Protek Catalog 2014

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 58

www.gsinstrument.

com
CONTENTS
Analyzer
06 Protek A338_4Ports 8GHz Vector Network Analyzer
08 Protek A338 8GHz Vector Network Analyzer
10 Protek A333 3.2GHz Vector Network Analyzer
12 Protek A434L 4GHz Cable & Antenna Analyzer
14 Protek A734 4.4GHz Handheld Spectrum Analyzer
16 Protek 7830+G632 2.9GHz Handheld Spectrum Analyzer
18 Protek 3201/3290N 2.0GHz/2.9GHz RF Field Strength Analyzer

Oscilloscope
22 Protek 5000 Series Digital Storage Oscilloscope
24 Protek 6500 Series Analog Oscilloscope
25 Protek 6502S Analog Oscilloscope with Multimeter Function
26 Protek 2090/2150/2250 PC Based DSO
27 Protek 1000 Series Handheld Scope-meter

Generator
30 Protek 9301/9302 Arbitrary & Function Generator
32 Protek 9300 Series Digital Synthesis Arbitrary Function Generator
36 Protek GD-0000N Series DDS Function Generator
37 Protek 9205A/9205C Sweep Function Generator

Meter
40 Protek D705T Digital Multimeter
42 Protek 506 Digital Multimeter
44 Protek 608 Digital Multimeter
46 Protek M733 RF Power Meter
48 Protek 9216A LCR Meter
50 Protek 4000 Bench Type Multimeter
52 Protek 305/307 Clamp Meter

Power Supply
54 Protek 3003/3005 SDT Series Power Supply
TEST
TEST & &
MEASURING
MEASURING
INSTRUMENTS
INSTRUMENTS History
2005
- World First Mobile WiMAX 60W AMP development
- TL9000 / ISO9001 Certification

1988
- IPO (Initial Public Offering) to
KOSPI (Korean Stock Market)

1972 1997 2006


- Company established. - Subsidiary Factory foundation - 2.9GHz Handheld
in Qingdao, China Spectrum Analyzer
Development / Production

1989 1998 2001


Signed contract with Netherlands- Developed voice over FLEX System. Completed development of LPA
based Phillips for Oscilloscope OEM. Developed GSM LPA and Digital for CDMA 1X Base Station
Developed Digital Storage Oscilloscope. Satellite Receiver.
Developed and started producing 2003
1986 CDMA Fiber Optic Repeater.
Developed and started producing LPA
Signed contract with Japanese AARON
for developing and producing
1997 for CDMA 1X Base Station.

Oscilloscope. Established China subsidiary factory.


02
03
2013
- A434L Cable and Antenna Analyzer Development
- A734 Handheld Spectrum Analyzer Development

2008
- 3.2GHz Vector Network Analyzer
Development / Production
2011
- 8GHz Vector Network Analyzer
Development/ Production

2007 2010 2012


Completed development of Tracking Recieved a certification of MiBOS(LTE Fiber Optic), SmartCell,
Generator G632 for Protek 7830. Excellent Quality Product by Trio-M, Trio-MM, Trio-L(LTE RF
Korean Public Procurement Service Repeater) Development.
2006 (PPS) (Protek A333)
2011
Developed Handheld Spectrum
Analyzer Protek 7830.
2009
8GHz Vector Network Analyzer
Completed development WiMAX 5W Obtained a certification of NEP
A338 Development / Production
AMP for ZTE. (New Excellent Product) by Korea
Developed DUO-LIF PAM Agency for Technology and Standards.
(Protek A333)
2005
Developed WiBro 60W AMP first
2008
in the world. Won Ministry of Knowledge Economy
Completed development AMP SF-C20, Korea Technology Award. (Protek A333)
C60, W20 for SKT repeater. Presented with Good Design Award.
Developed Nortel WiBro 35W AMP Completed development WiMAX
for ZTE. Femtocell, Small BTS, 4G technology
Completed development WCDMA 10W for wireless telecommunication.
AMP for ZTE. (Protek A333)
Vector

Vector

Vector

4GHz Cable & Antenna Analyzer

4.4GHz

2.9GHz

2.0GHz/2.9GHz
Protek A338 Vector Network Analyzer 4 port version is not only fully inherited from
great features such as fast sweep time, frequency offset, and time domain of
Protek A333/A338 series but specialized in pursuing higher efficiency in the production
lines of passive components and R&D laboratories by adding more ports.
With a great demand on the smartphone production in the fast changing environments,
Protek A338 4port version provides best and affordable solutions for vendors.
Frequency Range : 100kHz ~ 8GHz, 16 Parameters support (S11 ~ S44)
Measurement time per point : 100us per point
Wide Output Power Range : -60dBm to +10dBm
Dynamic Range : >150dB (1Hz IF bandwidth)
Time domain and gating conversion included
Two Independent Signal Sources
Frequency offset mode, including vector mixer calibration measurements
Up to 16 logical channels with 16 traces each
Multiple precision calibration methods and automatic calibration
Up to 500,001 measurement points
Fixture simulation
COM/DCOM compatible for LabView and automation programming

100 kHz to 8.0 GHz

Test Port Output Match (without system error correction) 18 dB

Power Range 100 kHz to 6.0 GHz -60 dBm to +10 dBm

6.0 GHz to 8.0 GHz -60 dBm to +5 dBm

Power Accuracy ±1.5 dB

Power Resolution 0.05 dB

Harmonics Distortion From 300 kHz to 8.0 GHz: -25 dBc

Non-harmonic Spurious From 300 kHz to 8.0 GHz: -30 dBc

Trace Noise Magnitude From 100 kHz to 300 kHz: 5 mdB rms
(IF Bandwidth 3 KHz)
From 300 kHz to 8.0 GHz: 1 mdB rms

