Contents
The ecoTEC range 4
The vSMART control 5
Combi boilers 6
System boilers 18
Open vent boilers 24
Flue solutions 30
Schematics and wiring diagrams 34
uniSTOR unvented cylinders 46
Weather compensating controls 50
timeSWITCH controls 52
Room thermostats 53
Controls compatibility finder 54
Vaillant Advance 55
Service 56
Vaillant training 58
Order numbers 60
Notes 62
2 3
The TECHNICAL Brochure
Combi boilers ecoTEC plus 825, 832, 835, 838 and 938
Combi boilers
all available (see pages 54 - 61)
High efficiency combination boilers are an increasingly popular • Highly efficient and economical to run
With up to an 89.3% efficiency rating (SAP 2009)
choice in UK homes and now account for well over half of all new ErP rated A • Quiet Mark accreditation
Thanks to being ultra quiet whilst in operation
domestic boilers installed in UK every year.
• Instant hot water delivery in just 5 seconds*
ecoTEC condensing combi boilers do not require The ecoTEC plus 938 is a 38kW high efficiency Meaning no need for a storage tank or cylinder • Step by step full text Installation Wizard
hot water cylinders or cold water storage tanks, storage combination boiler, which has been designed For quicker, “first time right” set up and
minimising the space they occupy. especially for larger homes that have a higher hot installation
• Flame lift detection system
water demand. Featuring an innovative integrated Enabling more efficient and quieter combustion
Vaillant’s range of combi boilers is broad enough to • Compatible with aroTHERM air to water heat
hot water device at the back of the boiler called the
ensure the ideal solution for all house types — from pump hybrid system
‘actoSTOR’. This separate 15 litre ‘actoSTOR’ unit
a one-bedroom/bathroom flat through to a four- Making the perfect entry into renewable systems
provides exceptional hot water delivery which re-
bedroom property with two bathrooms.
charges in just 2 minutes. All of this without the need Below is a list of related Vaillant accessories, designed to help maximise your system to its full potential:
The ecoTEC plus high efficiency combi boiler for you to install a separate hot water cylinder.
range uses premium components for outstanding
performance, quality, reliability and efficiency, Heating controls: Room thermostats:
the very best in home heating. The ecoTEC timeSWITCH 150 VR 81
combination range is available in a wide range of timeSWITCH 160 VRT 50
outputs from 25kW to 38kW. VRT 15
Renewable solution:
VRT 350
aroTHERM air to water
VRT 350f (wireless version) heat pump hybrid system
6 **Compatible with ecoTEC pro 24, pro 28, pro 28 LPG, pro 30, ecoTEC plus 825, ecoTEC plus 832, ecoTEC plus 832 LPG, ecoTEC plus 835 and ecoTEC plus 838 only 7
The TECHNICAL Brochure
Combi boilers
combi boilers offers premium performance and fuel the built-in quality, reliability and performance
efficiency whilst creating a solid basis for the heating you’d expect from Vaillant, with a simple design manufacturer
• Total system solution available from one Intelligent controls and accessories all available (see
system of larger homes. manufacturer and approach.
