Professional Documents
Culture Documents
Hot Water Pumps Dab R PDF
Hot Water Pumps Dab R PDF
Hot Water Pumps Dab R PDF
TECHNICAL DATA
Operating range: from 1 to 12 m3/h with head up to 11 metres.
Pumped liquid temperature range: from -10°C to +110°C.
Pumped liquid: clean, free from solids and mineral oils, not viscous,
chemically neutral, close to the characteristics of water (max 30% glycol).
Maximum working pressure: 10 bar (1000 kPa).
Protection level: IP 44
A
Insulation class: F
Cable grommet: PG 11
Installation: with motor axis horizontal.
Standard voltage input: single-phase 230 V / 50 Hz
three-phase 400 V/ 50 Hz
This product complies with European standard EN 60335-2-51
D
APPLICATIONS
CONSTRUCTION FEATURES
Pump body in cast iron and motor in die cast aluminium.
Impeller in technopolymer, motor shaft in hardened stainless steel held in graphite bearings lubricated by the pumping medium.
Pump body with threaded ports.
Rotor protective jacket, stator jacket, and closing flange in stainless steel.
The two-pole asynchronous wet rotor motor features three-speed operation.
Integral thermal probe in single-phase version.
119
A/B/D
WET ROTOR CIRCULATORS
MATERIALS
N. PARTS MATERIALS
7B ROTOR –
8 STATOR –
9 CAPACITOR –
4
10 MOTOR CASING DIE CAST ALUMINIUM 127
M = single-phase motor
T = three-phase motor
120
A/B/D
WET ROTOR CIRCULATORS
PERFORMANCE RANGE
The performance curves are based on kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
150
15 50
40
100
10
90
9 30
BMH
80
70
7
60
6 20
50
5
40
4
DMH
30 DPH
3 10
VA - VB - VD
20 2
VS 5
10 1
0,1 0,2 0,3 0,4 0,5 0,8 1 2 3 4 5 6 7 8 10 20 30 40 50 60 80 100 200 Q m3/h
0,1 0,5 1 2 3 4 5 10 20 30 Q l/s
2 3 4 5 10 20 30 40 50 100 200 300 400 500 1000 2000 3000 Q l/min
121
A/B/D
WET ROTOR CIRCULATORS
A 56/180 XT H
6,4 6,3 6,2 6,1 6 5,9 5,7 4,4
(m)
A 80/180 M 8,25 8 7,6 7,4 7,2 6,9 6,3 3,8
B 56/250.40 T H
6,4 6,3 6,2 6,1 6 5,9 5,7 4,4
(m)
B 80/250.40 M 8,25 8 7,6 7,4 7,2 6,9 6,3 3,8
D 56/250.40 T H
5,9 5,85 5,8 5,6 5,5 5,2 4,6 2,9
(m)
D 80/250.40 M 8,25 8 7,6 7,4 7,2 6,9 6,3 3,8
122
A 50/180 M - HEATING, AIR CONDITIONING
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
H
H1 H2
L
L1 L2
B1
B
B2
A 50/180 M 180 90 90 173 34 139 143 52 92 1“ 1/2 206 170 180 0,066 5
50 5
16
40 4
12
L 30 3
L1 L2
8
20 2
B1 4
10 1
B 0 0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q m3/h
B2 0 0,5 1 1,5 2 2,5 3 Q l/s
