Certified, Field-Proven GSM-R Radio Networks: Product Overview

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Certified, field-proven

GSM-R Radio Networks

EIRENE-certified and field-proven, the Nokia Flexi EDGE Base Station allows
railway operators to build reliable, cost-effective and long-lasting GSM-R radio
networks for all their operational communications.

Product overview
Nokia Flexi EDGE Base Station allows railway
operators to build a reliable, cost-effective and
long-lasting GSM-R radio network for all their
operational communications. With thousands of
systems deployed worldwide, the field-proven Nokia
Flexi Base Station has been enhanced to fulfill the
needs of railway networks on particular frequency
bands for high reliability and high redundancy,
and to meet specific requirements such as
tunnel coverage.
Flexi EDGE Base Station is European Integrated
Railway Radio Enhanced Network (EIRENE) certified,
is interoperability tested and is already successfully
deployed in numerous GSM-R railway projects all
over the world.
Built from compact weather-proof modules, Nokia
All-purpose base station Flexi EDGE Base Station eliminates the need for
bulky cabinets, enabling deployment at almost any
Nokia Flexi EDGE Base Station is highly adaptable. site to provide coverage wherever needed. Modules
Small or large configurations are possible, from a 1 can be stacked on the floor or a shelf, fixed on walls
TRX configuration right up to 216 TRX, indoors or or poles and are small enough to be installed in
outdoors, exceeding typical railway operator needs existing base station cabinets for easy migration of
at large railway stations or shunting areas. networks to the latest technology.

1 Data sheet
Nokia Flexi EDGE BTS
Railway operators can use Nokia Flexi EDGE Base Station can be reduced to less than one hour
Station to meet all their application and coverage following preparation of the site and equipment.
needs. They can make use of standard GSM
features, railway-specific features and high value
features to build coverage along single rail tracks
Flexible deployment options
and within tunnels, or to provide full capacity for Nokia Flexi EDGE Base Station brings a new level
urban station hot spots. of flexibility for outdoor and indoor sites. With no
cabinet needed, Nokia Flexi EDGE Base Station
Lowest overall costs is one of the market’s smallest GSM macro base
stations at any capacity. Railway operators are no
With its many cost-saving features and high
longer forced into using a 24 TRX cabinet when only
availability, Nokia Flexi EDGE Base Station helps
a 2 TRX base station is needed, for example.
railway operators to achieve a low Total Cost of
Ownership (TCO) for their radio networks. The If a cabinet is required, the railway operator may
combination of lower CAPEX and OPEX per site, choose either indoor or outdoor versions which can
and fewer sites in total for new networks all add then also be used to house ancillary equipment like
up to much lower overall costs during planning, batteries.
implementation and operation of the network. Tunnel coverage is easily achieved by the Flexi EDGE
Base Station feederless solution, deploying optical
Suits new deployments cables between base station system components
and TRX modules to reduce or even eliminate the
and migration projects need for repeaters.
Available in GSM 900 and1800, Nokia Flexi EDGE Transmission capacity savings are achieved by
Base Station supports the railway-dedicated IP transmission using Packet Abis over IP with
frequency bands for standard GSM-R as well as for full support for Quality of Service (QoS) and two
enhanced GSM-R: synchronization options (Synchronous Ethernet or
Timing over Packet IEEE1588).
• GSM-R: 876 - 880 MHz / 921 - 925 MHz
• ER-GSM: 873 - 876 MHz / 918 - 921 MHz
Indoors or outdoors
In new deployments, a balanced link featuring high
Nokia Flexi EDGE Base Station simplifies site
transmit power and excellent receiver sensitivity
acquisition by enabling a vast choice of existing
helps to create a larger cell size for greater coverage.
and entirely new locations and by reducing the
There are several ways to boost the base station’s amount of civil works needed to prepare a site. The
reach even further. Nokia Flexi EDGE TRX can base station modules can be carried and installed
be used in double power mode, while the base by a single person. No special lifting equipment is
station supports Nokia Smart Radio Concept needed, outdoor shelters are no longer mandatory,
(SRC), including Intelligent Downlink Diversity there is no need for costly air conditioning for
(IDD) functionality. The uplink performance can be indoor or outdoor installations and base station
improved by using 4-way uplink diversity. commissioning requires no special skills.
For migration projects, the output power of a Flexi With its low footprint-to-capacity ratio, Nokia
EDGE Base Station can be fine-tuned in steps of Flexi EDGE Base Station also uses existing site
1 dB to adapt cell coverage to the former space more efficiently and may re-use existing
equipment setup, eliminating the need for time- transmission capability and power supply back up
consuming radio network replanning. Switchover investments.
from old equipment to a new Flexi EDGE Base

