Professional Documents
Culture Documents
KSB Amarex N Literature
KSB Amarex N Literature
Amarex N
50 Hz
DN 50 - DN 100
All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
edited or processed for any other purpose, nor otherwise transmitted, published or made available to
a third party without the manufacturer's express written consent.
Contents
3
Waste Water
Submersible Motor Pump
1) For short periods (3 to 5 minutes or until the temperature guards trip) UL and WL models can be operated at up to 80 °C.
2) In countries stipulating explosion-proof units for handling sewage with faeces, motor version YL must be used.
4 Amarex N
Waste Water
Submersible Motor Pump
D impeller Materials
Overview of available materials
Open, diagonal Suitable for the following
single-vane fluids: Component Material
impeller fluids containing solid Casing JL 1040
(impeller type D) substances and long fibres Intermediate casing JL 1040
Impeller JL 10403)
Cutter (only Amarex N S) 1.2080 (K100)
F impeller Shaft 1.4021
Mechanical seal (motor end) Carbon/Al2O3
Free-flow Suitable for the following
Mechanical seal (pump end) SiC/SiC
impeller fluids:
Screws/bolts A2
(impeller type F) fluids containing solids and
Sealing elements NBR
stringy material as well as
fluids with entrapped air or
gas
Product benefits
D and F impellers are suitable for handling the following ▪ Easy and fast installation/removal with polarised,
fluids: absolutely watertight cable and KSB plug connection
ensuring correct installation
▪ Activated sludge
▪ Motor absolutely watertight, also in the event of damage
▪ Digested sludge
to the cable sheath, with individually stripped, tinned and
▪ Heating sludge resin-sealed conductors
▪ Mixed water ▪ Highest operating reliability with optimum motor
selection for operating mode S1, thermal class F,
▪ Raw waste water
explosion-proof variant in Ex d IIB T4 Gb
▪ Raw sludge
▪ Long service life with shaft made of corrosion-resistant
▪ Recirculated sludge stainless steel
▪ Zero maintenance, ideal for continuous duty, with long-
S impeller life bearings sealed on both sides, grease-packed for life
▪ Environmentally friendly, non-toxic, food-approved oil
Impeller with Suitable for the following
cutter fluids: ▪ Significant reduction of energy costs by optimised
(impeller type S) faeces, domestic sewage and hydraulic system and high efficiency
waste water containing long ▪ Absolutely reliable and non-clogging design with
fibres optimised cutter (S impeller).
S impellers are suitable for handling the following fluids: ▪ No risk of leakage with close-coupled pump design
▪ Domestic waste water ▪ Stationary pump sets easy to install and remove with
automatic, bolt-free connection; leakage prevented by
▪ Grey water elastic sealing elements
▪ Waste water with faeces ▪ Ease of service with wetted bolts made of stainless steel,
Standard bearings which are easy to undo even after years of operation
▪ Grease-lubricated bearings sealed for life ▪ Two bi-directional mechanical seals with oil reservoir filled
with ecologically acceptable oil provide double safety
▪ Maintenance-free
▪ Well suited for mechanical seal with covered spring for
Reinforced bearings (optional, only for S impeller)
abrasive and aggressive fluids
The following hydraulic system/motor combinations can be
▪ Only one set of spare parts for all pump sizes thanks to
equipped with reinforced bearings:
modular system
Reinforced bearings
Size of hydraulic system Motor size and number of
poles Certifications
Amarex N S 50-172 002, 012, 022
(motor version YL) Label Effective in: Note
Amarex N S 50-222 032, 042 Europe Suitable for plants to Standard
(motor version YL) EN 12050-1
Europe Amarex N DN 50 - DN 100
Pump-end bearings: BMW (test report) Nos.:
▪ Grease-lubricated bearing sealed for life 0420266-01 to 05
Drive
▪ Three-phase asynchronous squirrel-cage motor
Explosion-proof pump sets comply with Ex dc IIB type of
protection.
Amarex N 5
Waste Water
Submersible Motor Pump
Product overview / selection tables detailed advice is available from our specialist department.
Make use of our laboratory's wealth of experience when
selecting materials.
Table of fluids handled
The table below for your guidance is based on KSB's long-
standing experience. The data are standard values and are not
to be considered as generally binding recommendations. More
4) For any fluids which are not listed in this table contact KSB.
5) The first impeller type listed should be given preference.
6) ATV = German regulatory body for waste water management
7) Severe hydroabrasive wear occurs if solids contents of approx. 0.5 g/l or higher are combined with circumferential speeds
exceeding 20 m/s or low-flow conditions to the left of the duty point.
6 Amarex N
Waste Water
Submersible Motor Pump
4) For any fluids which are not listed in this table contact KSB.
5) The first impeller type listed should be given preference.
8) The material variants required highly depend on the operating hours, rotational speed and flow velocity.
Amarex N 7
Waste Water
Submersible Motor Pump
9) In countries stipulating explosion-proof units for handling sewage with faeces, motor version YL must be used.
10) Maximum switching frequency: 30 starts per hour
8 Amarex N
Waste Water
Submersible Motor Pump
Standard variants
Size S impeller D impeller F impeller
Amarex N S Amarex N D Amarex N F 50-...
50-172/... 80-220/... Amarex N F 65-...
Amarex N S Amarex N D Amarex N F 80-...
50-222/... 100-220/... Amarex N F 100-...
Material variants G G G1 G2 GH
Number of motor poles
2-pole - - 50-170/...
50-220/...
65-170/...
4-pole - - 65-220/...
80-220/...
100-200/...