0 20 40 60 80 100 120 140 160 180 Q l/min
A 50/180 XM 180 90 90 173 34 139 143 52 92 2” G 206 170 180 0,066 5,3
123
A 50/180 T - HEATING, AIR CONDITIONING
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
0 5 10 15 20 25 30 35 Q USgpm
H
0 5 10 15 20 25 30 Q IMPgpm
H1 H2
0 0,2 0,4 0,6 0,8 1 V m/s Ø 1" 1/2
P H H
kPa m
400 V~ 50 Hz ft
60 6 20
50 5
16
40 4
12
L 30 3
L1 L2 8
20 2
B1 4
10 1
0 0 0
B 0 1 2 3 4 5 6 7 8 Q m3/h
B2 0 0,5 1 1,5 2 Q l/s
A 50/180 T 180 90 90 173 34 139 143 52 92 1“ 1/2 206 170 180 0,066 5,3
0 5 10 15 20 25 30 35 40 45 Q USgpm
H
H1 H2 0 5 10 15 20 25 30 35 40 Q IMPgpm
0 0,5 1 1,5 2 V m/s Ø 1"
P H H
kPa m
400 V~ 50 Hz ft
60 6 20
50 5
16
40 4
12
L 30 3
L1 L2
8
20 2
B1 4
10 1
0 0 0
B 0 1 2 3 4 5 6 7 8 9 10 11 Q m3/h
B2 0 0,5 1 1,5 2 2,5 3 Q l/s
0 20 40 60 80 100 120 140 160 180 Q l/min
A 50/180 XT 180 90 90 173 34 139 143 52 92 2” G 206 170 180 0,066 5,2
124
A 56/180 M - HEATING, AIR CONDITIONING
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
H
H1 H2
L
L1 L2
B1
B
B2
A 56/180 M 180 90 90 173 34 139 143 52 92 1“ 1/2 206 170 180 0,066 5,3
0 10 20 30 40 50 60 Q USgpm
H
H1 H2 0 10 20 30 40 50 Q IMPgpm
0 0,5 1 1,5 2 2,5 3 V m/s Ø 1"
P H H
kPa m 230 V~ 50 Hz ft
7
60 6 20
5 16
40 4
L 12
L1 L2 3
8
20 2
B1 4
1
0 0 0
B 0 2 4 6 8 10 12 14 Q m3/h
B2 0 1 2 3 4 Q l/s
0 50 100 150 200 250 Q l/min
A 56/180 XM 180 90 90 173 34 139 143 52 92 2” G 206 170 180 0,066 5,3
125
A 56/180 T - HEATING, AIR CONDITIONING
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
0 10 20 30 40 Q USgpm
H
H1 H2 0 10 20 30 40 Q IMPgpm
0 0,2 0,4 0,6 0,8 1 1,2 1,4 V m/s Ø 1"1/2
P H H
kPa m 400 V~ 50 Hz ft
7
60 6 20
5 16
40 4
12
L
L1 L2 3
8
20 2
B1 4
1
0 0 0
B 0 2 4 6 8 10 Q m3/h
B2 0 1 2 3 Q l/s
0 50 100 150 Q l/min
A 56/180 T 180 90 90 173 34 139 143 52 92 1“ 1/2 206 170 180 0,066 5,2
0 10 20 30 40 50 60 Q USgpm
H
H1 H2 0 10 20 30 40 50 Q IMPgpm
0 0,5 1 1,5 2 2,5 3 V m/s Ø 1"
P H H
kPa m 400 V~ 50 Hz ft
7
60 6 20
5 16
40 4
12
L
L1 L2 3
8
20 2
B1 4
1
0 0 0
B 0 2 4 6 8 10 12 14 Q m3/h
B2 0 1 2 3 4 Q l/s
0 50 100 150 200 250 Q l/min
A 56/180 XT 180 90 90 173 34 139 143 52 92 2“ G 206 170 180 0,066 5,3
126
A 80/180 M - HEATING, AIR CONDITIONING
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
0 5 10 15 20 25 30 35 40 Q USgpm
H
H1 H2 0 5 10 15 20 25 30 Q IMPgpm
0 0,2 0,4 0,6 0,8 1 1,2 V m/s Ø 1"1/2
P H H
kPa m 230 V~ 50 Hz ft
8
24
70 7
60 6 20
50 5 16
