l u t i o n s

Total System S o

Tube Ventilation System


Tube ventilation is a unique method that gently introduces
fresh air into enclosed environments without introducing
damaging cold drafts. By creating environments that are
infused with fresh air, it is ideal for calf barns and other
animal rearing facilities, including poultry and swine as well
as greenhouses, commercial buildings and industrial settings.

J&D Manufacturing customizes each Tube Ventilation


System for your specific application.

Call today to discuss your ventilation requirements.

d
System Verifie nce!
ma
Features Perfor
• Fan, weather hood and tube
be

• Positive pressure system

• Provides gentle fresh air induction without


creating a draft

• Reduces airborne bacterial counts and respiratory


disease when used as a fresh air inlet
Tube
• May also provide heat distribution and air
recirculation if mounted away from the end wall

Fan
Features
• 18-gauge galvanized housing with formed channel
for securing the vent tube to the fan

• Corrosion resistant guards


Tube Fan
• Poly or aluminum propellers

• Includes cable ties for securing the tube to the fan

• Totally enclosed, maintenance-free, direct drive,


high efficiency motors have completely sealed ball
bearings, UL and CUL recognized and are covered Tube Fan
by a Two Year Warranty Weather Hood

Due to our continual effort to provide the best products available and
nd adhere to market conditions; literature
literature, products
products, prices and availability are subject to change without notice.
notice

www.jdmfg.com 6200 Hwy 12 P:1-800-998-2398


Page: 1205
jdmfg@jdmfg.com Eau Claire, WI 54701 F:1-888-972-4454 .
Rev: 08 16
l u t i o n s
Total System S o

Tube Ventilation System


Tube Fans with Tube Fan Weather Hoods
- Tube is ordered separately, see Ventilation Tube page for selectable options
- Test performance data is on complete system (fan, weather hood, and tube)
With Without Minimum With Weather
Weather Hood Weather Hood Tube Hood System
Part# Part# Size Diameter HP Volts AmpsNP Hz˘ Ph Spd RPM CFM @ 0.18 SP Prop Test #
__________________________________________________________________________________________________________________________
12”
__________________________________________________________________________________________________________________________
VTGW12P12A VTG12P12A 12” 13” 1/
115/230 3.8/1.9 60 1 1 1,700 1,200 8-Ply 20160128-03
__________________________________________________________________________________________________________________________
3

16”
__________________________________________________________________________________________________________________________
VTGW16P19A VTG16P19A 16” 17” 1/
115/230 4.8/2.4 60 1 1 1,725 1,900 4-Ply 20151228-01
__________________________________________________________________________________________________________________________
2

VTGW16P22A VTG16P22A 16” 17” 1/


115/230 4.8/2.4 60 1 1 1,725 2,200 3-Ply 20151228-02
__________________________________________________________________________________________________________________________
2

VTGW16P27A VTG16P27A 16” 17” 1/


115/230 4.8/2.4 60 1 1 1,725 2,700 6-Ply 20151228-03
__________________________________________________________________________________________________________________________
2

20”
__________________________________________________________________________________________________________________________
VTGW20P33A VTG20P33A 20” 22” 1/
115/230 4.8/2.4 60 1 1 1,725 3,300 2-Ply 20160126-04
__________________________________________________________________________________________________________________________
2

VTGW20P35A VTG20P35A 20” 22” 1/


115/230 4.8/2.4 60 1 1 1,725 3,500 3-Ply 20160126-03
__________________________________________________________________________________________________________________________
2

VTGW20P39A VTG20P39A 20” 22” 1/


115/230 4.8/2.4 60 1 1 1,725 3,900 4-Ply 20160126-02
__________________________________________________________________________________________________________________________
2

24” - Single Phase


__________________________________________________________________________________________________________________________
VTGW24P41A VTG24P41A 24” 25” 1/
115/230 4.8/2.4 60 1 1 1,725 4,100 3-Ply 20160125-02
__________________________________________________________________________________________________________________________
2

VTGW24A45A VTG24A45A 24” 25” 1/


115/230 4.8/2.4 60 1 1 1,725 4,500 3-Alm 20160127-02
__________________________________________________________________________________________________________________________
2

