Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Department of Town and

eDCR-Scrutiny Report Country Planning


(SCR-dd/mm/yyyy:Scrutiny no.) : SCR-07/06/2018:79247 ver 1.4

Application Ref No : 201701102021493-68

ThanjavurLPA

Application Details and Building Type

Drawing File Name ATHIRAMPATINAM SCHOOL 7.6.17 dtcp - Survey No. 414,414,0
07.dwg
Unique ID SCR-07/06/2018:79247 Sub Division 1B(Part),1C1,
Date of Scrutiny Thursday, June 7, 2018
Revised Survey No.
Applicant Name Haji.Dr.S.Mohamed Aslam
Applicant Address HAJI.SMS.SHAIK JALALUDEEN FAMILY
Road Name PANCHAYAT ROAD
EDUCATIONAL TRUST487/78,SMS
avenue,karikadupattukottai Village Name Pazhanjur
Proposed at Address vallikollaikadu,Narashingapuram Locality Panchayat
panchayatpattukottai taluktanjore-614701 Taluk / District Thanjavur
Building Type Institutional
Public Building SCH PLR/FMB Area 9408.86

Premium FSI NO Document Area 9408.86


Super Imposed Plot Area 9245.67

Number of Floors Ground + 2 Floors

Page 1 of 7
Note: All Linear measurement values are in Metres and Area values in Square Metres
Powered by Vinza Solutions
Abbreviation : Exg = Existing, Pro = Proposed
Department of Town and
eDCR-Scrutiny Report Country Planning
(SCR-dd/mm/yyyy:Scrutiny no.) : SCR-07/06/2018:79247 ver 1.4

Application Ref No : 201701102021493-68

Building Type From Drawing INSTITUTIONAL

Parameter List as per DCR

Section Parameter Minimum Maximum Provided Violation Violation Result


%
3.3.1 Site Extent 892 N.A. 9245.67 N.A. N.A. Satisfied
3.3.2 Plot Frontage 25 N.A. 73.13 N.A. N.A. Satisfied
3.3 Road Width 9 N.A. 15.00 N.A. N.A. Satisfied
Road Type (NH / SH / Ordinary Road) N.A. N.A. Ordinary Road N.A. N.A. N.A.
3.3.4 Building Height N.A. 17.25 10.5 N.A. N.A. Satisfied
3.3.5 Floor Space Index N.A. 1.5 0.374 N.A. N.A. Satisfied
3.3.6 Plot Coverage percentage N.A. 60% 13.51% N.A. N.A. Satisfied

3.3.7 Front setback 6.00 N.A. 23.12 N.A. N.A. Satisfied


3.3.8 Side1 setback 6.00 N.A. 7.35 N.A. N.A. Satisfied
3.3.8 Side2 setback 6.00 N.A. 11.06 N.A. N.A. Satisfied
3.3.9 Rear setback 6.00 N.A. 7.03 N.A. N.A. Satisfied

Page 2 of 7
Note: All Linear measurement values are in Metres and Area values in Square Metres
Powered by Vinza Solutions
Abbreviation : Exg = Existing, Pro = Proposed
Department of Town and
eDCR-Scrutiny Report Country Planning
(SCR-dd/mm/yyyy:Scrutiny no.) : SCR-07/06/2018:79247 ver 1.4

Application Ref No : 201701102021493-68

Parameter List as per DCR

Section Parameter Minimum Maximum Provided Violation Violation Result


%
4.5 Residential corridor 1.5 N.A. Not Provided N.A. N.A.
Commercial & Educational corridor 2 N.A. 2.41 N.A. N.A. Satisfied
4.5 Hospital corridor 2.4 N.A. Not Provided N.A. N.A. N.A.
Schedule II Car Parking stalls Not Required N.A. 2 Nos. N.A. N.A. N.A.
Schedule II.1 Two Wheeler Parking stalls Not Required N.A. Not Provided N.A. N.A. N.A.
Schedule IV (2)
Physically Challenged Car Parking stalls 2 Nos. N.A. 2 Nos. N.A. N.A. Satisfied..2
(ii)
Schedule II Part
Vehicular Ramp Slope - One Way 1:8 N.A. Not Provided N.A. N.A. N.A.
III.2
Schedule II Part
Vehicular Ramp Width - One Way 3.5 N.A. Not Provided N.A. N.A. N.A.
III.6
Schedule II Part
Vehicular Ramp Slope - Two Way 1:8 N.A. Not Provided N.A. N.A. N.A.
III.2
Schedule II Part
Vehicular Ramp Width - Two Way 7.5 N.A. Not Provided N.A. N.A. N.A.
III.6
Schedule IV.3 (i)
Physically Challenged Ramp Slope 1:12 N.A. 1:0 12.00 100.00 Not Satisfied..1
(a)

Page 3 of 7
Note: All Linear measurement values are in Metres and Area values in Square Metres
Powered by Vinza Solutions
Abbreviation : Exg = Existing, Pro = Proposed
Department of Town and
eDCR-Scrutiny Report Country Planning
(SCR-dd/mm/yyyy:Scrutiny no.) : SCR-07/06/2018:79247 ver 1.4

