, low-mainlenance solution Gelvering conta! efficiency and productivty needed to meet loday’s exacting standards. ILoffors single point monitoring with all models, and optional dual-point monitoring witn é relay model. As well, ichas digital communications with buil-n Mocs RTU via FS 485, ‘Tho stanclard 6 relay HyaraRanger 200 wil moniter open channel flow and features more advanced relay alarming and Pump control functions as well as volume conversion. It's Compatible with SIMATIC POM, allowing for PC configuration {and sotuo. Sonic Inteligence advanced echo-processing sollware provides increased reading reliably. The optional 1 or 3 relay mode's provide accurate love! measurement functions only; these two mode's do not provide open channel iow, ‘lferential lovel measurement ar volume conversion functions. HydroRanger 200 uses proven continuous ultrasonic echo rangng technology to mantor water and wastewater of any Cconsisiency up to +S m (60 ft) in depth. Achievable resolution is07 % wih accuracy 1000.25 % of range. Unlixe comacing Gevices, HycroRanger 200 's immune to problems caused By Suspended solds, harsh cotrosives, grease or sit inthe etfuert, redueing downtime. ‘+ Koy Applications: wot wolls, fumos/wairs, bar screen control PIT] sirens tot - 2014 © Siemens AG 2019 Continuous level measurement Level Measurement Ultrasonic controllers nacre) Wrechnical specifications itode of eperaton Design Measaing nee trata ve mearurrant Wight Tit aut 137kg gor) Messung rn 0a... 18m(..80 vee Maids? Sooo {Panel mau 130K9 831) Messing pains toe Matra orcosue) Pabyeatbonate inp Degen otpotecton erie) = aunt IResrype xn ax si ir 207 fovea fmatwrate sve, soamabe* Pane mount IPberype aNEWAS (Sry moc ewe Discrete 10. S0VDG.ewishngiev! ——sTarsaueer and mc signl coe copper condita ed toga ozasvoe Shot Wns O88 togea't= 10 -S0¥0e AWG} eecen# Year NoC3 ma feuivaer ie ecapabe Saar ‘ht soparaton between 3887 (1200 EoroMax vaascor Mite tiredlcr and vans vasni arscueer Conall tanssucee splays and conta TOGA TS ely CE Trak de LOD wk backing wiStinor andes Pregrarmne Progranming us andr Folays"? + Model with 1 relay “Motil wih 3 oiays#! “Mosel wih 6 ays mA ouiout + Max. oad + Fosoluion Recuracy Error in measurersent Revolson ‘Temperature compensation ated operating condlvons Installation conatone Location + instalation category + Pollan degree ‘mion condone + Ambient lemperature (eneisure) Rating §A.al250V AC, ranaaucive 1SPSTFerm & 2 SPST Form Alt SPDT Form 4 SPST Form Az SPDT Form ©. 20mAor4...20mA, 7500. soared DA % of ange 0.25 ve af range or 6 mm (0124 nen), wnienover's reat 01% ef measuring range ot 2mm (Q.08 neh), whicnover Is reste” $50. 180°C (58... +902) * integral temperature Sensor in rau ‘+ Exlorral TS3 lemperatro ‘senso (optanal), + Programmable ea temperature values Indooe outdoor " 20. 450°C (4. +122) proaranmer or via PC mith Shaatic Pow sarware Bowersappy Aceon too, gs0vac 215%, eo teeateati oe verion 12 s0v00 (20) Geriteaes and poe OCTET {Eee topir of Sipse Lase ope ara TA cee rE ea Teens Gosticb 3 a0 as See cmupstanae, Sas Susann, MSHS Cit approved fo Ssonchowal ak ‘Communieation TRS 252 wth Modbus RIV" ASCII ia PU-1t comectar “+S 285 wih Modbus RTU ASCII viatermina biooks + Opienat Smarinx cares fr SROPBUS DP "DaveeNet “allen: Jey Remote UO ‘lola exter ust equipment thal is ina stale alo under ‘ated aumams othe