Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

QRH Release in Normal Mode

Signal Element Action Location Service Tag No.


Tag No. Service Location Contact Status Symbol
Logic components located in ISC cabinet (HRIU)
1 = Release EN
Master RE Enable Relay DE-EN QRH (HARE) Release Enable
Release SW CMSC Open
0 = Off
“Normal” Pos. Logic components located in HARE (Release PCB) Local Release
1 = Release
Hook X HR PB QRH (HARE) Request for
QRH (HARE) Open 0 = Off
Release PB Hook X
Logic components located in ISC cabinet (Server PC) Remote Rel.
Hook X CMSC or ISC Open Modbus QRH (HARE) Request for
RC PB
Release PB (SCADA) (Modbus) Hook X

QRH Emergency Release in Normal Mode

Logic components located in ISC cabinet (HRIU)


Tag No. Service Location Contact Status Symbol
Signal Element Action Location Service Tag No.
Master
1 = Release
Release SW CMSC Open EN
RE Enable Relay QRH (HARE) Release Enable
“Normal” Pos. S DE-EN
Master & 0 = Off
R
Emergency CMSC Open S 1 = Activated EN ESD-2B
& Relay ESD
Release PB R
0 = Off DE-EN Activated
Master
1 Master Emerg.
Release SW CMSC Open 1 = On EN
Relay DCS Release
“Normal” Pos. 0 = Off DE-EN
Confirm
Confirm PB CMSC Open &
Pulse Timer 1 = Release All EN
(10 seconds) Relay QRH (HARE) Release All
RA 0 = Off DE-EN
Master Emerg.
ESD Permissive ESD Open 1 = On IND
Lamp CMSC Release PB
S
0 = Off N-IND
Lamp
& >=1
R
Lamp Test PB CMSC Open

QRH Emergency Release in Bypass Mode

Tag No. Service Location Contact Status Symbol Signal Element Action Location Service Tag No.
Logic components located in ISC cabinet (HRIU)
Master 1 = Release
EN
Release SW CMSC Open RE Enable Relay QRH (HARE) Release Enable
DE-EN
“Bypass” Pos. 0 = Off
Master &
1 = Release All EN
Emergency CMSC Open Relay QRH (HARE) Release All
S RA 0 = Off DE-EN
Release PB >=1
Master R Master Emerg.
1 = On IND
Release SW CMSC Open Lamp CMSC Release PB
0 = Off N-IND
“Bypass” Pos. Lamp
1 Master Emerg.
Pulse Timer 1 = On EN
Confirm PB CMSC Open &
(10 seconds) Relay DCS Release
0 = Off DE-EN
Confirm

Lamp Test PB CMSC Open


QRH Hook Actuator & Release Enclosure (HARE)
RRC Logic Diagram

Tag No. Service Location Contact Status Symbol Logic components located in HARE (Release PCB) Signal Element Action Location Service Tag No.

1 = Release Move actuator


Release Enable ISC (HRIU) Open RE
&
Pulse Timer Pull Release
(7 seconds) Pull Hook Actuator QRH (HARE) to Release
cable
0 = Off position
Hook Release 1 = Actuator to Move Actuator
QRH (HARE) Open HR PB Push Release
PB Pulse Timer
Push Home Actuator QRH (HARE) to Home
(7 seconds) cable
Remote Rel. 0 = Off Position
CMSC or ISC Open 1 = Home Pos.
Request for RC PB >=1 IND Release Limit
(SCADA) (Modbus) 0 = Released Limit Switch QRH (HARE)
Hook X LS N-IND Switch Status
Pos.
Release All ISC (HRIU) Open RA

Release Pull timer


QRH (HARE) Open complete
Complete

Release Limit
QRH (HARE) Closed
Switch
Key Abbreviations

Integrated
1 ‘NOT’ Gate ISC System RE Release Enable
Cabinet
Central
Input CMSC Monitoring RA Release All
System Consol
Hook Actuator
XX Signal coming Release
HARE & Release RC
from Command
Enclosure
Quick Release Hook Release
& ‘AND’ Gate QRH HR PB
Hook PB
Emergency
>=1 ‘OR’ Gate ESD Shutdown
Device
S
Set-Reset Hook Actuator
HRIU
R Flip-Flop Interface Unit
Supervisory
Timer Timer SCADA Control & Data
Acquisition
Pulse Timer Hook Release
Pulse Timer HRCS
R Control Station

Printed Circuit
XX Signal going to PCB
Board

Output
System Diagram
Key

24V DC Signal
DCS ESD

Serial Comms
Master
Emergency (Modbus)
Release Confirm
ESD-2B Activated
Ethernet
ESD Permissive

Release Enable
HARE
HRIU

Release All

RS485 Modbus (Release

Master Release Switch


Lamp Test PB

Master Emergency Release


Confirm PB

(Off/Normal/Bypass)
Hook Release PB (local) System Status and Release
Commands )
Release PCB Serial-Ethernet Converter

PB with Lamp
Release (push-pull cable)
Limit Switch
Ethernet Switch

Actuator - Pull
(moves push-pull cable
to released position)
HRCS
Actuator - Push
(moves push-pull cable to home
position)

SCADA SCADA

QRH ISC CMSC

You might also like