L 40 4
12
L1 L2 30 3
8
20 2
B1
4
10 1
0 0 0
B 0 1 2 3 4 5 6 7 8 9 Q m3/h
B2 0 0,5 1 1,5 2 2,5 Q l/s
A 80/180 M 180 90 90 173 34 139 143 52 92 1“ 1/2 206 170 180 0,066 5,3
H 0 5 10 15 20 25 30 35 40 45 Q USgpm
H1 H2 0 5 10 15 20 25 30 35 40 Q IMPgpm
0 0,5 1 1,5 2 V m/s Ø 1"
P H H
kPa m 230 V~ 50 Hz ft
8
24
70 7
60 6 20
50 5 16
L 40 4
12
L1 L2
30 3
8
20 2
B1
4
10 1
0 0 0
B 0 1 2 3 4 5 6 7 8 9 10 11 Q m3/h
B2 0 0,5 1 1,5 2 2,5 3 Q l/s
0 20 40 60 80 100 120 140 160 180 Q l/min
A 80/180 XM 180 90 90 173 34 139 143 52 92 2” G 206 170 180 0,066 5,2
127
A 80/180 T - HEATING, AIR CONDITIONING
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
0 5 10 15 20 25 30 35 40 Q USgpm
H
H1 H2 0 5 10 15 20 25 30 Q IMPgpm
0 0,2 0,4 0,6 0,8 1 1,2 V m/s Ø 1"1/2
P H H
kPa m 400 V~ 50 Hz ft
8
24
70 7
60 6 20
50 5 16
L 40 4
12
L1 L2 30 3
8
20 2
B1
4
10 1
0 0 0
B 0 1 2 3 4 5 6 7 8 9 Q m3/h
B2 0 0,5 1 1,5 2 2,5 Q l/s
A 80/180 T 180 90 90 173 34 139 143 52 92 1“ 1/2 206 170 180 0,066 5,3
0 5 10 15 20 25 30 35 40 45 Q USgpm
H
H1 H2 0 5 10 15 20 25 30 35 40 Q IMPgpm
0 0,5 1 1,5 2 V m/s Ø 1"
P H H
kPa m 400 V~ 50 Hz ft
8
24
70 7
60 6 20
50 5 16
L 40 4
12
L1 L2
30 3
8
20 2
B1
4
10 1
0 0 0
B 0 1 2 3 4 5 6 7 8 9 10 11 Q m3/h
B2 0 0,5 1 1,5 2 2,5 3 Q l/s
0 20 40 60 80 100 120 140 160 180 Q l/min
A 80/180 XT 180 90 90 173 34 139 143 52 92 2” G 206 170 180 0,066 5,3
128
A 110/180 M - HEATING, AIR CONDITIONING
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
H 0 10 20 30 40 50 Q USgpm
H1 H2 0 10 20 30 40 Q IMPgpm
P H0 0,4 0,8 1,2 1,6 V m/s Ø 1"1/2
kPa m H
11 230 V~ 50 Hz ft
100 10
90 30
9
80 8 25
70 7
L 60 6 20
L1 L2 50 5
15
40 4
B1 30 3 10
20 2
5
10 1
B 0 0
0 2 4 6 8 10 12 Q m3/h
0
B2
0 0,5 1 1,5 2 2,5 3 3,5 Q l/s
0 20 40 60 80 100 120 140 160 180 200 220 Q l/min
A 110/180 M 180 93 87 229 42 186 167 70 97 1“ 1/2 G 237 200 272 0,066 5,3
H 0 10 20 30 40 50 Q USgpm
H1 H2 0 10 20 30 40 Q IMPgpm
P H0 0,4 0,8 1,2 1,6 V m/s Ø 1"1/2
kPa m H
11 230 V~ 50 Hz ft
100 10
90 30
9
80 8 25
70 7
L 60 20
6
L1 L2 50 5
15
40 4
B1 30 10
3
20 2
5
10 1
B 0 0 0
0 2 4 6 8 10 12 Q m3/h
B2
0 0,5 1 1,5 2 2,5 3 3,5 Q l/s
0 20 40 60 80 100 120 140 160 180 200 220 Q l/min
A 110/180 XM 180 93 87 229 42 186 167 70 97 2” G 237 200 272 0,066 5,3
129
A 110/180 T - HEATING, AIR CONDITIONING
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
H
H1 H2
400 V~ 50 Hz
L
L1 L2
B1
B
B2
