CI/SfB (35) Xy
September 2012
Between us, ideas become reality ®
Armstrong’s Philosophies 1
Armstrong’s Commitment to the Environment 2
CE Marking 3
Armstrong Projects 4
The Range 5
TECHNICAL INFORMATION 6 - 22
Fire Tests 16
Load Capacity Matrix 20
PRODUCT RANGE
DESIGN OPTIONS
Axiom Transitions 22
Axiom Profiles 24
Axiom Classic Canopy 26
Axiom Knife Edge Canopy 28
Axiom Circle & Curved 30
Silhouette 15 XL2 32
Interlude 15 XL2 34
Microline 36
GENERAL APPLICATIONS
Prelude 15 38
Designed for Prelude 24 XL2 40
Prelude 24 TLX 42
CORRIDOR
Drywall Grid System Shortspan 54
Prelude Sixty2 55
SPECIFIC APPLICATIONS
Clean Room 24 mm Grid System 56
Corrosive Resistant 24 mm Grid System 58
Seismic Solution 60
LongSpan System 62
www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
ARMSTR ONG ’S P HILOS OPHIES
INTEGRATION
Suspension systems are designed for integration with
Armstrong's portfolio of ceiling products, mineral, soft fibre,
metal, wood and special solutions.
TEAM VALLEY
MOSCOW
MUNSTER
STAFFORD
VALENCIENNES
PONTARLIER RANKWEIL
BENTON HARBOUR
SHANGHAI
LAS VEGAS
MUMBAI
1
ARMSTR ONG’S COMMITMENT TO THE ENV IRONMENT
Our environmental efforts in the life-cycle of our products start with design.
DESIGN MANUFACTURING
• Innovative design creates stronger sections. • Suspension system Main Runners and Cross Tees are rotary stitched
• Reuse of waste materials by a patented method to deliver extra strength and stability.
• Raw materials for ceilings are renewable and abundant in nature. • All in process scrap is recycled back into the process.
• Recycled content varies by product: • Suspension systems and panels are manufactured at several
- Suspension system - contain 25% post-consumer recycled content locations, thereby reducing transportation costs and
environmental impacts associated with transportation.
fi
fi
RECYCLE INSTALLATION
• Suspension systems contain up to 25% post-consumer recycled content • Integrate technology to reduce installation time.
• End of Life ceiling tile recycling scheme. • Optimised packaging material - less waste on site.
• Up to 100% of the packaging is made from recycled material.
In several countries, we support the recollection of packaging.
fi
RETHINK PRODUCTS
fi
MAINTENANCE
fi
2 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
CE Marking
What is it ?
CE stands for Conformité Européenne, which translated For suspended ceilings, the way in which we must test
literally, means “European Conformity”. The CE mark is a and communicate performance for these essential
products “passport” for entry into the EEA (European requirements has been defined in EN 13964 Suspended
Economic Area) and indicates that the product complies Ceilings – Requirements and Test Methods.
with the requirements of the applicable European Directive.
For construction products the European Directive is the What does this mean?
Construction Products Directive (89/106/ EEC), however,
This standard identifies how the ceiling components must
this is being replaced by the Construction Products
be tested against the essential requirements to identify a
Regulations (305/2011/EU) which will come into full force
performance classification. It also indicates how the
on 1st July 2013.
manufacturer must ensure that their products maintain these
The CPD identifies the essential requirements for products levels of performance on an ongoing basis.
(and total projects) such that they are fit for intended use as:
On 1st July 2007, it became mandatory for all suspended
• mechanical resistance and stability; ceilings and accompanying suspension systems (in the
• safety in case of fire; scope of EN 13964) to carry the CE mark and the
• hygiene, health and environment; accompanying essential requirement test information.
• safety in use; Since 1st July 2007, non-CE marked materials are no longer
• protection against noise; saleable into the EEA.
• energy economy and heat retention.
3
ARMSTR ONG P R OJECTS
4
Concordia Hotel (IT) - Axiom C Canopy Dutch Technology Leiden (NL) - System Z
Medis Office (SI) - Silhouette Hospital Ruzomberok (SK) - Clean Room Grid.
5
THE SUSP ENSION R ANG E
• General applications, a range of standard Prelude 24mm and Prelude 15mm grid systems, Bandraster
and Prelude Sixty2 for longer spans. Drywall Grid Systems are available for plasterboard ceilings.
• Designer options including the minimalist grid Silhouette, Microline, Interlude and the Axiom range.
• Specific applications, for clean room and higher humidity environments.
• Perimeter trims and accessories, for most applications.
We also include our comprehensive programme of special size options that is available in most ranges.
A range of either stab or hook systems are available to meet the mechanical preferences of the installer.
To complete the portfolio we also offer a technical test programme that provides fire, loadings and
environmental accreditation.
Suspension systems are designed for use with a wide variety of Armstrong ceiling products, mineral, soft
fibre, metal, wood and special solutions.
Peakform is an innovative design for Main Runners and Cross Tees. The taller Peakform profiles are
engineered to create a stronger, more stable suspension system making installation both faster and easier.
Superlock is an industry first staked-on clip for Main Runners which provides tighter, secure bulb-to-bulb
connections; connections are confirmed by an audible click; Main Runners are easily disconnected and
reconnected laterally.
6 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
W HER E INNOVATION MEETS P ERF ORMANCE
DESIGNER GRIDS
Armstrong’s designer range, Silhouette, Microline, Interlude, Axiom
FULL RANGE OF ACCESSORIES
System and Axiom Canopies provide aesthetically enhanced grids.
Silhouette creates a level ceiling surface, providing a flush AND PERIMETER SOLUTIONS
appearance while Interlude gives a clean sophisticated visual that Suspension systems are offered with a complete
is created by the unique double reveal. Axiom Profiles and range of commonly required accessories and
Transitions provide an aesthetic solution for changes in level and perimeter solutions.
a flush transition with plaster margins. Axiom Canopies are a
perimeter trim system designed to create “ceiling clouds” in
conjunction with full size tiles. Microline is a steel based grid with
aluminium extrusion. The exposed sleeve provides a clean and crisp
visual plus a practical fluted
reveal for flexibility in partition
fixing and relocation.
7
AR MSTR ONG SYSTEMS
TL
TLX
PRELUDE XL2
8 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
PRELUDE XL2 “CLICK” INSTALLATION
Prelude XL2 Cross Tees in both 24mm and 15mm widths
feature an advanced stab system that locates with an audible
“click”, ensuring a solid installation at all times. The stab end
is precision stamped from a separate piece of high grade
steel permitting an increased accuracy and economy of
production over the more conventional integral forming of the
Cross Tee ends. A selected range of standard Prelude 15/24
XL2 Cross Tees feature the new Peakform design.
The Cross Tees are inserted to the right of each other
through the Main Runner slots and easily pushed home.
PRELUDE TLX
TLX is a new highly engineered staked-on hook system, with
a patented clip. Its unique steel-based composite material
and shape provide a stronger and level connection, an
improved fire performance and an increased overall
stability.TLX Cross Tees are quicker and easier to cut due to
the Peakform section.
When the TLX Cross Tees are inserted to the right of each
other through the Main Runner slots, the TLX clip provides a
more secure installation.
9
STANDAR D COLOURS
Armstrong suspension system components are manufactured in a range of colours and metal finishes including Global White to
complement Armstrong ceiling tiles. For complete information call Armstrong Technical Sales.
GLOBAL WHITE SILVER GREY CARRARA PLATINUM BLACK WHITE GLOBAL WHITE BRASS CHROME WHITE GALVANISED BLACK/WHITE
(GW) RAL 9006 (SG) (CA) (PN) (BK) RAL9010 (WR) (GW) (BS) (CE) RAL9010 (WR)
Prelude 24 TLX
Prelude 24 XL2
Prelude 15 XL2/TL
Interlude
Bandraster
Prelude 35
Prelude Sixty2
Corrosive Resistant
Axiom System
Painted perimeter trim items are available in Global White and capped angle T 1924 CA is available in all colours except black/white and galvanised.
Please contact Armstrong Technical Sales Group for further details.
10 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
COLOUR PALLET
• Stimulate your imagination to create vibrant interior spaces using custom colour solutions.
• Choice of more than 180 custom colours upon request.
• Available for Prelude 15 and Prelude 24 and specific perimeter trims.
DETAILS
15mm 24mm
Colour Selection Due to printing limitations, shade may vary from actual product.