pages 54 - 61)
The range features 32kW and 38kW models, which Intelligent controls and accessories all available (see The range features 24, 28 and 30kW models, making
pages 54 - 61) this boiler perfect for homes with a smaller heating
can deliver much higher than average central • Dedicated models available for LPG
heating outputs, making the ecoTEC exclusive a must and hot water requirements. Giving a solution for off-gas areas
• Quiet Mark accredited
have for larger properties. Key features and benefits:
Thanks to being ultra quiet whilst in operation
Key features and benefits: • Highly efficient and economical to run • Wide modulation range of up to 1:4
With up to an 89.3% efficiency rating (SAP 2009) Ensuring low energy consumption and
• Highly efficient and economical to run
• Compatible with aroTHERM air to water heat pump ErP rated A maximum efficiency
ErP rated A hybrid system
Making the perfect entry into renewable systems • Compact dimensions • Compatible with aroTHERM air to water heat pump
• Features electronically controlled low (720mm x 440mm x 338mm) hybrid system
energy pump For flexible siting options Making the perfect entry into renewable systems
Helping to reduce energy consumption
Below is a list of related Vaillant accessories, designed to help maximise your system to its full potential: Below is a list of related Vaillant accessories, designed to help maximise your system to its full potential:
ecoTEC combination boiler dimensions and key components ecoTEC combination boiler dimensions and key components
Combination boilers - ecoTEC plus 825 / 832 / 835 / 838 Combination boilers - ecoTEC exclusive 832 / 838
ecoTEC pro 24 / 28 / 30
Dimensions plus/pro: ecoTEC plus shown Dimensions:
14
5
6
1
7 13
4 8 2
9 3
3
10
11
2
12
1 4
13
12
14
5
11 6
15
7
19 10
8
18
Combi boilers
17 16
9
10 11
The TECHNICAL Brochure
Combination boilers - ecoTEC plus 825 / 832 / 835 / 838 / 938 Combination boilers - ecoTEC plus 825 / 832 / 835 / 838 / 938
Technical data Unit 825 832 835 838 938 Technical data Unit 825 832 835 838 938
0010018354 0010018354
Article number 0010018353 0010016540 0010018356 0010018357 Article number 0010018353 0010016540 0010018356 0010018357
0010018355 (LPG) 0010018355 (LPG)
Combi boilers
and 1013 mbar (based on Volume of water
m3h 2.7 3.4 3.8 4.2 l/h 830 1,049 1,307 1,230
hot water generation, if circulating (ΔT = 20k)
applicable), G20 Approx. Condensation
volume at 50°C l/h 2.0 2.5 3.1 2.9
Gas flow rate at 15oC
feed/30°C return
and 1013 mbar (based on
kg/h 2.0 2.5 2.8 3.1
hot water generation, if Remaining feed head
applicable), G31 of pump (at nominal
bar 0.25
circulation water
Approved flue type C13, C33, C43, C53 volume)
Minimum DHW flow
NOx class 5 l/min 2
rate
SEDBUK SAP seasonal DHW flow rate at 35°C
% 89.3 l/min 10.5 13 14.3 15.9
efficiency 2009 temperature rise
Maximum domestic
ErP rating Central Heating A bar 10
cold water pressure
ErP rating Hot Water A Minimum operational
bar 0.35
water pressure
Boiler dimensions (WxHxD) mm 440x720x338 440x720x372 440x720x406 440x720x600 Hot water discharge o
C 35 - 65
temperature range
Weight (boiler only) kg 36 37 38 43 60 Electricity supply
V-/Hz 230/50
voltage
Nominal heat output range
5.7 - 25.7 Internal fuse (slow)
of CH at 50oC flow/30oC kW 4.2 - 20.4 6.4 - 32.2 7.1 - 30.1 A 2
6.7 - 25.7 (LPG) main voltage
return
Nominal heat output range Minimum electrical
5.2 - 24.4 W 35 45 55
of CH at 80oC flow/60oC kW 3.8 - 19.3 5.8 - 30.4 6.4 - 28.6 power consumption
6.0 - 24.4 (LPG)
return
Maximum electrical
W 65 85 90 120 140
Maximum DHW output kW 25.4 31.8 35 38.7 power consumption
Standby electrical
Maximum DHW input kW 25.9 32.4 35.7 39.5 W <2 <3
power consumption
Protection class IP X 4D
12 13
The TECHNICAL Brochure
0010018495 0010018495
Article number 0010018494 0010016538 Article number 0010018494 0010016538
0010018496 (LPG) 0010018496 (LPG)
Inlet gas working pressure (G20, Mains water pressure required for
mbar 20 bar 0.8
natural gas) maximum flow rate
Combi boilers
l/h 813 1,049
20 K)
Gas flow rate at 15°C and 1013
mbar (based on hot water m3/h 2.5 2.9 3.2 Approx. Condensation volume at
l/h 1.9 2.5
generation, if applicable), G20 50°C feed/30°C return
Remaining feed head of
Gas flow rate at 15 °C and 1013 pump (at nominal circulation bar 0.25
mbar (based on hot water kg/h 1.9 2.2 2.4 water volume)
generation, if applicable), G31
Minimum DHW flow rate l/min 2
Approved flue type C13, C33, C43, C53
