Professional Documents
Culture Documents
Victaulic Outlet Coupling Style 72
Victaulic Outlet Coupling Style 72
Victaulic Outlet Coupling Style 72
Style 72 06.10
Rev F
WARNING
• Victaulic RX roll sets must be used when grooving
light-wall/thin-wall stainless steel pipe for use with
Victaulic Couplings.
Failure to use Victaulic RX roll sets when grooving
light-wall/thin-wall stainless steel pipe may cause joint
failure, resulting in serious personal injury and/or
Female Threaded Outlet
property damage.
Approvals/Listings
NOTICE
• Victaulic RX grooving rolls must be ordered
See Victaulic publication 10.01 for details separately. They are identified by a silver color and
See Victaulic publication 02.06 for portable water approvals if applicable. the designation RX on the front of the roll sets.
Product Description
Job/Owner Engineer
System No. Spec Section
Location Paragraph
Contractor Approved
Submitted By Date
Date
1
victaulic.com | Couplings | Outlet | Style 72 | Publication 06.10
Material Specifications
Housing: Bolts/Nuts:
Ductile iron conforming to ASTM A-536, grade 65-45-12. Heat-treated plated carbon steel, trackhead meeting the
Ductile iron conforming to ASTM A-395, grade 65-45-15, physical and chemical requirements of ASTM A-449 and
is available upon special request. physical requirements of ASTM A-183
06.10 1660 Rev F Updated 09/2014 © 2014 Victaulic Company. All rights reserved.
victaulic.com 2
victaulic.com | Couplings | Outlet | Style 72 | Publication 06.10
Dimensions
Style 72
Y Z
T V
06.10 1660 Rev F Updated 09/2014 © 2014 Victaulic Company. All rights reserved.
victaulic.com 3
victaulic.com | Couplings | Outlet | Style 72 | Publication 06.10
Y Z
T V
06.10 1660 Rev F Updated 09/2014 © 2014 Victaulic Company. All rights reserved.
victaulic.com 4
victaulic.com | Couplings | Outlet | Style 72 | Publication 06.10
Performance
Cv/kv values for flow of water at +60ºF/+16ºC are shown in the table below.
Formulas for Cv/kv values:
∆P = Q2 Where:
Cv2 Q = Flow (GPM)
∆P = Pressure Drop (psi)
Q = Cv x ∆P Cv = Flow Coefficient
Installation Note
Reference should always be made to the I-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications. All products
the product you are installing. Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions.
products for complete installation and assembly data, and are available in PDF format Victaulic reserves the right to change product specifications, designs and standard
on our website at www.victaulic.com. equipment without notice and without incurring obligations.
Warranty Trademarks
Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic ® is a registered trademark of Victaulic Company.