RAL 1000 RAL 1001* RAL 1002 RAL 1003 RAL 1004 RAL 1005 RAL 1006 RAL 1007* RAL 1011 RAL 1012 RAL 1013* RAL 1014 RAL 1015*
RAL 1016 RAL 1017 RAL 1018 RAL 1019* RAL 1020 RAL 1021* RAL 1024 RAL 1027 RAL 1028 RAL 1032 RAL 1033 RAL 1034 RAL 2000*
RAL 2001 RAL 2002* RAL 2003 RAL 2004* RAL 2008 RAL 2010 RAL 2011 RAL 2012 RAL 3000* RAL 3001 RAL 3002* RAL 3003 RAL 3004
RAL 3005 RAL 3007 RAL 3009 RAL 3011 RAL 3012 RAL 3013 RAL 3014 RAL 3015 RAL 3016 RAL 3017 RAL 3018 RAL 3022 RAL 3027
RAL 3031 RAL 4001 RAL 4002 RAL 4003 RAL 4004 RAL 4005 RAL 4007 RAL 4008 RAL 4009 RAL 5000 RAL 5001 RAL 5002 RAL 5003*
RAL 5004 RAL 5005 RAL 5007 RAL 5008 RAL 5009* RAL 5010* RAL 5011 RAL 5012* RAL 5013 RAL 5014 RAL 5015* RAL 5018 RAL 5019
RAL 5020 RAL 5021 RAL 5022 RAL 5024 RAL 6000 RAL 6001 RAL 6002 RAL 6003 RAL 6004 RAL 6005 RAL 6006 RAL 6007 RAL 6008
RAL 6009 RAL 6010 RAL 6011* RAL 6012 RAL 6013 RAL 6014 RAL 6015 RAL 6016 RAL 6017 RAL 6018 RAL 6019 RAL 6020 RAL 6021
RAL 6022 RAL 6025 RAL 6026 RAL 6027 RAL 6028 RAL 6029 RAL 6032 RAL 7000 RAL 7001* RAL 7002 RAL 7003 RAL 7004 RAL 7005
RAL 7006 RAL 7008 RAL 7009 RAL 7010 RAL 7011 RAL 7012* RAL 7013 RAL 7015 RAL 7016* RAL 7021* RAL 7022 RAL 7023 RAL 7024
RAL 7026 RAL 7030* RAL 7031* RAL 7032* RAL 7033 RAL 7034 RAL 7035* RAL 7036 RAL 7037 RAL 7038* RAL 7039 RAL 7040* RAL 7044*
RAL 8000 RAL 8001 RAL 8002 RAL 8003 RAL 8004 RAL 8007 RAL 8008 RAL 8011 RAL 8012 RAL 8014* RAL 8015 RAL 8016 RAL 8017
RAL 8019* RAL 8022 RAL 8023 RAL 8024 RAL 8025 RAL 8028 RAL 9001* RAL 9002* RAL 9003* RAL 9004 RAL 9005* RAL 9010* RAL 9011*
RAL 9018* RAL 1023 RAL 2009 RAL 3020 RAL 4006 RAL 5017 RAL 6024 RAL 7042 RAL 7043 RAL 9016* RAL 9017
11
PR ODUCT SELECTOR
by application areas
PR ODUCT SELECTOR
by edge detail compatibility
Axiom Silhouette Interlude Microline Prelude Prelude Prelude Prelude Sixty2 Prelude Clean Room Corrosive Bandraster System Z
Transitions/ 15 15 15 24 XL2 24 TLX 35XL2 Resistant
Profiles
Mineral
Vector • • • •
MicroLook • • •
MicroLook BE • • • •
Tegular • • • • • • •
Board • • • • • • • •
SL2 • • • • • •
Metal
Metal MicroLook 8 • • • • •
Metal MicroLook 16 • •
Metal Tegular 2 • • •
Metal Tegular • • • •
8, 11F or 16
Metal Board • • •
12 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
TECHNICAL ICONS
Specific Applications/
Corridor Healthcare Environments
13
HEALTH AND CL EANLINES S
CLEAN ROOM
A clean room is a space or a series of spaces where the concentration of particles is controlled in order to minimise the
introduction, generation, retention of particles inside, generally for a specific industrial or research objective, as well as in
healthcare environments. Parameters such as temperature, humidity and relative pressure are also maintained at a precise
level, as defined in ISO 14644-1.
• Clean rooms are classified ISO 1 (cleanest) to ISO 9 depending on the number of particles measured.
• The performance is tested to ISO 14644-1 which determines the particle cleanliness class. Although US Federal
Standard 209E has been officially withdrawn, it is continuously used as a reference.
HEALTHCARE PREMISE
In healthcare premises, it is of critical importance to avoid hospital acquired infections.
According to the level of risk, the necessary clean room performance will vary, generally between ISO 5 and ISO 8.
All products below:
• can be used in ISO 5 environments and are certified against ISO 14644-1;
• inhibit growth of bacteria, moulds and yeasts tested against norms NF S 90-351, France, and JIS Z2801, Japan.
Intensive Care Anti-microbial Clean Room grid with plastic hold-down ISO 5
Recovery Room Good air-tightness clips Bioguard Acoustic or Metal Bioguard Washable
Maternity Good acoustical environment Extra Microperforated Rg 0701 with 0.65 Ȋw sound absorption
Laboratory Premium B15
Pharmacy
* Subject to local regulations. Please check with your Armstrong Technical Sales team.
14 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Did You Know... ? BIOGUARD products have been especially
designed for the healthcare sector.
System solutions for the pharmaceutical,
food and manufacturing industry can be
found in our brochure “Solutions for Clean
Room Environments”.
The BIOGUARD paint treatment has additional
active components which reduce the colony size
of virulent strains of bacteria, moulds and yeasts.
Clean Room Bioguard Bioguard Clean Room FL Metal Bioguard Metal Bioguard
Grid Plain Acoustic Extra Plain
Microperforated
Rg 0701 with
Premium B15
Classification Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2, 3 & 4
NF S 90-351
Surface PVC Bioguard paint Glass veil with Polyester film EXTRA PLAIN
Bioguard paint MICROPERFORATED with Bioguard
Rg 0701 with polyester powder
Bioguard polyester paint
powder paint
* Not tested
15
FIR E P ER FOR MANCES
REACTION TO FIRE
The harmonisation of technical Products Directive and national own building regulations.
standards within Europe, and the building regulation requirements for Depending upon the reaction to fire
integration of EN13964 (Suspended internal linings. test(s) conducted, the rating may
ceilings – requirements and test As reaction to fire is one of the include an additional classifications for
methods) into national legislation, essential safety requirements identified smoke production and flaming
means that there is now one series of for suspended ceilings, the Euroclass droplets. Smoke and flaming droplets
harmonised European test methods classification is one of the mandatory are regulated in some European
and classifications for the reaction to elements on the CE mark for countries.
fire of suspended ceilings. suspended ceiling tiles and grids. Smoke production is rated from s1
These new reaction to fire The ‘Euroclasses’ rate from A1 (the least smoke produced) to s3 (no
classifications, or ‘Euroclasses’, are through to F, with A1 being the best limit to amount of smoke produced).
defined in EN13501-1:2007. reaction to fire performance and F the Flaming droplets is rated from d0 (no
The ‘Euroclasses’ have replaced the worst. flaming droplets) to d2 (no limit to
old national fire reaction ratings for Each member state then sets the flaming droplets).
showing the performance of ceilings in performance level required for different
order to meet the Construction areas and building types within their
16 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Building Regulation performance table – internal linings
Assessed Performance Under Structural Steel Beams - Base Test Report: 134086 (70995 for Clip-In)
Metal Plain + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m3 AFBTF* pad
Metal Standard Perforated Rg 2516 + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m3 AFBTF* pad
Metal Microperforated Rd 1522 + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m3 AFBTF* pad
Metal Extra MicroperforatedRg 0701 + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m3 AFBTF* pad
17
INSTALL ATION & MAINTENANCE
SAFETY
Armstrong’s commitment on safety concerns each and every step of
our business:
• in our plants & offices, we have implemented rigorous safety
policies and procedures to help minimise risk
• for our products, for which we ensure compliance with
appropriate European and local safety regulations.
• on the jobsite, safety is crucial for our partners:
Armstrong therefore recommends the handling,
installation & maintenance of our solutions in
accordance with the European standards and /or
local regulations, for the safety of the
installers & of the end users.
