Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Instructions for Seylan Upgrades + PMs - V1.

1 March 15, 2018

Start

· Mr. Sukitha – 0715360768/


0112456170

Inform to Seylan IT

· IP Address
Take Cash status
· Sub Net Mask for bank
· Default Gateway
· Remote Server
· Port Bank
Bank
· Time Server
· DNS IP Addresses Collect setting
details of ATM

Pidgen
Is Win 7 Product Collect Win 7 V1.1.3.59
No
Key available? Product Key Windows Key
finding utility

Yes
This utility can be downloaded from the
link:
Back up
Ejournels https://drive.google.com/
USB open?id=0B6419OhiwqgYdEQzbDBiRHA4
USB Pen
Pen Drive
Drive
NE0

Is enough space Repartition HDD as


No
available in C: required

Yes

Restore backup

· Create “JOURNAL” folder in D: drive


· Change computer name
Set up ATM · Bind IP & check SFTP
· Run “netsh firewall set icmpsetting 8
enable” in command prompt

To page o2 – Copy ejournels To page 02 – Activate OS of PC To Page 02 - Check functions of


ATM

Compiled by Lagath Thrimahavithana Manager - ATM Banking Installations


Page 1
From page 01 – USB pen drive From Page 01 – Set up ATM From Page 01 - Bank

Activate OS of PC
· Enable ports by disabling
firewall
· Connect USB 3G Dongle
· Activate Windows 7
Copy · Disable ports by enabling
Ejournels
firewall again.

Check functions
of ATM

EMV functions should be checked with chip Following data should be


card & Seylan IT should confirm EMV clearly mentioned on FSR for
functionality. PM
Are all Ok? No Rectify the issue · Dates & times
· Models & Serial No.
· Signatures of engineer &
Yes customer
· Customer’s name & any
ID No.
Back up C: to D: · Call text: Preventive
maintenance
· Correction action: “The
preventive maintenance
was done successfully”
Fill FSR for PM &
Do Preventive
Following data should be clearly related document
maintenance
mentioned on FSR for upgrade
· Dates & times
· Models & Serial No.
· Signatures of engineer & customer
· Customer’s name & any ID No. Was Win 7
Label Win 7
Product Key No
· Call text: Software upgrade availble?
Product Key
· Correction action: “The upgrade was
done successfully”
Yes

Fill check list &


FSR for upgrade

Enter FSR details


to system
FSR should be handed over to TL within 2
days.

Hand over FSR to


your Team Lead

End

Compiled by Lagath Thrimahavithana Manager - ATM Banking Installations