4
02 Market Trend
1. Enforced EU Regulatory and Legislation for Energy
- RE (Renewable Energy) use and energy efficiency should be increased
- EU included air-to-water heat pumps in the renewable energy category
World Kyoto Protocol : Till 2012, green house gas should be reduced averagely 5.2% less than
wide that in 1990GHG (8% for EU)
Directives
RE Use Increase Energy Efficiency Increase Low Carbon
RES EPB EUP EE
Renewable Energy Source E. Performance of Building E. Using Products E. Efficiency
World
wide
According to EU Timeline, each nation should implement the Directives above till Feb. 2009
EU
It is expected to be mandatory till about 2012 : Some nations such as France, Germany,
Nations
Sweden and UK have implemented EUP and EPB
5
02 Market Trend
2. Heat Pump : Lower Energy Cost and CO2 Emission Up to 33%
This economical and ecological system not only save energy costs, but also reduce CO2 Emission
using highly efficient heat pump technology.
Economic Ecological
0.00 0.00
Gas Boiler Eco Heating Gas Boiler Eco Heating
6
03 Heat Pump in the Market
Samsung
Year 2009 Daikin Melco LG CIAT (’10 Gen1)
Image
USP Minimal install cost Easy Install CO2 90%↓ Comfort heating CO2 70%↓
Flexible configuration Low Op. cost Digital solution Op. Cost 30%↓ Op. Cost 30%↓
Main
Absolutely safe Minimal maintenance Minimal maintenance Easy Install
Reliable Reliable
7
04 Samsung’s EHS
1. Newly Introduced with A2W and A2A
Solar Panel
Water pipes
Refrigerant pipes
EEV Kit
Indoor Unit
Under Floor
Heating & Radiator
8
04 Samsung’s EHS
2. Integrated Indoor Climate Control in One System
A2W A2A
50%
Saving on
Cost
Radiator Domestic Hot Water Air Heating
9
04 Samsung’s EHS
3. Perfect Solution for Residential House
Water
Air
Air
Air
Water
Water
Water
Air
Water
Water
Water
10
05 Features
1. Smart Time Division Multi Technology
A smart control of Time Division Multi (TDM) operation between air-to-water and air-to-air,
enables one outdoor unit to operate for both functionalities resulting in lower product cost
and space saving.
11
05 Features
2. Enjoy EHS in Various Ways with TDM Technology
Customers can use EHS as multi air-conditioners providing air cooling in summer and air cooling or heating in
spring /autumn, or as a highly efficient boiler in winter, and can enjoy both of these function simultaneously in
such case of quick heating in winter. Sanitary hot water supply is available in any cases.
12
05 Features
3. Quick Heating by TDM Technology
Floor heating is well known as the optimal heating option for indoor thermal comfort. However, it
takes 4~8 hours to heat up the room after it is turned on. Samsung EHS TDM technology quickens that
process by blowing hot air along with floor heating to warm up the room.
80
ON ON
20
80
ON 20 ON ON
Target Temp.
Samsung EHS
Room Temp.
Normal Heat Pumps(Floor Heating)
Initial Temp.
Time
Normally 5~20 minutes
13
06 Benefits
1. High Performance at Low Temperature
Samsung EHS is made up of an inverter compressor optimally operated according to the outdoor
temperature, offering heating performance of 90% at -10°C and reliable antifreezing protection at -20°C.
High Performance of
at -10°C
14
06 Benefits
2. Remote Controller Gives You Easy and Abundant Options
Smart user interface technology has been woven into Samsung EHS to allow easy and
convenient control of the cooling and heating system at home. This control allows onetouch
access to energy consumption statistics and other components (Solar Panel,
Back-Up Boiler, etc) monitoring.
Providing chances to reduce more energy by letting the customer make some choices in
system using patterns!