GENERAL ADVICE
Yes No
18 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
INSTAL L ATION & MAINTENANCE
1 B 2 3
2 Min 100 mm
M
A 600 1000 A
800
300 mm
1. Planning grid layout 2. Mark the perimeter trim lines 3. Installation of perimeter trims
4 Max 5 6
600 mm
1200 mm
B (Main Runner)
1200 mm
1200 mm
B (Main Runner)
7 8 9
7. Installation of Main Runners 8. Cross Tees installation right to right 9. Cutting Cross Tees
10 11 12
A /B
A /B
10. Installation of tiles 11. Measure and cut 12. Re-tegulating Tegular or MicroLook tiles
perimeter tiles
POST INSTALLATION
After the installation of a suspended ceiling system it is important to ensure that it is properly maintained and that any
additional works are not detrimental to the performance of the ceiling installation. Maintenance operations must only be
undertaken after the technical impact on the ceiling system has been completely evaluated. For example, hangers should not
be removed, adapted or bent without fully understanding the consequences and taking any appropriate mitigating actions.
Armstrong suspension systems do not need any more maintenance than normal painted metal surfaces. However, if cleaning
is required dust and superficial dirt can easily be removed with a soft brush or a vacuum cleaner with a brush attachment.
For more stubborn marks a lightly dampened cloth or sponge can be used, although never use abrasive products.
Some companies specialise in chemical cleaning solutions. These should only be undertaken after a test on a small hidden
area of grid proves acceptable.
Most Armstrong suspension systems can be redecorated, however, consideration should be given to the effect on the fire
reaction performance of the grid. Ceiling tiles should be removed, however, the grid can usually be painted in situ. If a firm of
professional decorators is used, assurances should be sought that the necessary performances will be maintained. It should
be noted that any repainting would invalidate Armstrong's warranty for the product.
For a copy of Armstrong's Suspension Systems Calculation Guide, please contact Armstrong Technical Sales.
19
LOAD CAPACIT Y MATR IX
Loading is an important property of suspended ceiling grid systems both for the mechanical safety of the suspended
ceiling and its visual appearance.
In the EEA, table 6 of the suspended ceiling product standard, EN 13964:2004+A1:2006, defines 3 classes of
deflection, the best being Class 1 which is L/500 (but no greater than 4mm).
The test method on which the European calculations of loadbearing capacity are based upon is also defined in EN
13964, and considers the influence of both deflection and bending moment.
The individual product pages in the second half of this brochure include a table giving the maximum uniform
distributed load, based on different hanger centres, in accordance with Class 1 deflection, as defined in EN
13964:2004 + A1:2006.
For markets outside of the EEA different deflection limits are sometimes required. The tables on this page show the
maximum uniform distributed load for the deflection limits shown, but taking into account deflection only. These
values are calculated based upon load values determined from laboratory tests in accordance with the EN 13964
test method.
For longer spans, some of the criteria shown on this page may give quite large deflection values. Armstrong
recommends a maximum of 4mm deflection between points of suspension for all grid components, irrespective of
span, for aesthetic reasons. Therefore the numbers in the tables on this page are the maximum loads permitted to
meet the give a deflection criteria (such as L/400) but up to a maximum value of 4mm.
System Load Summary (1200 x 1200 layout) - Max Load kg/m2 - Deflection factor only
System Main Runner Primary Secondary L/500 L/400 L/360 L/300 L/250
Cross Tee Cross Tee
Prelude 24 XL2 314032 A 313051 B 312021 A 13,3 16,8 18,8 22,7 22,7
Prelude 24 TLX 314032 A 133031 132031 13,3 16,8 18,7 22,7 22,7
Prelude 15 XL2 304033 A 303033 B 302033 B 13,1 16,5 18,5 22,3 22,3
Prelude 15 TL 304033 A 103033 A 102033 A 13,1 16,5 18,5 22,3 22,3
Microline CS 25 42 92 WR CS 25 30 42 WR CS 25 20 42 WR 12 15 17 20.5 20.5
2
Silhouette 15 XL 804042 G 803042 G 802042 G 11,4 14,4 16,1 19,5 19,5
Interlude 15 XL2 614042 G 613042 G 612042 G 14,5 18,3 20,4 24,7 24,7
Prelude 35 XL2 224042 243042 242042 13,9 17,7 19,8 24 24
Prelude 24 Corrosive
Resistant - TLX 284042 143032 142032 13,3 16,8 18,7 22,7 22,7
Clean Room 24 EA794044 EA793044 EA792044 12,8 16,3 18,2 22,1 22,1
1200mm 600mm 1
spacing
1200mm
Cross Tees
MR MR
20 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
System Load Summary (1200x1800 layout) - Max Load kg/m2 - Deflection factor only
System Main Runner Primary Secondary L/500 L/400 L/360 L/300 L/250
Cross Tee Cross Tee
Prelude 24 XL2
314032 A 313431 A 312021 A 6,5 7,3 7,3 7,3 7,3
(1800 span)
Prelude 24 TLX
314032 A 133432 132031 6,5 7,3 7,3 7,3 7,3
(1800 span)
1200mm 600mm 1
spacing
1800mm
Cross Tees
MR MR
System Load Summary (1800x1800 layout) - Max Load kg/m2 - Deflection factor only
System Main Runner Primary Secondary L/500 L/400 L/360 L/300 L/250
Cross Tee Cross Tee
Prelude Sixty2 24 - XL2 404093 G 313431 A 312021 A 6,5 7,3 7,3 7,3 7,3
Prelude Sixty2 24 - TLX 404093 G 133432 132031 6,5 7,3 7,3 7,3 7,3
1800mm 600mm
spacing
1800mm
Cross Tees
MR MR
21
Design Options
AXIOM TRANSITIONS
The 5 sections are designed to provide a flush transition between plaster margin and
mineral, metal or wooden suspended ceilings.
Axiom Transitions
Item Nr. Description Dimensions Content / Carton Weight / Carton Cartons / Pallet
length (mm) height (mm) pcs lm kg
25 15
50
T 3219 G (1) Axiom Transitions channel 3000 50 10 30,00 17,10 36
15
25 15 19
50
T 3215 G (1) Axiom Transitions angle 3000 50 10 30,00 15,00 36
15
25 15 15
50
T 3210 G (1) Axiom Transitions for 3000 50 10 30,00 11,80 36
11
Vector tiles
25 15
35
A 321 G
A 322 G
A 340 G
A 338 G
A 339 G
23
Design Options
AXIOM PROFILES
Available in 5 heights with a plasterboard trim section, Axiom Profiles are compatible
with 24 mm and 15 mm grid systems including designer grid.
Axiom Profiles
Item Nr. Description Dimensions Content / Carton Weight / Carton Cartons / Pallet
length (mm) height (mm) pcs lm kg
19
56 42 06 G (1) Axiom Profiles 150 mm 3000 150 5 15,00 14,70 30
200
112
150
50
55 14 11 G (1) Axiom Vector Profiles 112 mm 3000 112 5 15,00 12,20 15
24 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Design Options
AXIOM PROFILES
System Drawing
A 344 G
A 344 G
A 334 G A 340 G
A 335 G
A 336 G
A 337 G
A 345 G
A 338 G
A 339 G
≤ 200 A
100
25
Design Options
AXIOM C CANOPY
Axiom C Canopy is a perimeter trim system designed to create “ceiling clouds” in conjunction with full size tiles.
Made from standard ceiling panels and ready to assemble Axiom components, Axiom C Canopy will define and
individualise any space.
112 mm
112 mm
3000 x 1200 mm AX 52 G15 AX 52 G24 • Make sure the installation is clean and safe.
26 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
AXIOM C CANOPY
Design Options
System Drawing
4 Universal T bar
connector clips
8 XL2
connector clips
6 Universal T bar
connector clips
4 Corner
posts
4 Axiom profiles
cut to size
3 C channels
6 Channel brackets cut to size
6 T bar hangers
12 Cross Tees
600 mm XL2
(24 mm or 15 mm)
2 Main Runners cut to size
(24 mm or 15 mm)
OPTION 1
Aircraft cable & Gripple connectors
OPTION 2
Quick hanger*
OPTION 3
* not included in the kit
6 mm Threaded rod*
27
Design Options
AXIOM KE CANOPY
Axiom KE Canopy is an aesthetic perimeter trim system designed to create “ceiling clouds” in conjunction
with full size tiles. Made from standard ceiling panels and ready to assemble Axiom components, Axiom KE Canopy
is a quick refurbishment solution, ideal for acoustically challenged or open plenum spaces.