Uncorrected Directivity From 100 kHz to 300 kHz: 15 dB


(Without system error correction)
From 300 kHz to 8.0 GHz: 18 dB

18 dB

8 18 dB

9 100 to 240 VAC 50/60Hz

10 130 W

11 320 x 439 x 280 mm

12 11.7 kg
are Succeded by
10.25 kg
238 mm
4GHz
Cable & Antenna Analyzer
+25
4.4GHz
250

Att

Ref. level
Ref. level
Ref. level
Att

marker-center frequency

Ohm

1.6 kg
Ohm
2.9GHz
2.0GHz/2.9GHz
TEST
TEST & &
MEASURING
MEASURING
INSTRUMENTS
INSTRUMENTS Oscilloscope
Digital Storage Oscilloscope

Analog Oscilloscope

Analog Oscilloscope with Multimeter Function

6502S

PC Based DSO

2090/2150/2250

Handheld Scope Meter


Oscillo-
Scope Digital
Storage Oscilloscope
TEST &
MEASURING
INSTRUMENTS

The digital storage oscilloscopes of Protek 5000 series are six models; 5020, 5071, 5100,
5200, 5202 and 5302 which operates at 25, 70, 100, 200 and 300MHz bandwidth with
different real-time sampling rate respectively. Auto measurement, FFT split screen
functions, and useful PC interfaces with 7 inch clear LCD display provide a variety of
convenient options with great value to users in every application.
22
23
Features

Bandwidth (25MHz ~ 300MHz / 2 channels)


Real-Time Sampling Rate (500MSa/s and 1GSa/s)
Equivalent-Time Sampling Rate (25GSa/s)
7 inch TFT Color LCD Display
Record Length up to 1M
Dual Window Mode(Full Screen)
USB Interface

Protek 5020 Protek 5100 Protek 5200 Protek 5071 Protek 5202 Protek 5302

1 Specifi- Bandwidth 25 MHz 100 MHz 200 MHz 70 MHz 200 MHz 300 MHz
Specification cations
Channels 2CH+1EXT

Real-Time Sampling Rate 500MSa/s(single channel), 1G Sa/s, 2G Sa/s(single channel),


250M Sa/s(double channel) 500M Sa/s 1G Sa/s(double channel)
(single/double chnnel)
Equivalent-Time Sampling Rate 10G Sa/s 50G Sa/s 50G Sa/s 50G Sa/s 50G Sa/s 50G Sa/s

2 Horizontal Range 2.5ns/div-50s/div 2.5ns/div-50s/div 2.5ns/div-50s/div 5ns/div-50s/div 2.5ns/div-50s/div 1.0ns/div-50s/div

Scan 100ms-50s/div

Step 1-2.5-5 Order

Mode Main,window Zoom,Scan,X-Y

Bandwidth Limit 20MHz(-3dB)(Except Protek5020)

3 Vertical Rise Time <14ns <3.5ns <1.8ns <5.8 ns <1.7ns <1.2ns

Maximum Input ±400V (DC+AC Pk-Pk)CATⅠ CATⅡ

Input Impedance 1MΩΙl17pF 1MΩΙl3pF,50Ω

Polarity NORMAL/INVERT

Probe 1X/5X/10X/50X/100X/500X/1000X 1X/10X/100X/1000X

4 Trigger Source CH1,CH2,EXT,EXT/5,AC Line

Trigger Sensitivity ±(0.2divxV/div)(within±4divisions from center of screen)EXT:±(6% of setting+40mv)EXT/5:±(6% of setting+200mv)


Mode Auto, Normal, Single

Type Edge,Pulse,Video,Slope,Alternative

5 Other Voltage Measurement VPP,Vmax,Vmin,Vamp,Vtop,Vbase,Vavg,Mean,Vrms,Crms,FOV,FPRE,ROV,RPRE

Time Measurement Period,Freq,+Wid,-Wid,Rise time,Fall time, BWid,+Dut,-Dut

Cursors Measurement Manual mode,Track mode,Auto mode

Waveform Signal Process CH1+/-CH2, CH1*CH2, CH1/CH2, FFT

Interface Classical,Modern,Traditional,Succinct

Display 7 inches(178mm) color TFT(480*234)LCD

Display Resolution 480 horizontal by 234 vertical pixels

Power Source AC 100-240V, 45Hz-440Hz,50VA Max

Dimension / Weight 323.1 x 135.1 x 157 mm(L*W*H) 2.5kg 358 x 156 x 118 mm(L*W*H) 4.3Kg

Memory Depth 32Kpts(single channel), 16Kpts(double channel) 40Kpt,20Kpts 24Kpts(single chnnel),


(single/double 12Kpts(double channel)
channel)

Vertical Senstivity 2mv-10v/div(1-2-5 order) 2mv-5v/div(1-2-5 order)

Vertical Resolution 8bit

Coupling AC,DC,LF rej,HF rej

Range CH1,CH2:±6divisions from center of screen EXT:±1.2V EXT/5:±6V

Math Operation +,-,*,/,FFT

Digital Filter High-Pass,Low-Pass,Band-Pass,Band-Stop

Internal Storage 2groups of reference waveform, 2groups of reference waveforms,


20 groups of settings,20 groups of waveforms 20 groups of settings,20 groups
of waveforms

External Storage Bitmap save, CSV save, Waveform save,Setting save

Lasting off, 1s, 2s, 5s,infinite

Language English,French,German,Russian,Spanish,Chinese,Traditional Chinese,Portuguese,


Japanese,Korean,Italian,Arabic
Analog Oscilloscope

Features

2 Channels 4 Traces
X-Y Operation
12KV CRT(6504, 6506, 6510) / 1.9KV CRT(6502)
X10 Magnifier(6504, 6506, 6510) / X5 Magnifier(6502)

Protek 6502 Protek 6504

Specification 1 Vertical Direction

Operation Mode CH A, CH B, DUAL, ADD

Sensitivity 5mV ~ 5V /div, 1mV ~ 1V/div (X5 MAG)

Bandwidth (AC/DC) 20MHz 40MHz

Input Impedance 1MΩ ±2%, 25pF ±3pF

Rise Time 17.5ns 8.7ns

Max. Input Voltage 300V (DC±AC peak)

