General-purpose Threaded
Capacitive Sensor
• Product lineup with M12, M18, and M30 models.
• Fixed sensing distance requires no sensitivity adjustment.
Ordering Information
Sensors [Refer to Dimensions on page 6.]
Model
Appearance Sensing distance Output configuration Operation mode
NO NC
DC 3-wire, NPN E2K-X4ME1 2M E2K-X4ME2 2M
M12 4 mm
AC 2-wire E2K-X4MY1 2M E2K-X4MY2 2M
Unshielded DC 3-wire, NPN E2K-X8ME1 2M E2K-X8ME2 2M
M18 8 mm
AC 2-wire E2K-X8MY1 2M E2K-X8MY2 2M
DC 3-wire, NPN E2K-X15ME1 2M E2K-X15ME2 2M
M30 15 mm
AC 2-wire E2K-X15MY1 2M E2K-X15MY2 2M
1
E2K-X
Ratings and Specifications
2
E2K-X
Engineering Data (Typical)
18
16
E2K-X15M
14
Y
12 X
Standard sensing
10 object Grounded
metal plate
50 × 50 × 1 mm
8
E2K-X8M
6
4
E2K-X4M
2
0
−5 −20 −15 −10 −5 0 5 10 15 20 25
E2K-X4M Sensing Distance
E2K-X8M Sensing Head Y (mm)
E2K-X15M Sensing Head
10
Distance X (mm)
25
Distance X (mm)
d× d× d×
d t = 3 mm d t = 3 mm d t = 3 mm
X Grounded metal X X
Grounded metal
4 8 20
3 Grounded metal
6 15
Non-grounded metal
Non-grounded metal Non-grounded metal
2 4 10
Glass
Glass Phenol
1 2 5 Acryl
Phenol
Glass
Acryl
Phenol
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Side length of sensing object: d (mm) Side length of sensing object: d (mm) Side length of sensing object: d (mm)
10
Distance X (mm)
5 25
Distance X (mm)
50 ×
50
t
X
4 8 20
Grounded metal 50 × Grounded metal
50 × 50
50 t
t X
X Grounded metal
3 6 15
Non-grounded metal
Non-grounded metal Non-grounded metal
Glass
2 4 10 Glass
Phenol Phenol
Glass
Acryl
1 2 5
Phenol Acryl
0 5 10 15 20 25 0 5 10 15 20 25 0 5 10 15 20 25
Thickness of sensing object: t (mm) Thickness of sensing object: t (mm) Thickness of sensing object: t (mm)
3
E2K-X
1.5 80 160
Protective resistance
mA
AC V V
power, 60 120
V
50/60Hz
(OFF) VL VL
100 VAC 200 VAC
1.0 40 A 80 A
20 40
Residual
Residual Load
Load Voltage OFF Voltage OFF
0 0
0 100 200 300 3 5 10 20 30 50 100 200 3 5 10 20 30 50 100 200
Power supply voltage (V) Load current (mA) Load current (mA)
Present
Sensing object
Not present
Load (between brown Operate
E2K-X4ME1 and black leads) Brown
Reset +V
NO E2K-X8ME1 100 Ω
Output voltage (between High
E2K-X15ME1 black and blue leads) Low Load
ON Proximity 4.7 kΩ
Detection indicator (red) Sensor Black*1
OFF
main
2.2 Ω Output*2
circuit
Tr
AC 2-Wire Models
Operation
Model Timing chart Output circuit
mode
4
E2K-X
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring Sensing Objects
safety of persons either directly or indirectly. The maximum sensing distance will decrease if the sensing object is
Do not use it for such purposes. a non-grounded metal object or dielectric object.
• Sensing Object Material
The E2K-X can detect almost any type of object. The sensing
Precautions for Correct Use distance of the E2K-X, however, will vary with the electrical
Do not use this product under ambient conditions that exceed the characteristics of the object, such as the conductance and
ratings. inductance of the object, and the water content and capacity of the
object. The maximum sensing distance of the E2K-X will be
● Design obtained if the object is made of grounded metal.
• There are objects that cannot be detected indirectly. Therefore, be
Ambient Environment sure to test the E2K-X in a trial operation with the objects before
The Sensor may malfunction if subjected to water, oil, chemicals, or using the E2K-X in actual applications.
condensation by falsely detecting these as sensing objects.
The E2K-X15M is highly sensitive to inductive objects and can thus Effects of a High-frequency Electromagnetic Field
be affected even by small quantities of water drops. The E2K-X may malfunction if there is an ultrasonic washer, high-
frequency generator, transceiver, or inverter nearby.
Influence of Surrounding Objects For major measures, refer to Noise of Warranty and Limitations of
If the Sensor is embedded in metal, maintain at least the following Liability for Photoelectric Sensors.
distances between the Sensor and the metal. The Sensor is also
affected by other materials, such as resins. Separate the Sensor from Mounting
other materials by the same distance as for metal. Do not tighten the nut with excessive force. Always use washers when
tightening the nuts and do not exceed the torque in the following table.
l
d dia. m
n
Model Torque
*
Be sure to ground. Metal object E2K-X4M 0.78 N·m
* Be sure to ground the metal object, otherwise Sensor operation will not be E2K-X8M
stable. 2 N·m
E2K-X15M
Influence of Surrounding Metal (Unit: mm) Note: A special tightening tool is provided with the E2K-X4M@@. Always use
this tool to tighten the nuts.
Model Dimension l d m n
E2K-X4M 8 ● Miscellaneous
20
E2K-X8M 50 12 60 Organic Solvents
E2K-X15M 10 25 The Sensor has a case made of heat-resistant ABS resin. Be sure
If a mounting bracket is used, be sure that at least the following that the case is free from organic solvents or solutions containing
distances are maintained. organic solvents.
Model Dimension G H
E2K-X4M
20
E2K-X8M 30 H
E2K-X15M 10
Mutual Interference
When installing Sensors face-to-face or side-by-side, ensure that the
minimum distances given in the following table are maintained.
B
A
5
E2K-X
(Unit: mm)
Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
E2K-X4ME@ E2K-X8ME@
E2K-X4MY@ E2K-X8MY@
80 80
21 dia. 29 dia.
60 60
17 24 20 Indicator *2
20 Indicator *2 4 4
4 4
10.7 dia.
16.6 dia.
*1
*1
M12 × 1
Two clamping nuts M18 × 1
Two washers Two clamping nuts
Two washers
*1. E Models: 4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.2 mm2, Insulator diameter: 1.2 mm), *1. E Models: 6-dia. vinyl-insulated round cable with 3 conductors
Standard length: 2 m (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),
Y Models: 4-dia. vinyl-insulated round cable with 2 conductors Standard length: 2 m
(Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Y Models: 6-dia. vinyl-insulated round cable with 2 conductors
Standard length: 2 m (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),
*2. E Models: Detection indicator (red) Standard length: 2 m
Y Models: Operation indicator (red) *2. E Models: Detection indicator (red)
Y Models: Operation indicator (red)
28.1 dia.
*1
M30 × 1.5
Two clamping nuts
Two washers
*1. E Models: 6-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
Y Models: 6-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
*2. E Models: Detection indicator (red)
Y Models: Operation indicator (red)