STORM WATER MUST FLOW WHERE THE

ALL WORK TO COMPLY WITH SABS 0400 GARDEN DOORS/ GATES SHOULD BOUNDARY WALLS TO MATCH HOUSE & TO BE NOTES
DIRECTION OF THE SLOPE FLOWS MAINTANANCE FREE ON NEIGHBOURS SIDE
AND NATIONAL BUILDING REGULATIONS HAVE SELF CLOSING ARM ROOF: ALUMINIUM CORRUGATED CHROMADEK

portal frame for the roof fixed to wall 114x38mm s.a pine wall plate
*SMALL DSTV DISH WILL BE USED & POSITION APPROVED STREET BOUNDARY MUST BE COMPLETELY OPEN WITH NO
WASHING LINES /GAS INSTALLATIONS/ embedded at least 300mm into brickwork with connecting devices according to
BY RESIDENTIAL MANAGER. ALL WINDOW & DOOR FRAMES TO BE BOUNDARY WALL / FENCE WITHIN THE 5m RESTRICTED ZONE
REFUSE AREAS TO BE SCREENED OFF NOT table l2, schedule 1, of sabs 0400
*SOLAR HEATING PANELS & AIR CONDITIONING UNITS ALUMINIUM BRONZE ANODISED TO BE VISIBLE FROM STREET/ PUBLIC AREAS all web members to be minimum 38x114mm grade 4 with equal bays smaller
POSITION TO BE APPROVED BY RESIDENTIAL MANAGER than 1500mm. approaved bracing must prevent buckling and keep trusses upright
ALUMINIUM CORRUGATED CHROMADEK valley and hip rafters to be grade 6 50x228 sa pine
ALUMINIUM CORRUGATED CHROMADEK
laminated timber to comply with sabs 876
ALUMINIUM CORRUGATED CHROMADEK 50mm glass fibre insulation to be installed on ceiling
plaster & paint
CONCRETE ROOF
plaster & paint -CONCRETE ROOF TO ENGINEER'S DETAIL WITH MINIMUM 50mm THICKNESS
plaster & paint plaster & paint
plaster & paint plaster & paint plaster & paint
-VERMICULITE SCREED GRADED TO 1:50 FALL TO 100m DIAMETER BILD IN DOWNPIPES
3060mm ceiling level 3060mm ceiling level
3060mm ceiling level 3060mm ceiling level
plaster & paint -WATERPROOFING BY SPECIALIST WITH A TEN YEAR GUARANTEE AS PER SPECIFICATION

2125mm below lintol 2125mm below lintol FLOORS AND WATERPROOFING


2125mm below lintol 2125mm below lintol
-GROUND FLOOR SLAB=85mm THICK 20mpa CONCRETE PERFECTLY LEVEL AND AT
MINIMUM 150mm ABOVE GROUND LEVEL ON PROPERLY COMPACTED HARDCORE FILL
plaster & paint -25mm THICK SCREED AND FINISHES AS INDICATED
-SUSPENDED CONCRETE FLOOR SLABS TO ENGINEER'S DETAIL AND SPECIFICATIONS
WC
WC B -DPC UNDER ALL WALLS (EXCEPT FREE STANDING), FLOORS AND WINDOW SILLS
B 000mm floor finish level 000mm floor finish level AND TO ALL VERTICAL CHANGES IN FLOOR LEVELS
000mm floor finish level 000mm floor finish level -255mm ground level -255mm ground level -FLUSHINGS TO ALL PARAPETS AND CHANGES IN ROOF LEVELS
-255mm ground level R.E R.E -255mm ground level R.E R.E
I.E I.E INVERT LEVE L=+450 mm. I.E
I.E pvc soil pipe laid to I.E FROM CATCHPIT FITTED WITH GRATING AND SILT TRAP
pvc soil pipe laid to IF LESS ENCASE IN CONC
min 1:40 fall connecting to septic tank -PLANTERS TO BE WATERPROOFED AND DRAINAGE INSTALLED
min 1:40 fall connecting to septic tank /future municipal sewer
/future municipal sewer FOUNDATIONS, BRICKWORK & PARTITIONS
ALUMINIUM CORRUGATED CHROMADEK -ALL FOUNDATIONS TO BE 25mpa CONCRETE , AT LEAST 200x700mm. MINIMUM
ALUMINIUM CORRUGATED CHROMADEK ALUMINIUM CORRUGATED CHROMADEK
200mm UNDER GROUND TO ENGINEER'S DETAILS AND SPECIFICATIONS
ALUMINIUM CORRUGATED CHROMADEK -BOUNDARY WALLS' FOUNDATION MUST NOT ENCROACH ON BOUNDARY AND WALLS
ARE TO BE PLASTERED AND PAINTED ON THEW INNER WALL
-PARAPET WALLS TO BE ATLEAST 300mmHIGH AND MAXIMUM 500mm WITH BRICKFORCE
IN EVERY COURSE
plaster & paint plaster & paint
3060mm ceiling level 3060mm ceiling level 3060mm ceiling level 3060mm ceiling level -ALL SCREEN WALLS TO BE AT LEAST 1800mm HIGH ABOVE GROUND LEVEL
-LINTOLS TO BE SUPPORTED MINIMUM 150mm FOR OPENINGS UPTO 4800mm.BRICKFORCE
plaster & paint
plaster & paint plaster & paint plaster & paint TO BE BUILT IN EVERY COURSE BELOW FLOOR LEVEL AND ABOVE WINDOW LEVEL, EVERY
2125mm below lintol 2125mm below lintol 2125mm below lintol 2125mm below lintol THIRD COURSE BETWEEN BETWEEN IN CONTINOUS BANDS
-NO TEETHING OR BLOCK BONDING WILL BE ALLOWED UNDER ANY CIRCUMSTANCES
-ANY PARTITION TO BE RODENT PROOF