2 Horizontal Deflection

Sweep Mode A, XY, ALT, MAG, X5 MAG A, XY, ALT, MAG, X10 MAG

Sweep Time 0.1 µs to 0.2s/div ±3%

Trigger Source INT, CHB, LINE, EXT

Trigger Coupling AC Coupling

Tirgger Sensitivity Frequency / INT / EXT Frequency / INT / EXT

Normal DC ~ 2MHz / 3div / 200mV DC ~ 5MHz / 3div / 200mV

2MHz ~ 20MHz / 3div / 300mV 5MHz ~ 40MHz / 3div / 800mV

Auto 20Hz ~2MHz / 3div / 200mV 20Hz ~ 5MHz / 3div / 200mV

2MHz ~20MHz / 3div / 300mV 5MHz ~ 40MHz / 3div / 800mV

Tv Sync Min 1 div / Min 1 1 Vp-p

3 X-Y Operation

Frequency Bandwidth DC ~ 500kHz

Phase Difference Less Than 3° (DC ~ 50kHz)

4 General

CRT 6 inch (8 X 10div), 1.9KV 6 inch (8 X 10div), 12KV

Power Requirement AC 100V / 120V / 220V / 230V ± 10%


24

Dimension 335(W) X 140(H) X 375(D) mm

Weight Approx. 7.3kg


25
Analog Oscilloscope with Multimeter Function

Features

20MHz Bandwidth

Built-in DMM(Digital Multimeter)

Dual Component Display

Best for Developing And Repairing Electronics

1 Vertical Mode CHA, CHB, ALT, CHOP, ADD


Specification Deflection
Sensitivity 5mV/Div to 5V/Div

Bandwidth DC : 20MHz / AC : 10Hz ~ 20MHz

Input Impedance 1MΩ ±2%, 25pF ±3pF

Rise Time 17.5ns

MAX. Input Voltage 400V(DC±AC Peak)

2 Horizontal Mode A, XY, ALT, MAG, X 5MAG


Deflection
Trigger Source INT, CHB, LINE, EXT

Trigger Coupling AC Coupling

Trigger Sensitivity Frequency : DC ~ 20MHz / INT : 3Div / EXT : 200 ~ 300mV

X-Y Sensitivity 5mV/Div to 5V/Div

Bandwidth DC : 500kHz

Phase Difference <3° (DC ~ 50kHz)

3 Component Mode COMP1 OR ALT(COMP1 & COMP2 : Dual Component)


Test
Terminal Voltage AC 9 Vrms without Load

Short Current Approx. 2mA

MAX. Input Voltage 8V(DC±AC peak)

4 Digital Multimeter Mode DC/ACV, DC/AC µa, DC/AC mA, DC/AC A, Ω, Diode, Hz, Capacitance, Temp

Display 4000count

5 Digital Multimeter CRT 6 inch (8 X 10div), 1.9KV


PC Based DSO

Features

Real-Time Sampling Rate (100MS/s, 150MS/s, 250MS/s)


Bandwidth (40MHz, 60MHz, 100MHz / 2 Channels)
USB Interface
Data Management Support (Microsoft Excel)

DSO-2090 DSO-2150 DSO-2250

Specification 1 Real-time Sampling 100 MS/s 150 MS/s 250 MS/s

2 Bandwidth 40 MHz(-3dB) 60 MHz(-3dB) 100 MHz(-3dB)

3 Single Shot Bandwidth 40 MHz 60 MHz 100 MHz

4 Buffer Size 10k ~ 64k Samples 10k to 512k Samples

5 Channels 2 Channels

6 Voltage Range 10mV to 5Vdiv@ x1 Probe

100mV to 50Vdiv@ x10 Probe

1V to 500Vdiv@ x100 Probe

10V to 5kVdiv@ x1000 Probe

7 DC Accuracy ±3%

8 Timebase Range 4ns/div to 1h/div (1-2-4 Sequence)

9 Offset Level ±4 Divisions

10 Coupling AC, DC, GND AC, DC, GND

11 Impedance 1M ohm

12 Input Protection 35Vpk(DC+Peak AC <10kHz, Without External Attenuation)

13 Roll Mode 1 s/div to 1 h/div

14 Range 8 Divisions 10 Divisions 8 Divisions

15 Pre/Post Trigger 0% to 100%

16 Trigger Type Edge Trigger: Rising Edge, Falling Edge

17 Trigger Mode Auto, Nomal and Single

18 Autoset Yes

19 Settabillity 0.03 div Increments

20 Trigger Level ±4 Divisions

21 Measurements Vp-p, Vmax, Vmin, Vmean, Vrms, Vamp, Vhigh, Vlow, Positive Overshoot, Negative Overshoot, Cycle Mean, Cycle rms, Period,
Frequency, Positive Pulse Width, Negative Pulse Width, Rise Time(10% to 90%), Fall Time(10% to 90%), Positive Duty Cycle,
Negative Duty Cycle
22 Cursor Time/ Frequency Difference, Voltage Difference Frequency Only in FFT Mode

23 Math Addition, Subtraction, Multiplication, Division

24 FFT Rectangular, Hanning, Harmming, Blackman Window

25 Interface USB

26 Power No external Power Source required

Bus-Powered From USB 1.7(W)

27 Calibration Signal Output 2V, 1 kHz, Square Wave

28 Trace Display Point/Line

29 Vertical Position Variable Yes

30 Grid On/Off

31 File Management Image Save : BMP, JPG


26

Data Save : DSO

OLE(Object Linking and Embedding) Automation : Data Generation For Microsoft Excel
27

Setting Save/Load

32 Print Print in Color/Mono


Handheld Scope-meter

Features

Bandwidth (60MHz, 200MHz / 2 Channels)

Real-Time Sampling Rate (150MSa/s , 500MSa/s)

6,000 Counts DMM Resolution (AC/DC 600V, 10A)

5.7 inch TFT Color LCD Display (Backlight)