2 Data sheet
Nokia Flexi EDGE BTS
Reliable high performance Environmentally friendly
With redundancy being especially important in Nokia Flexi EDGE Base Station’s high performance
mission-critical railway networks, Flexi EDGE Base and compact size enables coverage and capacity
Station offers both TRX and/or system module to be built using less equipment across fewer
redundancy options. and smaller sites in new deployments. These
environmentally-friendly credentials are further
Loop Protection may also be configured and can be
enhanced by lower transportation needs,
implemented even in mixed Flexi EDGE BTS/BTS+
complementing the environmental benefits of Nokia
networks.
smart logistics solutions.
High speed trains are supported as specified in
Nokia Flexi EDGE Base Station uses less
EIRENE with speeds of 500 km/h and above.
manufacturing material and complies with European
The Flexi EDGE Base Station supports European Union environmental directives, such as RoHS.
Train Control System (ETCS) over GPRS/EDGE Packet Meanwhile, the base station’s exceptionally low
Data to meet future railway operator demands for electricity consumption, which is also helped by the
the possible highest data rates. elimination of power-hungry air conditioning, brings
further environmental benefits in daily operation.
Certified and interoperable
EIRENE certification encompasses TSI CCS 2012/88/ Services for full support
EU, amended by 2012/696 and 2015/14/EU in Nokia Flexi EDGE Base Station is available with a full
combination with the Harmonized Standards, portfolio of tailored Nokia services. Nokia has the
Voluntary Standards (or parts thereof) and people and processes and an extensive track record
Alternative Solutions as identified in the EC of successful network deployments in multi-vendor
Technical File (Section 5.1). EC Verification is limited environments and modernization projects. Services
to EIRENE SRS 15.4.0 and EIRENE FRS 7.4.0 to support Nokia Flexi EDGE Base Station cover all
Interoperability tests with other suppliers have been processes from planning, building and optimizing
successfully passed. mobile networks and services; to maintaining
and enhancing network performance; to training
Updating of EIRENE and interoperability testing for employees and improving operations.
future versions is ensured by Nokia’s dedicated end-
to-end GSM-R test and verification laboratory.

3 Data sheet
Nokia Flexi EDGE BTS
Product specifications
Installation options Without cabinet, indoors and outdoors: with modules stacked on the floor or a shelf,
mounted on a wall, pole or mast
With cabinet, indoors and outdoors: inside a Nokia Flexi cabinet or any 19” rack
Frequency bands GSM/EDGE 900 - 1800 MHz including
GSM-R 876 - 880 MHz / 921 - 925 MHz
ER-GSM 873 - 876 MHz / 918 - 921 MHz
Output power 47/49.5/53 dBm
Maximum capacity 216 TRX
Maximum number of sectors 6
Base station dimensions 1/0/0 with TRX redundancy with 3 module stack installation:
Height - 400 mm (9 U)*
Width - 447 mm
Depth - 560 mm
Module dimensions Height - 133 mm (3U); 89 mm (2U)
Width- 447 mm
Depth - 560 mm outdoor (422 mm without covers)
Maximum weight 11 kg heaviest single unit in stack configurations
45 kg for 1/0/0 TRX redundancy configuration base station (without cabinet)
Power consumption 0.8 kW with 1/0/0 and TRX redundancy configuration
Nominal DC voltage 40.5 – 57 V DC
Nominal AC voltage 184 – 276 V AC
Operating temperature –35 to +55 °C
Ingress protection class IP55
Transport E1 (asymmetric): 8 x 2M PCMs
E1/T1 (symmetric): 8 x 2M PCMs
IP: GE and FE

Nokia is a registered trademark of Nokia Corporation. Other product and company names
mentioned herein may be trademarks or trade names of their respective owners.

Nokia Oyj
Karaportti 3
FI-02610 Espoo
Finland
Tel. +358 (0) 10 44 88 000

Product code: SR1610001104EN

© Nokia 2016 nokia.com

You might also like