Shaft material
Material 1.4462 + C45 N ✘ ✘ ✘
Motor
Voltage 230 V, 415 V, 500 V, 690 V
Monitoring equipment
Leakage sensor in the motor ✘ ✘ ✘
space11)
Suction flange
Drilled to DIN/ISO PN16 or ASME - - ✘
150 lb
Sealing elements
Elastomers: O-rings and flange ✘ ✘ ✘
gaskets made of Viton, lower
mechanical seal with Viton
gaskets
Shaft seal: special mechanical ✘ ✘ ✘
seal (mechanical seal with
covered spring HJ977)12)
Power cables
Standard rubber-sheathed cable ✘ ✘ ✘
(H07RN8-F 7G1.52); for versions
ULG, YLG, WLG13)
Standard rubber-sheathed cable ✘ ✘ ✘
(H07RN8-F 8x1.52) for pump with
leakage sensor13)
TEHSITE power cable (8G1.5) for ✘ ✘ ✘
pump with or without leakage
sensor, for versions ULG, YLG,
WLG14)
Shielded rubber-sheathed cable ✘ ✘ ✘
(S07RC4N8-F-8G1.5) for pump
with or without leakage sensor,
for versions ULG, YLG, WLG
operated with a frequency
inverter14)
Coating Environmentally-friendly KSB standard coating (two-component epoxy paint), colour RAL 5002,
film thickness = 300 µm
Installation (⇨ Page 37)
Stationary, with guide hoop Installation depths 1.5 m/1.8 m/2.1 m
Stationary, with single guide rail Installation depth 6.0 m
Stationary, with twin guide rail Installation depth 6.0 m
Stationary, with guide wire Installation depth 9.5 m
Transportable Installation depth 4.5 m
Amarex N 9
Waste Water
Submersible Motor Pump
Material variants
Overview of material variants for standard models
Component S impeller D impeller F impeller
Amarex N S 50-172/... Amarex N D 80-220/... Amarex N F 50-...
Amarex N S 50-222/... Amarex N D 100-220/... Amarex N F 65-...
Amarex N F 80-...
Amarex N F 100-...
G G G
Casing JL 1040 JL 1040 JL 1040
Intermediate casing JL 1040 JL 1040 JL 1040
Impeller JL 1040 JL 1040 JL 1040
Cutter 1.2080.02 (K100) - -
Shaft 1.4021 1.4021 1.4021
Mechanical Drive end Carbon/Al2O3 Carbon/Al2O3 Carbon/Al2O3
seal Pump end SiC/SiC SiC/SiC SiC/SiC
Screws/bolts A2 A2 A2
Elastomer seals NBR NBR NBR
10 Amarex N
Waste Water
Submersible Motor Pump
Technical data
Impeller Size Motor version P1 P2 IN IA Fluid [kg] Mat. No.
diameter temperature
[kW] [kW] [A] [A] [°C]
120 S 50-172/002 LG-120 ULG 1,75 1,30 3,56 20 55 47 39100017
S 50-172/002 LG-120 YLG 1,75 1,30 3,56 20 40 47 39100018
S 50-172/002 LG-120 WLG 1,75 1,30 3,56 20 60 47
140 S 50-172/002 LG-140 ULG 1,75 1,30 3,56 20 55 47 39100019
S 50-172/002 LG-140 YLG 1,75 1,30 3,56 20 40 47 39100020
S 50-172/002 LG-140 WLG 1,75 1,30 3,56 20 60 47
160 S 50-172/012 LG-160 ULG 2,60 1,90 4,50 20 55 47 39100021
S 50-172/012 LG-160 YLG 2,60 1,90 4,50 20 40 47 39100022
S 50-172/002 LG-160 WLG 2,60 1,90 4,50 20 60 47
175 S 50-222/032 LG-175 ULG 4,00 3,10 7,00 50 55 58 39100041
S 50-222/032 LG-175 YLG 4,00 3,10 7,00 50 40 58 39100042
S 50-222/032 LG-175 WLG 4,00 3,10 7,00 50 55 58
190 S 50-222/042 LG-190 ULG 5,30 4,20 8,80 50 55 58 39100043
S 50-222/042 LG-190 YLG 5,30 4,20 8,80 50 40 58 39100044
S 50-222/042 LG-190 WLG 5,30 4,20 8,80 50 55 58
90 F 50-170/002 LG-90 ULG 1,75 1,30 3,56 20 55 41 39100045
F 50-170/002 LG-90 YLG 1,75 1,30 3,56 20 40 41 39100046
F 50-170/002 LG-90 WLG 1,75 1,30 3,56 20 60 41
107 F 50-170/002 LG-107 ULG 1,75 1,30 3,56 20 55 41 39100047
F 50-170/002 LG-107 YLG 1,75 1,30 3,56 20 40 41 39100048
F 50-170/002 LG-107 WLG 1,75 1,30 3,56 20 60 41
120 F 50-170/012 LG-120 ULG 2,60 1,90 4,50 20 55 42 39100049
F 50-170/012 LG-120 YLG 2,60 1,90 4,50 20 40 42 39100050
F 50-170/012 LG-120 WLG 2,60 1,90 4,50 20 60 42
130 F 50-170/022 LG-130 ULG 3,06 2,30 5,10 20 55 42 39100051
F 50-170/022 LG-130 YLG 3,06 2,30 5,10 20 40 42 39100052
F 50-170/022 LG-130 WLG 3,06 2,30 5,10 20 60 43
140 F 50-170/022 LG-140 ULG 3,06 2,30 5,10 20 55 43 39100053
F 50-170/022 LG-140 YLG 3,06 2,30 5,10 20 40 43 39100054
F 50-170/022 LG-140 WLG 3,06 2,30 5,10 20 60 43
130 F 50-220/032 LG-130 ULG 4,00 3,10 7,00 50 55 52 39100067