6 hours Operation Time (Battery)

USB Host / Device 2.0 Full-speed Interface

Protek 1006 Protek 1020

1 Vertical Channel 2
Specification
Bandwidth 60 MHz 200 MHz

Rise Time 5.8 ns 1.7 ns

Input Impedance Resistance : 1 M; Capacitance : 15 pF

Input Sensitivity 10 mV/div to 5V/div 2 mV/div to 10V/div

Input Coupling AC, DC With Ground Level Indicator

Vertical Resolution 8 Bits

Memory Depth 32K At Signal Channel, 16K At Dual Channel

Maximum Input 300 V(DC+AC Peak)

2 Horizontal Sampling 150Msa/s 500Msa/s

Equivalent Max. Sampling Rate is 50Gsa/s For All Items

Time Base Range 5ns/div ~ 1000s/div 2ns/div ~ 1000s/div

Time Base Precision ±50 ppm


3 Trigger Source CH1, CH2

Mode Edge, Pulse Width, Alternative Edge, Video, Pulse Width, Alternative

4 X-Y Mode X-Axis Input Channel 1

Y-Axis Input Channel 2

Phase Shift Max.3 Degree

5 Cursors and Voltage Measurement Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot
Measurement
Time Measurement Frequency, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle

Delay Measurement Delay 1-> 2 , Delay 1-> 2

Cursors Measurement Manual, Track, Auto Measure Modes

Waveform Signal Process CH 1+/- CH2, CH1 x CH2, CH1/CH2, FFT, Invert

Storage 15 Waveforms and Setups

6 Meter Mode Maximum Resolution 6,000 Counts

DMM Testing Modes Votage, Currnet, Resistance, Capacitance, Diode & Continuity

Maximum Input Voltage AC: 600V, DC: 600V

Maximum Input Current AC: 10A, DC: 10A

Input Inpendance 10 M©

7 Display TFT LCD Type 5.7 Inch LED Backlight Display

Display Resolution 240 x 320 Dots

8 Interface USB USB Host/Device 2.0 Full Speed Supported

Optical RS232, LAN

9 Power Source Line Voltage Range AC 100V ~ 240V, 50 Hz ~ 60 Hz; DC Input : 8.5 VDC, 1500 mA

Battery Power (Installed) 6 Hours (Li-on Battery)

10 Mechanics Dimension 245 x 163 x 52 (mm)

Weight 1.2 kg
TEST &
MEASURING
INSTRUMENTS Generator
Arbitrary & Function Generator

9301/9302

Digital Synthesis Arbitrary Function Generator

DDS Function Generator

Sweep Function Generator

9205A/9205C
Features

DDS(Direct Digital Synthesizer) Technology


Function : Sine, Squre, Triangle, Ramp, Noise
and Arbitrary Waveform
Frequency Range : 0.00000001 Hz to 31 MHz
Frequency Resolution : 0.00000001 Hz
Frequency Accuracy : ±3 PPM
Modulation : AM, FM, PM, Burst
Arbitrary Waveform of 40M Sample/sec, up to 16K Sample Point
RS232 Interface (Standard)
GPIB Interface (Standard)
Arbitrary Waveform Composer (Standard)

Generator
Arbitrary &
Function Generator
TEST &
MEASURING
INSTRUMENTS

Main Function BNC(CH1/Ch2 output) Function Keys

Sine, Square, Triangle, Ramp, Noise, Arbitary Sine, Square, Triangle, Ramp, Noise, Arbitary

Step Keys Sweep / Modulate Keys

Sine, Square, Triangle, Ramp, Noise, Arbitary Sine, Square, Triangle, Ramp, Noise, Arbitary
30
31
Protek 9302
Arbitrary & Function Generator 31MHz
Arbitrary Generator Outputs
Waveforms From 2CH (Protek 9302)
Adopted In Various Fields

ARB Waveform Composer


Composing Arbitrary Waveform
Composing Standard Waveform
Audio Equipment Communicating Testing Electronic
Equipment Equipment

Protek 9301/9302 Various Waveforms


Sweep AM FM Burst Sine Square Triangle Ramp Arbitrary

Waveform Specifications Reception Frequency Signal Characteristics Specifications


Specifications Standard Function Sine, Square, Triangle, Ramp, Noise, Arbitrary Rise/Fall Time <16ns(10% to 90%)

Wave
Square
AWC Software Windows 95, 98, 2000, NT, ME Asymmetry <1% of Period +4 ns
AWC Function Sine, Square, Triangle, Ramp, DC, Noise, Overshoot <5%
Damped Sine, Exponential Rise, Exponential Fail,
Rise/Fall Time 35 ns

Wave
Arbitrary
Free Hand, Line
Waveform Length 16 to 16, 383 Points Linearity 0.5% of Full Scale Output
Amplitude Resolution 12 bits Modulation Characteristics Specifications
Sampling Rate 40 M Samples/sec Source Internal(Sine, Square, Triangle, Ramp or Arbitrary) or External
Modulation
Amplitude

Frequency Characteristics Specifications Depth 0 to 100% AM or ±100%DSBSC


Sine, Square 0.01 µHz to 31 MHz Rate 0.001 Hz to 10kHz Internal, 20kHZ Max External
Ramp, Triangle 0.01 µHz to 2 MHz Distortion <-35dB at 1 kHz, 80% Depth
Noise 10 MHz (64Bits M Type) DSB Carrier <-35dB Typical at 1 kHz Modulation Rate(DSBSC)
Output Characteristics Specifications External Input ±5V For 100% Modulation, 100KΩ Impedance
Output Protek 9301(1Channel), Protek 9302(2Channel) Source Internal (Sine,Square,Triangle,Ramp or Arbitrary)
Modulation Modulation Modulation
Frequency Phase