106 mm
CS 57 42 06 G Axiom KE Profile
Vector
Cut to size Main Runner
600mm XL2 Cross Tees
106 mm
28 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Design Options
AXIOM KE CANOPY
System Drawing
6 Universal T bar
connector clips
8 Corner splice
connectors
16 Axiom
universal splice
plates
6 Channel brackets
4 Mitre
Corners
6 T bar hangers
3 C channels
2 Main Runners cut to size cut to size
(24 mm or 15 mm)
OPTION 1
Aircraft cable & Gripple connectors
OPTION 2
Quick hanger*
OPTION 3
* not included in the kit
6 mm Threaded rod*
29
Design Options
AXIOM CIRCLE & CURVED
The Axiom Circle & Curved Canopies are an aesthetic perimeter trim system designed to create “ceiling clouds” in
conjunction with full size tiles. Made from standard ceiling panels and ready to assemble Axiom components, Curved
and Circle Canopies allow specifiers to play with different planes and levels as well as conceal service elements.
Tegular / MicroLook
30 20 33 B Prelude XL2 Cross Tee 600 mm T15 or
31 20 21 A Prelude XL2 Cross Tee 600 mm T24
3m x 3m Canopy
30 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Design Options
AXIOM CIRCLE & CURVED
System Drawing
Splice connector
6 Channel brackets
OPTION 1
Aircraft cable & Gripple connectors
OPTION 2
Quick hanger*
OPTION 3
6 mm Threaded rod* * not included in the kit
31
Design Options
SILHOUETTE 15 XL 2
Exposed 15 mm grid system (nominal).
Silhouette 15 XL2 is a suspension system designed to create a crisp, clean look in conjunction with MicroLook
tiles to provide an enhanced aesthetic.
with 6 mm reveal
80 40 42 G(1) 3600 44 20 72,00 24,50 36
80 39 43 G(1) 3125 44 20 62,50 25,40 25
80 44 42 G(1) 2700 44 20 54,00 18,40 30
with 3 mm reveal
81 40 42 WRG(2) 3600 44 20 72,00 24,50 36
with 6 mm reveal
80 30 42 G(1) 1200 44 60 72,00 24,50 35
80 31 43 G(1) 1250 44 60 75,00 23,80 35
80 33 42 G(1) 1350 44 30 40,50 13,80 50
80 32 42 G(1) 1000 44 60 60,00 20,40 24
with 3 mm reveal
81 30 42 WRG (2) 1200 44 60 72,00 24,50 35
Section Drawings
Length
3600 300 600 3 x 600 600 300
3500 250 500 4 x 500 500 250
3125 312,5 625 2 x 625 625 312,5
2700 337,5 675 675 675 337,5
Length
All products standard in Global White unless indicated by index (2). Other standard colours available for item
numbers with index (1). See details below.
(1) Silhouette with 6 mm reveal is available in white, black (BK) or white with black reveal (BI).
(2) WR = White RAL 9010 (WR)
All measurements in millimetres. All sizes are nominal.
32 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Design Options
SILHOUETTE 15 XL 2
Silhouette 15 XL2
- Pre-mitred intersections
- Choice of either 6 or 3 mm reveal dimension
- Silhouette 15 XL2 with 3 mm reveal is supplied as Perimeter Solutions
standard in RAL 9010 white to compliment Armstrong metal tiles
Section
Cross Tee trimmed to wall angle
Section
Axiom Profiles
MCC4 G
(50, 100, 112, 150 and 200 mm heights available)
Mitre closure clip for 6 mm reveal
Silhouette 15 XL2 system
A 339 G
Axiom universal T bar connector clip
Hanger spacing
1) Values in the above table conform to Class 1 as defined in EN
Tile weight Main Runner spacing 1200 mm Main Runner spacing 600 mm
600 mm XL Cross Tee 13964:2004+A1:2006 table 6.
1200 mm XL Cross Tee
2 2
For other classes /deflection limits please contact your local Armstrong
80 30 42 G 80 20 42 G
Technical Sales team.
2,5 kg/m2 1800 2100
2) Values are determined from laboratory tests methods in accordance with
3,0 kg/m 2 1700 2100 EN 13964:2004+A1:2006 clause 5.
3,5 kg/m 2 1650 2050 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum
4,0 kg/m 2 1600 2000 deflection of the grid is L/500 but not greater than 4 mm (L = span).
5,0 kg/m 2 1500 1900 4) No other applied loads such as luminaires, air diffusers, smoke
5,5 kg/m 2 1450 1850 detectors, sprinklers, hanging signs etc. are permitted.
6,0 kg/m 2 1400 1800 5) No overlays such as mineral wool or fibre glass quilts, as may be required for
7,0 kg/m 2 1300 1700 enhanced acoustic, fire or thermal performance, are permitted unless their full
weight is established and included, together with the weight of the tile, within
8,5 kg/m 2 1200 1600
the appropriate weight groups.
10,5 kg/m2 1100 1550
6) For grid loading data calculated to different criteria than Class 1 to
13,0 kg/m2 950 1350 EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.
33
INTERLUDE 15 XL 2
Design Options
Section Drawings
Length
Length
1200 600 600
600 / 300
34 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Design Options
INTERLUDE 15 XL 2
Interlude 15 XL2
Section
Section
UPC AG
Universal partition clip
attaches to grid to provide fixing
3. Bend away from bulb to snap off centre rail for partition head track: reversible for
15 mm or 24 mm grid systems
Hanger spacing
1) Values in the above table conform to Class 1 as defined in EN
Tile weight Main Runner spacing 1200 mm Main Runner spacing 600 mm
600 mm XL2 Cross Tee 13964:2004+A1:2006 table 6.
1200 mm XL2 Cross Tee
61 30 42 G 61 20 42 G For other classes /deflection limits please contact your local Armstrong
Technical Sales team.
2,5 kg/m 2
1950 2100 2) Values are determined from laboratory tests methods in accordance with
3,0 kg/m 2
1850 2100 EN 13964:2004+A1:2006 clause 5.
3,5 kg/m 2
1750 2100 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum
4,0 kg/m 2
1750 2100 deflection of the grid is L/500 but not greater than 4 mm (L = span).
5,0 kg/m 2
1650 2050 4) No other applied loads such as luminaires, air diffusers, smoke
5,5 kg/m 2
1600 2000 detectors, sprinklers, hanging signs etc. are permitted.
6,0 kg/m 2
1550 1950 5) No overlays such as mineral wool or fibre glass quilts, as may be required for
7,0 kg/m 1450 enhanced acoustic, fire or thermal performance, are permitted unless their full
2
1850
weight is established and included, together with the weight of the tile, within
8,5 kg/m 2
1350 1750 the appropriate weight groups.
10,5 kg/m 2
1250 1650
6) For grid loading data calculated to different criteria than Class 1 to
13,0 kg/m 2 1100 1550 EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.
35
Design Options
MICROLINE 15 XL 2
Steel based grid with aluminium extrusion. The exposed sleeve provides a clean and crisp visual plus
a practical fluted reveal for flexibility in partition fixing and relocation.
15 mm
CS 25 30 42 WR 1200 44 60 72 26,00 72
44 mm
15 mm
44 mm
15 mm
Section Drawings
600/750
36 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Design Options
MICROLINE 15 XL 2
Key Attributes Physical Data
• Peakform • Material
Patented universal Main Runner and Cross Tee design Chassis : Double web galvanised steel
increase strength and stability for improved performance Sleeve : Extruded aluminium
and makes the grid easier to cut. • Surface finish of the sleeve
The aluminium sleeves must be cut aside using a Baked polyester paint
hand saw.
• Product Family
• For metal tiles with MicroLook 8mm edge Designer grids
• Fluted reveal for M6 bolt • Main Runner / Cross Tee Interface
Pre-mitred intersections
• End Detail
Main Runner : bulb-to-bulb connection
Cross Tees : staked-on stab clip
• Colour
Available in white (RAL9010) only
Perimeter Options*
40
T 2040 H WR A Perimeter channel RAL 9010 3050 20 61,00 18,10
C 1803 H Perimeter wedge 200 100 - 5,00
*Made up of steel
20 C 1803 H
T 2040 H WR A
Perimeter channel and perimeter wedge for cut modules
Microline XL2 System The following table gives the maximum permitted hanger distance (mm) along the Main Runner
9,0 kg/m 2 1200 1650 1500 6) For grid loading data calculated to different criteria than
1150 1600 Class 1 to EN13964:2004+A1:2006, see the grid loading
10,0 kg/m 2 1400
technical section on pages 20 - 21.
14,0 kg/m 2 - 1350 1200
37
General Applications
PRELUDE 15
Exposed 15 mm grid system (nominal).
Universal Main Runners Prelude 15 Peakform and Superlock Clip (bulb-to-bulb connection)
Section Drawings
Length
3750 78,125 156,25 21 x 156,25 156,25 78,125
3600 50 100 33 x 100 100 50
3375 337,5 675 2 x 675 675 337,5
2
Cross Tee Prelude 15 XL Cross Tee Prelude 15 TL
Length Length
All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below.
