EX0006, WRONG COMBINATION OF M-CODES, ALM0006, A7.

5, Any wrong
combination M-commands have been mistakenly given at the same time.

EX0013, M85-COMMAND WITH SPINDLE ON, ALM0013, A0.0, An M85


command has been given during spindle rotation or milling rotation.

EX0018, NEED ZERO-RETURN, ALM0018, A0.2, A cycle start has been activated
without executing the X-axis and Z-axis zero returns after a machine lock cancel.

EX0019, WORK-COUNTER AT FULL COUNT, ALM0019, A0.3, A cycle start has


been activated with the PC or external work counter at full count.

EX0020, EDITING SWITCH KEY IS ON, ALM0020, A0.4, A cycle start has been
activated with the Editing Key Switch on.

EX0023, START INTERLOCK ON (EXT.), ALM0023, A0.5, The cycle operation


has been started while an external start interlock signal has been input.

EX0024, CHUCK UMCLAMPED, ALM0023, A0.6, A cycle start has been activated
with the chuck unclamped.

EX0026, DOOR NOT CLOSED, ALM0026, A0.7, The cycle operation has mistakenly
been started without door closed.

EX0029, TAILSTOCK INCHING/ QUILL NOT OUT, ALM0029, A1.0, A cycle start
has been activated during tailstock inching or with the tailstock quill not OUT.

EX0033, ONLY HANDLE MODE, ALM0033, A7.6, The jog push button has been
pressed together with the O.T. release button after the hard O.T. limit switch has been
tripped.

EX0064, AUTO-DOOR OPEN, ALM0064, A10.0, A auto-door closed detection signal


has been deactivated without an auto-door close command having been given.

EX0068, SET UP MODE TIME OVER, ALM0068, A10.2, Door interlock cancel
time has been over.

EX0069, DOOR LOCK CHECK TIME OVER, ALM0069, A10.3, Door lock
complete signal has not been turned ON after elapsing the time set in timer.

EX0093, TAILSTOCK OUT PERMIT ERROR, ALM0093, A16.4, The tailstock


quill OUT permission signal is abnormal. Check the monitor circuit.

EX0094, INTERRUPTION SIGNAL ON, ALM0094, A16.5, The motor interruption


check signal is input at operation ready completion of each motor. Check the motor
interruption circuit.

EX0095, TURRET ILLEGAL MOVEMENT, ALM0094, A16.6, The turret attempts


to move without command. Check the turret output driver or clamp signal.
EX0096, INTERRUPTION FAILURE, ALM0096, A16.7, The motor interruption
check signal is not input at operation ready completion of each motor. Check the motor
interruption circuit.

EX0301, T-CODE COMMAND (#2), ALM0301, A7.7, An invalid T-command has


been given. (Head2)

EX0302, T-CODE COMMAND (#1), ALM0302, A1.1, An invalid T-command has


been given. (Head1)

EX0303, M17/M18-COMMAND BUT AUTROT = [1], ALM0303, A1.2, Either an


M17 or M18 command has been given while the turret indexing short-path control is
effective. (PC parameter AUTOROT= [1])

EX0305, TAILSTOCK UNCLAMPED (#2), ALM0305, A8.0, A T-command has been


given with the tailstock umclamped. (Head2)

EX0312, NEED TURRET ZERO-RETURN, ALM0312, A1.3, A T-command has


been given with the turret station not indexed to the correct position. Index the station
manually.

EX0320, DURING POLYGON MODE, ALM0320, A1.4, A T-command has been


given during polygon mode.

EX0322, TAILSTOCK UNCLAMPED, ALM0322, A1.5, An M3, M4, M13, M14 or


M39 command has been given with the tailstock unclamp.

EX0324, TAILSTOCK UNCLAMPED (#1), ALM0324, A1.6, A T-command has been


given with the tailstock unclamped. (Head1)

EX0332, TAILSTOCK NOTCONNECT POSITION, ALM0332, A1.7, An M79


command has been given with tailstock not in connecting position.

EX0333, TAILSTOCK INCHING/QUILL OUT, ALM0333, A2.0, An M78 or M79


command has been given with the tailstock quill OUT or in the inching state.