Source Impedance 50Ω Floating Rate 0.001 Hz to 10 kHz


Output Units Vpp, Vrms, dBm, % Span 0.01µHz to 31MHz(2MHz For Triangle, Ramp)
Sync Output Front-Panel TTL Output For Each Channel Source Internal (Sine,Square,Triangle,Ramp or Arbitrary)
Inter Channel Crosstalk <0.05% (Protek 9302 Only) Rate 0.001 Hz to 10 kHz
DC Offset Span ±9999.99°
Range ±5V (Limited Such That | Vac Peak |+| Vdc | <5V) Waveform Sine,Square,Triangle,Ramp or Arbitrary
Burst

Accuracy ±1.5% of Setting +0.5mV (DC Only) Frequency 2 MHz to Sine, Square, Triangle, Ramp
Amplitude Range ±80 mV Depending On AC And DC Settings Count 1 to 65,000 Cycles/Burst
0.05Vp-p to 10Vp-p Into 50Ω
Phase Shift ≤100 kHz
1. Sine Wave Amplitude Accuracy ( 0 V DC Offset) Type Linear or Log
Sweep
Frequency

Time 0.001 Hz to 10 kHz


0.01µHz 100kHz 20MHz 25MHz
~100KHz ~20MHz ~25MHz ~31MHz Span 0.01µHz to 31 MHz (2MHz For Triangle, Ramp)
5-10Vpp ±0.2dB ±0.3dB ±0.6dB ±0.9dB Marker Output Two Markers May Be Set At Any Sweep Point(TTL Output)
0.05-5Vpp ±0.4dB ±0.4dB ±0.8dB ±0.8dB Sweep Output 0-10 V Linear Ramp Signal, Synchronized to Sweep
2. Square Wave Amplitude Accuracy Source CH1 : INT Rate, Single, POS EXT1, NEG EXT1, Line
Triggering

0.01µHz 100KHz 20MHz CH2 : INT Ch1, INT Rate, POS EXT2, NEG EXT2
~100KHz ~20MHz ~31MHz Rate 0.0001s ~ 999.99s
5-10Vpp ±3% ±6% ±15% External Input ±Edge, TTL Input
0.05-5Vpp ±5% ±8% ±16% Output TTL Output
3. Triangle, Ramp, Arbitary Amplitude Accuracy Accuracy ±3 ppm(20°C to 30°C)
0.01µHz~100KHz 100KHz~2MHz Aging ±3 ppm/Year
5-10Vpp ±4% ±8% Input 10MHz/N ±2ppm, N=1 to 8, 1Vp-p Minimum Input Level
0.05-5Vpp ±5% ±9% Output 10MHz, >1 Vp-p Sine Into 50Ω
Sine Wave Spectral Purity Specifications Operating Temperature 5°C to 40°C
Spurious Components DC to 2MHz : <-65dBc(Non-Harmonic) Operating Humidity 35% to 80%
2MHz to 31MHz : <-65dBc+6dBc/Octave(Non-Harmonic) Weight Protek 9301 : 8.2 kg, Protek 9302 : 8.7 kg
Subharmonic <-50dBc (Sine, 5Vpp) Dimensions 363mm(W) x 109mm(H) x 386mm(D)
Harmonic Distortion : Harmonically Related Signals Will Be Less Than Interfaces RS-232 (2400 to 19,200 bps) and GPIB (Optional)
DC to 1 MHz (Sine, 1Vpp) : <-45dBc Power Supply 100/ 120/ 220/ 230 VAC(±10%) 50/ 60 Hz
1 MHz to 31 MHz (Sine, 1Vpp) : <-32dBc Power Consumption Protek 9301 : 46W, Protek 9302 : 80W
Features

DDS(Direct Digital Synthesis) Technology


Main Waveform Frequency Range (1Hz ~ 120MHz)
Amplitude Range (1mV ~ 10Vp-p(50Ω))
Over 30 Kinds of Output Waveforms Support (Including Arbitrary Waveform)
Signal Save and Recall (10 Channels)
Frequency Counter Measurement Range (1Hz ~ 100MHz)
Built-in RS232C
GPIB(Option)

Generator
Digital Synthesis Arbitrary
Function Generator
TEST &
MEASURING
INSTRUMENTS

The Protek 9300 series are six digital synthesis arbitrary function generators based on
DDS (Direct Digital Synthesis); 9305, 9310, 9320, 9340, 9380, 93120, which can output
not only basic waveforms but arbitrary waveforms and modulated waveforms with
high resolution such as AM, FM, FSK, PSK, sweep, burst. Protek 9300 series are widely
used by electronic engineers in laboratories, production lines, education industries.

Frequency Measurement
Specification 1 Frequency Range 1Hz ~ 100MHz
(Counter) 2 Min. Input ATT Opened 50mV (Freq 10Hz ~ 50MHz), 100mV (Freq 1Hz ~ 100MHz)
Voltage
ATT Closed 0.5V (Freq 10Hz ~ 50MHz), 1V (Freq 1Hz ~ 100MHz)
32

3 Max. Input Voltage 100Vpp (Freq≤100KHz), 20Vpp (1Hz ~ 100MHz)

4 Low Pass Cut Off Frequency About 100kHz


Filter
With Internal Attenuation ≤-3dB
33

With External Attenuation ≥-30dB (Freq>1MHz)

5 Gate Time 10 ms ~ 10s


Operation Characteristics
Specification 1 Power 220V ±10%, 50 ~ 60Hz, Max. 35W
2 Temperature / Humidity 0°C ~ 40°C, 35% ~ 80%
3 Dimension 255 mm x 370 mm x 100 mm
Subject 9305 9310 9320 9340 9380 93120
Function 1 Waveform Frequency Main Waveform 1µHz to 5MHz 1µHz to 10MHz 1µHz to 20MHz 1µHz to 40MHz 1µHz to 80MHz 1µHz to 120MHz
Generation Range
Stored Waveform 1 µHz ~ 100 kHz
Resolution 1 µHz
Accuracy ±5x0.000001
Stability ±1x0.000001
2 Frequency Main Waveform Sine, Square, TTL
Level Resolution 12 Bits
Sampling Rate 200Msa/s
Sine Waveform Distortion Harmonic -50dBc(Freq≤5MHz), -45dBc(Freq≤10MHz), -40dBc (Freq≤20MHz), -35dBc(Freq≤40MHz)
Sine Waveform Distortion 0.1%(20MHz ~ 100kHz)
Square Waveform Rising/Falling Time Less Than 25ns Less Than 15ns
Stored Waveforms 27 Waveforms(Sine, Square, Triangle, Up-Lamp, Noise, Pulse, P-Pulse, N-Pulse, P-dc, Stair, C-Pulse, Commut-fu, Commut-hr,
Waveform Sine-tra, Sine-ver, Sine-pm, Log, Exp, Round-har, Sin%, Squ-root, Tangent, Cardio, Quake,Combination

