Designer:
CHECt
ASSOCIATION OF STRUCTURAL ENGINEERS OF THE
PHILIPPINES, INC. (ASEP)
‘KLIST OF MINIMUM STRUCTURAL DESIGN DOCUMENTS
Project
Location:
1,
i
4.0 | STRUCTURAL PLANS
(GENERAL NOTES
14.1.
ITEMS ok | NA
REMARKS
MATERIAL SPECIFICATIONS —_
14.2
TYPICAL DESIGN & CONSTRUCTION DETAILS (Beam, Column,
‘Slab Footing, Wall Constuction Joint, Rebar Spices & Bends, etc)
| Fount
IDATION PLAN; foundation details
FLOOR FRAMING PLANS
__| ROOF FRAMING PLAN
BEAM
GIRDER SCHEDULE, TYPICAL DETAILS
| Foon
SLAB
COLUMN SCHEDULE, TYPICAL DETAILS
ING SCHEDULE, TYPICAL DETAILS
‘SCHEDULE. TYPICAL DETAILS _
SHEAR WALL SCHEDULE, TYPICAL DETAILS _
[TRUSS SCHEMATIC DIAGRAMS, TRUSS CONNECTION DETAILS
| BASEMENT WALL DETAILS
4.12. | STAIR
DETAILS
[4.134
1.13.2
MISCELLANEOUS DETAILS
Connection Detail
‘Special Foundation Deal (Orven Pe, Bored, Jet Grout, Ge Pr, ote)
2.0 | STRUCTURAL CALCULATION
24.
DESIGN CRITERIA _
21.
DESIGN CODE AND REFERENCES
INSCP. Volume J, Sith Edtion 2010 for Buldngs, Towers and Other
Vertcal Smuctres
24.2
Occupancy Category (Table 103-1, NSCP 2010)
| 243.
DESIGNLOADS
| 24.3.1. | DEADLOAD __
‘Sefweight of the structure
| Root framing and rooting system
Floor slab system
| Wall prttions (exterior and interior was)
Movable partons
Floor fishes:
| Celing shes
| Electrical, mechanical utlties and services
ther miscaaneous weighs
STRUCTURAL CHECKLIST Page of 3ASSOCIATION OF STRUCTURAL ENGINEERS OF THE
PHILIPPINES, INC. (ASEP)
TEMS
LIVE LOAD
ExitFecites
| Toilet and Bath
Other
24.32. | SEISMIC LOAD PARAMETERS
Zone Zz
Distance fom seismic source
Seismic source type
: Importance factor 1
Duty force coefcient R
Sol profile type s
Near source factors N,
Static Analysis
__| Dynamic Analysis
| 21.34. | WIND LOAD PARAMETERS:
Zone
| Basic wind speed
| Importance factor 1,
| Surface roughness category CT
|__| Exposure category
21.35. | MISCELLANEOUS (Fu, Earth,
MATERIAL SPECIFICATIONS
___| Minimum specified 28-day concrete compressive strength ft
I Minimum specified yield strength of reinforcing bars f
‘Minimum specified yield strength of welded wire mesh hy
| ‘Minimum specified yield strength of structural steel fy
| i {hat-roled) z
Minimum spectfed yield strength of cod-formed steel
Minimum specified yield strength of prestessing steel f,,
(tendons)
Welds: Electrode Classification Fez
Botts: Classification
Other materiats
22.__| STRUCTURAL ANALYSIS z is
] Whenever Siructural Engineering Sofware is used, 30/2D Model Data input
| shall be printed as part ofthe Structural Calculation Document
23. _| STRUCTURAL DESIGN
‘Whenever Stuctural Engineering Software is used, Detaled Dasion Check for
Crtical Members shal be printed as par of the Stuctural Calculation Document
24. | COMPUTER PROGRAMS
| 2.4.1. | NSCP 2010, Secon 108.43. allows the use of Computer Program|
Structural it
‘Analysis and Design but the Engineer-otRecord stil has the Full
| Responsbty ofthe Stucural Design et =
The folowing requirements apply to calculations which include such |
computer output
STRUCTURAL CHECKUST Pope 20f8ASSOCIATION OF STRUCTURAL ENGINEERS OF THE
PHILIPPINES, INC. (ASEP)
_WTEMS
24.1.1. | Drawing of the complete mathematical mode! used to
represent the the structure in the computer-generated
| analysis. zi
244.2. | Program descrpion giving the program name, the
version number, and the company and is addres shall
| be part ofthe computation documents, —
24,13. | CD or DVD Archived Copy of all Computer Run in PDF
| format os
24.1.4. | The fist sheet of each computer run shall be signed and
sealed by the Engineer-of Record
| 242 | Photocopy of the Computer Program License shall be part of the
Stucura Caution Documents
Propared By:
Chaiman, Siuctual Checkist
‘Approved by the Officers and Board of Directors of the Association of Structural Engineers of the Philippines, Inc. (AEP);
cl TAY, wases
‘ADAM C. ABINALES,
Director
arc ar—
LESSANDROESTELITO 0. GARCIANO, user
Director
BER FRANCIS ‘G. VALDERRAMA, maser
Director Director
oa
\RLOS M. PPA FASE
‘immediate Past 8 Ex-Officio
STRUCTURAL CHECKUST Page 30f3