SERVICE DATA
12.5 V or higher
Auxiliary battery
is OK
11.0 to 12.5 V
Auxiliary battery Positive (+) terminal -
20°C (68°F), Power switch off Recharge auxiliary
voltage Negative (-) terminal
battery
Below 11.0 V
Replace auxiliary
battery
S46B24R 4 to 5 A
12.5 V or higher
Auxiliary battery
is OK
Recharge auxiliary 11.0 to 12.5 V
battery Positive (+) terminal -
20°C (68°F), Power switch off Recharge auxiliary
Negative (-) terminal
battery
Below 11.5 V
Replace auxiliary
battery
Fuse Standard resistance Below 1 ohms
Current flowing from
0 A or less
auxiliary battery
(no current from
Auxiliary battery
Power switch on (READY) (The headlight position switch auxiliary battery)
DC/ DC converter positive cable
and blower motor switch are in the HI position, and the rear
function Auxiliary battery window defogger is turned on.)
voltage
13 to 15 V
Positive (+) terminal -
Negative (-) terminal
3.00 to 3.73 kohms
at 10°C (50°F)
2.45 to 2.88 kohms
at 15°C (59°F)
1.95 to 2.30 kohms
at 20°C (68°F)
1.60 to 1.80 kohms
at 25°C (77°F)
1.28 to 1.47 kohms
Auxiliary battery at 30°C (86°F)
Standard Resistance 1-2
thermometer sensor 1.00 to 1.22 kohms
at 35°C (95°F)
0.80 to 1.00 kohms
at 40°C (104°F)
0.65 to 0.85 kohms
at 45°C (113°F)
0.50 to 0.70 kohms
at 50°C (122°F)
0.44 to 0.60 kohms
at 55°C (131°F)
0.36 to 0.50 kohms
at 60°C (140°F)
TORQUE SPECIFICATIONS
TORQUE SPECIFICATIONS
TORQUE SPECIFICATIONS
TORQUE SPECIFICATIONS