Waveform Length 4096 Dots


Amplitude Resolution 10 Bits
Duty Factor Of Pulse Wave 0.1% ~ 99.9% (Less Than 10kHz), 1% ~ 99% (10kHz ~ 100kHz)
3 Amplitude Amplitude Range 2mV ~ 20Vp-p(High Impedance), 1mV ~ 10Vp-p(50Ω)
Max. Resolution 2µVp-p(High Impedance), 1µVp-p(50Ω)
Amplitude Accuracy(at 1KHz) ±(1%+0.2mV)
Amplitude Stability ±0.5% / 3Hours
Flatness Amplitude ≤ 2V ±3% (Freq≤5MHz), ±10% (5MHz< Freq≤40MHz)
Amplitude > 2V ±5% (Freq≤5MHz), ±10% (5MHz< Freq≤20MHz), ±20% (20MHz< Freq≤40MHz)
Output Impedance 50Ω
4 Offset Offset Range ±10V (High Impedance Freq ≤40MHz), ±2V(High Impedence Freq ≥40MHz)
Resolution 2µV(High Impedance), 1µV(50Ω)
Error ±5% + 10mV / ±5% + 20mV
5 AM Carrier Waveform Sine, Square
Modulation Mode INT, EXT
Modulation Waveform Sine, Square, Triangle, Up-Lamp, Down-Lamp
Signal
Frequency 10MHz ~ 20kHz
Relative Modulation Error ±(5%+0.2)(100µHz < Freq≤10kHz), ±(10%+0.5)(10kHz < Freq≤20kHz)
Modulation Depth 1% ~ 120%
Amplitude External Input Signal 3Vpp(-1.5V ~ +1.5V )
6 FM Carrier Waveform Sine, Square
Modulation Mode INT, EXT
Modulation Waveform Sine, Square, Triangle, Up-Lamp, Down-Lamp
Signal
Frequency 100µHz ~ 10kHz
Peak Frequency Deviation Max. 50% Of Carrier Frequency For Internal FM; Max. 10% Of Carrier Frequency For External FM; Input Signal Voltage 3Vp-p(+1.5V ~ -1.5V)
FSK Input Signal Either Frequency 1 or Frequency 2
Modulation
Control Mode INT, EXT (TTL Level, Low Level F1, High Level F2)
Alternation Rate 0.1 ms ~ 800s
7 PM Waveform Sine, Square
PSK PSK Phase 1(P1), Phase 2(p2)
Modulation
Range 0.1° ~ 360.0°
Resolution 0.1°
Alternation Time Interval 0.1 ms ~ 800s
Control Mode INT, EXT (TTL Level, Low Level F1, High Level F2)
8 Burst Waveform Sine, Square
Burst Counting 1 ~ 10000 Period
Alternation Time Interval 0.1 ms ~ 800s
Control Mode INT, EXT
9 Sweep Waveform Sine, Square
Time 1 ms ~ 800s(Linear), 100ms ~ 800s(Log)
Mode Linear, Log
External Trigger Signal Frequency DC ~ 1kHz(Linear), DC ~ 10kHz(Log)
Control Mode INT, EXT
10 Output of Waveform Sine, Square, Triangle, Up-Lamp, Down-Lamp
Modulation
Frequency 100µHz ~ 20kHz
Signal
Amplitude 5Vpp±2%
Output Impedance 620Ω
11 Storage Storage Parameter Single Frequency, Amplitude, Waveform, DC Offset Values and Function State
Storage Capacity 10 Signal
Output Display Variable Knob

Power On/Off S/W Output Terminal


Waveforms Selective S/W Output Value Manual Input S/W
(Sine, Square, Triangle, Ramp, Pulse)
Output On/Off S/W
Modulation Signal Selective S/W
(AM, FM, FSK, PSK, Sweep, Burst)

Output Waveform 1 (Sine) Output Waveform 2 (Square)


Various
Waveforms

>> Sine Wave: 2V, 10kHz >> Square Wave: 2V, 10kHz
1 Set the sine wave output of 9300 1 Set the sine wave output of 9300
Power Voltage : Min 1mV ~ Max 20V Power Voltage : Min 1mV ~ Max 20V
Frequency : Min 100µHz ~ Max 120MHz Frequency : Min 100µHz ~ Max 120MHz
2 Input the signal on DSO and Process the 2 Input the signal on DSO and Process the
auto key a time auto key a time
3 Check the output signal of 9300 3 Check the output signal of 9300

Output Waveform 3 (Triangle) Output Waveform 4 (Ramp)

>> Triangle Wave: 2V, 10kHz >> Ramp Wave: 2V, 10kHz
1 Set the sine wave output of 9300 1 Set the sine wave output of 9300
Power Voltage : Min 1mV ~ Max 20V Power Voltage : Min 1mV ~ Max 20V
Frequency : Min 100µHz ~ Max 120MHz Frequency : Min 100µHz ~ Max 120MHz
34

2 Input the signal on DSO and Process the 2 Input the signal on DSO and Process the
auto key a time auto key a time
3 Check the output signal of 9300 3 Check the output signal of 9300
35
Output Waveform 5 (Pulse) Output Waveform 6 (Arbitrary)
Various
Waveforms

