Improved Ground Wire for the Monitor Circuit Is Now Used on Certain 320D2
Excavators {1408, 7490}
Media Number -M0083787-00 Publication Date -01/06/2017 Date Updated -01/06/2017

i07044387

Improved Ground Wire for the Monitor Circuit Is Now Used


on Certain 320D2 Excavators {1408, 7490}
SMCS - 1408; 7490

Excavator
320D2 (S/N: ZBD1-10964; ESG1-10120; TGJ1-10003; WDJ1-10022; YBK1-220; ZBM1-
154; STN1-10002; XAN1-10037; DNS1-10057; WBY1-10151; RDZ1-10109; TDZ1-10054)

Description Of Change: An improved ground wire for the monitor circuit is now used on the
machines listed above. This improved circuit will eliminate the risk of operator monitor group failure.

Adaptable To: The following changes are adaptable to the products within the listed serial numbers,
and are effective with all products after the listed serial numbers.

Table 1
Required Part List
Qty Part Number Part Name
1 436-6210 (1) Operator Monitor Gp
(1)
After failure only
Add an additional ground wire from the wiper controller to the ground directly. Adjust different
platform ground wire terminal order, ensure strap terminal contact to ground boss directly.

Follow the"Rework Procedure"to separate the wiper controller ground line.