NOTES:

POWER SUPPLY MODULE CONNECTOR J1 AND PS INTERFACE PWB CONNECTOR J1 ARE BLIND-MATE CONNECTIONS.

J1 J1 W14P1
FROM AC/DC E1 E1
VAC (3-2B3) 47 L1 5 FAN VOLTS (A) + 6 FAN V SAMPLE (B)
POWER STAGE TO CONTROL/
SHEET 1 VAC (3-3B3) 46 L2/NEUTRAL 6
J8 MONITOR STAGE
45 GND/EARTH 7 SHEET 1
8 5 FAN V SAMPLE (A)
PART OF +VE
9
A8 U7 10
C1
0.001
C3
0.1 PART OF
PS INTERFACE PWB POWER SUPPLY
FAN A MODULE 11 A7
FAN A 12 POWER SUPPLY
DISTRIBUTION
PART OF +VE SENSE 22 PWB
A7 V CTRL INH 13
E2
POWER SUPPLY P16
DISTRIBUTION TP1 TP2 14 PART OF 1 FAN VOLTS (MODULES 1 TO 4) +
PWB 15 2 FAN VOLTS (MODULES 1 TO 4) + TO RF
W14P1 J8 J12 W23P1 W23P2 J2 A8 J1 POWER STAGE
FAN VOLTS CONTROL + 13 1 FAN VOLTS CONTROL (A) + 1 23 V_PGM 16 PS INTERFACE PWB 3 GND SHEET 1
-VE
FAN VOLTS CONTROL - 14 2 FAN VOLTS CONTROL (A) - 2 17 FAN A 4 GND
18
# FAN PS INHIBIT (A) + 11 3 # FAN PS INHIBIT (A) + 3 27 REMOTE ON/ENABLE 19
C4 C5 MP AC TMP FAIL 1
GND 12 8 GND 8 0.001 0.1 20 TP4 TP5 TP6 TP3 2
J2
-VE SENSE 24 3
J2 W23P2 W23P1
PS PRESENT 38 5 # FAN PS MODULE PRESENT (A) - 5 4
AC_OK_H 36 6 # FAN PS AC FAIL (A) - 6
W13P1 J7 J9 W25P1 TP7 J12
OTP WARNING 28 7 # FAN PS TEMP (A) - 7 1
IPA VOLTS CONTROL + 7 1 IPA VOLTS CONTROL (A) +
DC_OK_H 31 4 # FAN PS FAIL (A) - 4 2
IPA VOLTS CONTROL - 8 2 IPA VOLTS CONTROL (A) - C6 J3
REMOTE ON/ENABLE RETURN 21 0.1 3
# IPA PS INHIBIT (A) + 5 3 # IPA PS INHIBIT (A) + GND LOGIC RETURN 33 4
GND 6 8 GND TO AC/DC
J10 W26P1 POWER STAGE
1 IPA VOLTS CONTROL (B) + SHEET 2 1
FROM
CONTROL/ 2 IPA VOLTS CONTROL (B) - 2
J4
MONITOR # IPA PS INHIBIT (B) + 13 3 # IPA PS INHIBIT (B) + 3
STAGE GND 14 8 GND J1 E1 E2 4
SHEET 1 5 FAN VOLTS (B) +
J11
1 6 P12
PART OF 7 1 FAN VOLTS (REJECT LOAD A) +
2 E3 TO RF
GND 2 FAN VOLTS (REJECT LOAD A) +
# IPA PS INHIBIT (C) + 19 3 A9 +VE
8 J5 POWER STAGE
PS INTERFACE PWB 9 3 GND SHEET 3
GND 20 8
FAN B U8 10
C1
0.001
C3
0.1 4 GND
POWER SUPPLY
MODULE 11
FAN B 12 1
V CTRL INH 2
TP1 TP2 +VE SENSE 22 J6
3
E2
J13 W24P1 W24P2 J2 J1 13 4
1 FAN VOLTS CONTROL (B) + 1 23 V_PGM 14
PART OF
2 FAN VOLTS CONTROL (B) - 2 15
W14P1 J8 16
A9
N/A 19 3 # FAN PS INHIBIT (B) + 3 27 REMOTE ON/ENABLE -VE PS INTERFACE PWB
C4 C5 17 FAN B
GND 20 8 GND 8 0.001 0.1 J8 W14P1
18
7 # FAN PS MODULE PRESENT (A) -
19 MP AC TMP FAIL 8 # FAN PS AC FAIL (A) -
FROM AC/DC 20 TP4 TP5 TP6 TP3
VAC (2-3B4) 47 L1 9 # FAN PS TEMP (A) -
POWER STAGE
SHEET 1 VAC (3-1B4) 46 L2/NEUTRAL -VE SENSE 24 J2 W24P2 W24P1 10 # FAN PS FAIL (A) -
45 GND/EARTH PS PRESENT 38 5 # FAN PS MODULE PRESENT (B) - 5 15 # FAN PS MODULE PRESENT (B) -
AC_OK_H 36 6 # FAN PS AC FAIL (B) - 6 16 # FAN PS AC FAIL (B) -
TP7 J13
OTP WARNING 28 7 # FAN PS TEMP (B) - 7 17 # FAN PS TEMP (B) -
DC_OK_H 31 4 # FAN PS FAIL (B) - 4 18 # FAN PS FAIL (B) -
C6
REMOTE ON/ENABLE RETURN 21 0.1
GND LOGIC RETURN 33

W25P1 W13P1 TO CONTROL/


# IPA PS MODULE PRESENT (A) - 5 1 # IPA PS MODULE PRESENT (A) - MONITOR STAGE
# IPA PS AC FAIL (A) - 6 2 # IPA PS AC FAIL (A) - SHEET 1
J9
# IPA PS TEMP (A) - 7 3 # IPA PS TEMP (A) -
FROM AC/DC # IPA PS FAIL (A) - 4 4 # IPA PS FAIL (A) -
POWER STAGE W26P1
SHEET 2 # IPA PS MODULE PRESENT (B) - 5 9 # IPA PS MODULE PRESENT (B) -
# IPA PS AC FAIL (B) - 6 10 # IPA PS AC FAIL (B) -
J10 J7
# IPA PS TEMP (B) - 7 11 # IPA PS TEMP (B) -
# IPA PS FAIL (B) - 4 12 # IPA PS FAIL (B) -

5 15 N/A
6 16 N/A
J11
7 17 N/A
S2060216 V1 4 18 N/A

Figure SD-3: NV10/NV7.5 Transmitter - Ac-Dc Power Stage (Sheet 3 of 3)

Issue 3.3 2016-08-03 SD-3

You might also like