Quiz Compression Member

You might also like

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 3

QUIZ STRUCTURAL DESIGN

Name : ________________ NPM : _____________

1. A 24ft of length W14x90 of the 50 ksi is used as a column with a


support against weak axis buckling at point C (assumed as pin) as A
shown in Figure. Determine :
a. Effective length due to buckling to x and y direction 12ft
b. To which direction the column buckles and what is the type of
buckling? (elastic or inelastic buckling) C
c. Critical stress (Fcr) of column
d. Check whether the column is adequate if the 1200kip (5337kN) 28ft
factored load applied.
Lateral support at the
W14x90 A=26.5in2=17096.7mm2 rx= 6.14in=155.9mm ry=3.70in=94mm weakness axis y
W8x24 A= 7.08in2 Ix=82.8in4 Iy=18.3in4 rx= 3.42in ry=1.61in 16ft
W14x90
W16x57 A= 16.8in2 Ix=758in4 Iy=43.1in4 rx= 6.72in ry=1.60in
E = 29.000ksi B
1 kip = 4.447kN 1 ksi = 6.9 MPa 1 inch=25.4mm 1ft=12in=304.8mm

F C
2. The frame in this Figure is use W8x24 as
W 8x24

W 8x24
a column and W16x57 of the 50 ksi as
10ft girder/beam. Assume that the column is
oriented in such a way that major axis
bending occurs in the plane of the frame and
W16x5 W16x5 the columns are braced at each story level
7 7 B for out-of-plane buckling.
W 8x24

W 8x24

E
a. Calculate the effective length factor
for the column AB & EF
15ft b. To which direction both columns
buckles and what is the type of
D buckling? (elastic/ inelastic)
A c. Determine the Nominal design
20ft 25ft strength of column EF.
QUIZ PERANCANGAN STRUKTUR A
Nama : ________________ NPM : _____________

1. Kolom W14x90 (Fy=50ksi) sepanjang 24ft dengan perletakan jepit dan


sendi seperti pada Gambar. Kolom ini pada sumbu lemah mendapatkan A
support arah lateral (asumsi sendi) pada jarak 12ft dari atas.
a. Hitung panjang efektif/tekuk pada arah sumbu x dan y 12ft
b. Cek pada arah mana tekuk terjadi dan jenis tekuk (elastic/inelastic)
c. Hitung Kekuatan nominal kolom (Pn) C
d. Cek apakah kolom ini kuat terhadap gaya Pu=1200kip (5337kN)
28ft
2 2
W14x90 A=26.5in =17096.7mm rx= 6.14in=155.9mm ry=3.70in=94mm
W8x24 A= 7.08in2 Ix=82.8in4 Iy=18.3in4 rx= 3.42in ry=1.61in Lateral support at the
W16x57 A= 16.8in2 Ix=758in4 Iy=43.1in4 rx= 6.72in ry=1.60in weakness axis y
E = 29.000ksi 16ft
W14x90
1 kip = 4.447kN 1 ksi = 6.9 MPa 1 inch=25.4mm 1ft=12in=304.8mm
B
F C
W 8x24

W 8x24 10ft 2. Portal disamping menggunakan W8x24


sebagai kolom dan W16x57 sebagai balok
(Fy=50 ksi). Posisi kolom pada portal ini
W16x57 W16x57 diletakkan pada arah sumbu kuat. Diasumsikan,
4 B
W 8x24

W 8x24

E pada arah sumbu lemah portal diberi bracing


pada setiap lantai.
a. Hitung panjang efektif kolom AB & EF
15ft b. Cek pada arah mana tekuk terjadi dan
jenis tekuk (elastic/inelastic) pada kedua
D kolom
A c. Hitung kekuatan nominal dari kolom
20ft 25ft EF.
QUIZ PERANCANGAN STRUKTUR B
Nama : ________________ NPM : _____________

1. Kolom W14x90 (Fy=50ksi) sepanjang 30ft dengan perletakan jepit dan


sendi seperti pada Gambar. Kolom ini pada sumbu lemah mendapatkan A
support arah lateral (asumsi sendi) pada jarak 14ft dari bawah.
a. Hitung panjang efektif/tekuk pada arah sumbu x dan y 16ft
b. Cek pada arah mana tekuk terjadi dan jenis tekuk (elastic/inelastic)
c. Hitung Kekuatan nominal kolom (Pn) C
d. Cek apakah kolom ini kuat terhadap gaya Pu=1200kip (5337kN)
30ft
2 2
W14x90 A=26.5in =17096.7mm rx= 6.14in=155.9mm ry=3.70in=94mm
W8x24 A= 7.08in2 Ix=82.8in4 Iy=18.3in4 rx= 3.42in ry=1.61in Lateral support at the
W16x57 A= 16.8in2 Ix=758in4 Iy=43.1in4 rx= 6.72in ry=1.60in weakness axis y
E = 29.000ksi 14ft
W14x90
1 kip = 4.447kN 1 ksi = 6.9 MPa 1 inch=25.4mm 1ft=12in=304.8mm
B
F C
W 8x24

W 8x24 10ft 2. Portal disamping menggunakan W8x24


sebagai kolom dan W16x57 sebagai balok
(Fy=50 ksi). Posisi kolom pada portal ini
W16x57 W16x57 diletakkan pada arah sumbu kuat. Diasumsikan,
4 B
W 8x24

W 8x24

E pada arah sumbu lemah portal diberi bracing


pada setiap lantai.
a. Hitung panjang efektif kolom DE & BC
15ft b. Cek pada arah mana tekuk terjadi dan
jenis tekuk (elastic/inelastic) pada kedua
D kolom
A c. Hitung kekuatan nominal dari kolom
20ft 25ft BC. (Pn)