Professional Documents
Culture Documents
17 Bid BUYDMD031617 Section II
17 Bid BUYDMD031617 Section II
CPRI
www.tenderwizard.com/CPRI
Note :The Offers should be submitted only in this format otherwise the offer will be liable for rejection
A detailed technical catalogue/literature/phamplet and any other technical details shall be sent in hard copy in a sealed cover superscribing enquiry number
and due date so as to reach the following address with the due date and time. This is very much essential to evaluate your offer.
Page 1 of 4
3 Pneumatic General Information:
Control: Electronic Pneumatic Control system should contain unified digital
flow controllers (DFC10) and digital
pressure controllers (DPC11) are arranged for complete electronic gas
management for all GC units.
Each gas controller has built-in mass flow sensor to ensure accurate
operating flow level. Membrane type valve is
resistant to impact conditions.
Electronic pneumatic control should have atmospheric temperature
and pressure compensation to achieve
maximum accuracy of gas pressure/flow providing.
With digital gas control GC work becomes more accurate and flexible
with many useful programmable functions
based on DFPC such as flame ignition control, leak check, gas economy
function, gas flow and pressure
programming and others.
Page 2 of 4
7 Thermal General uses: sensitive to all compounds, except carrier gas
conductivity Separation Column Suitability: Packed, micropacked
detector (TCD): Minimum detectable level (MDL) < 0.8 ng/mL (for propane or heptane)
Linear dynamic range: > 105
Maximum Temperature: 200°C
Filament type: Tungsten (standard), Gold-coated filaments (optional)
8 Micro Thermal General uses: sensitive to all compounds, except carrier gas
conductivity Separation Column Suitability: Capillary, micropacked
detector (μ-TCD): Minimum detectable level (MDL): < 1 ng/mL (for propane or heptane)
Linear dynamic range: > 105
Maximum Temperature: 200°C
Cell volume 10 μL
Filament type: Tungsten (standard)
9 Catalytic General uses: for combustible gases (mostly used for hydrogen, CO, CH4
combustion or
detector (CCD): oxygen traces determination)
Separation Column Suitability: Packed (standards), Capillary (option)
Minimum detectable level (MDL) < 0.5 ng/mL (for Hydrogen)
Linear dynamic range: > 103
Maximum Temperature: 80°C or 200°C depending on filaments type
Page 3 of 4
12 Data System: Communication Interfaces: LAN Ethernet (standard)
Wifi adapter (optional)
Analogue output (option)
aux control signal (5V)
Start in, ready out (option)
Instrument keyboard and display: LED status board
Windows based tablet or similar connected via Wifi is
recommended for field applications.
Control, Data Acquisition and Analysis
Software:
Originally developed software to provide a full control of all
the instruments manufactured , not only gas
chromatograph, but also a range of peripherals.
Note : Compliance to meeting all of the above technical specification requirement should be furnished in detail against each serial number in GTP column with
supporting technical write up, illustrations, schematics, single line diagrams, drawings, catalogues of proposed sub-equipment & instruments suppliers etc.
PN : 1. A detailed technical catalogue/literature/phamplet and any other technical details shall be sent in hard copy in a sealed cover super scribing tender
enquiry number and due date so as to reach the following address within the due date and time. This is very much essential to evaluate your offer.
2. Letter of authorization issued by the foreign Principal shall also be sent by the Indian agents who have offered on behalf of their Principals.
The Joint Director (Purchase)
Central Power Research Institute,
Post Box No.8066
Prof.Sir C.V.Raman Road, Sadashivanagar Post Office,
BANGALORE-560 080. INDIA
Ph. No.080-23602919 / 23602829
Fax : 080-23604446
Page 4 of 4