EXAMPLE: Bodine gearmotor stock model 0670, type 42R-5N. Connection diagram 07410296.

Black/Yellow 1 2
Blue/Yellow
Line Motor
Black
Blue
capacitor
Green/Yellow

Clockwise rotation when viewing the output shaft.

To reverse the direction of rotation, transpose


black and black-yellow leads.

Connection Diagram 07410296: Identify the wire colors and confirm that Following connection diagram 07410296,
4-wire reversible you have a 4-wire-reversible PSC motor connect the blue wire to one side of the
or gearmotor. Bodine stock motors and capacitor. The capacitor is not labeled with
gearmotors will have black, blue, black- polarities, so the connection may be made
yellow, blue-yellow motor leads and a green- to either wire. PSC motors will not operate
yellow ground lead. Identify the correct properly without the correct run capacitor.
capacitor value to be used with the motor/
gearmotor. The capacitor specifications
are listed on the gearmotor nameplate.

3 4 5

Connect the other side of the capacitor Now the capacitor is permanently wired T o complete wiring, connect the
to the black lead from the motor/ into the winding. This is important because motor’s green-yellow ground to
gearmotor, and one of the hot leads a Permanent Split Capacitor motor uses the ground on the AC line.
from the AC motor cord (see wiring the capacitor during start and during
diagram). Since the wiring diagram run. Proceed by connecting to the other
does not specify AC line lead polarities, side of the AC line. Connect the black-
the connection may be made to either yellow and blue-yellow motor leads
side of the AC line (i.e. hot or neutral). to the other side of the AC line. Again,
the connection may be made to either
side of the AC line (i.e. hot or neutral).

201 Northfield Road | Northfield Illinois, 60093, U.S.A. | Tel: 773.478.3515 | Fax: 773.478.3232 | www.bodine-electric.com | info@bodine-electric.com 07470039.A page 1
Bodine Electric Company APPLICATION
Installing a Terminal Box onto the Motor/Gearmotor (IP-44)
EXAMPLE: Terminal Box model 0984. Mounting Instructions 07400067E.

1 2 3

The motor/gearmotor is factory installed Adhere the foam gasket to the outside face Secure the terminal box to the motor/
with a bushing on the lead exit. In order of the terminal box with the precut gasket gearmotor’s center ring. Follow
to install the terminal box onto the motor/ holes aligned with the terminal box holes. the instructions detailed in the
gearmotor, this bushing must be removed. Then pull the terminal leads through the Mounting Instructions for Bodine
Unscrew and remove the plastic bushing opening in the back of the terminal box. Type 34R, 42R and 48R (AC) Motor and
from the motor/gearmotor’s center ring Gearmotor U.S.A./Canada Terminal
terminal opening and discard (except Box Kit (literature no. 07400067E).
for type 34R motors/gearmotors. Leave
the standard bushing in place).

4 5 6

T he capacitor for this gearmotor fits Make all connections per the motor/ Follow the instructions detailed in
inside the terminal box, as do most of gearmotor wiring diagram, adding a literature no. 07400067E to fasten the
the standard stock capacitors for stock cord/capacitor/etc. as instructed by terminal box cover and gasket onto the
PSC motors/gearmotors. Install the the manufacturer. Add a strain relief terminal box with the 4 screws provided.
run capacitor inside the terminal box. or PG fitting to the cord exit to meet
Mount larger capacitors externally. IP‑44 (not supplied with terminal box).

Bodine’s die cast terminal box kits give our motors and IP-44 Definition
gearmotors an environmental protection rating of IP-44
When fitted with a terminal box our motors/gearmotors also meet NEMA Type 2 1mm 1mm
environmental standards as a general purpose indoor enclosure with drip shield protection to
Solid Objects Moisture
protect from falling liquid or dirt. They are not protected against dust or internal condensation.
Protection from Protection from
For more information, download the Bodine Handbook by clicking here. solid objects greater splashing water
than 1.0mm

© Copyright 2013. All rights reserved.

201 Northfield Road | Northfield Illinois, 60093, U.S.A. | Tel: 773.478.3515 | Fax: 773.478.3232 | www.bodine-electric.com | info@bodine-electric.com 07470039.A page 2

You might also like