F 50-220/032 LG-130 YLG 4,00 3,10 7,00 50 40 52 39100068
F 50-220/032 LG-130 WLG 4,00 3,10 7,00 50 60 52
140 F 50-220/032 LG-140 ULG 4,00 3,10 7,00 50 55 52 39100069
F 50-220/032 LG-140 YLG 4,00 3,10 7,00 50 40 52 39100070
F 50-220/032 LG-140 WLG 4,00 3,10 7,00 50 60 52
150 F 50-220/042 LG-150 ULG 5,30 4,20 8,80 50 55 53 39100071
F 50-220/042 LG-150 YLG 5,30 4,20 8,80 50 40 53 39100072
F 50-220/042 LG-150 WLG 5,30 4,20 8,80 50 60 53
160 F 50-220/042 LG-160 ULG 5,30 4,20 8,80 50 55 53 39100073
F 50-220/042 LG-160 YLG 5,30 4,20 8,80 50 40 53 39100074
F 50-220/042 LG-160 WLG 5,30 4,20 8,80 50 60 53
170 F 50-220/042 LG-170 ULG 5,30 4,20 8,80 50 55 54 39100075
F 50-220/042 LG-170 YLG 5,30 4,20 8,80 50 40 54 39100076
F 50-220/042 LG-170 WLG 5,30 4,20 8,80 50 60 53
180 F 50-220/042 LG-180 ULG 5,30 4,20 8,80 50 55 54 39100077
F 50-220/042 LG-180 YLG 5,30 4,20 8,80 50 40 54 39100078
F 50-220/042 LG-180 WLG 5,30 4,20 8,80 50 60 53
120 F 65-170/032 LG-120 ULG 4,00 3,10 7,00 50 55 58 39100085
F 65-170/032 LG-120 YLG 4,00 3,10 7,00 50 40 58 39100086
F 65-170/032 LG-120 WLG 4,00 3,10 7,00 50 60 58
128 F 65-170/032 LG-128 ULG 4,00 3,10 7,00 50 55 58 39100087
F 65-170/032 LG-128 YLG 4,00 3,10 7,00 50 40 58 39100088
F 65-170/032 LG-128 WLG 4,00 3,10 7,00 50 60 58
136 F 65-170/032 LG-136 ULG 4,00 3,10 7,00 50 55 59 39100089
F 65-170/032 LG-136 YLG 4,00 3,10 7,00 50 40 59 39100090
F 65-170/032 LG-136 WLG 4,00 3,10 7,00 50 60 58
146 F 65-170/042 LG-146 ULG 5,30 4,20 8,80 50 55 59 39100091
Amarex N 11
Waste Water
Submersible Motor Pump
12 Amarex N
Waste Water
Submersible Motor Pump
Amarex N 13
Waste Water
Submersible Motor Pump
Characteristic curves
n = 2900 rpm
0 20 Q [IM.gpm] 40 60 80
35
10
15 η [%]
100
30 20
24
28
32
35.5
25
38 80
10
15 39.5
20
24 40.2
20
28
39.5
60
32
10
38
15 15 33.3
20
35.5
32 40
24
32
10 25.1
28 H [ft]
24 28
24
20 24 20
20
5
15 15 20
H [m]
ø120 ø140 ø160
0 0
0 5 Q [m³/h] 10 15 20
0 2 Q [l/s] 4 6
1.8
1.5 2.0
P [hp]
1.5
1.0
ø120 ø160
0.5
0 5 Q [m³/h] 10 15 20
K2563-52-14/0
Free passage = 6 mm
14 Amarex N
Waste Water
Submersible Motor Pump
0 20 Q [IM.gpm] 40 60 80
54
50
10 η [%]
15
20 150
24
28
32
34.5
40
38
10
15 40.5
20
42
24
42.3
28 100
30 42
40.5
32 38
32.4
H [ft]
34.5
20 32 32
28
28 50
24
24
20
10
20 ø190
15
H [m] 15
ø175
0 0
0 5 Q [m³/h] 10 15 20
0 2 Q [l/s] 4 6
3.5
3.0 4
P [hp]
2.5
2.0 ø190
P [kW]
ø175
1.5
0 5 Q [m³/h] 10 15 20
K2563-52-15/0
Free passage = 6 mm
Amarex N 15
Waste Water
Submersible Motor Pump
20 20 η [%]
31
60
37
20
40.5
31
42.5
37
15 20 40.5 Qmax
44
31 42.5
37 44.6
44
40.5
20 42.5 40
44.6 44
31 44
37 44
44.4 42.5
10 40.5
42.5 42.5
20 44 40.5 H [ft]
31 43.4 40.5
37 42.5
42.5 40.5 37
ø140
40.0
40.5 37 20
ø130
5 37
37
ø120
31
31
ø107
H [m]
ø90
0 0
0 10 Q [m³/h] 20 30 40 50
0 2 Q [l/s] 4 6 8 10 12
2.8
ø140
2 ø130
P [hp]
P [kW] ø120 2
1 ø107
1
ø90
0.2
0 10 Q [m³/h] 20 30 40 50
K2563-52-13/0
Free passage = 40 mm
16 Amarex N
Waste Water
Submersible Motor Pump
40
η [%]
20
120
30
35
20 37
30
42 Qmax
37 100
30 20 45
42
30
45
37 47 47
20
42 47.3
25 30 48.5
45 47 80
37 47 48.8
20
42 48.5
30 48.5
45
37 47 45
20 42 48.5 49.1
20 49.5 47
30 45 ø180
37 47 50.2 48.5
48.5 60
42 49.5 ø170
45 49.5 47
47 48.5
15 47 ø160 H [ft]
48.5 48.5
48.7
48.5 47
H [m] ø150
45 40
47
45
10 ø140
42
ø130
6 20
0 10 Q [m³/h] 20 30 40 50
0 5 Q [l/s] 10 15
6 ø180 8
ø170
ø160 6
4
ø150 P [hp]
P [kW] ø140 4
ø130
2
0.5
0 10 Q [m³/h] 20 30 40 50
K2563-52-04/0
Free passage = 40 mm
Amarex N 17
Waste Water
Submersible Motor Pump
20
η [%]
30
38
20
20 42
30
38 44.5
20 42 Qmax 60
30 44.5
46.5
38 46.5
20 42 47.5 47.0
30
15 44.5 H [ft]
38 47.7 46.5
20 42
30 45.9 47.5
44.5
38 46.5
44.5 40
20 42
45.9 44.5
30
44.5
38 44.5
10 44.5 42
42
45.1 42
42
44.1 44.5 42
H [m] ø158
38
42
38 ø152 20
42
38 ø146
5
38
ø136
ø128
ø120
1