STAIRS AND BALUSTRADES


-STAIRS TO BE 750mm MIN WIDTH, TREADS 300mm , RISERS 170mm WITH 6mm MAX DEVIATION
-1000mm HIGH BALUSTRADES TO ALL STAIRS AND BALCONIES
000mm floor finish level 000mm floor finish level 000mm floor finish level 000mm floor finish level -MAX 3000mm VERTICAL RISE PER FLIGHT , WINDERS WHERE SHOWN ,TO BE AT LEAST 250mm
-255mm ground level -255mm ground level -255mm ground level -255mm ground level WIDE, 450mm FROM THE NARROW END AND ANGLE BETWEEN THE RISERS TO BE CONSTANT
-MINIMUM HEADROOM TO BE 2100mm MEASURED FROM PICHLINE
NEW WALLS TO BE PLASTERED & PAINTED -GLASS BALUSTRADES (IF SHOWN ) TO BE SAFETY GLASS
TO CLIENT'S CHOICE
GLAZING
EXISTING WALLS TO BE REPAINTED TO
MATCH NEW FINISHES portal frame for the roof fixed to wall 114x38mm s.a pine wall plate
EXISTING WALLS TO BE DEMOLISHED MAKE
GOOD & MATCH NEW FINISHES embedded at least 300mm into brickwork with connecting devices according to -BATHROOM WINDOWS TO BE FROSTED GLASS
table l2, schedule 1, of sabs 0400 -ALL GLAZING ON DOORS TO BE SATETY GLASS
all web members to be minimum 38x114mm grade 4 with equal bays smaller -ALL GLAZED AREA LESS THAN 300MM ABOVE FFL TO BE COVERED WITH SATETY GLASS
INVERT LEVE L=+450 mm. R.E than 1500mm. approaved bracing must prevent buckling and keep trusses upright
R.E I.E IF LESS ENCASE IN CONC I.E valley and hip rafters to be grade 6 50x228 sa pine
beam over laminated timber to comply with sabs 876 AREA SCHEDULE
beam over 50mm glass fibre insulation to be installed on ceiling EXISTING FLOOR AREA =
ALUMINIUM CORRUGATED CHROMADEK
BIC NEW FLOOR AREA =
demolished
wall ALUMINIUM CORRUGATED CHROMADEK TOTAL FLOOR AREA =
fire wall
WHB plaster & paint SITE PLAN AREA =
B
SITE COVERAGE = %
plaster & paint
trusses by specialist
3060mm ceiling level 3060mm ceiling level
6.4mm gypsum ceiling board DOORS & WINDOWS SCHEDULE
plaster & paint
fire wall

plaster & paint 170mm conc


fire wall

slab roof to SEE SCHEDULE DRAWINGS OF DOORS AND WINDOWS


2125mm below lintol engi's detail 2125mm below lintol
shower
WHB
DO NOT SCALE THE DRAWINGS
220mm SOLID BRICK WALL PLASTERED
BIC BIC shower & PAINTED INTERIOR & EXTERIOR
beam over

B BRICK ON EDGE WINDOW SILL OR


plaster & paint dpc EQUALLY APPROAVED
BIC WC
B
000mm floor finish level dpc dpc 000mm floor finish level
WHB -255mm ground level -255mm ground level
demolished

30mm THICK SCREED LAYED ON


wall

I.E 85mm THICK CONC SURFACE BED


600x230mm 600x230mm 800x230mm
WC concrete footing concrete footing
pvc soil pipe laid to concrete footing
beam over
min 1:40 fall connecting to septic tank
/future municipal sewer

10mm thick 150mm thick


internal plaster brick wall
BUILDING MUST BE CONSTRUCTED DAMP PROOF MEMBRAINE
ACCORDING TO ALL DETAILS AND SPECIFICATIONS
CONTAINED IN THESE DRAWINGS AS PER SANS 1400. FLOOR FINISH AS ON FLOOR PLAN 10mm thick
ANY CHANGES TO DETAILS OR SPECIFICATIONS skirting to match external plaster
MUST BE APPROVED BY ARCHITECT. floor finish
ENERGY EFFICIENCY SPECIFICATIONS MUST BE 30mm SAND CEMENT SCREED damp proof
APPLIED TO, ACCORDING TO 85mm SURFACE BED membraine
SANS 10400-XA SHEET ATTACHED HEREWITH. 25mm SAND BLINDING

150mm WELL COMPACTED


GLAZED EARTHENWARE
DISHED GULLEY CAST
HARDCORE
IN CONCRETE ngl CLEANING EYE ngl
350 min

soil pipe less than


1m deep

pipe laid 600x230mm CONCRETE STRIP


to min 1:40
fall FOUNDATION FOOTING

INVERT LEVEL=+450 mm.


IF LESS ENCASE IN CONC