Ejercicio 3

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 5

3. A series piping system consists of 15 mi of NPS 20, 0.250 in.

wall thickness, connected


to 10 mi of NPS 16, 0.250 in. wall thickness, 20 mi of NPS 14, 0.250 in. wall thickness and
10 miles of NPS 12, 0.250 in. wall thickness pipes. Calculate the inlet pressure required at
the beginning A for a gas flow rate of 85 MMSCFD. Gas is delivered to the terminus B at a
delivery pressure of 600 psig. The gas gravity and viscosity are 0.6 and 0.000008 lb/ft-s,
respectively. The gas temperature is assumed constant at 60°F.

Use a compressibility factor of 0.85 and the General flow equation with Colebrook friction
factor. The base temperature and base pressure are 60°F and 14.7 psia, respectively.

DATOS:

# Long (mi) Dext (NPS) Espesor Pared (in) Dint


AC 15 20 0,25 19,5
CD 10 16 0,25 15,5
DE 20 14 0,25 13,5
EB 10 12 0,25 11,5

Datos conocidos
Datos calculados

Caudal
GE Viscosidad Presión en B (psig)
(MMSCFD)
85 0,6 0,00008 600
T Base P Base Z
60F 14,7 Psia 0,85

A C D E B

600 psig

85 MMSCFD

Se iniciaron los cálculos por segmentos, BE, ED, DC, CA

SEGMENTO BE:

CALCULAMOS EL Re:
𝑃𝑏 𝐺𝑄 Pb pisa
𝑅𝑒 = 0.0004778 ∗ 𝑇𝑏 ∗ µ∗𝐷𝑖𝑛𝑡
Tb R

Q 𝐹𝑡 3
T Base P Base Dint 𝐷𝑖𝑎
60F 14,7 Psia 11.5
Dint In

µ 𝑙𝑏
Re = 7,487.597 𝑓𝑡 − 𝑠

Con la ecuación de Coolebrok (1) hallamos el factor de


transmisión:

Se asumió Acero comercial en el material del gasoducto, Rugosidad absoluta=


0.00018 in.

Primero asumimos un valor de f (como 0.01) y sustituimos en el lado derecho


de la ecuación. Esto producirá una segunda aproximación para f, que luego se
puede usar para calcular un mejor valor de f, y así sucesivamente. Así, f da
como resultado:

f= 0.009552

Luego, el factor de transmisión se halla con la formula (2):


2
𝐹= 2
√𝑓

F= 20.463

Ya con esto, con la formula general (3) Hallamos la Presión en E (𝑃1 )


3

# Long (mi)
BE 10

Despejando 𝑃1 tenemos:
2
0.5
𝑄 ∗ (𝐺𝑇𝑓 𝐿𝑍)
𝑃1 = √ ( ) + 𝑃2 2
𝑇𝑏
𝐷𝑖𝑛𝑡 2.5 ∗ 38.77 ∗ 𝐹 ∗ ( ) 4
𝑃𝑏

𝑃1 = 𝑃𝐸 706.265 psia = 691.565 psig

Seguimos con el segmento ED


𝑃𝑏 𝐺𝑄
𝑅𝑒 = 0.0004778 ∗ 𝑇𝑏 ∗ µ∗𝐷𝑖𝑛𝑡

T Base P Base Dint


60F 14,7 Psia 13.5

Re= 6,378.323

Con la ecuación de Coolebrok (1) hallamos el factor de friccion:

f= 0.009547

Luego, el factor de transmisión se halla con la formula (2):

F= 20.4696
Ya con esto, con la formula general (3) Hallamos la Presión en E (𝑃1 )

# Long (mi)
ED 20

Con la ecuación (4), hallamos P1, siendo = 𝑃2 = 𝑃𝐸

𝑃1 = 𝑃𝐷 = 779.263 psia = 764.563 psig

Seguimos con el segmento DC

T Base P Base Dint


60F 14,7 Psia 15.5

CALCULAMOS EL Re:

𝑃𝑏 𝐺𝑄
𝑅𝑒 = 0.0004778 ∗ 𝑇𝑏 ∗ µ∗𝐷𝑖𝑛𝑡

Re = 5,555.314

Con la ecuación de Coolebrok (1) hallamos el factor de friccion:

f= 0.009573

Luego, el factor de transmisión se halla con la formula (2):

F= 20.4414

Ya con esto, con la formula general (3) Hallamos la Presión en E (𝑃1 )


# Long (mi)
DC 10

Con la ecuación (4), hallamos P1, siendo = 𝑃2 = 𝑃𝐷

𝑃1 = 𝑃𝐶 = 796.555 psia = 781.855 psig


Seguimos con el segmento CA

T Base P Base Dint


60F 14,7 Psia 19.5

CALCULAMOS EL Re:

𝑃𝑏 𝐺𝑄
𝑅𝑒 = 0.0004778 ∗ 𝑇𝑏 ∗ µ∗𝐷𝑖𝑛𝑡

Re = 4,415.762

Con la ecuación de Coolebrok (1) hallamos el factor de friccion:

f= 0.009678

Luego, el factor de transmisión se halla con la formula (2):

F= 20.3295

Ya con esto, con la formula general (3) Hallamos la Presión en E (𝑃1 )


# Long (mi)
CA 15

Con la ecuación (4), hallamos P1, siendo 𝑃2 = 𝑃𝐶

𝑃1 = 𝑃𝐴 = 804.739 psia = 790.039 psig

# Long (mi) Dext (NPS) Espesor Pared (in) Dint P(Psig)

A 15 20 0,25 19,5 790.039


C 10 16 0,25 15,5 781.855

D 20 14 0,25 13,5 691.565

B 10 12 0,25 11,5 600

La presión requerida en la entrada A es de: 790.039 psig