EX0334, TURRET PARAM. MUST BE 8, 10, 12, ALM0344, A2.1, A value other
[8], [10], or [12] was input to the paramter as a setting for the number of turret station.
Reset the parameter.

EX0350, PHASE-B SIGNAL NOT ON (#2), ALM0350, A12.1, The turret indexing
phase-B count signal has not been activated. This error is caused when a phase-A signal
is output twice in a row. Either the proximity switch for the phase-B counter is defective
or it is improperly adjusted. (Head2).

EX0351, PHASE-A SIGNAL NOT ON, ALM0351, A14.0, The turret indexing phase-
A count signal has not been activated. This error is caused when a phase-B signal is
output twice in a row. Either the proximity switch for the phase-A counter is defective
or it is improperly adjusted. (Head2)
EX0352, PHASE-B SIGNAL NOT ON (#1), ALM00352, A10.7, The turret indexing
phase-B count signal has not been activated. This error is caused when a phase-A
signal is output twice in a row. Either the proximity switch for the phase-B counter is
defective or it is improperly adjusted. (Head1)

EX0353, PHASE-A SIGNAL NOT ON (#1), ALM0353, A11.0, The turret phase-A
count signal has not been activated. This error is caused when a phase-B signal is output
twice in a row. Either the proximity switch for the phase-A counter is defective or it is
improperly adjusted. (Head1).

EX0354, PHASE-A NOT AGREE WITH PHASE-B (#2), ALM00354, A16.3,


Current position data in the phase-A signal counter and the phase-B signal counter do
not agree. Either the proximity switch for the counter is defective or it is improperly
adjusted. (Head2)

EX0355, PHASE-A NOT AGREE WITH PHASE-B (#1), ALM0355, A11.1, Current-
position data in the phase-A signal counter and the phase-B signal counter do not agree.
Either the proximity switch for the counter is defective or it is improperly adjusted.
(Head1)

EX0356, TURRET INDEX TIME UP (#2), ALM0356, A17.0, Turret indexing has not
been completed within the specified time. (Head2)

EX0357, TURRET INDEX TIME UP (#1), ALM0357, A11.2, Turret indexing has not
been completed within the specified.

EX0374, TOOL LIFE UP (#1), ALM0374, A11.3, Tool life up. (Head1)

EX0375, TOOL LIFE UP (#2), ALM0374, A17.1, Tool life up. (Head2)

EX0377, PHASE-A COUNTER ERROR, ALM0377, A11.4, Current value of phase-


A counter is not [1] at pass though the turret home position during turret indexing.Either
the home position detection switch or the phase-A count switch is defective or they are
improperly adjusted. (Head1)

EX0378, PHASE-B COUNTER ERROR (#1), ALM0378, A11.5, Current value of


phase-B counter is not [1] at pass though the turret home position during turret
indexing. Either the home position detection switch or the phase-A count switch is
defective or they are improperly adjusted.

EX0380, TAILSTOCK CLAMP/UNCLAMP TIME UP, ALM0380, A11.6, The


tailstock clamp/unclamp operated has not been completed within the specified time.

EX0381, TAILSTOCK UNCLAMPED, ALM0381, A11.7, The clamp check signal


has been deactivated with the tailstock was clamped. input.

EX0383, PHASE-A COUNTER ERROR (#2), ALM0383, A17.2, Current value of


phase-A counter is not [1] at pass though the turret home position during turret
indexing. Either the home position detection switch or the phase-A count switch is
defective or they are improperly adjusted.(Head2)
EX0384, PHASE-B COUNTER ERROR (#2), ALM0384, A17.3, current value of
phase-B counter is not [1] at pass though the turret home position during turret
indexing. Either the home position detection switch or the phase -A count switch is
defective or they are improperly adjusted. (Head2)

EX0386, NEED TURRET ZERO RETURN (#1), ALM0386, A12.0, The turret clamp
check limit has been deactivated during cycle start. (Head1)

EX0393, NEED TURRET ZERO RETURN, ALM0393, A17.4, The turret clamp
check limit switch has been deactivated during cycle start.

Ex0401, M3/M4/M13/M14 COMMAND ERROR, ALM0401, A2.2, Any of the


following commands have been given improperly: M4; during normal spindle rotation
M3; during reverse spindle roatation M14; during normal milling rotation or M13
during reverse milling rotation.