(1)Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR).
(2) Also available in RAL 9010 (WR).
Cross tee alignment is achieved by locating the tees to the right-hand side of the adjoining section.
All measurements in millimetres. All sizes are nominal.
38 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
General Applications
PRELUDE 15
6 Tile Main Runner Hanger centres 1 Main Runner 2 Cross Tee 3 Cross Tee 4 Hanger 7 Universal
centres 1200 mm 600 mm retaining clip
600 x 600 mm 1200 mm 1200 mm 0,84 lm 1,67 lm 0,84 lm 0,70 pcs 5,56 pcs
2,78 pcs
600 mm 1200 mm 1,67 lm - 1,67 lm 1,40 pcs 5,56 pcs
1200 x 600 mm 1200 mm 1200 mm 0,84 lm 1,67 lm - 0,70 pcs 5,56 pcs
1,39 pcs
600 mm 1200 mm 1,67 lm - 0,84 lm 1,40 pcs 5,56 pcs
5 Perimeter trim approx. 0,70 lm/m 2 The chart is for general guidance only.
Hanger spacing
Tile weight Main Runner spacing 1200 mm Main Runner spacing 600 mm Main Runner spacing 1200 mm Main Runner spacing 600 mm
1200 mm TL Cross Tee 600 mm TL Cross Tee 1200 mm XL2 Cross Tee 600 mm XL2 Cross Tee
10 30 33 A 10 20 33 A 30 30 33 B 30 20 33 B
2,5 kg/m 2
1900 2100 1900 2100
3,0 kg/m 2
1800 2100 1800 2100
3,5 kg/m 2
1750 2100 1750 2100
4,0 kg/m 2
1650 2050 1650 2050
5,0 kg/m 2
1550 2000 1550 2000
5,5 kg/m 2
1550 1950 1550 1950
6,0 kg/m 2
1500 1900 1500 1900
7,0 kg/m 2
1400 1800 1400 1800
8,5 kg/m 2
1300 1700 1300 1700
10,5 kg/m 2
1150 1600 1150 1600
13,0 kg/m 2
1050 1500 1050 1500
39
PRELUDE 24 XL2
General Applications
Universal Main Runners Prelude 24 Peakform and Superlock Clip (bulb-to-bulb connection)
Section Drawings
Length
Length
All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below.
(1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR).
(2) Also available in RAL 9010 (WR).
Cross tee alignment is achieved by locating the tees to the right-hand side of the adjoining section.
All measurements in millimetres. All sizes are nominal.
40 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
General Applications
PRELUDE 24 XL2
6 Tile Main Runner Hangers 1 Main Runner 2 Cross Tee 3 Cross Tee 4 Hanger 7 Universal
centres centres 1200 mm 600 mm retaining clip
1200 x 600 mm 1200 mm 1200 mm 0,84 lm 1,67 lm - 0,70 pcs 5,56 pcs
1,39 pcs
600 mm 1200 mm 1,67 lm - 0,84 lm 1,40 pcs 5,56 pcs
600 x 600 mm 1200 mm 1200 mm 0,84 lm 1,67 lm 0,84 lm 0,70 pcs 5,56 pcs
2,78 pcs
600 mm 1200 mm 1,67 lm - 1,67 lm 1,40 pcs 5,56 pcs
Prelude 24 XL2 System The following table gives the maximum permitted hanger distance (mm) along the Peakform Main Runner
(31 40 32 A) for the tile weights and Main Runner spacings noted.
Hanger spacing
Tile weight Main Runner spacing 1800 mm Main Runner spacing 1200 mm Main Runner spacing 600 mm
1800 mm XL2 Cross Tee 1200 mm XL2 Cross Tee 60 mm XL2 Cross Tee
31 34 31 A 31 20 21 A
31 30 51 B
2,5 kg/m 2 1650 1900 2100
3,0 kg/m 2 1600 1800 2100
3,5 kg/m 2 1500 1750 2100
4,0 kg/m 2 1450 1700 2100
5,0 kg/m 2 1350 1600 2000
5,5 kg/m 2 1350 1550 1950
6,0 kg/m 2 1250 1500 1900
7,0 kg/m 2 - 1450 1800
8,5 kg/m 2 - 1300 1700
10,5 kg/m 2 - 1200 1600
13,0 kg/m 2 - 1050 1500
Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.
41
General Applications
PRELUDE 24 TLX
Exposed 24 mm grid system (nominal).
Universal Main Runners Prelude 24 Peakform and Superlock Clip (bulb-to-bulb connection)
Section Drawings
Length
Length
900 / 750 / 675 / 625 / 600 / 500
1875 312,5 4 x 312,5 312,5
1800 300 4 x 300 300
1724 262 4 x 300 262
1500 150 350 / 2 x 250 / 350 150
1350 337,5 2 x 337,5 337,5
1250 312,5 2 x 312,5 312,5
1200 300 2 x 300 300
1000 250 2 x 250 250
All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below.
(1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE) and White RAL 9010 (WR).
(2) Also available in Black (NG), Brown (MR) and Beige (BJ).
Cross tee alignment is achieved by locating the tees to the right-hand side of the adjoining section.
42 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
General Applications
PRELUDE 24 TLX
6 Tile Main Runner Hanger 1 Main Runner 2 Cross Tee 3 Cross Tee 4 Hanger 7 Universal
centres centres 1200 mm 600 mm Retaining Clip
1200 x 600 mm 1200 mm 1200 mm 0,84 lm 1,67 lm - 0,70 pcs 5,56 pcs
1,39 pcs
600 mm 1200 mm 1,67 lm - 0,84 lm 1,40 pcs 5,56 pcs
600 x 600 mm 1200 mm 1200 mm 0,84 lm 1,67 lm 0,84 lm 0,70 pcs 5,56 pcs
2,78 pcs
600 mm 1200 mm 1,67 lm - 1,67 lm 1,40 pcs 5,56 pcs
2
5 Perimeter Trim approx. 0,70 lm/m The chart is for general guidance only.
Hanger spacing
Tile weight Main Runner spacing 1800 mm Main Runner spacing 1200 mm Main Runner spacing 600 mm
1800 mm TLX Cross Tee 1200 mm TLX Cross Tee 600 mm TLX Cross Tee
13 34 32 13 30 31 13 20 31
2,5 kg/m 2 1650 1900 2100
3,0 kg/m 2 1600 1800 2100
3,5 kg/m 2 1500 1750 2100
4,0 kg/m 2 1450 1700 2100
5,0 kg/m 2
1350 1600 2000
5,5 kg/m 2
1350 1550 1950
6,0 kg/m 2
1250 1500 1900
7,0 kg/m 2
- 1450 1800
8,5 kg/m 2
- 1300 1700
10,5 kg/m 2
- 1200 1600
13,0 kg/m 2
- 1050 1500
Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.
43
General Applications
PRELUDE SIXTY 2
Exposed 24 mm grid system (nominal).
Double Peakform Main Runner section requiring less suspension points and compatible with
Prelude 24 XL 2 and TLX Cross Tees. For corridor applications please see page 50 - 51.
Universal Main Runner Prelude Sixty2 Double Peakform with Superlock Clip (bulb to bulb connection)
Length
All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below.
(1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR).
(2) Also available in Black (NG), Brown (MR), Beige (BJ).
(3) Also available in RAL 9010 (WR).
All measurements in millimetres. All sizes are nominal.
44 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
General Applications
PRELUDE SIXTY 2
3 Tile Main Runner centres 1 Main Runner 2 Cross Tee 1800 mm 2 Cross Tee 1200 mm 2 Cross Tee 600 mm
Accessories
45
PRELUDE 35 XL 2
General Applications
White capping
24 40 42 3600 43 16 57,60 22,20 20
Galvanised capping
43 mm
24 40 42 UP 3600 43 16 57,60 23,50 20
Black capping
35 mm 24 40 42 BK 3600 43 16 57,60 22,20 20
Perimeter Trim
Item Nr. Description Dimensions Content / Carton Weight / Carton Cartons / Pallet
length (mm) height (mm) pcs lm kg
Section Drawings
Length
Length
Cross Tee alignment is achieved by locating the tees to the right-hand side of the adjoining section.
All dimensions in millimetres. All sizes are nominal.