0 20 Q [m³/h] 40 60 80
0 5 Q [l/s] 10 15 20 25
4.8
6
ø158
P [hp]
ø152
ø146
3 4
ø136
ø128
2
ø120
P [kW] 2
1
0 20 Q [m³/h] 40 60 80
K2563-52-05/0
Free passage = 65 mm
18 Amarex N
Waste Water
Submersible Motor Pump
n = 1450 rpm
10
η [%]
20
32
30
42
20 49
32 53
42
8 20 55.5
49
32
42 53 56.0
20 49
32 53 55.5
42 55.5
49 55.5
20 56.7
6 32 53 20
42 57.2 53
20 55.5 55.5
49
32 53 56.0
42 55.5 53 49
20 55.0 55.5 H [ft]
32 49
53 49
20
4 42
32 53 53 42
52.1 49
20 42 45.5 49 42
49
10
32 49 42
44.2 ø195
42 42
38.0 42 42 42 ø185
2 ø175
ø165
32 32 32 ø155
H [m] ø135 ø145
ø125
ø112
0 0
0 10 Q [m³/h] 20 30 40 50 60 70
0 5 Q [l/s] 10 15 20
1.7
1.5 ø195
2
ø185
P [hp]
1.0 ø175
ø165
P [kW] 1
ø155
ø145
0.5
ø135
ø125
ø112
0.1
0 10 Q [m³/h] 20 30 40 50 60 70
K2563-54-06/0
Free passage = 65 mm
Amarex N 19
Waste Water
Submersible Motor Pump
14
20 η [%]
20 40 40
12
40 50
20 50
58
40 58
50
10
58 62
20 61.5
62 62.4 30
40
50 62 Qmax
58 63.0
8
20 62
40 62 58
63.0
50 58
58 62
58
62
6 20
20 62.6 58 50
40 62
50 50
58 50
58
62.0 50 ø210 H [ft]
20 ø195
4 40 50
58 ø180
47.0
50 ø165 10
40 40 ø150
2
ø135
H [m]
ø120
0 0
0 20 Q [m³/h] 40 60 80 100 120 140
0 10 Q [l/s] 20 30 40
4.4
4
ø210
ø195
3 4
ø180
ø165 P [hp]
2
ø150
P [kW] 2
ø135
1
ø120
0.2
0 20 Q [m³/h] 40 60 80 100 120 140
K2563-54-07/0
Free passage = 76 mm
20 Amarex N
Waste Water
Submersible Motor Pump
40
12
20
η [%]
30
36
41
20
30 46
36
10 41 50
20 46 52.5
30 30
36 50
41
52.5 55 Qmax
46
8 20 50 55.6
30 55
36 52.5
41 55.2
55
46 55
54.0
20
30 50 52.5 20
6 36 52.5
41 52.5
51.1 50
46 50 50
50 46
20 30 46 H [ft]
36 49.3 46
41 46
4 41
46 41 41
20 45.1 41
30 41 36
36 36 ø210 10
38.1 41 36 ø195
36 36 ø180
2 ø165
30 30
ø150
20
H [m] ø135
ø120
0 0
0 20 Q [m³/h] 40 60 80 100 120 140 160 180
0 10 Q [l/s] 20 30 40 50
4.4
4 ø210
ø195
ø180
3 4
ø165
P [hp]
2 ø150
P [kW] ø135 2
ø120
1
0.2
0 20 Q [m³/h] 40 60 80 100 120 140 160 180
K2563-54-08/0
Amarex N 21
Waste Water
Submersible Motor Pump
40
12
η [%]
32
43
10 50
32
Qmin
57 30
43 61
8 32
50 66
43 68.5
57
69.1
6 50 20
61
68.5
61.8
32 66
61 H [ft]
56.0
61
4
43 57 57
44.0 50 10
50
50
43
43 43
43
2
32 ø190
32
ø168 ø180
H [m]
ø154
0 0
0 20 Q [m³/h] 40 60 80 100 120 140
0 10 Q [l/s] 20 30
2.0
ø190
1.5 2
ø180
ø168
P [hp]
1.0
ø154
P [kW] 1
0.5
0 20 Q [m³/h] 40 60 80 100 120 140
K2563-54-11/0
Free passage = 65 mm
22 Amarex N
Waste Water
Submersible Motor Pump
16
η [%]
14
53
57 40
12
53
60 Qmin
57
60 64
10
67.5
H [ft]
53 64
70
8 57
67.5 71.0
68.4 70
60
67.5 67.5 20
6
61.2
64 64
60
60 60
57
57
4 57 53
53
53
H [m] ø220
ø209
2 ø195
1
0 20 Q [m³/h] 40 60 80 100 120 140 160 180 200
0 20 Q [l/s] 40
3.5
ø220
3.0 4
ø209
P [hp]
2.5
3
ø195
2.0
P [kW]
1.5 2
Free passage = 76 mm
Amarex N 23
Waste Water
Submersible Motor Pump
Connections
Discharge line connections at the duckfoot bend
Flanged connection (DN 50/DN 65) Threaded connection in the flange Clamped connection (DN 50/DN 65)
(DN 50/DN 65)
P27 P8
P2 / P4
P2 / P4
P2 / P4
For standard pipes to DIN 2440 / DIN 2441 For standard pipes to DIN 2440 /
▪ With outside diameter of 60.3 mm, DIN 2441 / DIN 2448
steel for DN 50 ▪ With outside diameter of 60.3 mm,
▪ With outside diameter of 63 mm, PVC steel for DN 50
(ISO 3606) for DN 50 ▪ With outside diameter of 63 mm, PVC
▪ With threaded flange DN 50 - G 2″ (ISO 3606) for DN 50
▪ With outside diameter of 76.1 mm, ▪ With outside diameter of 76.1 mm,
steel for DN 65 steel for DN 65
▪ With outside diameter of 75 mm, PVC ▪ With outside diameter of 75 mm, PVC
(ISO 3606) for DN 65 (ISO 3606) for DN 65
24 Amarex N
Waste Water
Submersible Motor Pump
L2
b2
DN
2) e2
C2
Dimensions [mm]
DN DN319) C2 L2
1) 65 65 135 135
80 80 135 135
100 100 120 175
a2
DN2
DN3
DN1 DN 50
L2
b3 PN 16
C2
1) Lowest switch-off point for automatic operation
2) Minimum submergence for continuous operation
Dimensions [mm]
Pump dimensions [mm]