EX0404, M3/M4/M13/M14 ERROR; BAD S-CODE, ALM0405, A2.3, An M3, M13,


or M14 command has been given either without given an S-code command after turning
on the power or after giving an SO command.

EX0405, M41, M42, M43, M44 COMMAND MISSING, ALM0405, A2.4, An M3,
M4 or M19 command has been given without giving either an M41, M42, M43, 0r M44
command.

EX0406, SPINDLE INTERLOCK SIGNAL ON, ALM0406, A2.5, An M3, M4 M13,


M14, M19 or M39 command has been given while the external spindle interlock signal
activated.

EX0407, BAD SPINDLE DIRECTION, ALM407, A2.6, The direction of spindle (or
milling) rotation has been changed or while shifting the operation mode from automatic
to manual, or from manual to automatic.

EX0410, M10/M11/W/ SPINDLE OR MILL ON, ALM0410, A2.7, An M10, M11


command has been given during spindle rotation or milling rotation.

EX0411, M3/M4-COM WITH SPINDLE JOG ON, ALM0411, A3.0, A M3, M4, or
M39 command has been given during spindle jogging.

EX0412, M3/M4/M13/M14 W/ CHUCK UMCLAMP, ALM0412, A3.1, An M3, M4,


M13, or M14 command has been given with the chuck unclamped.

EX0421, DURING TAILSTOCK INCHING, ALM0421, A3.2, A M3, M4, M13, or


M14 command has been given during tailstock quill inching.

EX0429, M13/M14/M39 BUT MILLING JOG ON, ALM0429, A3.3, A M13, M14,
or M39 command has been given during milling jogging.

EX0448, M-COM BUT NOT AT MILL STATION, ALM0448, A3.4, With the rotary
tool station not indexed, either anM13, M14, M39 or M3, M4 during M90 command
mode, command has been given.
EX0449, NOT MILLING STATION, ALM0449, A3.5, A G251 (polygon) command
has been given at the position other than the milling stations.

EX0451, SPINDLE DRIVE UNIT ALARM, ALM0451, A12.1, The spindle drive unit
alarm has been activated.

EX0453, MILL SPINDLE ALARM, ALM0453, A12.3, A milling amplifier alarm has
been activated.

EX0456, SPINDLE INDEX TIME UP, ALM0456, A12.4, Spindle indexing has not
been completed within the specified time.

EX0461, TAILSTOCK OUT SWITCH NOT ON, ALM0461, A12.5, The tailstock out
check signal has been deactivated with the tailstock quill out.

EX0470, GEAR CHANGE TIME UP, ALM0470, A12.6, Gear change has not been
completed within the specified time.

EX0471, GEAR CHECK LIMIT SWITCH NOT ON, ALM0471, A12.7, The gear
check limit switch has been deactivated during spindle rotation.

EX0480, SPINDLE ORIENTATION TIME UP, ALM0480, A13.0, Spindle


orientation has not been completed within the specified time.

EX0551, ELEC. CONTROL UNIT OVERHEATING, ALM0551, A13.1, Abnormal


increase in electrical control unit temperature.

EX0554, OIL AIR PRESSURE STILL DOWN, ALM0554, A10.4, No increase in oil
air pressure. Possible cause is broken piping or motor failure.

EX0560, AIR PRESSURE DROP, ALM0560, A13.2, Air pressure has dropped.

EX0561, OIL PRESSURE LOW, ALM0561, A13.3, Decrease in hydraulic pressure.

EX0562, LUBR. OIL PRESSURE STILL DOWN, ALM0562, A13.4, No increase in


lubrication oil pressure. Possible cause is broken piping or motor failure.

EX0563, NO DROP IN LUBR. OIL PRESSURE, ALM0563, A13.5, Pressure has not
decreased within the specified time after turning the cycle pump OFF. Possible cause is
failure in the pressure switch or the magnet.

EX05564, NO DROP IN OIL AIR PRESSURE, ALM0564, A10.5, Pressure has not
decreased within the specified time after turning the oil air pump OFF. Possible cause is
failure in the pressure switch or the magnet.

EX0567, LUBRICATION WATCH DOG ALARM, ALM0567, A13.6, Lubrication


pump pressure detection switch has not been activated within the specified time.