>> Pulse Wave: 2V, 10kHz >> Arbitrary Wave: 27, Stair
1 Set the sine wave output of 9300 1 Set the arbitrary wave output of 9300
Power Voltage : Min 1mV ~ Max 20V (1 ~ 27)
Frequency : Min 100µHz ~ Max 120MHz 2 Input the signal on DSO and Process the
2 Input the signal on DSO and Process the auto key a time
auto key a time 3 Check the output signal of 9300
3 Check the output signal of 9300

Waveform Modulation 7 (FM) Waveform Modulation 8 (AM)

>> FM Modulation Used By Sine Wave >> AM Modulation Used By Sine Wave
1 Set the sine wave output of 9300 1 Set the sine wave output of 9300
2 Set the FM modulation function 2 Set the AM modulation function
(DEVIR, FREQ, WAVE, SOURCE) (LEVEL, FREQ, WAVE, SOURCE)
3 Check the output signal of 9300 3 Check the output signal of 9300
through DSO display through DSO display

Waveform Modulation 9 (Sweep) Waveform Modulation 10 (Burst)

>> Sweep Modulation Used By Sine Wave >> Burst Modulation Used By Sine Wave
1 Set the sine wave output of 9300 1 Set the sine wave output of 9300
2 Set the Sweep modulation function 2 Set the Burst modulation function
(MODE, START-F, STOP-F, TIME, TRIG) (TRIG, COUNT, SPACE-T, PHASE)
3 Check the output signal of 9300 3 Check the output signal of 9300
through DSO display through DSO display

Waveform Modulation 11 (FSK) Waveform Modulation 12 (PSK)

>> FSK Modulation Used By Sine Wave >> PSK Modulation Used By Sine Wave
1 Set the sine wave output of 9300 1 Set the sine wave output of 9300
2 Set the FSK modulation function 2 Set the PSK modulation function
(START-F, STOP-F, SPACE-T, TRIG) (P1, P2, SPACE-T, TRIG)
3 Check the output signal of 9300 3 Check the output signal of 9300
through DSO display through DSO display
DDS Function Generator

Features

DDS(Direct Digital Synthesis) Technology


Sine Wave Frequency Range (1µHz ~ 20MHz)
9 Waveforms Support
Built-in LCD
Full Digital Control with Keypad and Rotary Knob
RS-232C Interface

Protek GD-0005N Protek GD-0010N Protek GD-0020N

1 Waveform Sine, Triangle, Square, Rising Slope, Declining Slope, Random Noise, SIN(x)/x,
Rising/Drop Exponent, Pulse Waveform
Specification
2 Frequency Sine 1µHz ~ 5MHz 1µHz ~ 10MHz 1µHz ~ 20MHz

Square 1µHz ~ 5MHz 1µHz ~ 10MHz

Other Wave 1µHz ~ 1MHz

Resolution 8 Bits or 0.1µHz

3 Signal Square Rising / Falling Time ≤15 ns (50Ω Load, 1 Vpp)

Square Overshoot ≤5%

Asymmert (1kHz) ≤1% + 20ns

Duty Modulus 0.1% ~ 99.9 (<10kHz) / 1% ~ 99% (10kHz ~ 100kHz) / 3% ~ 97% (<1MHz)

Triangle, Ramp Linearity <0.1%

4 Output Amplitude Setting 1mVpp ~ 20Vpp(Hign Impedance)

0.5mVpp ~ 10Vpp(50Ω)

Deviation Ratio (5Vpp) -100% ~ 100%

Impedance 50Ω

5 Sweep Type Lineaity / Logarithm

Direction Positive / Negative

Early / Final Freq. 1Hz ~ 5MHz 1Hz ~ 10MHz 1Hz ~ 20MHz

6 AM Waveform Modulation Any Inner Function Waveform

Freq. Modulation 100MHz ~ 20kHz

AM Depth 0% ~ 100%

Source Inner / External

7 FM Waveform Modulation Any Inner Function Waveform

Freq. Modulation 100MHz ~ 20kHz

Freq. Offset 1Hz ~ 5MHz 1Hz ~ 10MHz 1Hz ~ 20MHz

Source Inner

8 PM Waveform Modulation Any Inner Function Waveform

Freq. Modulation 100MHz ~ 20kHz

Phase Offset 360 Degree

Source Inner

9 Frequency Range 1 Hz ~ 100 MHz


Counter
Input Signal 100mV
36

10 Mechanics Power AC 220V±10%, 50Hz±5%

Dimension 95 mm(H) x 245 mm(W) x 340 mm(D)

Weight About 2kg


37
Sweep Function Generator

Features

Sine, Triangle, Square, Pulse Waveform


Ramp Waveform, TTL Square Waveform
Sweep Function
VCG Input
AM Modulation (9205A only)
Frequency Counter Function

Protek 9205C Protek 9205A

1 Output Frequency Range 0.02Hz to 2MHz (7Ranges) 0.03Hz to 3MHz (7Ranges)


Specification
Accuracy Over 1Hz± Count ±Time Base Error

Amplitude 1Vp to 20Vp (Open Circuit), 0.5Vp to 5Vp(50Ω)

Attenuation Fixed 20dB ±1dB, 20dB Continuity Variable

Impedance 50Ω ±5%

2 Sine Wave Flatness Better Than ±3dB ~ 2MHz at Max. Output ±3dB ~ 3MHz

Distortion 2% (10Hz ~ 100kHz)

3 Square Wave Rise / Fall Time 100ns or Less

4 Triangle Wave Nonlinearity 1% to 100kHz

Symmetry Variation 1:1 ~ 4:1 1:1 ~ 4:1 (1MHz)/ 1:1 ~ 2.1 (2.5NHz)

VCF Input 0V ~ 10V DC

5 Sweep Function Mode Linear

Width 10:1 ~ 100:1

Time 0.5Hz(2sec) to 50Hz (20msec)