Application Ref No : 201701102021493-68

Parameter List as per DCR

Section Parameter Minimum Maximum Provided Violation Violation Result


%
Schedule IV.3 (i)
Physically Challenged Ramp Width 1.5 N.A. 2 N.A. N.A. Satisfied..1
(b)
Schedule IV.3 (i) Physically Challenged Ramp - Distance
N.A. 9 7.35 N.A. N.A. Satisfied..1
(b) between landings
Schedule IV.3 (i) Physically Challenged Ramp landing
2x1 N.A. 2 x 1.76 0x0 0x0 Satisfied..1
(d) dimension
Schedule - IV.(2) Physically Challenged Parking Travel
N.A. 30 4.97 N.A. N.A. Satisfied..2
(i) Distance
Schedule V.1 (b) Rain Water Harvesting Required N.A. Provided N.A. N.A. Satisfied
Schedule V.1 (b) RWH Dimension 1.5 x 1 N.A. 1.82 x 0.00 N.A. N.A. Satisfied
4.9 Solar System Required N.A. Provided N.A. N.A. Satisfied
Schedule I (1) Open Space Reservation 924.567 N.A. 924.9173 N.A. N.A. Satisfied
4.12 Stilt Height 2.4 3 Not Provided N.A. N.A. N.A.
4.16 Transformer Yard (L x B) 5x5 or 10x4 N.A. 5.56 X 4.52 N.A. N.A. Satisfied
5.6.b (iii) Electrical Transformer Room (L x B x H) 6x4x2.75 N.A. Not Provided N.A. N.A. N.A.
4.20 EWS / LIG - Required Area N.A. N.A. Not Provided N.A. N.A. N.A.
4.20 EWS / LIG - Dwelling unit Area N.A. N.A. Not Provided N.A. N.A. N.A.

Page 4 of 7
Note: All Linear measurement values are in Metres and Area values in Square Metres
Powered by Vinza Solutions
Abbreviation : Exg = Existing, Pro = Proposed
Department of Town and
eDCR-Scrutiny Report Country Planning
(SCR-dd/mm/yyyy:Scrutiny no.) : SCR-07/06/2018:79247 ver 1.4

Application Ref No : 201701102021493-68

Parameter List as per DCR

Section Parameter Minimum Maximum Provided Violation Violation Result


%
4.24 (a) Basement Height 2.4 N.A. Not Provided N.A. N.A. N.A.
4.24 (a) Basement Height above GL N.A. 1.2 Not Provided N.A. N.A. N.A.
12. (1) (a) Gate Width 5.00 N.A. 8.00 N.A. N.A. Satisfied
4.21 Waste Disposal Not Required N.A. Not Provided N.A. N.A. N.A.

Parameter List as per Panchayat Rules

Section Parameter Minimum Maximum Provided Result


9 Habitation Room Minimum Area 7.2 N.A. 11.97 Satisfied..39
12 Habitation Room Ventilation 20% N.A. 20.34% Satisfied..39
11 Room Clear Height 2.4 N.A. 2.40 Satisfied
Habitation Room Minimum Width 2.5 N.A. 3.01 Satisfied..39

Page 5 of 7
Note: All Linear measurement values are in Metres and Area values in Square Metres
Powered by Vinza Solutions
Abbreviation : Exg = Existing, Pro = Proposed
Department of Town and
eDCR-Scrutiny Report Country Planning
(SCR-dd/mm/yyyy:Scrutiny no.) : SCR-07/06/2018:79247 ver 1.4

Application Ref No : 201701102021493-68

Floorwise Breakup

Non FSI Area Hospital Industrial


Typical Block Floor Name Total Builtup Covered Deduction Institutional
Name Area Parking Incidental Lifts and Fire Net Net Net
Structures Escapes
FSI Area FSI Area FSI Area
Others FLOOR-
1,255.39 - - - 6.48 - - 1248.91
GROUND
FLOOR01 1,103.40 - - - - - - 1103.40
FLOOR02 1,103.40 - - - - - - 1103.40
Total 3,462.19 - - - 6.48 - - 3455.71

Parking Details

Dwelling Two Wheelers Lorries


Parking Category Parking Area Cars Required Hotel Rooms Hospital Beds
Units Required Required
Total

Page 6 of 7
Note: All Linear measurement values are in Metres and Area values in Square Metres
Powered by Vinza Solutions
Abbreviation : Exg = Existing, Pro = Proposed
Department of Town and
eDCR-Scrutiny Report Country Planning
(SCR-dd/mm/yyyy:Scrutiny no.) : SCR-07/06/2018:79247 ver 1.4

Application Ref No : 201701102021493-68

Query Letter
Section Parameter Reference
Schedule IV.3 (i)
Physically Challenged Ramp Slope Refer to G.O.130 Rules
(a)

Disclaimer: This is an automatically generated electronic document which requires no signature. The generated report specifies information regarding compliance of
requirements of development control regulations(DCR) and connected building rules in respect of the building proposal. However, the decision to grant planning
permission for the building proposal is vested with the competent officer of Town and country planning department, Government of Tamil Nadu.

Page 7 of 7
Note: All Linear measurement values are in Metres and Area values in Square Metres
Powered by Vinza Solutions
Abbreviation : Exg = Existing, Pro = Proposed