Home > Automation & Protection > Protection & Control > Transformer Protection > T60
Multilin T60
Transformer Protection System
The T60 is designed for various power applications, including
autotransformers, generator step-up transformers, split-phase, angle
regulating transformers and reactors. It uses multiple current and voltage
inputs to provide primary protection and backup protection of transformers,
including differential, ground differential, five distance zones, phase, neutral,
and ground overcurrent, under and overvoltage, under and overfrequency,
over-fluxing, and breaker failure.
Contact Sales
Key Benefits
Buy Now
Secure high-speed protection for transformers, compliant with IEEE C37.91
Interactive Selector Guide
Advanced IEC61850 Ed. 2 certified implementation, complete settings via
Spotlight Application SCL files and IEC 61850-9-2 process bus solution enable resource and platform managing optimization and reduce cost
Transformer Principles & of ownership
Protection
Routable GOOSE (R-GOOSE) enables GOOSE messages going beyond the substation, which enables wide area protection
and control applications
Improved security for transformer energization and inrush provided through a superior adaptive 2nd harmonic restraint
Brochures algorithm
Manuals Three independent fiber or copper Ethernet ports for simultaneous/dedicated network connections with advanced 1
Specifications microsecond time synchronization via LAN with IEEE 1588 support
Software
Sensitive ground fault protection provides low- impedance differential protection down to 5% of the winding to limit
Presentations transformer damage
Support Documents
Phasor Measurement Unit (synchrophasor) according to IEEE C37.118 (2011) and IEC 61850-90-5 support
Product & Cyber Security
Advisories CyberSentry™ provides high-end cyber security aligned to industry standards and services (NERC CIP, AAA, Radius,
Application Notes RBAC, Syslog)
How-to Videos
Reduced relay-to-relay wiring and associated installation costs through high-speed inter-relay communications
Industry Expert Talks
Application flexibility with multiple I/O options including high density I/O, programmable logic, modularity, and specific
Subscribe customization
An integrated large, full color display, provides real-time visualization and control of the protected bay, via a bay mimic
as well as annunciator functionality and graphical visualization of phasors
Applications
Transformer asset monitoring using loss-of-life, aging factor, hottest spot
Applicable for transformers with up to six windings in a ring bus or breaker-and-a-half configuration
Reliable and secure protection for three-phase transformers, autotransformers, reactors, split-phase and phase angle
regulating transformers
Stand-alone or component in automated substation control system
CyberSentry enables UR devices to deliver full cyber security features that help customers to comply with NERC CIP and NITIR 7628
cyber security requirements through supporting the following core features:
Password Complexity
AAA Server Support (Radius)
Role Based Access Control (RBAC)
Event Recorder (Syslog for SEM)
Fully Compatible with the Multilin HardFiber System - Provides support for GE's IEC 61850 HardFiber Process Bus Solution:
Complete IEC 61850 Process Bus Solution providing resource optimization and minimizing total P&C life cycle costs. Learn More
The T60 offers RTD alarm and trip settings to provide advanced monitoring of power transformers’ temperature. In addition, the RRTD
module enables remote monitoring and metering of up to 12 programmable RTDs which reduces the number of RTD cables and
provides temperature backup protection (firmware version 5.70). Learn More