DHW flow rate at 35°C
l/min 9.6 11.1 12.3
NOx class 5 temperature rise
14 15
ecoTEC combination technical specifications ecoTEC combination technical specifications
Combination boilers - ecoTEC exclusive 832 / 838 Combination boilers - ecoTEC exclusive 832 / 838
Technical data Unit 832 838 Technical data Unit 832 838
Connections heating flow and return mm 22 Volume of water circulating (ΔT= 20 K) l/h 1,161 1,290
Connector expansion relief valve (minimum) mm 15 Approx. Condensation volume at 50°C feed/30°C
l/h 2.8 3.1
return
Flue size (concentric) mm 60/100
Remaining feed head of pump (at nominal
Condensate drain (minimum internal diameter drain) mm 10.7 14.4 bar 0.25
circulation water volume)
Inlet gas working pressure (G20, natural gas) mbar 20
Minimum DHW flow rate l/min 1.5
Inlet gas working pressure (G31, propane) mbar 37
DHW flow rate at 35°C temperature rise l/min 12.9 15.2
Gas flow rate at 15°C and 1013 mbar (based on
m3/h 3.4 4
hot water generation, if applicable), G20
Maximum domestic cold water pressure bar 10
Gas flow rate at 15 °C and 1013 mbar (based on hot water
kg/h 2.49 2.95 Minimum operational water pressure bar 0.35
generation, if applicable), G31
Combi boilers
Hot water discharge temperature range °C 35 - 65
Approved flue type C13, C33, C43, C53
Electrical supply voltage V-/ Hz 230/50
NOx class 5
Internal fuse (slow) main voltage A 2
SEDBUK SAP seasonal efficiency 2009 % 89.8 89.9
Mains water pressure required for maximum flow rate bar 0.5
16 17
The TECHNICAL Brochure
System boilers ecoTEC plus 612, 615, 618, 624, 630 and 637
The ecoTEC plus range of system boilers is available • Dedicated models available for LPG
in a wide range of output models including 12kW, Giving a solution for off-gas areas
15kW, 18kW, 24kW, 30kW and 37kW, meaning that
there is a suitable model for almost any home. The • Step by Step, full text installation wizard
stylish design and small dimensions also make it a For quicker, “first time right” set up and installation
perfect fit with any home.
A system boiler provides central heating and hot water via
System boilers
Key features and benefits:
a storage cylinder, which is filled from the mains and often
• Removable side panels
housed in an airing cupboard. For additional accessibility flexibility
ecoTEC system dimensions and flue clearances ecoTEC system boiler key components
ecoTEC plus 824 / 831 / 837 ecoTEC plus 612 / 615 / 618 / 624 / 630 / 637
Dimensions: ecoTEC pro 24 / 28
5 5
6 6
150mm, 60/100 flue
7 165mm, 60/100 flue (438 only) 7
9 9
3 3
10 10
11 11
2 2
12 12
1 1
13 13
14
14
15 15
19
System boilers
150mm
Clearances: 18 180mm (438 only)
16
150mm, 60/100 flue
17 16
165mm, 60/100 flue (438 only)
246mm, 80/125 flue (438 only)
Key:
1. Gas valve 9. Ignition electrode
2. Water pressure sensor 10. Fan
Legend Legend
3. Venturi with mass flow sensor 11. Automatic air vent
1 Gas valve 11 Automatic air vent 1 Gas valve 9 Ignition electrode
Boiler model Dimension B 4. Heat exchanger 12. Pressure gauge
2 Water pressure sensor 12 Pressure gauge 2 Water pressure sensor 10 Fan
5. Connection for the air/ flue gas duct 13. Internal pump
ecoTEC plus
3 Venturi with mass flow 13 Internal
612/615/618/624 pump
338mm 3 vessel
6. Expansion Venturi with mass flow 11 14. Bypass
Automatic air vent
valve
sensor sensor
150mm ecoTEC 14 Bypass
plus 630 valve
372mm 7. Air intake pipe 12 15. Expansion
Pressure gaugerelief valve
180mm (438 only) 4 Heat exchanger ecoTEC 15 Expansion 406mm
plus 637 relief valve 4 thermal
8. Compact Heat module
exchanger 13 16. Electronics
Internal pump box
20 5 Connection for the air/ 16 Electronics box 5 Connection for the air/ 14 Bypass valve 21
flue gas duct flue gas duct
17 Diverter valve with 15 Expansion relief valve
6 Expansion vessel bypass 6 Expansion vessel
16 Electronics box
The TECHNICAL Brochure
System boilers - ecoTEC plus 612 / 615 / 618 / 624 / 630 / 637 System boilers - ecoTEC plus 612 / 615 / 618 / 624 / 630 / 637
Technical data Unit 612 615 618 624 630 637 Technical data Unit 612 615 618 624 630 637
System boilers
main voltage
NOx class 5
Minimum electrical
W 35 45 55
SEDBUK SAP seasonal power consumption
% 89.0 89.1 89.3 89.4 89.2
efficiency 2009
Maximum electrical
W 50 55 65 70 80 115
ErP rating A power consumption
22 23
The TECHNICAL Brochure
Open vent boilers ecoTEC plus 412, 415, 418, 424, 430 and 438
* Please note, images used within this brochure are for illustrative purposes only.