EX0570, INSUFFICIENT LUBRICATION OIL, ALM0570, A13.7, Insufficient


lubrication oil.
EX0571, INSUFFICIENT OIL IN AIR, ALM0571, A10.6, Insufficient oil in oil air
lubrication system.

EX0590, THERMAL TRIP, ALM0590, A10.1, One of the thermal relays in the
auxiliary motor has been tripped.

EX0904, L-TURRET NOT AT Z ZERO RETURN, ALM0904, A8.1, The parts


catcher OUT command has been given while the lower turret Z-axis is not zero-point.

EX0905, PRESETTER ARM DOWN, ALM0905, A8.2, The parts catcher OUT
command has been given with the presetter arm rise check switch deactivated.

EX0907, PRESETTER ARM DOWN, ALM0907, A8.4, The presetter arm rise check
switch has been deactivated while the parts catcher is out.

EX0911, NO MORE BAR STOCK, ALM0911, A3.7, Bar stock has run out.

EX0913, M71-COM WITH SPINDLE OR MILL ON, ALM0913, A4.0, An M71


command has been given during spindle rotation or milling rotation.

EX0915, NEED Z-AXIS ZERO-RETURN, ALM0915, A4.1, An M17 command has


been given while X, Z axis at the zero point.

EX0916, PARTS CATHCER NOT HOME POSITION, ALM0916, A4.2, M71 or


M85 command has been given while the parts catcher is not in the home position.

EX0922, M70-COMMAND BUT CHUCK CLAMPED, ALM0922, A4.3, An M70


command has been given while the chuck is clamped.

EX0923, SENSOR ON, ALM0923, A7.2, An M72 command has been given while
sensor is turned on.

EX0942, SENSOR ARM OUT, ALM0942, A0.1, M3, M4 or T-code command is


specified with extending the positioning sensor arm.

EX0945, ROBOT COMMAND ERROR, ALM0945, A4.4, ROBOT command has


been given while the machine is not in home position.

EX0946, ROBOT ARM IN, ALM0946, A4.5, The following commands have been
given while the ROBOT arm is moving IN. (M8, M3/4, M13/14, M38, M39, M71,
M86, T-command)

EX0951, CONTACT BUT NO PRESET MODE, ALM0951, A14.2, The sensor has
been activated without setting the presetter mode.

EX0952, CONTACT AS ARM RISES, ALM0952, A14.3, The sensor has been
activated with the presetter ascending.

EX0953, ARM UP SIGNAL OFF IN AUTO MODE, ALM0953, A14.4, The presetter
arm UP detection signal has been deactivated during automatic mode.
EX0956, TWO OR MORE SENSORS ARM ON, ALM0956, A14.5, Two sensors or
more have been activated during presetter mode.

EX0957, PARTS CATCHER TIME UP, ALM0957, A14.6, The parts catcher
operation has not been completed within the specified time.

EX0959, BARFEEDER EMG STOP, ALM0959, A14.7, The barfeeder is in


emergency stop state.

EX0962, ROBOT CYCLE TIME UP, ALM0962, A15.0, ROBOT cycle has not been
completed in the specified time.

EX0964, NO MORE WORKPIECES IN ROBOT, ALM0964, A15.1, On models


equipped with a ROBOT, workpieces have run out.

EX0965, FULL PIECES IN ROBOT, ALM0965, A15.2, On models equipped with


ROBOT, the ROBOT is completly full of workpieces.

EX0966, ROBOT ALARM, ALM0966, A15.3, The ROBOT alarm has been output.

EX0967, LOADER EMG STOP, ALM0967, A20.4, The loader state is in emergency
stop state.

EX0968, NO MORE BAR STOCK, ALM0968, A15.4, Bar stock has run out.

EX0978, SENSOR ALARM, ALM0978, A17.5, Disconnection alarm is occured in the


positioning sensor amplifier.

EX0979, CHUCK CLAMP TIME UP, ALM0979, A17.6, The chuck clamp operation
has not been completed within the specified time when work seating check spec.

EX0999, SEQUENCE PROGRAM ERROR, ALM0999, A15.5, Abnormality in


sequence program. Please contact your dealer.

EX1005, PUT IN THE NEW MATERIAL, ALM1005, A4.6, Please supply new work
piece.