VTGW24P50A VTG24P50A 24” 25” 1 115/230 8.6/4.3 60 1 1 1,725 5,000 4-Ply 20160122-04
__________________________________________________________________________________________________________________________
VTGW24P56A VTG24P56A 24” 25” 1 115/230 8.6/4.3 60 1 1 1,725 5,600 4-Ply 20160122-03
__________________________________________________________________________________________________________________________
VTGW24P61A VTG24P61A 24” 25” 1 115/230 8.6/4.3 60 1 1 1,725 6,100 4-Ply 20160122-02
__________________________________________________________________________________________________________________________
VTGW24P65A VTG24P65A 24” 25” 1 115/230 8.6/4.3 60 1 1 1,725 6,500 4-Ply 20160129-01
__________________________________________________________________________________________________________________________
VTGW24P72A VTG24P72A 24” 25” 1 115/230 8.6/4.3 60 1 1 1,725 7,200 4-Ply 20160122-01
__________________________________________________________________________________________________________________________
24” - Three Phase
__________________________________________________________________________________________________________________________
VTGW24P44A-3 VTG24P44A-3 24” 25” 1 230/460 3.2/1.6 60 3 1 1,725 4,400 4-Ply 20160811-01
__________________________________________________________________________________________________________________________
VTGW24P47A-3 VTG24P47A-3 24” 25” 1 230/460 3.2/1.6 60 3 1 1,725 4,700 4-Ply 20160805-02
__________________________________________________________________________________________________________________________
VTGW24P53A-3 VTG24P53A-3 24” 25” 1 230/460 3.2/1.6 60 3 1 1,725 5,300 4-Ply 20160805-01
__________________________________________________________________________________________________________________________
VTGW24P60A-3 VTG24P60A-3 24” 25” 1 230/460 3.2/1.6 60 3 1 1,725 6,000 4-Ply 20160804-03
__________________________________________________________________________________________________________________________
VTGW24P64A-3 VTG24P64A-3 24” 25” 1 230/460 3.2/1.6 60 3 1 1,725 6,400 4-Ply 20160804-02
__________________________________________________________________________________________________________________________
VTGW24P72A-3 VTG24P72A-3 24” 25” 1 230/460 3.2/1.6 60 3 1 1,725 7,200 4-Ply 20160804-01
__________________________________________________________________________________________________________________________
NP Amp information as documented on motor name plate Weather Hood
Fan Fan Rough must be mounted
˘ For 50 Hz compatibility data please contact J&D Manufacturing __________________________
Size Opening centered over fan
Bold red text is data based on testing performed by Don’t fo __________________________
rget to 12” 14”W x 14”H 27”W x 26”H
an accredited lab using ANSI/AMCA Standard 210-07 order yo __________________________
16” 18”W x 18”H 27”W x 26”H
OSHA requires this fan to be mounted 7’ above the floor ur tube! __________________________
20” 22½”W x 22½”H 45”W x 31”H
__________________________
24” 26”W x 26”H 45”W x 31”H

Ventilation Tube Support Kits


Part# Description
___________________________________________________________
Cable Kits
___________________________________________________________
HK162 50’ Cable Kit, Ventilation Tube Support, w/Assembly Hdwr
___________________________________________________________
HK163 100’ Cable Kit, Ventilation Tube Support, w/Assembly Hdwr
___________________________________________________________
HK164 150’ Cable Kit, Ventilation Tube Support, w/Assembly Hdwr
___________________________________________________________
HK165 200’ Cable Kit, Ventilation Tube Support, w/Assembly Hdwr
___________________________________________________________
Tools & Rings
___________________________________________________________ PP10744
PP10744 Pliers, Manual Hog Ring, with Spring Loaded Magazine
___________________________________________________________ 50’, 100’, 150’, & 200’ Hog Ring Pliers for
HD10597 Hog Rings, Aluminum Blunt Point , 9 Gauge (Qty 25) Ventilation Tube Support Cable Kits Connecting Tube to Cable
For additional accessories to compliment your Tube Ventilation System refer to the following catalog sections, “Environmental
Controls” for a complete line of J&D Controls and “Inlets” for a selection of J&D Aluminum Intake Power Shutters.

