A. Academic Buildings:: Card Readers: Designer Comments

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

ELON UNIVERSITY Revised 28 Dec 2006

CARD READER CRITERIA


CARD READERS: DESIGNER COMMENTS
As described below door access card swipe readers and associated hardware are to be
integrated with the existing card security system (Lenel OnGuard Access Control) via the
campus Ethernet.

A. Academic Buildings:
The main entrance door to academic buildings shall have a card access system.

B. Residential Buildings:
Main entrances to residential halls housing more than 20 people shall have a card access
system. Suite doors, and apartment unit entry doors, will have card access readers if
they have more than 20 people each.

C. Hardware by Lenel Corp will include:


LNL-500 Intelligent System Controller
LNL-ETHLAN-MICR Micro Serial Server
LNL-1300/1320 Reader Interface Module
LNL-AL400ULX UL listed Power Supply 12/24 VDC, 4 amp output
LNL-2005W Magnetic Card Access Reader 12VDC, weatherized
PS873X871-2 Power Supply with 873-BB Battery Backup
EPT10-SP28 Electric Power Transfer Hinge
50251 Request to Exit Switch
SR1076 Magnetic Contact
PS-12120 12VDC/12AH Battery
Electric Panic Bar exit hardware by Von Duprin Corp (or retrofit kit for existing mechanical panic
bars)

D. Electrical Requirements:
1. In the Communications closet – 110v/120v AC nonswitched circuit.
2. At the door – 110v/120v AC nonswitched circuit for PS873X871-2 Power supply.

3. Door contact, card access reader and power transfer hinge to be connected to Reader
Interface Module through concealed wiring (i.e. conduit/EMT).

E. Data/networking Requirements:
1. Reader Interface Module installed above the door/ceiling and powered from from the
communications closet with 2 conductor,18 awg, NS, plenum rated cable (or enclosed
in conduit if hard ceiling)
2. Elon will provide campus Ethernet connection in Communication Closet in each
building. Installer to provide wiring from door device to Communication Closet.
2. Reader Interface Module connected to System Controller with 4 conductor, 18awg,
OAS, plenum rated, communitcations cable (or enclosed in conduit if hard ceiling)

General Note: Certified Installer must be used.

Any deviations from these criteria are noted above in the comments section.

DESIGNER SIGNATURE_________________________

389977411.xls
ELON UNIVERSITY
DOOR HARDWARE CRITERIA
06/15/2018

Door Locks
Door Type DESCRIPTION Designer Comments
1  Schlage D73 Rd (Removable
Residence Hall (Bedroom) core not factory pinned (Lockable
AND by button from inside and key
Offices only from outside))
 Athens Trim - Lever Handle
 626 (brushed chrome finish)
 2-3/4" Backset

2 Residence Hall  Schlage D40S ((Lockable from


(Bathroom In suite) inside only with push button -No key)
PLUS a Schlage B180N
Deadbolt - Thumb Turn (on bedroom side)
 2-3/4" Backset
 626 (brushed chrome finish)
 Athens trim - Lever Handle

3 Residence Hall  Schlage D40 S (Lockable from


(Bathroom Not In suite) inside only with push button -No key)
 2-3/4" Backset
 Athen Trim - Lever Handle
4 Residence Hall Closets  Schlage F10
 Ventura Trim (No Athens in F-
series)
 2-3/4" Backset
 626 (brushed chrome finish)

5 Classroom  Schlage D70 Rd (Not Lockable


from inside)
 Athens Trim - Lever Handle
 626 (brushed chrome finish)
 2-3/4" Backset

6 Bathroom  No DeadBolts - No locks


(Not Residence Hall)  Push / Pull required
7 Mech, Telephone  Schlage D80 Rd (Key access only,
Elect. / Custodial Rooms No push button)
 Athens
 626 (brushed chrome finish)
 2-3/4" Backset

Door Hardware
Device DESCRIPTION Designer Confirmation
1 Door Closures LCN - 4041 (4000 Series)

2 Panic Devices Von Doprin 99 (dog down by Key)

3 Center Mullions  Should be key removable

4 Bathroom Hinges 4-1/2 x 4-1/2


(Plated w/ S.S. Pins)

5 Solid Core Doors Hinges 4-1/2 x 4-1/2


( ball bearing hinges)

6 Continuous Hinges Use "SELECT" or "MARCO"


( exterior residence hall only)

Note:
1. Keyway is (Elon To Provide)
2. Contractor provides all locks with interchangable cores.
( ZERO bitting only).
3. Elon provides pinning and key cutting.
4. Contractor submittal for hardware to be sent concurrently to AE and Elon
for review.

Any deviations from these criteria are noted above in the comments section.
.
Designer Signature

389977411.xls

You might also like