ON FITTING ISSUES
2
2
1 1
OLD NEW
1). Top Cover Inner Diameter -560mm But we were using 565mm. 1). Top Cover Inner Diameter -560mm But we observed 559mm
2) Spindle shaft Diameter - 560mm 2) Spindle shaft Diameter -560mm
Problem:- Problem:-
1). Fitting vise ok 1). Fitting vise not ok
Note:- Note:-
Fitment clearance between Top cover & Spindel shaft - (+5mm) Fitment clearance between Top cover & Spindel shaft - (-1mm)