15
07 Installation
A2A
1. Installation Diagram unit
EEV
Kit
Cooling
A2W RAC
Heating
unit
3
Supply Header
Return Header
DHW Tank
16
07 Installation
3. Installation Guide
17
08 Line-up
2009 2010 2011 2012
11/14/16 KW
RTS : 8/17
Split – Outdoor
[8/11/14 kW]
GEN 1
6/7/8 KW
RTS : 9/23
Split – Outdoor Unit
[6/7/8 & 11/14/16 KW]
GEN 2
Product
Split - Hydro Unit
[8 & 16 KW]
Mono
(1P/3P, 11/14/16 kW)
18
09 Specification – Outdoor Unit
Spec. Comparisons : SAMSUNG vs. DAIKIN
(6/7/8kW) (11/14/16kW) SAMSUNG DAIKIN
Power supply 1Φ/230V 50Hz 1Φ/230V 50Hz
Dimension HxWxD mm 798 × 880 × 310 1,128 x 932 x 375 735 × 825 × 300 1,170x900x320
* Cooling and heating conditions are based on the floor cooling and heating
* Specifications are subject to change without prior notice for product improvement
19
09 Specification – Hydro Unit
Spec. Comparisons : SAMSUNG vs. DAIKIN
Heating ℃ 15 ~ 55 15 ~ 50 15 ~ 55
leaving water
temperature
Cooling ℃ 5 ~ 25 5 ~ 22
Weight kg 45 48 46 48
* Specifications are subject to change without prior notice for product improvement
20
09 Specification – Outdoor Unit (1/2)
ITEM UNIT RD060PHXEA RD070PHXEA RD080PHXEA RD110PHXEA RD140PHXEA RD160PHXEA
Function A2A/A2W Multi A2A/A2W Multi A2A/A2W Multi A2A/A2W Multi A2A/A2W Multi A2A/A2W Multi
POWER SOURCE Ph/V/Hz 1P,230~,50 1P,230~,50 1P,230~,50 1P,230~,50 1P,230~,50 1P,230~,50
CAPACITY Cooling 7,000 7,500 8,000 11,300 14,200 15,500
W
(A2W Condition#1) Heating 6,000 7,000 8,000 11,000 14,000 16,000
CONSUMPTION Cooling 1,945 2,205 2,540 2,900 3,940 4,700
W
(A2W Condition#1) Heating 1,305 1,590 1,925 2,420 3,210 3,900
R/CURRENT Cooling 8.9 10.1 11.6 12.9 17.5 20.8
A
(A2W Condition#1) Heating 6.0 7.3 8.8 10.7 14.2 17.3
EER or COP Cooling W/W 3.60 3.40 3.15 3.90 3.60 3.30
(A2W Condition#1) Heating W/W 4.60 4.40 4.15 4.55 4.36 4.10
ESEER Condition#1 W/W 5.20 5.50 4.90 5.96 5.66 5.50
CAPACITY Cooling 5,000 5,300 5,800 8.50 10.20 10.70
㎾
(A2W Condition#2) Heating 5,300 6,200 7,200 10.00 12.90 14.50
CONSUMPTION Cooling 1,850 2,040 2,320 2,700 3,520 4,040
W
(A2W Condition#2) Heating 1,555 1,875 2,250 2,860 3,850 4,530
R/CURRENT Cooling 8.5 9.3 10.6 12.0 15.6 17.9
A
(A2W Condition#2) Heating 7.1 8.6 10.3 12.7 17.1 20.1
EER or COP Cooling W/W 2.70 2.60 2.50 3.15 2.90 2.65
(A2W Condition#2) Heating W/W 3.40 3.30 3.20 3.50 3.35 3.20
ESEER Condition#2 W/W 3.60 3.70 3.70 4.91 4.82 4.29
EER Cooling W/W 3.21 3.21 3.21 3.46 3.46 3.46
(A2A Condition#3) Heating W/W 4.04 4.04 4.04 3.94 3.94 3.94
- A2W Condition#1: (Heating) Water In/Out 30℃/35 ℃, Outdoor Air DB/WB 7℃/6℃; (Cooling) Water In/Out 23℃/18℃, Outdoor Air DB 35℃
- A2W Condition#2: (Heating) Water In/Out 40℃/45 ℃, Outdoor Air DB/WB 7℃/6℃; (Cooling) Water In/Out 12℃/7℃, Outdoor Air DB 35℃
- A2A Condition#3: (Heating) Indoor Air DB/WB 20℃/15 ℃, Outdoor Air DB/WB 7℃/6℃; (Cooling) Indoor Air DB/WB 27℃/19℃, Outdoor Air DB/WB 35℃/24℃
* Specifications are subject to change without prior notice for product improvement
21
09 Specification – Outdoor Unit (2/2)
ITEM UNIT RD060PHXEA RD070PHXEA RD080PHXEA RD110PHXEA RD140PHXEA RD160PHXEA
