Professional Documents
Culture Documents
Osnove Ex Zastite 2012 PDF
Osnove Ex Zastite 2012 PDF
Osnove Ex Zastite 2012 PDF
450°C
300°C
površine
200°C
135°C
100°C
85°C
Temp. klasa T1 T2 T3 T4 T5 T6
I metan
Skupine plinova
2G Gb
Oklapanje HRN/EN/IEC 60079-1 d 1
M2 Mb
Povećana 2G Gb
HRN/EN/IEC 60079-7 e 1
sigurnost M2 Db
px 2G, M2 Gb, Db 1
Nadtlak HRN/EN/IEC 60079-2 py 2G, M2 Gb, Db, 1
pz 3G Gc 2
nA
nC
Vrsta zaštite “n” HRN/EN/IEC 60079-15 3G Gc 2
nL
nR
2G Gb
Punjenje HRN/EN/IEC 60079-5 q 1
M2 Db
2G Gb
Uranjanje HRN/EN/IEC 60079-6 o 1
M2 Db
tD
Zaštita kućištem HRN/EN/IEC 60079-31 1D, 2D, 3D Da, Db, Dc 20, 21, 22
ta, tb, tc
Samosigurnost HRN/EN/IEC 61241-11 iaD, ibD 1D, 2D, 3D Da, Db, Dc 20, 21, 22
maD
Oblaganje HRN/EN/IEC 60079-18 1D, 2D, 3D Da, Db, Dc 20, 21, 22
mbD
3G 2
Ograničeni dotok HRN/EN 13463-2 fr /
3D 22
2G, 2D
Oklapanje HRN/EN 13463-3 d / 1,21
M2
1G, 2G, 3G
Konstrukcijska 0, 1, 2
HRN/EN 13463-5 c 1D, 2D, 3D, /
sigurnost 20, 21, 22
M2
1G, 2G, 3G
Kontrola 0, 1, 2
HRN/EN 13463-6 b 1D, 2D, 3D, /
uzročnika paljenja 20, 21, 22
M2
1G, 2G, 3G
0, 1, 2
Uranjanje HRN/EN 13463-8 k 1D, 2D, 3D, /
20, 21, 22
M1, M2
2G, 2D 1, 21
Nadtlak HRN/EN/IEC 60079-2 p /
3G, 3D 2, 22
www.tepex.hr
OSNOVE PROTUEKSPLOZIJSKE ZAŠTITE
Ex oznaka uređaja
Označavanje Ex uređaja
No. Opis
1 7 1 Naziv i adresa proizvođača
2 Identifikacija proizvoda
HR - 10090 Zagreb
3 Tehnički podaci
2 GGCD 01/K1 3 230V 50Hz 50mA E-1/08 8
4 Znak protueksplozijske zaštite
9
4 II 2G 5 Ex de[ib]mb IIC T5 Gb IP66 5 Oznaka područja, kategorije i primjenjene vrste Ex
zaštite
HREx T 10.024 10 MA ....... 2 DATUM ......
6 Natpis upozorenja
6 UPOZORENJE - NE OTVARAJ POD NAPONOM
WARNING - DO NOT OPEN WHEN ENERGIZED 7 Oznaka sukladnosti (NN 46/08) , u EU oznaka
8 Oznaka certifikacijskog tijela
9 Temperatura okoliša ako nije standardna (-20 ÷ +40°C)
10 Broj tipnog certifikata i proizvodni broj