DN DN3 C2 L2
Size Pump
50 G 2″ 78 58
DN1 DN2 a2 18) b2 b3 e2 f218) R2
50–172 S - 50 547 322 293 180 152 207
Pump flange DN₂
50–170 F 50 50 547 322 293 180 152 207
50–222 S - 50 609 336 307 180 155 203 DN 50 and 65 DN 80 and 100
50–220 F 50 50 609 336 307 180 155 203 ISO 7005 PN 16 ISO 7005 PN16
65–170 F 65 65 653 367 338 210 164 248 DIN 2501 PN 16 DIN 2501 PN16
65–220 F 65 65 593 353 347 210 163 253 Hf kf
5
9,
80–220 F 80 80 672 386 392 230 187 249
xR
Z
f
80–220 D - 80 672 386 392 230 187 249 9,5
Zfx R
22°30‘
DN
100–220 F 100 100 698 383 390 230 207 277 2
Df
‘
22°30
Df
Hf
Connection elbow with flange/hose connection (P13)
D1
Dimensions of the pump flange in [mm]
Pump size Flange
Hf kf Df Zf
DN
Amarex N 25
Waste Water
Submersible Motor Pump
Amarex N 50, stationary model with guide wire, single-rail and guide hoop arrangement, straight claw
DN 3 = DN 50: DIN ISO ASME = standard
Guide wire arrangement Single guide rail arrangement Guide hoop
arrangement
60
50
B
Ø10
5
E
B
15
100 a)
12
20 12 50
C 85 76 85
Ø10
5
k1 79
E
15
12
20
b1
12
2) Ø33,7 x 3,2
DIN 2440
DIN 2448
NF A 49-004
1800 b)
NF A 49-005 3)
NF A 49-111
DN3 NF A 49-117 125
a1
125 DN3
R3
113 DN3
1)
20
A A A A A A
g
R1
125
f1
60
Ø10
h1
DN1
l1 125
1) Lowest switch-off point for automatic operation 2) Minimum submergence for continuous operation
3) Not included in KSB's scope of supply a) Minimum
b) Maximum
120
100
P a)
80
NF A 49-111
d
NF A 49-117
Na
)
25
185 G
Pump flange DN₂ Flanged elbow DN₃
ISO 7005 PN10/16 ISO 7005 PN 10 - PN16
DIN 2501 PN10/16 DIN 2501 PN10 - PN16
ASME 2″
ASME B16.1 class 125
Ø1
2
DN 5
50 50 4 x 18+2
125 PN
10-
PN
16
R 9,5 Ø102
Zf x
120
140
0,5
5 Ø12 E 2″
Ø12 DN ASM
130
2
26 Amarex N
Waste Water
Submersible Motor Pump
Amarex N 50, stationary model with guide wire, single-rail and guide hoop arrangement, inclined claw
DN 3 = DN 50: DIN ISO ASME = standard
Guide wire arrangement Single guide rail arrangement Guide hoop
arrangement
B
60 50
Ø10
5
B E
15
12
20 50
10 a)
12
85
E 76 85
Ø10
C
5
79
15
k1
12
20
DIN 2440
2) b1 12
DIN 2448 Ø33,7 x 3,2
NF A 49-004
NF A 49-005
NF A 49-111
3)
NF A 49-117
1800 b)
125
a1
DN3
R3
g
g
125
f1
125
h1
A A A A A A
60
60
Ø10
Ø10 125
125
l1 2563:129
1) Lowest switch-off point for automatic operation 2) Minimum submergence for continuous operation
3) Not included in KSB's scope of supply a) Minimum
b) Maximum
120
100
P a)
80
NF A 49-111
d
NF A 49-117
Na
)
25
185 G
Pump flange DN₂ Flanged elbow DN₃
ISO 7005 PN10/16 ISO 7005 PN16
DIN 2501 PN10/16 DIN 2501 PN16
ASME 2″
ASME B16.1 class 125
Ø1
2
DN 5
50 50 4 x 18+2
125 PN
10-
PN
16
R 9,5 Ø102
Zf x
120
140
0,5
5 Ø12 E 2″
Ø12 DN ASM
130
2
Amarex N 27
Waste Water
Submersible Motor Pump
Amarex N 50, stationary installation with twin guide rail arrangement, inclined claw
DN 3 = DN 50: DIN ISO ASME = standard
Twin guide rail arrangement
E 76 E 70
DIN 2440 50
12
DIN 2448
NF A 49-004
Ø10
NF A 49-005 85
55
NF A 49-111
NF A 49-117
12
3)
D k1
2) b1 50
113
1) DN3
a1
R3
A A
R1
g
f1
h1
DN1
Ø10 125
60
l1
1) Lowest switch-off point for automatic operation 2) Minimum submergence for continuous operation
3) Not included in KSB's scope of supply a) Minimum
100
P a)
NF A 49-005
80
NF A 49-111
N a)
25 NF A 49-117
185
0,5
Ø12 E 2″
ASM
130
28 Amarex N
Waste Water
Submersible Motor Pump
Amarex N 65, stationary model with guide wire, single-rail and guide hoop arrangement
DN 3 = 65/65: DIN ISO ASME = standard - DN 3 = 65/80: DIN ISO = standard, ASME = variant
Guide wire arrangement Single guide rail arrangement Guide hoop
arrangement
B
60 50 50
Ø10
76 85 E
Ø10
B E
5
15
C
100 a)
12
20 12
15
85
12
20
12
k1 Ø33,7 x 3,2
b1 79
2)
3)
DIN 2440
DIN 2448
DN3 NF A 49-004
165
1800 b)
NF A 49-005 153 165 DN3
1) NF A 49-111
20
a1
R3
NF A 49-117
A A A A A
g
R1
165
A
f1
h1
60
DN1
Ø10
l1