46 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
PRELUDE 35 XL 2
General Applications
Key Attributes Physical Data
• Peakform • Material
Patented universal Main Runner and Cross Tee design Double-web galvanised steel
increase strength and stability for improved performance
• Surface Finish
and makes the grid easier to cut
Baked polyester paint
• Product Family
• Rotary stitched
Exposed tee system
Main Runner and Cross Tees for additional torsional
strength and extra stability during installation • Main Runner / Cross Tee Interface
Joggled ends
• End Detail
Main Runner : with Superlock clip, by pass coupling,
single stitching
Cross Tees : staked-on stab clip, double stitching
• Colour
Available in White, Galvanised and Black.
The following table gives the maximum permitted hanger distance (L) along the Main Runner (24 40 42).
Hanger spacing
Tile weight Main Runner spacing 1990 mm Main Runner spacing 1500 mm Main Runner spacing 1200 mm Main Runner spacing 600 mm
(x 1000 mm) (x 1000 mm) (x 600 mm) (x 600 mm)
1990 mm XL2 Cross Tee 1500 mm XL2 Cross Tee 1200 mm XL2 Cross Tee 600 mm XL2 Cross Tee
24 06 42 24 36 42 24 30 42 24 20 42
2,5 kg/m2 1700 1900 1900 2000
3,0 kg/m2 1600 1800 1850 2000
3,5 kg/m2 1550 1700 1750 2000
4,0 kg/m2 - 1650 1700 2000
4,5 kg/m2 - 1600 1650 2000
5,0 kg/m2 - 1550 1600 2000
5,5 kg/m2 - 1500 1550 1950
6,0 kg/m2 - 1400 1500 1900
6,5 kg/m2 - 1350 1500 1900
7,0 kg/m2 - 1300 1450 1850
8,0 kg/m2 - 1250 1400 1750
9,0 kg/m2 - - 1300 1700
10,0 kg/m2 - - 1250 1650
12,0 kg/m2 - - 1150 1550
14,0 kg/m2 - - 1050 1450
47
General Applications
BANDRASTER
Bandraster is a suspension system available in a wide range of widths,
compatible with Prelude 24 TLX/XL 2 Cross Tees.
Bandraster Systems
36mm
Unslotted (2)
36 0050 A 3600 50 8 28,80 24,00 28
36 0075 A* 3600 75 8 28,80 27,70 20
36 0100 A 3600 100 8 28,80 31,40 16
36 0125 A 3600 125 8 28,80 38,30 12
36 0150 3600 150 4 14,40 21,20 20
(1) Is compatible with all plank edge details whether cross tees are required or not.
(2) Is compatible with only with plank edge details when no visible cross tees span between bandraster sections.
Bandraster Accessories
System Drawing
- Slotted Bandraster is compatible either with Prelude 24 XL2 or Prelude 24 TLX Cross Tees
- On special request: Prelude 15 TL can be made compatible for
installation with slotted Bandraster;
- Special spaced slotting; minimum slot spacing is 50 mm;
Maximum length of Bandraster is 5000 mm
Nonius hanger
Cross
connector
Crossing element
Wall connector
Threaded rod
A 1829 G
49
General Applications
SYSTEM Z
Semi-concealed and concealed systems.
Provides specialist solution for corridors giving a monolithic visual.
Can also be used for room situations in conjunction with Prelude 24 and Bandraster grid.
Semi-Concealed
CZ 3600 H
CA 21 G Z connector 150 500 - 10,00
CA 21 G
50 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
General Applications
SYSTEM Z
Semi-Concealed (continued)
CC 4000 G
System Drawing
Semi-concealed SL2
Corridor installation
SL2
Perimeter trim according to circumference of room The chart is for general guidance only.
2
Perimeter angles should be of thicker material when corridor wider than 1,80 m.
51
General Applications
DRYWALL GRID SYSTEM
The Drywall Grid System (DGS) is a quick and easy to install suspension
system for plasterboard ceilings, available in a range of two unique systems :
Standard for typical flat installations and Faceted for curved and domed ceilings.
Main Runners
7940 G slot at 150mm 3600 38 38 12 43,20 20 36
7942 G slot at 150mm 3000 38 38 12 36,00 17 36
7941 G slot at 100mm 3600 38 38 12 43,20 19,52 36
Cross Tees
7930 G 1200 38 38 36 43,20 20 48
7918 900 38 38 36 33,00 15 48
7920 G 600 38 38 36 21,60 10 96
19
Unhemmed C channel
7838 G 3048 (120") 40 20 60.96 16 32
Accessories
A variety of Drywall Grid accessories are available to provide problem solving solutions that save time, labour and money.
DW30C AG XTAC AG
DW45C AG Cross Tee adapter clip
DW60C AG
DW90C AG
Drywall angle clips
DLCC AG
DW58 LTAG RC2 AG Direct load ceiling clip
Transition clip for 15 mm Radius clip
plasterboard (5/8")
MBAC AG BP DWC AG
Main Runner Drywall clip
adapter clip
52 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
General Applications
DRYWALL GRID SYSTEM
Section Drawing
Main Runner
Length
Faceted Main Runners faceted at 203mm centres. Use for radius 4.50m or less
HD 8906 F08 G
(54 slots) 3658mm
Faceted at 406mm centres. Use for radius over 4.50m (directional Main Runner)
HD 8906 F16 G
(45 slots) 3658mm
Cross Tees
7930 G 1200mm
7920 G 600mm
7918 G 900mm
System Drawing
Main Runner
Cross Tee
For more information, please ask for the Drywall Grid System Curved and Flat brochure.
53
Corridor
DRYWALL GRID SYSTEM SHORTSPAN
The Drywall Grid System (DGS) ShortSpan is a quick and easy to install suspension system for
plasterboard ceilings and in particular for corridors in both commercial and residential installations.
Shortspan T-bars
S 7708 G 2438 (8') 38 12 29,26 13 24
S 7710 G 3048 (10') 38 12 36,57 17 24
S 7712 G 3658 (12') 38 12 43,89 20 24
S 7714 G 4267 (14') 38 12 51,20 23 24
System Drawing
Alignment
crimps
Locking
tab
For more information, please ask for the Drywall Grid System Standard and Faceted brochure.
54 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Corridor
PRELUDE SIXTY 2
Exposed 24 mm grid system.
Double Peakform Main Runner section requiring less suspension
points and compatible with Prelude 24 XL 2 and TLX Cross Tees.
Universal Main Runner Prelude Sixty 2 Double Peakform and Superlock Clip (bulb to bulb connection)
The Prelude Sixty2 system is designed for use in corridor applications, with or without
Cross Tees, and where spans do not exceed 3750 mm. For a wider configuration, the
Main Runner is compatible with the Prelude 24 TLX and XL2 Cross Tees.
Special length and modulation made to order, with and without slots, please contact
your Armstrong Technical Sales team.
Accessories
System Drawing
Perimeter trim
Prelude Sixty2 300 37,2 32,8 29,1 25,9 23,2 20,9 18,9 17,2 15,6 14,3 13,1 11,8 10,0 8,5 7,1
Butt cut 600 18,6 16,4 14,5 13,0 11,6 10,5 9,5 8,6 7,8 7,1 6,5 5,9 5,0 4,2 3,5
1200 9,3 8,2 7,3 6,5 5,8 5,2 4,7 4,3 3,9 3,5 3,2 - - - -
(1) Colours available: Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Chrome (CE), White RAL 9010 (WR), Brass (BS).
55
Specific Applications
CLEAN ROOM GRID SYSTEM
Exposed 24 mm grid system (nominal). A complete system solution: Aluminium construction for maximum corrosion
resistance and non-magnetic environments. Co-extruded with a unique factory applied gasket for a better seal between
tile and grid. System suitable for use in applications up to Class 4 performance as per Class ISO standard 14644-1.
Accessories
CHDC A 426
Hold down clip suitable for 18 Board access clip
non-magnetic areas
12 16
Section Drawings
Length
3600 150 300 9 x 300 300 150
Length
1200 300 300 300 300
600 300 300
56 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Specific Applications
CLEAN ROOM GRID SYSTEM
Key Attributes Physical Data
Clean Room
Hold-down clip (CHDC)
Clean Room
Clean Room Main Runner
Cross Tee
Board Tile
57
Specific Applications
PRELUDE 24 CORROSIVE RESISTANT
Exposed 24 mm grid system (nominal).
Special paint finish and TLX steel-based composite clip for enhanced corrosion resistance.
Corrosion resistance 700 hours salt spray test on grids according to EN ISO 9227 standards.