* Specifications are subject to change without prior notice for product improvement
22
Line-Up & Specification
Product Line-up – Model Codes
Model codes for outdoor unit
1 2 3 4 5 6 7
- A2W Condition#1: (Heating) Water In/Out 30℃/35 ℃, Outdoor Air DB/WB 7℃/6℃; (Cooling) Water In/Out 23℃/18℃, Outdoor Air DB 35℃
- A2W Condition#2: (Heating) Water In/Out 40℃/45 ℃, Outdoor Air DB/WB 7℃/6℃; (Cooling) Water In/Out 12℃/7℃, Outdoor Air DB 35℃
- A2A Condition#3: (Heating) Indoor Air DB/WB 20℃/15 ℃, Outdoor Air DB/WB 7℃/6℃; (Cooling) Indoor Air DB/WB 27℃/19℃, Outdoor Air DB/WB 35℃/24℃
* Specifications are subject to change without prior notice for product improvement
Specification - 2010
Outdoor units (2/2)
ITEM UNIT RD060PHXEA RD070PHXEA RD080PHXEA RD110PHXEA RD140PHXEA RD160PHXEA
* Specifications are subject to change without prior notice for product improvement
Specification - 2010
Hydro units
ITEM UNIT NH080PHXEA NH160PHXEA
POWER SOURCE Ph/V/Hz 1P,230,50 1P,230,50
Capacity Cooling W 7,000 7,500 8,000 11,300 14,200 15,500
(A2W condition#2) Heating W 6,000 7,000 8,000 11,000 14,000 16,000
Operating Range Cooling ˚C 5~25 5~25
(Water) Heating ˚C 15~55 (H/P : 25~55) 15~55 (H/P : 25~55)
Cooling dB(A) 40 40
Sound Pressure
Heating dB(A) 35 35
Dimensions Net mm 850 x 510 x 315 850 x 510 x 315
(WxHxD) Gross mm 1024 x 412 x 564 1024 x 412 x 564
Net kg 45 48
Weight
Gross kg 55 58
Connecting Pipe Liquid Inch 3/8" 3/8"
[Refrigerant] Gas Inch 5/8" 5/8"
Connecting Pipe Liquid Inch BSPP male 1 1/4" BSPP male 1 1/4"
[Water] Gas Inch BSPP male 1 1/4" BSPP male 1 1/4"
Flow rate kg/min 17.0 20.5 23.0 31.5 40.1 45.9
Water Pump
E.Static Pressure kPa 53 51 45 64 59 54
Electric Heater Input power W 4,000 6,000
Expansion Vessel Volume Liter 8.0 8.0
Pressure Relief valve Relief Pressure bar 2.9 2.9
Air purge valve Size Inch BSPP male 3/8" BSPP male 3/8"
Service valve Size Inch BSPP male 1 1/4" BSPP male 1 1/4"
Total Water Volume Liters 5.0 5.5
Back up Boiler - 230VAC 1A (DO) 230VAC 1A (DO)
Room Thermostat - 230VAC 1A (DI) 230VAC 1A (DI)
External Control
Solar Pump - 230VAC 1A(DI) 230VAC 1A(DI)
Valves, 2/3way - 230VAC 1A(DO) 230VAC 1A(DO)
Specification - 2010
DHW tanks
Standard Solar Connected
ITEM Unit
NH200WHXEA NH300WHXEA NH200WHXES NH300WHXES
Material quality AISI 444 / DIN 1.4521
Pressure vessel
Volume capacity Liters 198 287 198 287
Capacity kW 2.6
Electric element Material INCOLOY 825
Voltage Ph/V/Hz 1P, 230~, 50
Material quality Duplex LDX 2101
Heating coil
Heating Area ㎡ 0.71
Material quality - - Duplex LDX 2101 Duplex LDX 2101
Heating coil for Solar
Heating Area ㎡ - - 0.47 0.47
Material quality Polyurethane form
Insulation
Thickness mm 40
Insulation jacket Material quality Epoxy-coated mild steel - white
Diameter mm 585 585 585 585
Dimensions overall
Height mm 1130 1580 1130 1580
Cold water inlet Inch 3/4" FBSP
Hot water outlet Inch 3/4" FBSP
Connections Recirculation mm ø 22 mm straight tube (for compression fitting)
Flow & return mm 2 x 3/4" female
Sensor pocket(s) mm ø 8.05 mm inside, 1/2" thread
Weight Overall kg 47 61 51 65