6 Frequency Counter Range 10Hz ~ 2MHz 10Hz ~ 3MHz

Accuracy 0.01%±1Count

Max. Input Voltage 70Vp

Input Impedance 1MΩ

AM Modulation 0 ~ 100%, 400Hz, DC-1MHz


RF Power Meter

LCR Meter

Bench Type

Clamp Meter
40 41
Digital Multimeter
42
43
2

10 Inductance Range 100H

Resolution 0.01H

Accuracy 3% + 5d (UP TO 20H), 5% + 5d (UP TO 50H), 10% + 5d (UP TO 100H)

Open Circuit 3.2V MAX

11 Time Count Range 10 hours

Resolution 1 sec

Accuracy 0.2% + 1d

Display Secondary Display

Alarm Buzzer Sound

12

13

14

15

16

17

18 Dimension 88 x 37 x 199 mm

19 Weight Approx. 410g


RF Power Meter
46
47
LCR Meter

Protek 9216A is a useful tool measuring a device characteristics with various functions.
It has more than 13 orders of magnitude, basic accuracy of 0.05% and 5 test frequencies.

Standard Accessories

Basic accuracy of 0.05% - Radial Fixture


5 Test frequencies - DB25 male connector

Store up to 9 setups in the memory Optional Accessories


Remote over RS -232C
- Kelvin Clips
- SMD Tweezers

Measurement Modes Auto, R+Q, L+Q, C+D, C+R

Equivalent Circuit Serial or Parallel

Parameters Displayed Value, Deviation, % Deviation or Bin Number.


Deviation and % deviation are calculated from a stored relative value.

3 Averaging 2 ~ 10 Measurement

4 Measurement Range R+Q R 0.0001 ~ 2000 Q 0.00001 ~ 50


L+Q L 0.0001µH ~ 99999H Q 0.00001 ~ 50
C+D C 0.0001pF ~ 99999µF D 0.00001 ~ 10
C+R C 0.0001pF ~ 99999µf R 0.00001 ~ 99999K

5 Test Frequency 100Hz, 120Hz, 1KHz, 10KHz, 100KHz

6 Frequency Accuracy ±100ppm

7 Drive Voltage 0.1V, 0.25V, 1Vrms

8 Drive Level Accuracy ±2%

9 Measurement Rate Slow, Medium, Fast: 2, 10 or 20


measurements per second at test frequencies of 1KHz and above and about
0.6, 2.4 or 6 measurements per second at 100Hz and 120Hz.

10 Ranging Auto or Manual


48

11 Triggering Through External Trigger, Continuous, Manual or Remote over RS232 interface

12 Bias Voltage Internal ==> 2.0VDC ±2% External ==> 0 to +40VDC (fused@0.25A)

13 Conditions At least 30 minute warm up, 23°C±5°C


49

14 Basic Accuracy 0.05%


3 4

2 5
1 6

7 11
8 10
9

1 PARAMETER 5 MEAS RATE 7 SETUP


AUTO : This switch causes the most RATE: Selects slow, medium,or fast STO,RCL: These button 3 can store and recall
appropriate parameter to be selected measurement rates(2, 10, or 20 up to 9 setups in the memory.
and measured automatically. Measurements per second at CAL: This button acts as a calibrate mode and
measurment frequency 1kHz or higher). special configrable parameter.
R+Q : lQl<+0.125 BIN#,NOM,LIM: These buttons ar used to
L+Q : Q>+0.125 6 DISPLAY enter binning parameters.
C+Q : Q<-0.125 at Serial mode AVR: User can choose to average from
C+D : Q<-0.125 at parallel mode 2 to 10 measurements with this buttom. 8 TRIGGER
(R+Q = Resistance + Quality Factor HOLD: This button holds the meter in MODE: This button selects between
L+O = Inductance + Quality Factor its current measurement range. continuous(CONT)or triggered(TRIGGERED)
C+D = Capacitance + 1/Q EQU: This botton toggles equivalent measurement.
C+R = Capacitance + Resistance circuit between a series or parallel. TRIG: Under the Trigger mode, when it presses,
DISP: This botton selects the parameter it measures one at a time.
2 FREQUENCY on the display. you can select following
: The output frequency is one of five display types. 9 [0],...[9]
fixed frequencies (100Hz, 120Hz, 1KHz, 10KHz, VALUE: Display the value of the These numeric buttons enter parameters and
100KHz) and is accurate to 100ppm (0.01%) measurment. are only active when the meter is in
DEV: The deviation of the value from the ‘ENTRY’ mode.
3 DRIVE VOLT an entered value.
VOT: The VOLT key cycles through the three %DEV: The percent deviation from 10 ENTER
preset output drive voltage options. the nominal. These three buttons are used when entering
CONS: This botton can set the meter in ENTRY: for entering parameter values. numeric parameters in the entry mode, & acts
the constant voltage mode. BINS: Selects the bin number when as a general purpose ENTER button.
binning is enabled.
4 BIAS 11

This bias mode is used only for capacitance Correcting mistakes when entering numeric
measurements. If you press these buttons data, dan also serves as the ‘LOCAL’ function.
incorrectly, the error message ‘bias for c’ is
displayed.
INT: Internal button selests a 2.0VDC Internal bias
EXT: It can select an external bias mode(0V~40V)
Bench Type Multimeter
50
51
44 45
Clamp Meter
52
53
2

10
11
12
13
14

15
16
17
18
19
20
21
54 55
Specifications and other information shown on this product catalogue are subject to change without notice.

Head Office
GS Instruments Co.,Ltd.
©Copyright GS Instruments Co.,Ltd. All Rights Reserved.

1385-14, Juan-dong, Nam-ku, Incheon


402-200, Korea
Tel +82-32-870-5655
Fax +82-32-870-5640
E-mail isale@gsinstrument.com

China Factory
HCQ Electronics Co.,Ltd.
Danshan Industrial Park, Chengyang District,
Qingdo, Shangdong, China
Tel +86-532-6691-3900
Fax +86-532-6691-0908

www.gsinstrument.com

You might also like