Durability Class C (EN13964:2004 + A1:2006)
Universal Main Runners 24 Corrosive Resistant Peakform and Superlock Clip (bulb to bulb connection)
Section Drawings
Main Runner 24 Corrosive Resistant
Length
Cross Tee TLX 24 Corrosive Resistant Cross Tee TLX 24 Corrosive Resistant
Length
Perimeter Solution
T 1924 LB
Corrosive
A CR1829 G A CR11 G resistant
A CR7890 G
1000mm Threaded rod Small hook suspension
Universal retaining clip
dia. 6 mm angle
58 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Specific Applications
PRELUDE 24 CORROSIVE RESISTANT
6 Tile Main Runner Hanger 1 Main Runner 2 Cross Tee 3 Cross Tee 4 Hanger 7 Universal
centres centres 1200 mm 600 mm Retaining Clip
1200 x 600 mm 1200 mm 1200 mm 0,84 lm 1,67 lm - 0,70 pcs 5,56 pcs
1,39 pcs
600 mm 1200 mm 1,67 lm - 0,84 lm 1,40 pcs 5,56 pcs
600 x 600 mm 1200 mm 1200 mm 0,84 lm 1,67 lm 0,84 lm 0,70 pcs 5,56 pcs
2,78 pcs
600 mm 1200 mm 1,67 lm - 1,67 lm 1,40 pcs 5,56 pcs
2
5 Perimeter Trim approx. 0,70 lm/m The chart is for general guidance only.
Hanger spacing
1) Values in the above table conform to Class 1 as defined in EN
Tile weight Main Runner spacing 1200 mm Main Runner spacing 600 mm
13964:2004+A1:2006 table 6.
1200 mm Cross Tee 600 mm Cross Tee
For other classes /deflection limits please contact your local Armstrong
14 30 32 14 20 32
Technical Sales team.
2,5 kg/m 2 1900 2100
2) Values are determined from laboratory tests methods in accordance with
3,0 kg/m 2 1800 2100 EN 13964:2004+A1:2006 clause 5.
3,5 kg/m 2
1750 2100 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum
4,0 kg/m 2
1700 2100 deflection of the grid is L/500 but not greater than 4 mm (L = span).
5,0 kg/m 2
1600 2000 4) No other applied loads such as luminaires, air diffusers, smoke
5,5 kg/m 2
1550 1950 detectors, sprinklers, hanging signs etc. are permitted.
6,0 kg/m 2
1500 1900 5) No overlays such as mineral wool or fibre glass quilts, as may be required for
7,0 kg/m 2
1450 1800 enhanced acoustic, fire or thermal performance, are permitted unless their full
weight is established and included, together with the weight of the tile, within
8,5 kg/m 2
1300 1700
the appropriate weight groups.
10,5 kg/m 2
1200 1600
6) For grid loading data calculated to different criteria than Class 1 to
13,0 kg/m 2
1050 1500 EN13964:2004+A1:2006, see the grid loading technical section on pages 20 - 21.
Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.
59
Specific Applications
SEISMIC Rx®SYSTEM
Exposed 24mm grid system (nominal).
Independently tested approach using Prelude XL2 grid to achieve ceiling installations that can withstand the forces
associated with significant seismic activity or other severe events.
Universal Main Runners Prelude 24 Peakform and Superlock Clip (bulb-to-bulb connection)
Accessories
60 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Specific Applications
SEISMIC Rx®SYSTEM
System Drawing
30 mm B
Unattached Wall
B
x x
B
Unattached Wall Detail
B
200mm MAX x x
20mm 600mm
30mm c/c
B
x x
Optional Screw
B B B
Unattached Wall
x Hanger Wire
Availability of products may vary according to location. Please contact Armstrong Technical Sales for further details.
61
Specific Applications
LONGSPA N SYSTEM
LongSpan Grids are designed to create a primary framework underneath beams or between walls, thereby
allowing the suspended ceiling Main Runners to be installed with fewer suspension points.
Primary Channels
Accessories
CC 4000 G
CA 120 G
CC 4000 G Channel 13 x 38 mm 38 20 26,50
CA 120 G Preformed channel clip** - 100 0,50
*Both Bent hanger for T profile and special holding clamp only work with threaded rod A 1829 G+ Connector A1839 G + nut (A 1827 G)
**Install one clip on each side of the Channel CC 4000 G
All measurements in millimetres. All sizes are nominal.
62 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Specific Applications
L O N G S PA N S Y S T E M
System Drawing
AR 45.....
Connector
AM 45....
Wall connector
Steel beam
CA 120 G
Preformed channel clip
CC 4000 G
Channel (tie bar)
1200
A 4510 G
Bent hanger for
T profile
1200
LP...
Primary channel
Note :
- Two wall connectors AM 45... must be
used to fix to walls.
- Two connectors AR 45... must be used
when connecting two lengths of Primary
Channel together.
- Two preformed channel clips CA 120 G
must be installed on the opposites sides of AB 11...
the Primary channel Special holding clamp
63
Perimeter Solutions
FLEXIBLE PERIMETER TRIMS
Excellent solution for finishing ceilings around columns and convex walls, easily cut and curved by
hand on site.
Perimeter Trims
White
FT 2424 2500 24 10 25,00 5,50 50
FT 1929 2500 29 10 25,00 5,50 50
24 mm
29 mm
Black
FT 2424 BK 2500 24 10 25,00 5,50 50
FT 1929 BK 2500 29 10 25,00 5,50 50
19 mm
Accessory
• Colour
Available in Global White and Black.
64 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Perimeter Solutions
FLEXIBLE PERIMETER TRIMS
Perimeter Detailing
50 mm 50 mm
3 These trims are considered decorative elements therefore any grid laying on them will need :
Note:
These trims can be used only in curved TOE OUT ( Convex ) installations (19 x 29 section must be installed with the 29 mm
face vertical).
Minimum bending radius : 200 mm.
Minimum environment temperature during the curving operation : 20ºC.
Due to the nature of the PVC coating, these trims do not exactly match our standard black & white colour and gloss.
Fire reaction classification Euroclass F (EN 13501-1) - please check local/country regulations for compliance.
65
Mineral Perimeter Solutions
PERIMETER SOLUTIONS
A comprehensive range of the most commonly used perimeter profiles, including shadowline, F upstands and
cover plates, finished to match all Prelude 24 mm and 15 mm, Bandraster and Prelude 35 grid systems.
T 2401 H Perimeter angle, painted heavy duty 3050 0,70 30 91,50 22,00
T 2400 H Perimeter angle, painted 3050 0,60 30 91,50 20,00
intermediate duty
T 2424 HC Perimeter angle, painted 3050 0,45 36 109,80 21,60
30
All products standard in Global White. Other standard colours available for item numbers with index (1). See details below.
(1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE),
White RAL 9010 (WR), Opal (OL), Brown (BN), Ivory (IY), Blue (BE), Red (RD), Green (GN).
All measurements in millimetres. All sizes are nominal.
66 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Mineral Perimeter Solutions
PERIMETER SOLUTIONS
Mineral suspension system.
Perimeter Trims
Perimeter Detailing
24 40
00
00 .3
.3 ca
19 ca 1
20
Standard perimeter finish with perimeter angle Perimeter finish with C channel T 2040 HA
T 1924 HD or T 1924 CA
1 A 7890 G Universal retaining clip
25 32
00
.3 00
6 ca .3
15 7,5 ca
15 15
Perimeter finish with shadowline T 1506 H Perimeter finish with unequal U-Profile T 1575 HA
67
Metal Perimeter Solutions
PERIMETER SOLUTIONS
Metal suspension system.
68 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Metal Perimeter Solutions
PERIMETER SOLUTIONS
Metal suspension system.
25
20
10
M 311081
15 25
40
C 1803 H
20
T 2040 H WR A
Perimeter channel and perimeter wedge for cut modules
69
Accessories
ACCESSORIES
Item Nr. Description Dimensions Content / Carton Weight / Carton Admissible Load *
length (mm) pcs kg kg
A WDN20 H Bent tee bar hanger for threaded rod 57 100 1,40
20
(tested with
A 14 G Universal clip 40 100 1,00 6 mm
threaded rod)
* Note: These admissible loads have been determined from laboratory tests in accordance with EN 13964 : 2004 + A1 : 2006 and apply
to the hangers and their grid connections only.
No account has been taken of the strength of top fixings which must be selected as appropriate for the supporting structure and
estimated load.
70 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
Accessories
ACCESSORIES
Suspension & Accessories
Item Nr. Description Dimensions Content / Carton Weight / Carton Admissible Load *
length (mm) pcs kg kg
33
190
A 10230 G Bottom part of nonius hanger 190 100 4,30
* Note: These admissible loads have been determined from laboratory tests in accordance with EN 13964 : 2004 and apply to the hangers and their grid connections only.
No account has been taken of the strength of top fixings which must be selected as appropriate for the supporting structure and estimated load.