The TECHNICAL Brochure
ecoTEC open vent dimensions ecoTEC open vent boiler key components
Dimensions:
5
Clearances:
2
7
ecoTEC open vent technical specifications ecoTEC open vent technical specifications
Open vent boilers - ecoTEC plus 412 / 415 / 418 / 424 / 430 / 438 Open vent boilers - ecoTEC plus 412 / 415 / 418 / 424 / 430 / 438
ecoTEC plus
ecoTEC plus
Technical data Unit 412 415 418 424 430 438
Technical data Unit 412 415 418 424 430 438
Article number 0010015669 0010015670 0010015671 0010015672 0010015673 0010002725
Heat exchanger type Article number 0010015669 0010015670 0010015671 0010015672 0010015673 0010002725
Aluminium Stainless Steel
(material)
Maximum working pressure
bar 0.3/3
Gas inlet connection mm 15 (pms)
Approx. Condensation
Connections heating flow volume at 50°C feed/30°C l/h 1.23 1.53 1.84 2.47 3.06 3.1
mm 22
and return return
Connector expansion relief
mm 15 Electrical supply voltage V-/ Hz 230/50
valve (minimum)
Flue size (concentric) mm 60/100 boiler connection (80/125 available with adaptor) External fuse (slow) main
A 3
voltage
Condensate drain (external 19 (int Standby electrical power
mm 21.5 W 2 <5
diameter) diameter) consumption
Inlet gas working pressure
mbar 20 Protection class IP X 4D
(G20, natural gas)
Maximum gas flow rate at
15°C and 1013 mbar (based
m3/h 1.9 2.7 3.2 3.8 4.06
on hot water generation, if
applicable), G20
NOx class 5
Adjustable flow
temperature (default °C 10 - 83 10 - 80 15 - 80
setting: 75°C)
28 29
ecoTEC domestic boiler flue tech summary ecoTEC domestic boiler flue tech summary
Flue solutions
heavy snowfall.
of a light well due to the build up of combustion
P 25mm from vertical drain pipes and soil pipes.
products.
200mm below eaves and 75mm below gutters,
Q
pipe and drains.
• Dimensions from a flue terminal to a fanned
air inlet to be determined by the ventilation
equipment manufacturer.
30 31
Vertical flue options Notes:
3 4 5
The overall maximum
The overall
Notes:
not be maximum
flue length
exceeded flue length
must 3 4 5
The overall maximum flue length must not beThe overall maximum flue length
exceeded
Notes: must notmust
be exceeded
Notes: must not be exceeded
2 Horizontal sections have a continuous fall of
The overall maximum flue length Horizontal
must notThe overall maximum flue length
be exceeded
at least 2.5°sections must have
(44mm/metre) a continuous
back fall of
to the boiler
The TECHNICAL Brochure must not be exceeded Horizontal sections must have a continuous fallatofleast 2.5°Horizontal sections
(44mm/metre) must
back have
to the a continuous fall of
boiler
Flue solutions
Vertical flue options 6 at least 2.5° (44mm/metre) back to the boiler at least 2.5° (44mm/metre) back to the boiler
8 9 10 1 Vertical flue options 7 13 3 4 5
1
1
8 9 10 1
Vertical flue options8 9 10
Vertical flue options 7 13 1 7 13 3 4 5
3
3 7 138 9 10 7 13 2 6 Notes: 6
7 13 7 13 7 13 7 13
3
3
7 13 The overall maximum flue length
Flue solutions 4 5 6
4 5 6 4 5 6
4 5 6
1
1
7 13 7 13 must not be exceeded
303933 303209 11 Black terminal kit for horizontal air/flue duct 303934 – 11 Telescopic air/flue duct extension 303906 –
32 12 Standard Horizontal air/flue duct with elbow and terminal 303933 303209 12 Flue terminal for ridge tile 303982 – 33
34
Combi boiler with timeSWITCH 150, VRT 50, single zone - schematic
The TECHNICAL Brochure
Combi boiler with timeSWITCH 150, VRT 50, single zone - wiring
Schematics and
35
wiring diagrams
36
Combi boiler with timeSWITCH 160, VRT 15, single zone - schematic
The TECHNICAL Brochure
combi boiler with timeSWITCH 160, VRT 15, single zone - wiring
Schematics and
37
wiring diagrams
38
Combi boiler with VRT 350, single zone - schematic
The TECHNICAL Brochure
Schematics and
39
wiring diagrams
40
Combi boiler with VRC 470, single zone - schematic
The TECHNICAL Brochure
Schematics and
41
wiring diagrams
42
Combi boiler with two VRT 350, VR 66, 2 zone - schematic
The TECHNICAL Brochure
Schematics and
43
wiring diagrams
44
System boiler with VRC 470, VR61, VR 81, 2 zone - schematic