EX1024, DOOR MUST BE OPENED ONCE, ALM1024, A4.7, Open and close the
door before starting new cycle.

EX1034, MUST BE POWER OFF, ALM1034, A7.3, Must be power off.

EX1035, MONITOR PARAMETER ALARM (#1), PER1035, A18.0, Parameter for


load monitor function is improperly set. (#1)

EX1036, TEACHING ALARM (#1), PER1036, A18.1, Alarm occurs during teaching
mode. (#1)

EX1037, SPINDLE OVERLOAD (#1), PER1037, A18.5, Spindle is overloaded. (#1)


EX1038, X-AXIS OVERLOAD (#1), PER1038, A18.6, X-axis is overloaded. (#1)

EX1040, Z-AXIS OVERLOAD (#1), PER1040, A18.7, Z-axis is overloaded. (#1)

EX1041, SPINDLE OVERLOAD (#2), PER1041, A19.5, Spindle is overloaded. (#2)

EX1042, X-AXIS OVERLOAD (#2), PER1042, A19.6,X-axis is overloaded. (#2)

EX1043, Z-AXIS OVERLOAD (#2), PER1043, A19.7, Z-axis is overloaded. (#2)

EX1044, MONITOR PARAMETER ALARM (#2), PER1044, A19.0, Parameter for


load monitor function is improperly set.

EX1045, TEACHING ALARM (#2), PER1045, A19.1, Alarm occurs during teaching
mode. (#2)

EX1047, MACHINE SPEC. PARAM. CLEARED, PER1047, A8.5, Parameter for


machine spec. is improperly set.

EX1050, SPINDLE LOAD WARNING (#1), MER1050, A18.2, Spindle is overloaded


warning level. (#1)

EX1051, X-AXIS LOAD WARNING (#1), MER1051, A18.3, X-axis is overloaded


warning level. (#1)

EX1053, Z-AXIS LOAD WARNING (#1), MER1053, A18.4, Z-axis overload warning
level. (#1)

EX1054, SPINDLE LOAD WARNING (#2), MER1054, A19.2, Spindle is overloaded


warning level.

EX1055, X-AXIS LOAD WARNING (#2), MER1055, A19.3, X-axis is overloaded


warning level. (#2)

EX1056, Z-AXIS LOAD WARNING (#2), MER1056, A19.4, Z-axis is overloaded


warning level. (#2)

EX1067, DOOR CLOSE SIGNAL OFF, ALM1067, A2o.1, Auto-door close detection
signal turns off.

EX1068, DOOR OPEN/CLOSE TIME OVER, ALM1068, A20.2, Auto door open or
close detect single was not turned on within allowable time.

EX1069, DOOR SENSOR TEST ERROR, ALM1069, A20.3, Area sensor input
signal (X1009.5) does not turn off.

EX1300, PRESETTER ARM NOT FULLY RAISED, ALM1300, A5.0, An M25 or


M26 command has been given with the presetter arm not fully raised.
EX1301, TAILSTOCK UNCLAMPED, ALM1301, A5.1, An M25 M26 command has
been given with the tailstock unclamped.

EX1302, TURRET INDEXING, ALM1302, A5.2, An M25, M26, or M79 command


has been given during turret indexing.

EX1303, M25/M26 BUT SPINDLE ON, ALM1303, A5.3, An M25 or M26 command
has been given during spindle rotation.

EX1304, M25/M26/M79 BUT MILLING ON, ALM1304, A5.4, An M25, M26, or


M79 command has been given during milling tool rotation.

EX1409, M3/M4/M90 BUT SPINDLE INDEX MODE, ALM1409, A5.5, An M3,


M4, or M90 command has been given during spindle indexing mode.

EX1416, M3/M4/M19 BUT SPINDLE BRAKE ON, ALM1416, A5.6, An M3, M4, or
M19 command has been given with the spindle brake activated.

EX1417, M3/M4 BUT SPINDLE LOCKPIN OUT, ALM1416, A5.7, An M3 or M4


command has been given with the spindle indexing pin not at the [IN] state.

EX1419, NEED TURRET ZERO-RETURN, ALM1419, A6.0, When the turret


station has been improperly indexed, either an M13/M14/ M39 command has been
given or an M3/M4 command has been given under M90 command mode (with turret
still improperly indexed).