71
Accessories
ACCESSORIES
Suspension & Hold Down Clips
A 1829
10
82
148
18
A 1822 G Clip for quick hanger 1,6 - 4,8 mm thickness - 100 0,80
A 1823 G Clip for quick hanger 4,8 - 9,5 mm thickness - 100 3,00
38
55
A 7890 G Universal retaining clip - 100 0,40
38
A 819 G Locking hold down clip, for 6 - 30mm tiles 64 500 2,40
(Peakform & Square bulb)
72 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
ACCESSORIES
Accessories
Hold Down Clips & Accessories
66
A 7912 G Hold down clip for 40 mm soft 68 100 1,10
22
fibre panels
12 16
8
24
4 MCC4 G Mitre closure clip for - 200 0,30
6 mm Silhouette & Microline
38
LFC G Peakform Corner support of lay-in light - 50 0,45
(Silhouette & Microline 15 mm grid)
A 131 G T bar saddle clip (Peakform & Square bulb) 98 100 2,70
Perimeter Accessories
13
6 24
A 0324 G Tegular border clip 29 500 1,20
o
75
29
15
6,5
6 24
74 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie
UK Colour Info_Layout 1 15/11/2012 10:39 Page 3
www.armstrong-ceilings.co.uk
www.armstrong-ceilings.ie
WESTERN EUROPE Spain
Armstrong Building Products
United Kingdom
Armstrong World Industries Ltd
CENTRAL
Belgium & Luxembourg
Armstrong Building Products B.V.
Oficina de ventas España
Immeuble Paryseine
Building Products Division
Armstrong House
EUROPE NORTH
Bureaux Commerciaux Belgique 3 Allée de la Seine 38 Market Square (DK/EE/FIN/IS/LT/LV/N/PL/S)
Postbus 3803 94854 Ivry-sur-Seine uxbridge UB8 1NG Armstrong Building Products BV
4800 DV Breda Francia Tel.: 0800 371849 Sp. z o.o. Oddział w Polsce
Nederland Tel.: (+ 34) 91 642 04 99 Fax: (+44) 1895 274287 ul. Domaniewska 37
Tel.: (+32) 02 223 00 72 00 800 90 21 03 68 e-mail: sales-support@armstrong.com 02-672 Warszawa
Fax: (+31) 076 521 04 07 Fax: (+33) 1 4521 04 11 www.armstrong-ceilings.co.uk Poland
e-mail: benelux-info@armstrong.com e-mail: info-espana@armstrong.com Tel.: (+48) 0 22 337 86 10/ 86 11
www.armstrong-plafonds.be www.armstrong.es/techos Republic of Ireland Fax: (+48) 0 22 337 86 12
Armstrong World Industries Ltd. e-mail: service-ce@armstrong.com
Germany & Switzerland Portugal 108 Greenlea Road Latvia: www.armstrong.lv
Armstrong Building Products Armstrong Floor Product Terenure Lithuania: www.armstrong.lt
Kundenservice Rua de Manuel Assunçao de Falcao, 63 Co Dublin 6W Norway: www.armstrong.no
Office Building Quadrium 4475-041 Santa Maria de Avioso - Maia Ireland Poland: www.armstrong.pl
Claudius Prinsenlaan 126 Portugal Tel.: 1800 409002 Sweden: www.armstrong.se
4818 CP Breda Tel.: (+351) 22 982 81 10 Tel.: (+353) 1 499 1701
Niederlande Fax: (+351) 22 982 81 19 Fax: (+353) 1 490 7061
Tel.: (+49) 0251 7603 210 e-mail: service_portugal@armstrong.com e mail: sales-support@armstrong.com CENTRAL
Fax: (+49) 0251 7603 593
e-mail: deutsche-info@armstrong.com
www.armstrong.pt www.armstrong-ceilings.ie
EUROPE SOUTH
www.armstrong-decken.de France & French Speaking Africa (AL/BA/BG/CZ/HR/HU/KO/
www.armstrong-decken.at Armstrong Building Products SAS MIDDLE EAST / MD/ME/MK/RO/RS/SK/SI)
Armstrong Building Products
www.armstrong.ch Bureaux Commerciaux France
Immeuble Paryseine AFRICA / TURKEY Lighthouse Building,
Armstrong Metalldecken AG 3 Allée de la Seine Armstrong World Industries Ltd Jankovcova 1569/2c,
Breitfeldstrasse 8 94854 Ivry-sur-seine Africa Middle East Turkey Division 170 00 Praha 7,
9015 st. Gallen Tel.: 0800 41 36 43 Armstrong House Czech Republic
Switzerland Fax: (+33) 1 45 21 04 11 38 Market Square Tel. : +420 234 700 543
Tel.: +41 (0) 71 313 63 63 e-mail: info-france@armstrong.com Uxbridge UB8 1NG e-mail: service-ce@armstrong.com
Fax: +41 (0) 71 313 64 00 www.armstrong.fr/plafonds Tel.: (+44) 01895 251122 Czech republic: www.armstrong.cz
Fax: (+44) 01895 272928 Hungary: www.armstrong.co.hu
Zentralschweiz Siège social e-mail: sales-support@armstrong.com Romania: www.armstrong.ro
Armstrong Metalldecken AG Armstrong Building Products SAS www.armstrong.eu Serbia: www.armstrong.rs
Buro / Lager Zentralschweiz 67 Rue de Salins Israël: www.armstrong.co.il Slovakia: www.armstrong.sk
Grossweid 9 Bp 89 South Africa: www.armstrong-ceilings.co.za Slovenia: www.armstrong.si
CH-6026 rain 25300 Pontarlier
Tel.: +41 (0) 41 921 63 63 France Dubai | United Arab Emirates
Fax: +41 (0) 41 921 63 80 Armstrong World Industries JLT EASTERN EUROPE
Italy & Greece Office No. 2003, 20th Floor CIS
Suisse Romande Armstrong Building Products Gold Crest Executive Tower Armstrong Moscow GmbH
Armstrong Plafonds Métalliques SA Ufficio Commerciale Italia Jumeirah Lakes Towers Park Place, office E502
Bureau Suisse Romande Immeuble Paryseine P.O. Box 73831 # 113/1, Leninsky Prospekt
3, Rue Gustave-Monynier 3 Allée de la Seine Dubai, U.A.E. Moscow 117198
CH-1202 Genève 94854 Ivry-sur-Seine info-me@armstrong.com Russia
Tel.: +41 (0) 22 731 60 70 Francia www.armstrong.ae Tel.: (+7) 495 956 5100
Fax: +41 (0) 22 731 60 74 Tel.: (+39) 02 66 22 76 50 Fax: (+7) 495 956 5101
Fax: (+39) 02 66 20 14 27 Turkiye e-mail: info-cis@armstrong.com
Austria/Eastern Europe e-mail: info-italia@armstrong.com Armstrong Europa GmbH Russian Federation: www.armstrong.ru
Armstrong Metalldecken GmbH www.armstrong-soffitti.it Turkiye Satış Temsilciliği
Bundesstrasse 70 Sarıyer-Istanbul
A-6830 Rankweil Netherlands Turkiye
Tel.: +43 (0) 55 22 34 44-0 Armstrong Building Products B.V. Gsm: +90 533 367 54 89
Fax: +43 (0) 55 22 34 44-8 Verkoopkantoor Nederland Fax: +90 212 257 44 78
Postbus 3803 www.armstrong.com.tr
Armstrong Metalldecken GmbH 4800 DV Breda cbalci@armstrong.com
Messendorferstrasse 6 Nederland
A-8041 Graz Tel.: (+31) 076 52 30 200
Tel.: +43 (0) 31 64 71 584 Fax: (+31) 076 521 04 07
Fax: +43 (0) 31 64 71 584-10 e-mail: benelux-info@armstrong.com
www.armstrong.nl/plafonds
Advisory note
All photographic and design elements supplied in this brochure do not necessarily reflect any recommendation by any of the companies named in this brochure
as to the proper use or recommended methods of installation of suspended ceilings and are supplied only as informative material. For technical reasons in
printing, differences may appear between colours printed in this brochure and the actual product. The choice of colours should always be made from a sample
of the product. All statements and technical information contained in this brochure, or any publication of the companies named in this brochure, relating to
Armstrong ceilings are based on results obtained under laboratory test conditions. It is the responsibility of the user to verify with the seller of the products in
writing that such statements and information are appropriate to the specific use intended. Sales of the products and liability of the selling companies are in
accordance with the terms and conditions of sale of the selling company. All product specifications are subject to modifications without prior notice.