SatMac Monitor and Control Software for

Comtech EFData Corporation


CDM Modems and CSAT Transceivers

SatMac Configurations: Page 1 Comtech EFData Corporation


Using

SatMacTo configure the


CDM-500/550 Modem
and CSAT-5060 Transceiver
SatMac Configurations: Page 2 Comtech EFData Corporation
SatMac Direct Connect:
CDM-550/CDM-500
SatMac
CDM-500 Modem RS232 / RS485

CDM-550 Modem Remote Control Address:


RS232 = 0000
RS485 = 0001 -9999

CSAT-5060 SatMac RS232 / RS485


CSAT-5060
Transceiver
Remote Control Address:
RS232 = 0000 - 9999
RS485 = 0001 -9999

Modem RS232 default address is “0000”


Modem RS485 default address is “0001”

SatMac Configurations: Page 3 Comtech EFData Corporation


SatMac Direct Connect:
CSAT-5060

CDM-550/CDM-500
SatMac FSK
RS232 / RS485
IF Rx Cable
Remote Control Address:
RS232 = 0000 Address =
RS485 = 0001 -9999 Modem Address +1

1. ODU must be “enabled” on modem.


2. EDMAC sends messages to ODU address. (Modem address +1)
3. Modem passes commands through the FSK link.
4. ODU Serial Port is available at ODU address.

SatMac Configurations: Page 4 Comtech EFData Corporation


SatMac Direct Connect:
Using the RS485 Serial Bus for both devices:
RS485

CDM-550/CDM-500
SatMac FSK CSAT-5060
RS485
IF Rx Cable
Remote Control Address:
RS232 = 0000 Remote Control
RS485 = 0001 -9999 Address +1
RS232 = 0001
RS485 = 0002 -9999

1. If ODU = enable, the ODU will disable the local Serial Interface
for “X” seconds after reception of query Command on FSK link.
If ODU = disable, there is normal Serial Interface service.
2. Modem must set ODU address to RC-address +1 .
3. Modem passes commands through the FSK link.
4. If ODU = disable, any unused address is available.

SatMac Configurations: Page 5 Comtech EFData Corporation


SatMac Direct Connect:
CSAT On-Line

SatMac RS485
RS485

1:1 Switch
Module
CSAT Back-Up

1. SatMac can use “<0000/SPA=XXXX” to set ODU addresses.


2. Back-Up ODU will respond only to On-Line ODU address +1.
3. Only On-Line ODU will allow configuration changes.
4. On-Line ODU updates Back-Up ODU through dedicated link.
5. SatMac communicates directly with Back-Up ODU for
monitoring information only, no control is possible.

SatMac Configurations: Page 6 Comtech EFData Corporation


SatMac Direct Connect: CSAT On-Line

RS485/RS232 FSK
FSK
SatMac

1:1 Switch
Module

1. ODU = ENABLED in Modem


2. Modem uses “<0000/SPA=XXXX” to set ODU addresses. CSAT Back-Up

On-Line ODU = Modem Address +3


Back-Up ODU = Modem Address +4
3. Modem will only allow configuration changes on On-Line ODU .
4. On-Line ODU keeps Back-Up ODU current using dedicated link.
5. Modem gets Status from Back-Up ODU directly over FSK link.
6. ODU disables local Serial Port for “x” seconds after FSK activity is sensed.
Note: When Modem is in the “remote Mode”, all front panel activity is barred, including ODU.

SatMac Configurations: Page 7 Comtech EFData Corporation


SatMac / EDMAC Remote Connect:

SatMac RS485/RS232

Address = 0030 Address = 0031


Master Slave

Hub Site Set-Up: Far End Set-Up:


1. Modem: 2. Modem:
EDMAC Enabled, Master EDMAC Enabled, Slave
Set Address for modem Slave address = Master address +1
Set Address range for distant end

SatMac Configurations: Page 8 Comtech EFData Corporation


SatMac / EDMAC Remote Connect:

SatMac
RS485/RS232 Address = 0031 SSC
Slave Secondary
Serial
Address = 0030 Channel
CRS100
Master
Switch Module
Address = 0032
Slave

Far End Set-Up:


1. On-Line Modem is always “Master”.
2. EDMAC can only change configuration of On-Line Modem.
3. On-Line Modem will configure Back-Up Modem
4. Back-Up Status sent via SSC through Master to EDMAC.
5. Back-Up Modem never responds directly to EDMAC message.

SatMac Configurations: Page 9 Comtech EFData Corporation


SatMac / EDMAC Remote Connect:

CSAT On-Line
SatMac RS485/RS232
FSK
IF Rx Cable
Address = 0030
Master Address = 0031
Slave
Address = 0034

Far End Set-Up:


1. ODU = ENABLED in Modem
EDMAC Enabled
Slave Selected
2. Modem uses “<0000/SPA=XXXX” to set ODU addresses.
On-Line ODU = Modem Address +3
3. After “Slave Enabled”, Modem stops Modem/ODU polling, Menus locked out.
4. ODU will always delay 1.5 sec. After confirming Frequency Change Command
before changing frequency.

SatMac Configurations: Page 10 Comtech EFData Corporation


SatMac / EDMAC Remote Connect:
CSAT On-Line
Address = 0034

RS485/RS232
SatMac FSK
FSK
Address = 0030
Address = 0031
Master
Slave 1:1 Switch
Module

Far End Set-Up:


Address = 0035
CSAT Back-Up
1. ODU = ENABLED in Modem
EDMAC Enabled
Slave Selected
2. Modem uses “<0000/SPA=XXXX” to set ODU addresses.
On-Line ODU = Modem Address +3
Back-Up ODU = Modem Address +4
3. After “Slave Enabled”, Modem stops Modem/ODU polling, Menus locked out.
4. EDMAC allows changes only to On-Line ODU
5. EDMAC receives Status information directly over FSK from Back-Up ODU.

SatMac Configurations: Page 11 Comtech EFData Corporation


SatMac / EDMAC Remote Connect:
CSAT On-Line
Address = 0034
Address = 0031
Slave

RS485/RS232
SatMac FSK
SSC
Address = 0030 FSK
Master CRS100
1:1 Switch
Switch Module Address = 0032 Module
Slave

Far End Set-Up: Address = 0035


CSAT Back-Up
1. ODU = ENABLED in both Modems.
EDMAC Enabled on both Modems
Slave Selected on both Modems
2. On-Line Modem uses “<0000/SPA=XXXX” to set ODU addresses.
On-Line ODU = On-Line Modem Address +3
Back-Up ODU = On-Line Modem Address +4
3. After “Slave Enabled”, Modem stops Modem/ODU polling, Menus locked out.
4. EDMAC allows changes only through On-Line Modem to On-Line ODU
5. EDMAC receives Status information directly over FSK from Back-Up ODU.
**Available Q4 1999

SatMac Configurations: Page 12 Comtech EFData Corporation