The TECHNICAL Brochure
Schematics and
45
wiring diagrams
The TECHNICAL Brochure
unvented cylinders
UniSTOR
uniSTOR is a range of six high grade stainless steel unvented
cylinders from Vaillant. Finished with stylish casing, they are
available in a range of sizes from 120 litres to 310 litres.
The uniSTOR stainless steel cylinder range can be Key features and benefits:
used together with any Vaillant system and open uniSTOR stainless steel unvented cylinder 120 155 180 210 260 310
• uniSTOR cylinders operate using a mains water Article number 0010010900 0010010901 0010010902 0010010903 0010010904 0010010905
vent boiler (or any existing system or open vent
pressure supply and do not require a feed from
boiler). They work in perfection when used with External case height (mm) 1001 1191 1371 1593 1843 2153
a cold water storage tank
the ecoTEC range of system boilers, where they Diameter (mm) 554.5 554.5 554.5 554.5 554.5 554.5
can make full use of Vaillant’s intelligent • All necessary cold and hot water controls and a Approx weight when empty (Kg) 26 29 32 36 41 46
ebus temperature sensing controls as part 2-port valve for control of domestic hot water
of Vaillant’s Total System Solution. are supplied
• All uniSTOR cylinders are backed by a full 2
year guarantee as well as a 25 year guarantee
on the cylinder shell
46 47
• Complete with G3 kit and expansion vessel
uniSTOR technical specification
uniSTOR 120 / 155 / 180 / 210 / 260 / 310L uniSTOR 120 / 155 / 180 / 210 / 260 / 310L
Technical data Unit 120 155 180 210 260 310 Technical data Unit 120 155 180 210 260 310
Article number 0010010900 0010010901 0010010902 0010010903 0010010904 0010010905 Article number 0010010900 0010010901 0010010902 0010010903 0010010904 0010010905
Total capacity l 120 155 180 210 260 310 Height mm 1001 1191 1371 1593 1843 2153
Actual capacity l 119.2 149.1 176.6 211.2 250.3 298.5 Height with hot water draw off l 1033 1223 1403 1625 1875 2185
Hot water capacity l 1040 1367 1664 2039 2475 2705 Topple measure mm 1138 1308 1473 1680 1918 2217
unvented cylinders
Maximum supply pressure
MPa (bar) 1.2 (12) 1.2 (12)
to pressure reducing valve Depth mm 633 633
UniSTOR
Rated pressure Net weight kg 26 29 32 36 41 46
MPa (bar) 0.7 (7) 0.7 (7)
of cylinder
Weight (full) kg 145 177.8 209 248 291 345
Maximum operating
MPa (bar) 0.35 (3.5) 0.35 (3.5) Connections
pressure of heating coil
Cold water inlet 22mm unprofiled pipe (crimp joints) 22mm unprofiled pipe (crimp joints)
Pressure reducing valve MPa (bar) 0.35 (3.5) 0.35 (3.5)
Hot water draw off 22mm unprofiled pipe (crimp joints) 22mm unprofiled pipe (crimp joints)
Expansion relief valve MPa (bar) 0.6 (6.0) 0.6 (6.0)
Pressure-controlled cold water
22mm unprofiled pipe (crimp joints) 22mm unprofiled pipe (crimp joints)
Temperature and pressure °C 90 90 inlet
relief valve MPa (bar) 0.7 (7) 0.7 (7)
Secondary return 15mm unprofiled pipe (crimp joints) 15mm unprofiled pipe (crimp joints)
Charge pressure of hot Primary heater flow 22mm unprofiled pipe (crimp joints) 22mm unprofiled pipe (crimp joints)
MPa (bar) 0.4 (4) 0.4 (4)
water expansion vessel
Primary heater return 22mm unprofiled pipe (crimp joints) 22mm unprofiled pipe (crimp joints)
Maximum temperature of
°C 85 85 Primary heating circuit
heating circuit mm 8 8
immersion sleeve size
Maximum temperature of Electrical connections
°C 85 85
potable hot water
Immersion heater (according
2.7 kW, 230 V, 50 Hz 2.7 kW, 230 V, 50 Hz
Standing heat loss kW/24 h 1.26 1.53 1.66 1.89 2.07 2.26 to ENBS 60335)
48 49
The TECHNICAL Brochure
Weather compensating controls VRC 470f Intelligent room compensators VRT 350 and VRT 350f
Weather compensating
controls
Our intelligent compensating controls give you even You have a choice of what kind of controls you have to
more control over your heating system so that you can manage your boiler. The more sophisticated the control,
ensure that it’s working as efficiently as possible. the more control you have over your heating system.
