According to ASME Code, Sec. VIII, Div. 1, Edition 2001, Addenda 2002 / TEMA "R" 7th Edition 88. Sheet : 1 of 6
Designed by : Eng. Abdel Halim Galala, Design General Manager (Assistant) Rev. : 0
Project : Design & Fabrication of Heat Exchanger for APRC Refinery Date : 4.7.2003
Job No. : 7443-33 Location : Alex.
Dwg. No. : 7443-33-1A, Rev. 0 Sheet : 14 Client : APRC
Exchanger : Residue Cooler, Type : AES, TEMA class : R Item : E-323A/B & E-514C/D
P. Flat Unstayed Circular Blind Flange(Channel Cover) Thickness (item no. 22) [UG-34 & Fig. UG-34 Sketch (j)]
[Attached by Bolts] Subjected to internal pressure
Blind Cover Material, Clad Metal : SB171 UNS No. C63000 ASME SA266 Class 2
Stud bolt material SA 193 Grade B7
o o
Design Temperature 140 F 60 C
o o
Min. Design Metal Temperature, MDMT 53.6 F 12 C
o o
Bolt-up and Gasket Seating Temperature 86 F 30 C
Assume corrosion allowance, C [UG-25] 0.19685 INCH 5 MM
Operating Pressure (tube side) 56.8182 PSIG 4 Kg/CM2G
Internal Design Pressure, P (MAWP) 71.7082 PSIG 5.04826 Kg/CM2G
Allowable Stress of Bolt Material, SB :
* at design temp.(operating condition), Sb 25000 PSIG 1760 Kg/CM2G
* or at atmospheric temp./bolt-up temp. (gasket seating), Sa 25000 PSIG 1760 Kg/CM2G
Allowable Stress of Flange Material :
* at design temp.(operating condition), SfH 20000 PSIG 1408 Kg/CM2G
* or at atmospheric temp./bolt-up temp. (gasket seating), SfC 20000 PSIG 1408 Kg/CM2G
[Table 1A , SubPart 1 , ASME Sec. II , Part D]
Joint efficiency, E 1
Figure (5)
No. of bolts 28
Nominal bolt dia., dB 1 INCH 25.4 MM
Actual cross-sectional area of each bolt, [TEMA Table D-5] 0.551 INCH2 355.4832 MM2
2
Total actual cross-sectional area of bolts, Ab 15.428 INCH 9953.528 MM2
Flange face outer diameter 22.1654 INCH 563 MM
Flange face inner diameter 19 INCH 482.6 MM
DESIGN CALCULATIONS OF HEAT EXCHANGER Page : 77 of 136
According to ASME Code, Sec. VIII, Div. 1, Edition 2001, Addenda 2002 / TEMA "R" 7th Edition 88. Sheet : 2 of 6
Designed by : Eng. Abdel Halim Galala, Design General Manager (Assistant) Rev. : 0
Project : Design & Fabrication of Heat Exchanger for APRC Refinery Date : 4.7.2003
Job No. : 7443-33 Location : Alex.
Dwg. No. : 7443-33-1A, Rev. 0 Sheet : 14 Client : APRC
Exchanger : Residue Cooler, Type : AES, TEMA class : R Item : E-323A/B & E-514C/D
