1. Background of Information
There are few reports that operator feels a slight noise and or vibration at the moment arm
pulled vertical while arm-in independent or arm-boom simultaneous operation. And also
reported that this phenomenon is generally identified in the work on the soft ground
relatively. This sound is caused by arm-in recirculation PSV under oscillation of "Dither
vibration" and "Spool" become equalized, and it causes the upper frame to resonate.
4. Action Required
If customer complaint about the sound and or vibration while arm-in operation, you are
required to test the unit to ensure the condition and install the orifice connector to solve
problem.
Applicable S/No. for field unit
SK200-6E / SK200LC-6E : YN09-34680~ 36979, YQ09-04864~ 05242
SK230-6E / SK230LC-6E : LQ10-04895~ 04985, LL10-03635~ 03858
5. Rework Instruction
Insert 0.8mm orifice connector P/No.YN06H01017P1 on the top of the arm recirculation
spool cap ”a6 port" as illustrated in above.