Due to our continual effort to provide the best products available and adhere to market conditions; literature, products, prices and availability are subject to change without notice.

www.jdmfg.com 6200 Hwy 12 P:1-800-998-2398


Page: 1206
jdmfg@jdmfg.com Eau Claire, WI 54701 F:1-888-972-4454 .
Rev: 08 16
l u t i on s
Total Syste m S o

Ventilation Tubes

J&D’s reinforced poly ventilation tubes have


the quality and options to meet your needs.
Whether completing your new tube system,
replacing a worn or damaged tube, or just
updating your airflow pattern, J&D can help.
Ventilation tubes are individually built for
each application to provide proper airflow.

Call today to discuss your


ventilation requirements.

Features
• Made from 4oz reinforced poly material
aterial

• Hole spacing and location built


specifically for your application

duct at
• Standard tubes offer a great product
an even better price

ss
• Custom tubes offer nearly limitless
configurations for those hard to
efficiently ventilate spaces

• Reinforced grommeted hanger/s enables


ck
the use of ring connectors for quick
installation and easy removal for
cleaning and sanitizing
— grommets are spaced 2’ on center

st products available and adhere to market conditions; literature, products, prices and availability are subject to change without notice.
Due to our continual effort to provide the best

www.jdmfg.com 62000 Hwy 12 P:1-800-998-2398


Page: 1207
Pa
jdmfg@jdmfg.com Eau Claire,
ire, WI 54701 F:1-888-972-4454 .
Rev: 12 16
l u t i on s
Total Syste m S o

Ordering Ventilation Tubes


Ventilation Tube Step 1: Select tube diameter
Ordering Worksheet Tube
Component Units of Diameter
Descriptions Measurement
__________________________ inches
Tube
__________________________
Step 1 Diameter Inches
__________________________
Step 2 Length Feet/Inches
__________________________
Step 3 Hanger/s 1 or 2
__________________________
Row #1
__________________________
Step 4 Hole Size Inches
__________________________
Step 2: Select tube length
Step 5 Hole Location* Clock Position
__________________________
Step 6 Hole Spacing * Inches
__________________________ Tube
Row #2
__________________________ Length
Step 4 Hole Size Inches
__________________________ feet/inches
Step 5 Hole Location* Clock Position
__________________________
Step 6 Hole Spacing * Inches
__________________________
Row #3
__________________________
Step 4 Hole Size Inches
__________________________
Step 5 Hole Location* Clock Position
__________________________
Step 6 Hole Spacing * Inches
Step 3: Select single or double hanger
__________________________
Row #4
__________________________
Step 4 Hole Size Inches
__________________________
Step 5 Hole Location* Clock Position
__________________________ Single Double
Step 6 Hole Spacing * Inches
__________________________ Hanger Hanger
Tube Tube
* All hole locations and spacing must
be given as on-center measurements

Qualifying for Standard Status Step 4: Select hole size for row of holes
Tube must meet the following specifications ½”, ¾”, 1”, 1¼”, 1½”, 1¾”, 2”, 2¼”, 2½”, 2¾”, 3”, or a custom size
• Tube must be Single Hanger
Step 5: Select clock position for row of holes*
• Tube diameter must be between
8” and 44” and in whole inches 11 12 1
10 Clock 2
• Rows must be on full quarter hour Positions
increment clock positions 9 as viewed 3
• Each series of holes in a single row 8 from fan 4
must be the same size and have the Standard Tube Row 7
6
5
same spacing between holes Spacing Minimums
Row Step 6: Select hole spacing for row of holes*
• No more than 2 rows per tube may Separation
have the same size hole Tube Minimum
• Rows require a minimum spacing Diameter hr:min
_______________
between rows, using your chosen 8” 2:00
_______________ Hole Spacing
9” - 10” 1:45
_______________
tube diameter refer to the table to
11” - 12” 1:30
_______________
the right to evaluate compliance for 13” - 15” 1:15 Row
_______________
standard vs custom placement 16” - 20” 1:00
_______________
• Hole sizes can be any ¼” increment 21” - 30” 0:45
_______________
from ½” up to 3” 31” - 44” 0:30 Step 7: Repeat steps 4 through 6 for each additional row of holes
Due to our continual effort to provide the best products available and adhere to market conditions; literature, products, prices and availability are subject to change without notice.

www.jdmfg.com 6200 Hwy 12 P:1-800-998-2398


Page: 1208
jdmfg@jdmfg.com Eau Claire, WI 54701 F:1-888-972-4454 .
Rev: 12 16