P. Flat Unstayed Circular Blind Flange (Channel Cover) Thickness (item no. 22) (cont.)
[Attached by Bolts] [UG-34 & Fig. UG-34 Sketch (j)]
Gasket Details: - Flat metal, jacketed asbestos filled, soft copp[er or brass 0.125 INCH 3.175 MM
- Outside diameter 22.0472 INCH 560 MM
- Inside diameter = O.D - 2N 20.8661 INCH 530 MM
- Width, N 0.59055 INCH 15 MM
Gasket Dimensions:
Basic gasket seating width, bO = N/2 [Table 2-5.2] 0.29528 INCH 7.5 MM
Since bo > 1/4 ", Effective gasket seating width, b = 0.5 SQRT(bO) [Table 0.2717 INCH 6.901087 MM
Gasket Factor, m [Table 2-5.1] 3.5
Min. Seating Stress, y [Table 2-5.1] 6500 PSIG 457.6 Kg/CM2G
Facing Sketch [Table 2-5.1] (1a); Column II
Factor depending upon method of attachment of head, C [Fig. UG-34, Sketch (j)] 0.3
Gasket moment arm, hG = (B.C.D - d)/2 = (C-G)/2 [Table 2-5.2] 1.51185 INCH 38.40109 MM
SA 193 Grade B7
o
F 100 140 150
PSI 25000 ? 25000
ASME SA266 Class 2
o
F 100 140 200
PSI 20000 ? 20000
DESIGN CALCULATIONS OF HEAT EXCHANGER Page : 78 of 136
According to ASME Code, Sec. VIII, Div. 1, Edition 2001, Addenda 2002 / TEMA "R" 7th Edition 88. Sheet : 3 of 6
Designed by : Eng. Abdel Halim Galala, Design General Manager (Assistant) Rev. : 0
Project : Design & Fabrication of Heat Exchanger for APRC Refinery Date : 4.7.2003
Job No. : 7443-33 Location : Alex.
Dwg. No. : 7443-33-1A, Rev. 0 Sheet : 14 Client : APRC
Exchanger : Residue Cooler, Type : AES, TEMA class : R Item : E-323A/B & E-514C/D
P. Flat Unstayed Circular Blind Flange (Channel Cover) Thickness (item no. 22) (cont.)
[Attached by Bolts] [UG-34 & Fig. UG-34 Sketch (j)]
Required bolt load under atmospheric temp.conditions, Wm2 = 3.14bGy (2) 119246 lb 54089.04 Kg
Total required cross-sectional area of bolts, Am = Max (Am1,Am2) 4.76983 INCH2 3077.304 MM2
N.B. Check which the deflection is considered a governing thickness or not. 2.48031 INCH 63 MM
The deflection is ehe governing thickness
DESIGN CALCULATIONS OF HEAT EXCHANGER Page : 79 of 136
According to ASME Code, Sec. VIII, Div. 1, Edition 2001, Addenda 2002 / TEMA "R" 7th Edition 88. Sheet : 4 of 6
Designed by : Eng. Abdel Halim Galala, Design General Manager (Assistant) Rev. : 0
Project : Design & Fabrication of Heat Exchanger for APRC Refinery Date : 4.7.2003
Job No. : 7443-33 Location : Alex.
Dwg. No. : 7443-33-1A, Rev. 0 Sheet : 14 Client : APRC
Exchanger : Residue Cooler, Type : AES, TEMA class : R Item : E-323A/B & E-514C/D
P. Flat Unstayed Circular Blind Flange (Channel Cover) Thickness (item no. 22) (cont.)
[Attached by Bolts] [UG-34 & Fig. UG-34 Sketch (j)]
CONCLUSION:
FLANGE SUMMARY
Flange thickness (without C.A.) 1.29857 INCH 32.98372 MM
Use t for construction including R.F. 2.04724 INCH 52 MM
For a proper design of flange :
1. You have to make a check for flange deflection.
GASKET SUMMARY
Gasket width, N 0.59055 INCH 15 MM
Required cross-sectional of bolts, Am 4.76983 INCH2 3077.304 MM2
Actual cross-sectional area of bolts, Ab 15.428 INCH2 9953.528 MM2
BOLT SUMMARY
No. of bolts 28 Bolt
Size of bolt (the bolt size is represented by its actual cross-sectional area) 1 INCH 25.4 MM
Bolt hole dia. 1.125 INCH 28.575 MM
Total required cross-sectional area of bolts, Am 4.76983 INCH2 3077.304 MM2
Total actual cross-sectional area of bolts, Ab 15.428 INCH2 9953.528 MM2
Actual cross-sectional area of bolt, [TEMA TABLE D-5] 0.551 INCH2 355.4832 MM2
Since the actual bolt area Ab > The required bolt area Am,
the bolts are adequately enough.
