Grila - LCC
50
47
*ØU = 525
Ø = 560
*ØU = Ceiling grid opening = 525 mm, all sizes.
LCC Ød m
mm kg
125 1.25
Description 160 1.50
LCC is a flush mounted circular diffuser with a circular 200 2.30
unperforated face plate for installation in ceiling systems 250 3.40
and permanent ceilings. LCC can be used for both supply 315 4.60
and extract air. LCC is suitable for horizontal supply of
cooled air and has a large dynamic range. Ød = 125-250 => LCC has mounting holes for MB .
Installing an LCC diffuser in a plenum box type MB can help
to achieve a stable airflow to the diffuser as well as realise
the potential for individual adjustment.
Damper type B is an unique linear cone damper which
allows to use the full operational area (0-100%) and allows
to balance with a high pressure drop over the box with low
sound generation. Furthermore the construction of the
damper gives an accurate and reliable measurement.
Damper type C and E are with rotating blade dampers for
respectively supply and extract. Typically used in applica-
tions that don’t require a high balancing pressure in the ple-
num box.
The LCC can with the plenum box MBBV be used in a Pas-
cal system.
The LCC can be ordered with a presence sensor (-P), a tem- Ød = 315 => LCC has no mounting holes for MB !
perature sensor (-T) or both (-P-T). The sensors are built into
the faceplate.
Maintenance
The faceplate can be removed to enable cleaning of internal
parts or to gain access to the plenum box. the visible parts
Brackets included for LCC, for details, see the Integra instal-
of the diffuser can be wiped with a damp cloth.
lation instruction.
Order code
Product LCC aaa (-xx)
Type
LCC
Connection dim. Materials and finish
Ød 125-315
Sensor type
Upper part: Galvanised steel
No sensor Face plate: Aluminium
(-P) Presence sensor Face plate finish: Powder coated
(-T) Temperature sensor Standard colours: RAL 9003 and RAL 9010, gloss 30
(-P-T) Presence sensor / Temperature sensor
Other colours are available. Please contact Lindab's sales
Example: LCC-160-P-T department for futher information.
Plenum box MB
LCC + MB
D LxW
B
Ød1
H
Ød2
e C
LKP + MB LCP + MB
D LxW D LxW
B
B
Ød1
Ød1
H
H
Ød2 Ød2
e C e C
LKP + MB LCC/LCP + MB
Ød1 Ød2 B C D e H* L W Ød1 Ød2 B C D e H* L W
mm mm mm mm
100 125 62 245 78 40 198 - 238 310 260 100 125 62 245 78 40 206 - 246 310 260
100 160 62 245 78 40 198 - 238 310 260 100 160 62 245 78 40 206 - 246 310 260
125 125 75 291 78 40 223 - 263 376 310 125 125 75 291 78 40 231 - 271 376 310
125 160 75 291 78 40 223 - 263 376 310 125 160 75 291 78 40 231 - 271 376 310
125 200 75 291 78 40 223 - 263 376 310 125 200 75 291 78 40 231 - 271 376 310
160 160 92 352 78 40 257 - 297 459 380 160 160 92 352 78 40 265 - 305 459 380
160 200 92 352 78 40 257 - 297 459 380 160 200 92 352 78 40 265 - 305 459 380
160 250 92 352 78 40 257 - 297 459 380 160 250 92 352 78 40 265 - 305 459 380
200 200 112 425 78 40 298 - 338 565 460 200 200 112 425 78 40 306 - 346 565 460
200 250 112 425 78 40 298 - 338 565 460 200 250 112 425 78 40 306 - 346 565 460
200 315 112 425 78 40 298 - 338 565 460 200 315 112 425 78 40 306 - 346 565 460
250 250 137 514 118 60 348 - 388 698 540 250 250 137 514 118 60 356 - 396 698 540
250 315 137 514 118 60 348 - 388 698 540 250 315 137 514 118 60 356 - 396 698 540
315 315 170 675 118 60 413 - 453 858 540 315 315 170 675 118 60 421 - 461 858 540
* Using accessory MBZ the H dimension will increase: * Using accessory MBZ the H dimension will increase:
Ød2 = 125 - 200 mm => H +40 mm Ød2 = 125 - 200 mm => H +40 mm
Ød2 = 250 - 315 mm => H +60 mm Ød2 = 250 - 315 mm => H +60 mm
For full configuration of your LCC/LCP/LKP diffuser, go l0.2 [m] LCC/LKP/LCP 125
160 250
200 315
to the LindQST Airborne configurator. 10
8
7
Capacity 6
5
Air flow qv [l/s] and [m3/h], total pressure Δpt [Pa], throw l0.2
4
[m] and sound power level LWA [dB(A)] can be seen in the
3
diagrams.
2
Frequency-related sound power level
The sound power level in the frequency band is defined as
l 0.2 [m]
LWA+Kok. Kok values are specified in charts beneath the dia- 1
qV [l/s]
grams on the following pages. 15 20 30 40 50 60 70 100 150 200 300 500
qV [m3/h]
60 70 100 150 200 300 500 700 1000 1500
Balancing
Balancing guide, see the MB installation instruction.
