Professional Documents
Culture Documents
Darcy Friction Loss Calculator For Pipes, Fittings & Valves: Given Data
Darcy Friction Loss Calculator For Pipes, Fittings & Valves: Given Data
Darcy Friction Loss Calculator For Pipes, Fittings & Valves: Given Data
Given Data
Flow Rate (Q) m3/hr 21.4 0.00594 m3/s INPUTS
Pipe Inside Diameter (D) mm 29.5 0.0295 m CALCULATED VALUES
Kinematic Viscosity (ν) cSt 8.6 8.600E-06 m2/s
Specific Roughness (Є) m 1.50E-05
Pipe Length (L) m 16.6
Calculated Data
Average Velocity - V (m/s) 8.70
Reynolds Number 29833
Darcy Friction Factor 0.025
Head Loss - Pipe (m) 53.98 TOTAL HEAD LOSS, hf (m) 74.80