Reese and Matlock curve from "Pile Design and Construction Practive 4th ed" by M.J. Tomlinson
PIle Length X
m Z = X/T Fm Moment, Mf = Fm * H * T
0 0.000 -0.9 -2122
1 0.296 -0.6 -1415
2 0.591 -0.35 -825
3 0.887 -0.2 -472
4 1.183 0 0
5 1.479 0.2 472
6 1.774 0.25 590
7 2.070 0.25 590
8 2.366 0.25 590
9 2.661 0.25 590
10 2.957 0.2 472
11 3.253 0.2 472
12 3.549 0.1 236
13 3.844 0.05 118
14 4.140 0 0
15 4.436 0 0
16 4.731 0 0
17 5.027 0 0
18 5.323 0 0
19 5.619 0 0
20 5.914 0 0
21 6.210 0 0
DUE TO RESISTANCE OF CRACK WIDTH (DIRECT TENSILE STRENGTH OF STEEL) Ratio 0.92
From BS8007:1987 section 3 (Table 3.1)
Limit states
Direct Tensile Strenght Steel, Fst 130.00 Crack with ≤ 0.2mm
Area of steel req., As req 22307.69 mm² Fst/Qwt
Actual Provided steel, As act 24120.00 mm²
DUE TO RESISTANCE OF CRACK WIDTH (DIRECT TENSILE STRENGTH OF CONCRETE) Ratio 0.51
Percentage 10
Direct Tensile Strenght Conc, Fct 5.5 MPa Percentage * Fcu
Modular ratio, m 6.343 Es/Ec
Area of concrete req., Ac req 398389 mm²
Actua area of concrete, Ac act 785398 mm²