LCC/LKP/LCP without box – supply air LCC/LKP/LCP 125 + MBB-S - Supply air
30 25
20
20
15
LWA dB(A)
,7! D" !
10
Q6 ;LS= qV [l/s]
15 20 25 30 40 50 60 70 80 100
Q6 ;MH= qV [m3/h]
60 70 80 100 150 200 300
40
100
35
70
50 30
25
30
20
20
15
LWA dB(A)
10
qV [l/s]
10 15 20 25 30 40 50 60 70 80 90
qV [m3/h]
40 50 60 70 80 100 150 200 300
LCC/LKP/LCP 160 + MBB-S - Supply air LCC/LKP/LCP 200 + MBB-S - Supply air
30 25 30 25
20 20 20 20
15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
20 25 30 40 50 60 70 80 100 120 30 40 50 60 70 80 100 120 140 160
qV [m3/h] qV [m3/h]
80 100 150 200 300 400 150 200 300 400 500
15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
10 15 20 25 30 40 50 60 70 80 100 20 25 30 40 50 60 70 80 100 120 140
qV [m3/h] qV [m3/h]
40 50 60 70 80 100 150 200 300 80 100 150 200 300 400 500
LCC/LKP/LCP 250 + MBB-S - Supply air LCC/LKP/LCP 315 + MBB-S - Supply air
30 30 30 30
25 25
20 20
15 20 15 20
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
50 60 70 80 100 120 140 160 180 200 240 280 50 60 70 80 90 100 150 200 250 300 350 400
3
qV [m /h] qV [m3/h]
200 300 400 500 700 1000 200 300 400 500 700 1250
100 45 100 45
70 40 70 40
50 35 50 35
30 30
30 30
25 25
20 20 20 20
15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
50 60 70 80 100 120 140 160 180 200 240 50 60 70 80 90 100 150 200 250 300 350 400
qV [m3/h] qV [m3/h]
200 300 400 500 700 200 300 400 500 700 1250
15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
30 40 50 60 70 80 100 120 140 160 180 50 60 70 80 100 120 140 160 180 200 240 280
qV [m3/h] qV [m3/h]
150 200 300 400 500 200 300 400 500 700 1000
100 40
70
35
50
30
30
25
20
15 20
LWA dB(A)
10
qV [l/s]
5 10 15 20 25 30 40 50 60 80
qV [m3/h]
20 30 40 50 60 70 80 100 150 200 300
LCC/LKP/LCP 160 + MBB-E - Extract air LCC/LKP/LCP 200 + MBB-E - Extract air
150 150 45
40
100 100 40
35
70 70 35
30
50 50 30
25
25
30 20 30
20
20 20
15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
10 15 20 25 30 40 50 60 80 100 150 200 20 25 30 40 50 60 80 100 150 200 250
qV [m3/h] qV [m3/h]
40 50 60 70 80 100 150 200 300 400 500 700 80 100 150 200 300 400 500 700
100 40 100 40
70 35 70 35
50 50 30
30
25
30 25 30
20
20 20
20
15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
10 15 20 25 30 40 50 60 80 100 120 140 10 15 20 25 30 40 50 60 80 100 150 200
qV [m3/h] qV [m3/h]
40 50 60 70 80 100 150 200 300 400 500 40 50 60 70 80 100 150 200 300 400 500 700
150 150
45 45
100 100
40 40
70 70
35 35
50 50
30 30
30 30
25 25
20 20
20 20
15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
5 10 15 20 25 30 40 50 60 80 10 15 20 25 30 40 50 60 80 100 120 140
3
qV [m /h] qV [m3/h]
20 30 40 50 60 70 80 100 150 200 300 40 50 60 70 80 100 150 200 300 400 500
LCC/LKP/LCP 250 + MBB-E - Extract air LCC/LKP/LCP 315 + MBB-E - Extract air
100 40 100 40
35 35
70 70
30
50 30 50
25
25
30 30 20
20
20 20
15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
20 25 30 40 50 60 80 100 150 200 250 20 25 30 40 50 60 80 100 150 200 250 300
qV [m3/h] qV [m3/h]
80 100 150 200 300 400 500 700 80 100 150 200 300 400 500 700 1000
50 30 50 30
25 25
30 30
20
20
20 20
15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
20 25 30 40 50 60 80 100 150 200 250 20 25 30 40 50 60 80 100 150 200 250 300
qV [m3/h] qV [m3/h]
80 100 150 200 300 400 500 700 80 100 150 200 300 400 500 700 1000
30 30
50 50
25
25
30 30
20
20
20 20
15 15
LWA dB(A) LWA dB(A)
10 10
qV [l/s] qV [l/s]
10 15 20 25 30 40 50 60 80 100 150 200 20 25 30 40 50 60 80 100 150 200 250
3
qV [m /h] qV [m3/h]
40 50 60 70 80 100 150 200 300 400 500 700 80 100 150 200 300 400 500 700