1) Lowest switch-off point for automatic operation 2) Minimum submergence for continuous operation
3) Not included in KSB's scope of supply a) Minimum
b) Maximum
Ø65
DN2
Df
Df
gf
gf
kf
kf
m
120
P a)
120
140
85
Zf x 21 Zf x 21
25
150 150
215
a)
N
Amarex N 29
Waste Water
Submersible Motor Pump
25
25
Ø80
Ø80
gf
gf
Df
Df
kf
kf
Zf x 19
Zx
f 18
D
30 Amarex N
Waste Water
Submersible Motor Pump
DIN 2440 E 76 E 70
DIN 2448 50
NF A 49-004
12
NF A 49-005
Ø10
85
NF A 49-111
55
NF A 49-117 Ø33,7 x 3,2
12
3)
k1
2) b1
50
153
DN3
R3
1)
a1
A A
g
R1
f1
h1
DN1 10 165
60
l1
1) Lowest switch-off point for automatic operation 2) Minimum submergence for continuous operation
3) Not included in KSB's scope of supply a) Minimum
12
Ø65
Ø65
DN2
Df
Df
gf
gf
kf
kf
m
P a)
120
120
140
85
Zf x 21 Zf x 21
25
150 150
215
)
Na
Amarex N 31
Waste Water
Submersible Motor Pump
25
25
Ø80
Ø80
gf
gf
Df
Df
kf
kf
Zf x 19
Zx
f 18
D
32 Amarex N
Waste Water
Submersible Motor Pump
Amarex N 80 and 100, stationary installation with guide wire and single guide rail arrangement
DN 3 = 80/80: DIN ISO = standard, ASME = variant - DN 3 = 80/100 or 100/100: DIN ISO ASME = standard
Guide wire arrangement Single guide rail
arrangement
60 60 85
E
B B 50
Ø10
50
Ø10
5
E
12
5
15
12
85 20
100 a)
12
15
20 12
Ø 60,3 x 3,6
C 165
3)
DIN 2440
DIN 2448
k1 NF A 49-004
2)
b1 NF A 49-005
NF A 49-111
NF A 49-117
G
G1
1) DN3 DN3
a1
R3
g
R1
A H
A A H
A
f1
h1
DN1
ØK
l1
1) Lowest switch-off point for automatic operation 2) Minimum submergence for continuous operation
3) Not included in KSB's scope of supply a) Minimum
d
D
B
P a)
4″
a) 18
E N Z fx
A
Ø80
gf
Df
kf
DN
gf
Df
kf
3
Zf x R9,5
Amarex N 33
Waste Water
Submersible Motor Pump
3
DN
gf
kf
Df
gf
Df
kf
19
Z fx
Zx
f 19
34 Amarex N
Waste Water
Submersible Motor Pump
Amarex N 80 and 100, stationary installation with twin guide rail arrangement
DN 3 = 80/80: DIN ISO = standard, ASME = variant - DN 3 = 80/100 or 100/100: DIN ISO ASME = standard
Twin guide rail arrangement
E 86 E 70
50
DIN 2440
12
DIN 2448
NF A 49-004
55
NF A 49-005
Ø10
85
NF A 49-111
12
NF A 49-117
3)
D
k1
2) 82
b1
G1
1)
DN3
a1
R3
A A
R1
H
f1
h1
DN1 Ø18
110
l1
1) Lowest switch-off point for automatic operation 2) Minimum submergence for continuous operation
3) Not included in KSB's scope of supply a) Minimum
b) Maximum
A-A D
O a)
C
)
Na
m
DN2
P a)
d
D
D
B
E
A
Amarex N 35
Waste Water
Submersible Motor Pump
25
ASME B16.1 class 125
4″
18
Ø100
3
Z fx
DN
gf
kf
Df
gf
Df
kf
19
Ø80
Z fx
gf
Df
kf
DN Zx
f 1 9
gf
Df
kf
3
Zf x R9,5
36 Amarex N
Waste Water
Submersible Motor Pump
Installation types
Overview of installation types
Installation type S - stationary wet installation
P7 P7
P1
P2 P7 P1 P1
P4
P4
P5
P5
P5
Guide hoop arrangement Guide wire arrangement Single guide rail arrangement
P1: pump P1: pump P1: pump
P2: installation parts for guide P4: installation parts for guide P4: installation parts for single
hoop arrangement (Amarex N wire arrangement, installation guide rail arrangement
50 and 65 only), depth = 4.5 m P5: claw
installation depth = 1.5 m / P5: claw P7: chain and shackle,
1.8 m / 2.1 m P7: chain and shackle, length = 5 m
P5: claw length = 5 m
P7: chain and shackle,
length = 2 m
P7
P7
P1
P1
P4
P5
P6
Amarex N 37
Waste Water
Submersible Motor Pump
Notes on installation
P18
P1 P1 P1
P17
P17 P27 P17 P18
P14
P14
P27
P27
P6 P6
P6
P19
P19
P1
P1
P20 P1
P16
P15 P20 P25 P15 P16 P20 P19
P26 P13
P25
P14
P25
P6 P6
P6
38 Amarex N
Waste Water
Submersible Motor Pump
P22 P22
P7 P7
P21 P21
P1 P1
P8/P27 P14
P27
P4
Suggestion 1 Suggestion 2
Single-pump station Single-pump station for 1.5 m installation depth
Flanged duckfoot bend Direct connection to discharge pipe (suspended installation)
P4
P22a) P22a)
P24 P24
P21a) P21a)
P23 P23
P7
P7
P1 ≥ DN 1
P8/P27a) P1
P4
Suggestion 3 Suggestion 4