A 110/180 T 180 93 87 229 186 42 163 70 93 1 1/2” G 237 200 272 0,066 5,2
H
H1 H2
400 V~ 50 Hz
L
L1 L2
B1
B
B2
A 110/180 XT 180 93 87 229 186 42 163 70 93 2” G 237 200 272 0,066 5,2
130
B 50/250.40 M - HEATING, AIR CONDITIONING
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
0 5 10 15 20 25 30 35 40 45 Q USgpm
H1 H2 D 0 5 10 15 20 25 30 35 40 Q IMPgpm
0 0,5 1 1,5 2 V m/s Ø 1"
P H H
kPa m
230 V~ 50 Hz ft
60 6 20
50 5
16
40 4
12
30 3
8
D1 20 2
L D2
L1 L2 D4 4
10 1
B1 0 0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q m3/h
0 0,5 1 1,5 2 2,5 3 Q l/s
B
B2 0 20 40 60 80 100 120 140 160 180 Q l/min
B 50/250.40 M 250 125 125 204 65 139 150 110 100 80 40 167 75 92 DN40/PN10 302 202 283 0,013 9,1
0 5 10 15 20 25 30 35 40 45 Q USgpm
H1 H2 D 0 5 10 15 20 25 30 35 40 Q IMPgpm
0 0,5 1 1,5 2 V m/s Ø 1"
P H H
kPa m
400 V~ 50 Hz ft
60 6 20
50 5
16
40 4
12
30 3
D1 8
L D2 20 2
L1 L2 D4
4
10 1
B1
0 0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q m3/h
B 0 0,5 1 1,5 2 2,5 3 Q l/s
B 50/250.40 T 250 125 125 204 65 139 150 110 100 80 40 167 75 92 DN40/PN10 302 202 283 0,013 9,3
131
B 56/250.40 M - HEATING, AIR CONDITIONING
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
0 10 20 30 40 50 60 Q USgpm
H1 H2 D 0 10 20 30 40 50 Q IMPgpm
0 0,5 1 1,5 2 2,5 3 V m/s Ø 1"
P H H
kPa m 230 V~ 50 Hz ft
7
60 6 20
5 16
40 4
12
3
D1 8
L D2 20 2
L1 L2 D4
4
1
B1 0 0 0
0 2 4 6 8 10 12 14 Q m3/h
0 1 2 3 4 Q l/s
B
B2 0 50 100 150 200 250 Q l/min
B 56/250.40 M 250 125 125 204 65 139 150 110 100 80 40 167 75 92 DN40/PN10 302 202 283 0,013 9,3
0 10 20 30 40 50 60 Q USgpm
H1 H2 D 0 10 20 30 40 50 Q IMPgpm
0 0,5 1 1,5 2 2,5 3 V m/s Ø 1"
P H H
kPa m 400 V~ 50 Hz ft
7
60 6 20
5 16
40 4
12
3
D1 8
L D2 20 2
L1 L2 D4
4
1
B1 0 0 0
0 2 4 6 8 10 12 14 Q m3/h
0 1 2 3 4 Q l/s
B
B2 0 50 100 150 200 250 Q l/min
B 56/250.40 T 250 125 125 204 65 139 150 110 100 80 40 167 75 92 DN40/PN10 302 202 283 0,013 9,2
132
B 80/250.40 M - HEATING, AIR CONDITIONING
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
0 5 10 15 20 25 30 35 40 45 Q USgpm
H1 H2 D 0 5 10 15 20 25 30 35 40 Q IMPgpm
0 0,5 1 1,5 2 V m/s Ø 1"
P H H
kPa m 230 V~ 50 Hz ft
8
24
70 7
60 6 20
50 5 16
40 4
12
30
D1 3
D2 8
L 20 2
L1 L2 D4
4
10 1
B1 0 0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q m3/h
0 0,5 1 1,5 2 2,5 3 Q l/s
B
B2 0 20 40 60 80 100 120 140 160 180 Q l/min
B 80/250.40 M 250 125 125 204 65 139 150 110 100 80 40 167 75 92 DN40/PN10 302 202 283 0,013 9,3
