Professional Documents
Culture Documents
Detail Calculation A. Calculation of Ballast Tank Volume
Detail Calculation A. Calculation of Ballast Tank Volume
Doc. No.
BL
DETAIL
CALCULATION OF Rev. No. 1
BALLAST SYSTEM
Page 1 of 2
DETAIL CALCULATION
a. Calculation of ballast tank volume
Volume of ballast tank has been calculated on general arrangement
Total Volume = 1742.255 m3
So, the required internal pipe diameter for ballast ballast pipe is
d= 0.131 m
d= 130.9 mm
From requirement above, so the specification pipe that choosen is :
Standard = DIN2440
Outside Diameter = 166.5 mm
Thickness = 4.85 mm
Inside Diameter = 156.8 mm
Schedule = 40
04 - 42 18 DN02 –
Doc. No.
BL
DETAIL
CALCULATION OF Rev. No. 1
BALLAST SYSTEM
Page 1 of 2
HL mayor = f x L x V2 / (D x 2g)
Where,
f = 0.127
L = 120 m
04 - 42 18 DN02 –
Doc. No.
BL
DETAIL
CALCULATION OF Rev. No. 1
BALLAST SYSTEM
Page 1 of 2
V = 3 m/s
D = 156.8 mm
g = 9.810 m/s2
So,
HL major = 44.584348 m
D = 156.8 mm
g = 9.810 m/s2
So,
HL major = 4.46 m