The VRC 470f is a unique wireless weather Key features and benefits: Our intelligent room compensating controls allow Key features and benefits:
compensating control. Constantly monitoring the you to fine tune your heating system, giving you
• Intelligent time and temperature control for central • Intelligent time and temperature control of
temperature outside, it intelligently adapts to even more control. These controls allow you to
heating and domestic hot water heating and domestic hot water
optimise the boilers output for maximum efficiency turn your system on or off at different times of
and home comfort. • Classed as enhanced load compensator adding 3% • New attractive, easy-to-use design with blue
the day, and continually monitors and adapts to
to the SEDBUK efficiency rating backlit display
Featuring a backlit plain text display with a single give you the desired room temperature. The blue
• Cylinder boost function backlit screen and plain text display make the VRT • Automatic summer/winter time change over
rotary knob which, together with numbered screens,
make navigation easy. It has time and temperature • Holiday function 350 and VRT 350f easy and clear to understand. • Five operation modes: automatic, summer,
controls for heating and hot water channels and an • Includes a service reminder function Only two push buttons and one rotary knob are comfort, set-back and system off
additional timed channel for a circulation pump. • Automatic summer/winter time change over needed to select and change data. • Two temperature setting levels: desired and
set-back temperatures
Programming for 7 day, 5 day/2 day or 24 hours, • Wireless control Plus, when you go on holiday the VRT 350 and
operation is possible with 3 different time windows VRT 350f have a holiday set-back function, which • Cylinder boost option
• Supplied with outdoor sensor which monitors
per day with one comfort and setback temperature the outdoor temperature reduces the temperature in your property and • Wireless control (VRT 350f only)
for all time periods. heats it up before you come back home.
• Receiver can be fascia or wall-mounted
Additional features include; set-back temperature,
heating and hot water advance, automatic summer
to winter changeover, holiday mode, and optimum
start/stop. With additional accessories the VRC 470f
can be used to control two heating zones and hot
water circuits. Simple two-wire low voltage eBUS
50 connections make installing the VRC 470f easy to fit 51
into the boiler fascia for true plug and play flexibility.
The TECHNICAL Brochure
timeSWITCH 150 timeSWITCH 160 Room thermostat VRT 15 Room thermostat VR81
timeSWITCH controls
Our basic boiler control allows you to adjust the The timeSWITCH 160 can be used with all Vaillant This easy-to-use, simple room thermostat works The display of the VR 81 shows the current room
heating programme by choosing when you would like ecoTEC boilers and mounts directly into the front with the timeSWITCH 160. This thermostat is temperature. With the ‘turn and click’ handling, the
compatible with all ecoTEC boiler models.
your system to switch on or off, and how long you of the boiler without the need for any wiring. desired room temperature can easily be changed.