Max. Water temperature ℃ 70
Packaging Eco Foam - PUF
Other
Adjustable legs pcs 3
Specification - 2010
Indoor units - Slim duct
NOISE HIGH 31 32 32 33 33
dB(A)
(Sound Pressure) LOW 26 27 27 30 30
NOISE HIGH 31 31 35 40 41
dB(A)
(Sound Pressure) LOW 21 21 21 30 30
DIMENSION NET mm 825 X 285 X 189 825 X 285 X 189 825 X 285 X 189 1065X298X218 1065X298X218
(WxHxD) GROSS mm 900 X 349 X 252 900 X 349 X 252 900 X 349 X 252 1137X377X299 1137X377X299
NET kg 9.5 9.5 9.5 13.5 13.5
WEIGHT
GROSS kg 12 12 12 17.5 17.5
Liquid mm 1/4" (φ6.35) 1/4" (φ6.35) 1/4" (φ6.35) 1/4" (φ6.35) 3/8" (φ9.52)
Connecting Pipe Gas mm 1/2" (φ12.7) 1/2" (φ12.7) 1/2" (φ12.7) 1/2" (φ12.7) 5/8" (φ15.88)
Drain mm 18 18 18 18 18
Specification - 2010
Indoor units - Neo forte
POWER SOURCE PhV/Hz 1P, 230~,50 1P, 230~,50 1P, 230~,50 1P, 230~,50 1P, 230~,50
COOL W 2,200 2,800 3,600 5,600 7,100
CAPACITY
HEAT W 2,500 3,200 4,000 6,300 8,000
COOL 25 25 30 45 50
POWER CONSUMPTION W
HEAT 25 25 30 45 50
COOL 0.16 0.16 0.18 0.27 0.30
R/CURRENT A
HEAT 0.16 0.16 0.18 0.27 0.30
NOISE HIGH 32 32 36 40 41
dB(A)
(Sound Pressure) LOW 23 23 23 30 30
Load
E T B T
Pump #2 2 40℃
Supply Header
3
Return Header
E Under-Floor Heating Coils
Mixing Tank
[Application #1] [Application #4]
Zone Thermostat Differential Pressure
& 2-way Valve bypass valve
Outdoor unit Hydro-unit
A2W Temperature Range
No heat pump
10
-20
5 25 15 25 44 55
Leaving water temp. (℃) Leaving water temp. (℃)
Water Temp. (℃) Water Flow rates (LPM) Air Temp. (℃, DB/WB)
Min Std Max Min Std Max Min Std Max
Cooling 5 - 25
Controller
Heating 15 - 55
Inlet - 23 (12*2) 30
Cooling 10/- 35/24 46/28
Outlet 5 18 (7*2) 25
16 (12*1) ∆ 5℃ 58 (48*1)
Inlet 10 30 (40*2) - 7/6
Heating -20/- 35/24
Outlet 25(15*4) 35 (45*2) 55 (-7/-8*3)
*1 : 11~16kW. (6~8kW) *2 : Eurovent Test Condition #2 *3 : NF PAC low temp. heating 4 : Back up heater only
Operation Range
DHW(Domestic Hot Water) Tank
Sanitary Mode
43
35
-20
30 44 55 70
Leaving water temp. (℃)
Water Temp. (℃) Water Flow rates (LPM) Air Temp. (℃, DB/WB)
-
Min Std Max Min Std Max Min Std Max
Controller DHW 30 - 70
both Hydro unit and DHW tank should be installed in a mechanical room with ambient temperature 0~40℃
Cycle Components - Outdoor
Outdoor Units - 11/14/16kW (Same with Conventional CAC)
Cycle Diagram - Outdoor
Outdoor Units - 11/14/16kW (Same with Conventional CAC)
P P
E O E O
F F
G G
D D
H
C I C
B L
S
M N M N
K K
A A
Q
J J
11/14/16 kW 6/7/8 kW
Cycle Diagram - Outdoor
Outdoor Units - 11/14/16kW (Same with Conventional CAC)
510 315
connection
510
6 Manometer -
9
7 Controller -
315
8
8 Drain hole 14 mm
48 40
104 103 78
Service valve BSPP 1 1/4" 9 Service valve BSPP 1 ¼"
Cycle Diagram – Hydro Unit
Hydro Unit - 16kW
5) Heater Vessel
[2+4 kW, Incoloy 800]
Tw3 8) Flow Switch Tw2
[Min Flow 12LPM↑] 4) EEV
Tr1 Ref' In
Tr2
Tw1
1) Service Valve
[1 ¼” BSPP male]
Water Out Water In
Cycle Components – Hydro Unit
Hydro Unit - Base 16kW
System Configuration
Domestic Hot water Tank
35~45℃
20℃, 5~6 bar
manual(OSO)
50℃, 2 bar
Tundish
50℃, 0.3 bar DHW TANK
20℃, 2~3 bar