aye Tie models eve! canta ony no. open enamel oe Progtan range dened as be empl isan transducer pus any tange tension aximam power consump it sted eno peviormance avaiable upon reques toe ace othe Semenerior 20% PET Level Measurement Continuous level measurement © Siemens AG 2019 Ultrasonic controllers eee [Section and Orang ata ‘ion [lf Seeiion and Ordering ata Dre cade Siemens HyaroRanger 200 Farther dealgne Reeser ette upto sapumps:na Preuss ast 2G Ae No ard spec Orr Ploweles sonal, difererial convo’ ana open harnel flaw maniiveng. Tre | yareRanger 200 is ‘dao avalaule ara evel mescureme" ontoler nly. Select option fom numberof moasuremont points options below Mounting Wai mount, standard encosre Wal ert ens, 420 cable ands included Panel mount" Bower supply 12.30 0e ‘Number of measurement paints Single point mode, 6 relays Dual acint made, relays Single point model, eve ony 1 rela Single woint model. love ony 3 relays? ‘Communication (SmartLinx) \inout module Sivartnx AlenBracley Rerrote YO module ‘SmarLinx PROFIBUS DP module Smantinx DeviceNet module See Smart.in produc page 41889 for move formation ‘General Puppase CE, FM, CSA ye UL sted, C-TCK SA Class | Die 2, Groupe ABC, and D; Class IL DW 2, Groups Fane & Clas for wallmount appcations ony) 1 pvalable wh agproval option 1 ony 2 ths mace is lve contl ne open channel low, torent eve orvolune carvers usetons odes Shaness see ag 8x50 0mm 71x 187 HTD) Measuing-pomn aumber/denticatan {ras 27 characters specty plan xt ‘Operating Insvuctons English Frone’ Gorman Nef: The Operating Instructions shouts be devel s6 separate lem on ne det ‘is deviee fs shpved wit the Semmens Mtns ‘manual OVD contaning te ATEX Quick Stat arc ‘Boerating Instructions Rory ‘Other Operating instructions Smaninx lenBracley Remote VO, Erghsn SSmarnx PROFIBUS DP. English Smantnx PROFIBUS DP, Germa ‘Smannx PROFIBUS DP. French ‘SmarLinx DevieNel. Engin Note The appropiate Smt ix Operating Instuctrssaise over as &fenurate ie nthe order ‘Tecessories Handreld prograrme ag, elailoss ste), 1245 mm (0.47 x 1.77 inh), cone te lne, stable for enclose Sursheld kt, 304 stares stoe! SITPANS PO100 Remote display see Chapter 7 SITRANS 0200 Remote sisplay see Chapter 7 SITRANS D500 wad, datalogging, alarming, fetheret, and moder support fr fstrumertation - Seachapier Spare parts Power Sup Boars (00, Powe: Supply Board (12 Display Board 220 AC) ‘savoe) DIET] sirens 101-2014 @ Sieens AG 2018 Level Measurement Continuous level measurement — Ultrasonic controllers nacre) Hbimensional drawings ‘Hischematies be Seo rots 1 maestro) ae ve GHEE wal | (fen pemiaa] { py ae 3 I] a ~~ Ss S| 1 gg | Sar — a Ee o |= ofr | 1S | g Zt SHIELD KO Dl 1A way sam +] (© ull locaton tar —— , usr e, ja" ones 3) @ con enzarons ened By etsomen Sg L_+ je Slmere rons ay Mouning hole — Q| Relay a] el Sicha Ba, graeme 6) S$ \a mS 2 aa oc omy , I or Q ja ; oe] |S val S| [a ose fae | 1 tay S| | ees Er] fs Ss con [SO a cre cols D Gl |F — elayssnowninreiesses |_# || (D {tesa cope or le er peep SniftotyRorecum senna ae 2 Vy oteeyamcorpnrar tense wt FyteRanger 200. ders mm neh 2. Comet cite ita wo fang 200 il cree ‘Eom And arma ant ornate ae ee vee es 4. Keop sxpoted conductors on sided cblos ae short as possible toeduce nies on ne ne caused by say Vansmissons aranse Pike HystoRtanger 00 connections Siemenerior 20x EES)

You might also like