EX1421, M13/M14 BUT SPINDLE BRAKE OFF, ALM1421, A6.1, An M13 or M14
command has been given with the spindle brake not activated.

EX1422, PRESETTER ARM NOT FULLY RAISED, ALM1422, A6.2, An M3, M4,
M13, M14, or M39 command has been given with the presetter arm not fully raised.

EX1424, M-COMMAND BUT SPINDLE ON, ALM1424, A6.3, An M39, M40, M45,
M68, M90, M91 or M312 command has been given during spindle rotation.

EX1426, M-COMMAND BUT MILL ON, ALM1426, A6.4, An M39, M46, M69,
M90, or M91 command has been given during milling rotation.

EX1433, M-COMMAND BUT NOT TURNING MODE, ALM1433, A6.5, An M3,


M4, or M19 command has been given while not in turning mode.

EX1435, NOT MILLING OR TURNING MODE, ALM1435, A6.6, An M13, M14,


or M39 command has been given while neither in milling mode nor turning mode.

EX1442, M39/M45/M68 DURING M90 MODE, ALM1442, A6.7, An M39, M45, 0r


M68 command has been given during M90 (spindle/milling synchronized operation).

EX1444, M-COM BUT NOT IN TURNING MODE, ALM1444, A7.0, An M40,


M41, M42, M43, M44, or M90 command has been given while not in turning mode.
EX1451, C-AXIS OFF WHILE SPINDLE ON, ALM1451, A15.6, C-axis connection
cancel detection has been deactivated during spindle rotation.

EX1452, C-AXIS CONNECTION TIME UP, ALM1452, A15.7, C-axis connection


time is up.

EX1456, C-AXIS CONNECT OFF: C-AXIS ON, ALM1456, A16.0, C-axis


connection detection has been deactivated during C-axis connection.

EX1457, OIL COOLER ALARM, ALM1457, A16.1, Oil cooler is overloaded or oil
temperature is abnormal.

EX1458, MILLING HOLDER JOIN TIME UP, ALM1458, A16.2, Milling holder
has not joined to the drive within the specified time.

EX1921, M/S/T CODE IN SAME BLOCK, ALM1921, A7.1, M85/86 command and
T/S-code command have been given in the same block. Specify M85/86 in a single
block.

EX1924, M39/ T-CODE IN SAME BLOCK, ALM1924, A7.4, Both an M39


command and a T-code command have been in same block. Specify M39 in a single
block.

EX1928, DOOR NOT CLOSED, ALM1928, A3.6, Shutter open/close command has
been given while the front door is not closed.

EX1936, CHUCK UNCLAMP, ALM1936, A08.0, An forkardt chuck index command


has been given with the chuck unclamped.

EX1937, SPINDLE ON, ALM1937, A08.1, An forkardt chuck index command has
been given during spindle rotation.

EX1938, FORKARDT CHUCK NOT HOME POSITION, ALM1938, A08.2,


Forkardt chuck index command has been given while the forkardt chuck is not in home
position.

EX1958, ROBOT POWER NOT TURNED ON, ALM1958, A17.7, Robot power is
not turned ON.

EX2027, NC ON OPERATING, ALM2027, A08.6, Interlock ket switch was turned to


release side during automatic cycle or feed hold.

EX2028, PUSH SINGLE BLOCK SW. ON, ALM2028, A08.7, Cycle start button was
pressed at single block OFF status.

EX2029, CYCLE START NOT PERMITTED, ALM2029, A09.0, Single block was
turned off or door was opened during automatic cycle.

EX2033, DOOR SENSOR DETECT, ALM2033, A09.7, Area sensor detects obstacles
after specifying auto-door close command.
Check out www.pinpointcnc.com for machine repair information, procedures and other
products.

Fo Machine Tool Parts and Accessories, go to www.globalmachineparts.com

Free cnc repair and troublshooting info at www.pinpointcncblog.com

For information on Toyooki products, go to www.toyookivalve.blogspot.com

Go to www.ikurafans.blogspot.com for information on Ikura Seisakusho Fans

Go to www.industrialoilcooler.com for information on Industrial Oil Coolers and


Industrial Oil Chillers

You might also like