Project : Design & Fabrication of Heat Exchanger for APRC Refinery Date : 4.7.2003
Job No. : 7443-33 Location : Alex.
Dwg. No. : 7443-33-1A, Rev. 0 Sheet : 14 Client : APRC
Exchanger : Residue Cooler, Type : AES, TEMA class : R Item : E-323A/B & E-514C/D
P. Flat Unstayed Circular Blind Flange (Channel Cover) Thickness (item no. 22) (cont.)
[Attached by Bolts] [UG-34 & Fig. UG-34 Sketch (j)]
Actual Bolt spacing, B (c/c) from drawing 2.74622 INCH 69.75387 MM
Min. Bolt spacing, B (for bolt size 0.75") 1.75 INCH 44.45 MM
Min. Bolt spacing, B (for bolt size 7/8") [TEMA Table D-5] 2.0625 INCH 52.3875 MM
Min. Bolt spacing, B (for bolt size 1") 2.25 INCH 57.15 MM
Min. Bolt spacing, B (for bolt size 1-1/8") 2.5 INCH 63.5 MM
Min. Bolt spacing, B (for bolt size 1-1/4") 2.8125 INCH 71.4375 MM
Max. Recommended bolt spacing, Bmax = 2 dB + 6 t / (m + 0.5) [TEMA RCB 3.94882 INCH 100.3 MM
Check for Flat Channel Cover Deflection [TEMA RCB-9.21]
The effective thickness of a flat channel cover shall be the thickness at the
bottom of the pass partition groove (or the face if there is no groove) minus
corrosion allowance in excess of groove depth. The thickness is to be at
least that required by the appropriate Code formula and thicker if required
to meet proper deflection criteria.
The recommended limit for channel cover deflection is:
0.03" for nominal diameters thru 24" 0.03 INCH 0.762 MM
0.125% of nominal diameters (nominal diameter/800) for larger sizes 0.025 INCH 0.635 MM
Nominal diameter = Shell ID + 2 ts 20 INCH 508 MM
A method for calculating of channel cover deflection at the center, Y is:
G
Y =
ET 3
(
0.0435G 3 P+0.5S B A B h G )
Where G = Gasket load reaction diameter as defined by the Code 21.5039 INCH 546.1978 MM
2
E = Modulus of elasticity at design temperature [ASME Sec.II,Part D, TM-31460000 PSI 2214784.07 Kg/CM G
T = Thickness under consideration (minus groove and C.A.) 1.29921 INCH 33 MM
P = Design pressure 71.7082 PSIG 5.04826 Kg/CM2G
SB = Allowable bolting stress at design temperature (Wm1) 25000 PSIG 25000 Kg/CM2G
AB =Actual total cross-sectional root area of bolts 15.428 INCH2 9953.528 MM2
hG = Radial distance from diameter G to bolt circle 1.51185 INCH 38.40109 MM
Project : Design & Fabrication of Heat Exchanger for APRC Refinery Date : 4.7.2003
Job No. : 7443-33 Location : Alex.
Dwg. No. : 7443-33-1A, Rev. 0 Sheet : 14 Client : APRC
Exchanger : Residue Cooler, Type : AES, TEMA class : R Item : E-323A/B & E-514C/D
P. Flat Unstayed Circular Blind Flange (Channel Cover) Thickness (item no. 22) (cont.)
[Attached by Bolts] [UG-34 & Fig. UG-34 Sketch (j)]
G
The calculated deflection is Y =
E T3
(0.0435 G 3
P + 0.5 S B AB hG ) 0.10054 INCH 2.553795 MM
G
Y =
E T3
(
0.0435 G 3 P + 0.5 S B AB hG ) 0.00914 INCH 0.232149 MM
Easier approach :
1. Assume T, 1.88283 INCH 47.824 MM
G
2. Find Calculated deflection Y =
E T3
(
0.0435 G 3 P + 0.5 S B AB hG ) 0.03303 INCH 0.839054 MM
The minimum thickness of channel cover at bottom of pass partition is 1.88283 INCH 47.824 MM
The thickness neglecting corrosion allowance is 1.88976 INCH 48 MM