would like it to operate for. This timer gives you control of your central heating Key features and benefits: The remote control unit VR 81 has two possible
and domestic hot water with a timed programming • Simple 230V analogue room thermostat functions: In a single-zone heating system, the VR 81
The timeSWITCH 150 is compatible with all Vaillant
function. With the added option of up to three • Compatible with timeSWITCH 160 will be installed on the wall inside a living area while
ecoTEC combi boilers and plugs directly into the
programme times per day, seven days a week, • Easy to use the weather compensator VRC 470 remains in the
boiler without the need for any wiring. This timer
for added flexibility and comfort. boiler fascia. When used with a two zone heating
provides easy-to-use, basic timing for your central
Room thermostat VRT 50 system the VR 81 becomes the room thermostat
heating needs. Key features and benefits: This easy-to-use, intelligent VRT 50 digital for the second heating zone while the weather
• Two channel digital timer room thermostat shows the current room compensator VRC 470 or VRC 470f would act
Key features and benefits: temperature and can be used with Vaillant
• Mounts directly into boiler fascia as a room thermostat for the first heating zone.
• Single channel analogue timer ecoTEC plus combi boilers and the timeSWITCH
• Controls heating and domestic hot water 150 central heating timer. For this installation an additional VR 61 wiring
• Mounts directly into boiler fascia centre is required.
timed programmes The thermostat can be set to intelligent control,
• 24-hour timer for central heating
• Holiday function—days away from home which provides greater efficiency and a more
• Compatible with all Vaillant combi boilers comfortable room temperature.
scheduling
• Compatible with VRT 50 digital room thermostat Key features and benefits:
• Compatible with all Vaillant system and
heat-only appliances • Compatible with timeSWITCH 150
52 53
• Compatible with the VRT 15 room thermostat • Easy to use
54
Controls compatibility finder
This guide will assist you in selecting the correct control for your heating system.
Simply select which boiler type you have, and follow the columns on the table to show you the controls compatible with your system.
Wired Yes No ü ü
Wired Yes No ü ü
No
Wired No No ü
1 Wireless No No ü
Wired Yes No ü ü
Combi
Yes Wired No No ü
Wireless No No ü
No Wired No No ü ü
2 Wired No No ü ü ü
Yes
Wireless No No ü ü ü
Wired Yes No ü ü ü
Wired Yes Yes ü ü ü ü
Wired No No ü ü
No
Wired No Yes ü ü ü
Wireless No No ü ü
Wireless No Yes ü ü ü
1
Wired Yes No ü ü ü
System Wired Yes Yes ü ü ü ü
or
Wired No No ü ü
open Yes
vent Wired No Yes ü ü ü
Wireless No No ü ü
Wireless No Yes ü ü ü
No Wired No No ü ü
Wired No No ü ü ü
2 Wired No Yes ü ü ü ü
Yes
Wireless No No ü ü ü
Wireless No Yes ü ü ü ü
Vaillant Advance
55
Vaillant Advance
The TECHNICAL Brochure
Renewable calculator
This helpful tool is designed to help you
discover how much money and CO2 you could
save by installing a Vaillant renewable heating
or hot water system in your home.
Service
Go to www.vaillantrenewables.co.uk
Vaillant Training
Vaillant Training
Industry leading training designed for Dedicated state of the art Centres of Simpler, smarter, state of the art e-learning
industry leading engineers. Excellence. Experience from Vaillant.
With a team of fully qualified industry experts, our Located in Glasgow, Elland (near Leeds), Belper a new Here at Vaillant, we know that time is money. That is
training courses have been designed and tailored (near Derby), Cambridge, Farnborough, Bristol and age of why our new blended approach to training combines
to keep you one step ahead of the ever-developing Maidstone you can rest assured there is a centre training convenient online tuition with expert hands-on
world of heating and hot water technologies and never far away from where you are. Our centres innovation training at our cutting edge nationwide Centres of
Glasgow
industry regulations. have been developed and designed with you in today. Excellence. Proven to be 60% quicker and twice as
mind, offering spacious facilities, a comfortable effective*, Vaillant training means you can be the
We offer the full package of courses for all levels
and superbly equipped training environment, with expert engineer without compromising time with
within the industry. From a full day getting hands
plenty of opportunities for hands on experience and your customers. Experience the new
on with the ecoTEC range of domestic boilers to
product familiarisation. age of training today innovation today at
our aroTHERM air to water heat pumps – we have Elland (Leeds) Belper (Derby)
www.vaillant.co.uk
a course for you.
