The Mechanical Is The Power Input To The Pump Shaft or On Other Words Power Output From

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 3

The single pump receives its water directly from the sump.

The sump drain outlet is


located next to the built-in bench pump. A hose should extend between the sump and
the auxiliary pump. The hose is attached to both the sump outlet and the auxiliary
pump inlet. Next, a hose continues from the auxiliary pump to the manifold. Make
sure manifold outlet drains down into hydraulic bench for water collection. Figure 1
shows the proper piping connections.

The mechanical power (pi or Nm) = 2Tw in [W]


𝜋
Where T is torque and w = 30 𝑓 and 𝑓 will be at 3000 rpm
The mechanical is the power input to the pump shaft or on other words power output from
the motor.

For hydraulic power Po(Nh) = *Q*Hp = [N/m3] *[m3/s] *[m] = [N-m/s] = [J/s] = [W]
Where

Hp or (Ht) is total head, Q is Flow rate and  ‫كتبها مزون مااندلو اسمها‬

Hydraulic power Po(Nh) is the power out from the pump or power imparted to the fluid.

Total Head: HP = (pressure head at pump 2 outlet - pressure head at pump 1 inlet)/

For a pump, the efficiency is defined as


 = Po(Nh)/Pi(Nm)