0 5 10 15 20 25 30 35 40 45 Q USgpm
H1 H2 D 0 5 10 15 20 25 30 35 40 Q IMPgpm
0 0,5 1 1,5 2 V m/s Ø 1"
P H H
kPa m 400 V~ 50 Hz ft
8
24
70 7
60 6 20
50 5 16
40 4
12
D1 30 3
L D2 8
L1 L2 D4 20 2
4
10 1
B1
0 0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q m3/h
B 0 0,5 1 1,5 2 2,5 3 Q l/s
B 80/250.40 T 250 125 125 204 65 139 150 110 100 80 40 167 75 92 DN40/PN10 302 202 283 0,013 9,3
133
B 110/250.40 M - HEATING, AIR CONDITIONING
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
H
H2 H2
H1 H1
D D3D D3
H
0 10 20 30 40 50 Q USgpm
0 10 20 30 40 Q IMPgpm
P H0 0,4 0,8 1,2 1,6 V m/s Ø 1"1/2
kPa m H
11 230 V~ 50 Hz ft
100 10
90 30
9
80 8 25
70 7
60 6 20
50 5
15
D1 40 4
D2
L
D1
D4
L1
L2
30 3 10
D2 20 2
D4 5
10 1
B1 B1
0 0 0
0 2 4 6 8 10 12 Q m3/h
0 0,5 1 1,5 2 2,5 3 3,5 Q l/s
B
B2 B2
MODEL L L1 L2 B B1 B2 D D1 D2 D3 D4 H H1 H2 F
L1 L1
L2 L2
D1 L B H m3 kg
L
D2
D4
B 110/250.40 M 250 125 125 256 70 186 150 110 100 80 40 172 75 97 DN40/PN10 302 202 283 0,013 9,2
B1
B
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
H
H2 H2
H1 H1
D D3D D3
H
400 V~ 50 Hz
D1
D2
L
D1
D4
L1
L2
D2
D4
B1 B1
B
B2 B2
B
134
D 50/250.40 M - HEATING, AIR CONDITIONING
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
0 5 10 15 20 25 30 35 40 45 Q USgpm
H
H1 H2 0 5 10 15 20 25 30 35 40 Q IMPgpm
D 0 0,5 1 1,5 2 V m/s Ø 1"
D3 P H H
kPa m
230 V~ 50 Hz ft
60 6 20
L2
50 5
L 16
40 4
L1
12
30 3
D1 8
D2 20 2
D4
4
10 1
B1
0 0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q m3/h
B 0 0,5 1 1,5 2 2,5 3 Q l/s
B2
0 20 40 60 80 100 120 140 160 180 Q l/min
D 50/250.40 M 250 125 125 204 65 139 150 110 100 80 40 247 122 126 DN40/PN10 335 298 283 0,018 15,3
0 5 10 15 20 25 30 35 40 45 Q USgpm
H
0 5 10 15 20 25 30 35 40 Q IMPgpm
H1 H2
D 0 0,5 1 1,5 2 V m/s Ø 1"
D3 P H H
kPa m
400 V~ 50 Hz ft
60 6 20
L2
50 5
16
L
40 4
L1 12
30 3
8
D1 20 2
D2
D4 4
10 1
B1
0 0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q m3/h
B 0 0,5 1 1,5 2 2,5 3 Q l/s
B2 0 20 40 60 80 100 120 140 160 180 Q l/min
D 50/250.40 T 250 125 125 204 65 139 150 110 100 80 40 247 122 126 DN40/PN10 335 298 283 0,018 15,8
135
D 56/250.40 M - HEATING, AIR CONDITIONING
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
H 0 10 20 30 40 50 60 Q USgpm
H1 H2 0 10 20 30 40 50 Q IMPgpm
D
D3 H
0 0,5 1 1,5 2 2,5 3 V m/s Ø 1"
P H
kPa m 230 V~ 50 Hz ft
7
L2
60 6 20
L
5 16
L1
40 4
12
3
D1 8