Either with guide wire, single guide rail or twin guide rail Either with guide wire, single guide rail or twin guide rail
arrangement arrangement
Single-pump station for 4.5 m installation depth Dual-pump station for 4.5 m installation depth
Flanged duckfoot bend Flanged duckfoot bend
a) DN 50 only
Amarex N 39
Waste Water
Submersible Motor Pump
Dimensions
Guide wire arrangement
Amarex N 50, 65, 80, 100
DN2
G
K
N1
≥D
≥ DN 1
ØD
ØA
O
Ma)
Na)
Single-pump station for 4.5 m installation depth Dual-pump station for 4.5 m installation depth
Flanged duckfoot bend Flanged duckfoot bend
a) minimum
Dimensions [mm]
Amarex N ØA B ØD E G K L M N O DN 1 DN2
S 50-172 / 1 pump 625 165 1000 - 75 150 42 - - - 50 50
F 50-170 2 pumps - 235 1000 300 75 150 - 550 700 200 50 50
S 50-222 / 1 pump 625 165 1000 - 75 150 42 - - - 50 50
F 50-220 2 pumps - 235 1000 300 75 150 - 550 700 200 50 50
F 65-170 / 1 pump 625 175 1000 - 180 260 92 - - - 65 65
F 65-220 2 pumps - 360 1200 600 180 260 - 550 1000 135 65 65
F 80-220 / 1 pump 625 200 1000 - 180 260 25 - - - 80 80
D 80-220 2 pumps - 320 1200 600 180 260 - 600 1000 168 80 80
F 100-220 1 pump 625 200 1000 - 190 300 65 - - - 100 100
2 pumps - 320 1200 600 190 300 - 600 1000 128 100 100
40 Amarex N
Waste Water
Submersible Motor Pump
E63
E60
20) Optional
21) Optional
Amarex N 41
Waste Water
Submersible Motor Pump
Accessories
42 Amarex N
Waste Water
Submersible Motor Pump
Conversion parts
Parts for conversion to twin guide rail DN 50/DN 65 39022984 1.4
arrangement, consisting of: mounting DN 80/DN 100 39022987 2.5
bracket, stainless steel screws/bolts, adapter,
anchor bolts
Note: required for conversion of guide hoop,
guide wire or single guide rail arrangement
to twin guide rail arrangement
Note: for twin guide rail arrangements a claw
is mandatory.
Amarex N 43
Waste Water
Submersible Motor Pump
100
50
65
80
P8 Flange for pipe coupling PN 10, at the flanged DN 50/R2" pipe ✘ - - - 19551111 1.2
elbow, mating dimensions to PN 16 DN 65/R2½" pipe - ✘ - - 39020184 1.2
P9 PVC adapter for hose connection, with 1 hose clip, R2" ✘ - - - 11191498 0.3
plastic hose of inner diameter 63 item 19
Connection elbow with flanges PN 16, DIN 2501 (to DN 65/65 - ✘ - - 00265480 11
be used for flange connections item 25 / item 26), DN 65/80 - ✘ - - 25198402 8
grey cast iron DN 80/80 - - ✘ - 11150856 10
DN 100/100 - - - ✘ 25145802 14.4
P15 Storz rigid coupling with flange, to DIN 2501, drilled DN 65/B 75 - ✘ - - 18040148 3.5
to PN 16 (to be used for flange connections item DN 80/B 75 - - ✘ - 18072642 3.5
25 / item 26), aluminium/steel DN 100/A 110 - - - ✘ 18060162 5
P16 Storz hose coupling, aluminium alloy C 52 (DIN 14321) ✘ - - - 00524551 0.3
2 hose clips, item 20, are required for hose B 75 (DIN 14322) - ✘ ✘ - 00520454 0.7
mounting (for plastic hoses B 75 and A 110, item 19) A 110 (DIN 14323) - - - ✘ 00522313 1.5
P17 Storz rigid coupling with external thread, DIN ISO C 52/G 2 A ✘ - - - 00524370 0.2
228/1 B 75 - G 2½ - ✘ - - 00524371 0.4
P18 Plastic hose DN 50, DIN 14811, with integrated C C 52-5 m ✘ - - - 00522262 2.3
couplings C 52-10 m ✘ - - - 00522263 4.2
C 52-20 m ✘ - - - 00522264 5.7
P19 Plastic hose Inside diameter 5m ✘ - - - 39018688 1.7
Without coupling, DIN 14 811 63 10 m ✘ - - - 39018689 3.4
20 m ✘ - - - 39018690 6.8
B 75 5m - ✘ ✘ - 39019064 2
20 m - ✘ ✘ - 39019066 8
30 m - ✘ ✘ - 39019071 12
Inside diameter 5m - - ✘ - 39018691 2.2
80 10 m - - ✘ - 39019062 4.3
A 110 5m - - - ✘ 39019067 4.7
10 m - - - ✘ 39019068 9.3
30 m - - - ✘ 39019070 27.9
44 Amarex N
Waste Water
Submersible Motor Pump
100
50
65
80
P20 Hose clip DIN 3017, chrome steel B 5023) ✘ - - - 39000515 0.02
5
B 75 - ✘ ✘ - 00109515 0.04
AL 110 - 120 B24) - - - ✘ 00520853 0.1
P21 RK swing check valve Rp 2 ✘ - - - 01009773 0.5
Plastic, EN 12 050-4, with internal thread ISO 7/1,
full port and drain plug; cannot be used for