Cambridge
Bristol
Maidstone
58 Farnborough 59
* Twice as effective and 60% quicker when combined with traditional practical training
The TECHNICAL Brochure
You will find the relevant article numbers referenced throughout this brochure. However for ease of ordering,
Passive Flue Gas Heat Recovery Device Article Number
all ecoTEC components are summarised below:
recoFLUE PFGHRD 0020152033
High efficiency combination boilers Article Number
ecoTEC plus 825 0010018353 High efficiency flues - 100mm
ecoTEC plus 832 0010018354 Standard horizontal air/flue duct with elbow and terminal 303933
Vertical air flue duct and terminal 0020065937
ecoTEC plus 832 LPG 0010018355
Flat roof penetration collar 009056
ecoTEC plus 835 0010016540
Pitched roof adjustable roof tile 009076
ecoTEC plus 838 0010018356
Flexible roof seal 303980
ecoTEC plus 938 0010018375
Horizontal telescopic air/flue duct with elbow and terminal 303936
ecoTEC pro 24 0010018494
87° elbow 303910
ecoTEC pro 28 0010018495
45° bends (x 2) 303911
ecoTEC pro 28 LPG 0010018496
Air/flue duct extension (470mm) 303902
ecoTEC pro 30 0010016538
Air/flue duct extension (970mm) 303903
Order numbers
ecoTEC exclusive 832 0010002668
Air/flue duct extension (1970mm) 303905
ecoTEC exclusive 838 0010002669
Air/flue duct extension (4000mm) 0020138174
High efficiency system boilers Telescopic air/flue duct extension 303906
ecoTEC plus 612 0010018531 Telescopic offset 303919
ecoTEC plus 615 0010018532 Sliding sleeve 303915
ecoTEC plus 618 0010018533 Flue support clips (x 5) 303821
ecoTEC plus 618 LPG 0010018534 Adjustable flue support (x 3) 303935
ecoTEC plus 624 0010018535 Black terminal kit for horizontal air/flue duct 303934
ecoTEC plus 630 0010018536 Plume deflector horizontal (black) 0020060584
ecoTEC plus 630 LPG 0010018537 Plume deflector horizontal (white) 0020060585
ecoTEC plus 637 0010018538 Flue terminal for ridge tile 303982
ecoTEC plus 418 0010015671 90° elbow for variable termination kit - black 303944
ecoTEC plus 424 0010015672 45° bend for variable termination kit - black (2 pieces) 303945
Variable termination kit - white 303946
ecoTEC plus 430 0010015673
Extension pipe for variable termination kit - white (1m) 303947
ecoTEC plus 438 0010002725
90° elbow for variable termination kit - white 303949
Single coil cylinders 45° bend for variable termination kit - white (2 pieces) 303948
uniSTOR 120 0010010900
High efficiency flues - 125mm
uniSTOR 155 0010010901
Optional boiler flue adaptor (100mmø to 125mmø) 303926
uniSTOR 180 0010010902
Optional boiler flue adaptor (100mmø to 125mmø) - bayonet 0020147469
uniSTOR 210 0010010903
Horizontal air/flue duct with elbow and terminal 303209
uniSTOR 260 0010010904
Vertical air/flue duct and terminal 303200
uniSTOR 310 0010010905
87° elbow 303210
Controls Two 45° bends 303211
timeSWITCH 150 0020116882 Air/flue duct extension (470mm) 303202
timeSWITCH 160 0020124498 Air/flue duct extension (970mm) 303203
VRT 15 306777 Air/flue duct extension (1970mm) 303205
VRT 50 0020018265 Sliding sleeve 303215
VRT 350 0020124475 Flue support clips (pack of 5) 303616
VRT 350f 0020124482
Accessories
VRC 470 0020108130
Spacing frame accessory 308650
VRC 470f 0020108137
Boiler security bracket 2370109
VR 81 0020129323
Pipe cover accessory 2378099
VR 66 0020135785
ecoLEVEL condensate pump 0020030797
VR 40 0020017744
Remote PRV mounting kit 0020094185
VR 61 0020139853
60 61
VR 68 0020139859
VR32 0020139895
The TECHNICAL Brochure
Notes Notes
62 63
Training Enquiries After Sales
For information on training courses For support after your boiler has
and centres in your area: been installed, whether you would
Telephone: 0845 601 8885 like to book a service or are in need
Email: training@vaillant.co.uk of technical advice, our operators are
available 7 days a week, 364 days a
year.
Telephone: 0330 100 3143
64
VAECOTEC | V3 August 16