D2 20 2
D4
4
1
B1
0 0 0
0 2 4 6 8 10 12 14 Q m3/h
B 0 1 2 3 4 Q l/s
B2 0 50 100 150 200 250 Q l/min
D 56/250.40 M 250 125 125 204 65 139 150 110 100 80 40 247 122 126 DN40/PN10 355 298 283 0,018 15,8
H 0 10 20 30 40 50 60 Q USgpm
H1 H2 0 10 20 30 40 50 Q IMPgpm
D
D3 0 0,5 1 1,5 2 2,5 3 V m/s Ø 1"
P H H
kPa m 400 V~ 50 Hz ft
7
L2
60 6 20
L
5 16
L1
40 4
12
3
D1 8
D2 20 2
D4
4
1
B1 0 0 0
0 2 4 6 8 10 12 14 Q m3/h
B 0 1 2 3 4 Q l/s
B2 0 50 100 150 200 250 Q l/min
D 56/250.40 T 250 125 125 204 65 139 150 110 100 80 40 247 122 126 DN40/PN10 335 298 283 0,018 15,4
136
D 80/250.40 M - HEATING, AIR CONDITIONING
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
H 0 5 10 15 20 25 30 35 40 45 Q USgpm
H1 H2 0 5 10 15 20 25 30 35 40 Q IMPgpm
D
D3 P H
0 0,5 1 1,5 2 V m/s Ø 1"
H
kPa m 230 V~ 50 Hz ft
8
L2 70 7
24
L 60 6 20
L1 50 5 16
40 4
12
D1 30 3
D2 8
20 2
D4
4
10 1
B1 0 0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q m3/h
B 0 0,5 1 1,5 2 2,5 3 Q l/s
B2 0 20 40 60 80 100 120 140 160 180 Q l/min
D 80/250.40 M 250 125 125 204 65 139 150 110 100 80 40 247 122 126 DN40/PN10 355 298 283 0,018 15,8
H 0 5 10 15 20 25 30 35 40 45 Q USgpm
H1 H2 0 5 10 15 20 25 30 35 40 Q IMPgpm
D
D3 0 0,5 1 1,5 2 V m/s Ø 1"
P H H
kPa m 400 V~ 50 Hz ft
8
L2 70 7
24
L 60 6 20
L1 50 5 16
40 4
12
30 3
D1
D2 8
20 2
D4
4
10 1
B1 0 0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q m3/h
B 0 0,5 1 1,5 2 2,5 3 Q l/s
B2 0 20 40 60 80 100 120 140 160 180 Q l/min
D 80/250.40 T 250 125 125 204 65 139 150 110 100 80 40 247 122 126 DN40/PN10 335 298 283 0,018 15,8
137
D 110/250.40 M - HEATING, AIR CONDITIONING
Pumped liquid temperature range: from -10 °C to +110 °C - Maximum operating pressure: 10 bar (1000 kPa)
H2
H1
0 10 20 30 40 50 Q USgpm
D D3 D D3
H
0 10 20 30 40 Q IMPgpm
H2
H1
D D3 V m/s Ø 1"1/2
P H0 0,4 0,8 1,2 1,6
kPa m H
11 230 V~ 50 Hz ft
L2 H2 100 10
90 30
9
L H
D1
D2
D4
80 8 25
L1 H1 70 7
60 6 20
50 5 B1 B2 15
D1 40 4 B
D2 10
30
D4
D1
3
D2 20 2
D4 10 1
5
B1
0 0 0
0 2 4 6 8 10 12
B1
Q m3/h
B
MODEL L L1 L2 B B1 B2 D D1 D2 D3 D4 H H1 H2 F
L2
L1
L B H m3 kg
L
L2
L1
D 110/250.40 M 250 122 128 231 70 161 150 110 100 80 40 302 149 154 DN40/PN10 355 298 283 0,018 16
H2
H1
D D3 D D3
H
H2
H1
D D3
400 V~ 50 Hz
L2 H2
L H
D1
D2
D4
L1 H1
B1 B2
D1 B
D2
D4
D1
D2
D4
B1 B1
B
B2
B
B2
D 110/250.40 T 250 122 128 231 70 161 150 110 100 80 40 302 149 154 DN40/PN10 355 298 283 0,018 15,8
138