pumped drainage
P22 Socket gate valve CuZn PN 10-12 DIN 3352 Rp 2 ✘ - - - 00411503 1.1
Rp 2½ - ✘ - - 39000507 1.7
P23 KSB swing check valve, grey cast iron DN 65 - ✘ - - 48829253 16.2
With full port, backwash device, flanges drilled to DN 80 - - ✘ - 48829254 21.5
DIN 2501, PN 16 (not for lifting units) DN 100 - - - ✘ 48829255 29
P24 ECOLINE GTR-16P gate valve, grey cast iron, PN 16, DN 65 - ✘ - - 49709579 15
flanges drilled to ISO 7005/DIN 2501 DN 80 - - ✘ - 49709580 22
DN 100 - - - ✘ 49709581 26.5
P25 Set of installation accessories for a flange connection, discharge nozzle; ✘ - - - 39021944 0.8
item 13, 14 or 15 - ✘ - - 19551115 0.8
Consisting of: 4 hexagon head bolts with nuts and 1 sealing element - - ✘ - 19551100 0.8
- - - ✘ 19551113 0.8
P26 Set of installation accessories for a flange connection, - - ✘ - 19551114 0.8
Consisting of: 8 hexagon head bolts with nuts and 1 sealing element - - - ✘ 19551116 0.8
P27 Threaded flange for guide hoop arrangement (P2) DN 50/Rp 2 ✘ - - - 19551353 2
and guide wire arrangement (P4) DN 65/Rp 2½ - ✘ - - 39021943 2.9
Consisting of: flange, 4 hexagon head bolts with
nuts and discs, and 1 sealing element
P28 Hand pump, wall mounting, grey cast iron, suction-side connection Rp 1½ ✘ ✘ ✘ ✘ 00520485 12
Amarex N 45
Waste Water
Submersible Motor Pump
Electrical accessories
E17 Bubbler control, with master switch, 400 x 300 x 155 mm 2,5 4,0 BS1 400 DLNO 040 02 25) 25)
46 Amarex N
Waste Water
Submersible Motor Pump
E17 Bubbler control, with master switch, 400 x 300 x 155 mm 2,5 4,0 BS2 400 DLNO 040 02 25) 25)
Amarex N 47
Waste Water
Submersible Motor Pump
E65 Open pressure bell set - pneumatic and bubbler control Tube length 10 m 19071721 1.2
with polyamide tube 8 x 1 mm Tube length 20 m 19071837 2
Tube length 50 m 19074200 2.5
E66 Closed pressure bell set - pneumatic Tube length 10 m 19071722 3.5
with polyamide tube 8 x 3 mm Tube length > 10 m
E90 Rechargeable battery retrofit kit for LevelControl Basic 2, for For type BC, consisting of 19074194 0.8
powering the electronics, the float switches or internal pressure 2 rechargeable batteries
sensor and the alarm equipment (buzzer, horn, alarm 6 V, 1.3 Ah and charging
combination), for single-pump and dual-pump stations unit
48 Amarex N
Waste Water
Submersible Motor Pump
Control units for Amarex N with ATEX For ATEX-compliant variants, intrinsic safety barriers and
an ATEX level switch (float switch) must be fitted. Selection via
The control units are not explosion-proof, which means KSB EasySelect.
that they must not be operated in potentially explosive
atmospheres.
E21 Pneumatic, with master switch, 400 x 278 x 120 mm 2,5 4,0 BC1 400 DPEO 040 02 26) 26)
E23 Bubbler control, with master switch, 400 x 300 x 155 mm 2,5 4,0 BS1 400 DLEO 040 02 26) 26)
Amarex N 49
Waste Water
Submersible Motor Pump
41 Pneumatic, with master switch, 400 x 278 x 120 mm 2,5 4,0 BC2 400 DPEO 040 02 26) 26)
E43 Bubbler control, with master switch, 400 x 300 x 155 mm 2,5 4,0 BS2 400 DLEO 040 02 26) 26)
50 Amarex N
Waste Water
Submersible Motor Pump
E66 Closed pressure bell set - pneumatic Tube length 10 m 19071722 3.5
with polyamide tube 8 x 3 mm Tube length > 10 m
E70 Horn, 12 V DC, 105 dB(A), 1.2 W, not explosion-proof 01086547 0.1
E90 Rechargeable battery retrofit kit for LevelControl Basic 2, for For type BC, consisting 19074194 0.8
powering the electronics, the float switches or internal pressure of 2 rechargeable
sensor and the alarm equipment (buzzer, horn, alarm batteries 6 V, 1.3 Ah
combination), for single-pump and dual-pump stations and charging unit
Amarex N 51
30.05.2013
2563.5/13-EN
KSB S.A.S.
128, rue Carnot • 59320 Sequedin/Lille (France)
B.P. 60095 • 59482 Haubourdin Cedex (France)
Tel. +33 3 2022-7000 • Fax +33 3 2022-7099
www.ksb.com