Minichiller Catalog
Minichiller Catalog
Air Cooled
PRODUCT SYSTEM
Application
Air Cooled ini
Chiller
an Coil nit
Printed n alaysia
Contents Products Overview
kW
Cooling & Heating Capacity
4.0 6.0 8.0 10.0 15.0 20.0 25.0 30.0 40.0 50.0
R22 020/025/030/040/050/060/080/100/120/150
UAE 020/025/030/040/050/060/080/100/120/150
Application
025/030/040/050/060/080/100/120/150
01 R407C
UAP 060/080/100/120/150
020/025/030/040/050/055
04
FWE-E
Fan Coil Units
FWC-C
14 15 16 17 19
Wall Mounted Ceiling Casse e Ceiling Casse e Ceiling Casse e Ceiling Convertible
Compact Type (600 x 600) Type (900 x 900) Type (900 x 900) Type
With Brushless DC Motor
20 21 23
Ceiling Convertible Ceiling Concealed Type Ducted Blower Type
Type
Remark: All unit photos in this catalog are solely for illustration purpose, actual outlook may differ slightly.
All specifications are subjected to change by the manufacturer without prior notice.
Application
Availablility of
cooling only
& heatpump
models
Hotels ce ooms @ Coffee Houses
estaurant
ong Piping
Application
Chilled Water
ystem olution
Ad antages
1 2
Air Cooled
QUIET OPERATION VERSATILITY IN SYSTEM COUPLING
Quiet operation due to fan coil units Chilled water system is designed with versatility in system
and chiller can be placed far away coupling where there is no limitation in the number of
Mini Chiller
from room fan coil unit coupling with mini chiller as long as they meet
the designed capacity requirament & water flow rate.
System coupling of one to one and one to many
configurations
The Daikin mini chiller is fully assembled, complete FACTORY PRECHARGED REFRIGERANT
with all necessary components in one unit like water
Each heat exchanger in the chiller is brazed
pump, internal wiring, fully charged with refrigerant SERVICEABILITY & ERROR CODE FOR EASE OF
and undergo strict testing and quality check before and tested against leakages through dried air
TROUBLESHOOTING
delivery. Only connection to water piping and power at 30 bars. After that, another process of
supply is required at site. system vacuuming is done before it is By opening the front panel, one can access and service all the
components in the chiller. The chiller is equipped with self
accurately charged with refrigerant to ensure
diagnosis function which allow the chiller panel to display total of
optimum performance. Thus, it saves the 19 type of faulty occurred in the system by showing different
hustles of field charging by installers. error code on the LCD screen of the panel.
Refrigarent
3 4
PARALLEL INSTALLATION MICROPROCESSOR CONTROL SAFETY PROTECTION
Daikin Mini Chiller provides flexibility in adding Daikin chillers are equipped with microprocessor The safety protections provided for the Daikin chiller
capacity for building extension. This can be done controller that will control and regulate the operation are
by installing the mini chiller in parallel of the unit. High & Low Pressure Switches
connection. Anti Freeze Protection Sensor
Besides that, the controller that contains the well Discharge Temperature Sensor
A network of up to 50 chillers is possible to be
developed algorithm will provide protection to the Over Pressure Relief alve
connected in a system. For ease of controlling
chiller by accurately sensing the key temperatures in Water Pressure Differential Switch
and se ng, Daikin Mini Chiller panel can be used both the water and refrigerant circuit. Should there be Anti Freeze Heater on BPHE
as either Master or Slave. This function allows any abnormal reading received by controller, an alarm Compressor Water Pump & Fan Motor Overload
user to monitor all the se ngs on the slave units signal will be sent to chiller panel, followed by Protector
at the master unit. protection action plans such as to stop the operation
of compressor, condenser fan motor or circulating
water pump.
Supported Up To 50 Units Of Chiller
Chiller 0 Chiller 1 Chiller 2
BRAZED PLATE HEAT EXCHANGER (BPHE)
The heat exchanger is
made of AISI 31
stainless steel plates
closely arranged and
brazed together to
5 way wire (CM8)
Chiller
maximize possible
Chiller Panel 0 Chiller Panel 1 Communication us heat exchange
efficiency.
A stainless steel PH
P A
C C A P A C
State-Of-The-Art Components
CHILLER CONTROL PANEL The display is shown in an 8 lines graphical LCD
SCROLL COMPRESSOR ANTI-FREEZE PROTECTION display. There are 8 dedicated keys available in the
The chiller panel controller is designed to control the
panel.
Scroll Compressors are used for the units to offer a The chiller unit has several anti freeze protection chiller operation. This device allows the user to have
Menu selection.
quieter and more reliable performance over a wide features customized control for each connected unit.
Navigation on the screen.
operating temperature range. (Except UAE0 0C/CR
1. Built in heater in BPHE Modification of the selected value.
which uses rotary compressor). Each chiller will have a chiller control panel that
The BPHE has a strip heater around it to prevent water
comes as a standard accessory. At the same time, the
freezing inside.
For UA(E/P) 030, 0 0, 050, 0 0, 080, 100, 1 0, 150 chiller control panel is able to be installed remotely
CR, phase protector is provided to prevent the . Anti Freeze sensor through the cable up to a distance of 100 meters.
compressor from rotating in the wrong directions. BPHE can avoid the frosting as the anti freeze sensor Example, the chiller panel can be installed in a
will send the signal to cut out the compressor if the centralized plant control room for the building.
water temperature becomes too cold.
Copeland 3. Water pressure differential switch The chiller control panel has been designed taking into
Compliant
This protection feature will ensure there is water flow consideration of the user friendly and yet versatile
Scrolls
in pipings when the chiller is in operation. Otherwise, control features.
High Efficiency
the compressor will cut out immediately.
Motor
Features
Whole system configuration.
Quiet Shutdown Unique parameter se ngs.
Device
Operation status display.
Tracing fault record (offer quick troubleshooting
solutions).
5 6
LOAD BALANCING CONTROL ANTI CORROSION GOLD ALUMINUM FIN
FLEXIBILITY :
For UA(E/P)080 ~ 150 C/CR both compressors will old Aluminum fin is offered as the standard material
cut in and cut out depending on their of the condenser heat exchanger of this series of
TRUE DUAL CIRCUITS BPHE
accumulative operating time. This sequencing chiller.
control feature will ensure no single compressor is Apply sophisticated technology of true dual circuit
overload in operation as well as to ensure longer BPHE.
reliability of compressors.
The true dual BPHE puts the secondary circuit
CAPACITY STEP CONTROL (water) in contact with 2 primary circuits
UA(E/P)080 ~ 150 C/CR has been designed with two (refrigerant). So even if one primary circuit is shut
separate refrigerant circuits, i.e. it has two off, each secondary channel is still in contact with a
compressors. By doing so, the unit has part loading primary channel. These advantages have made the
capabilities, i.e. 0 50 100 of rated capacity. This will product the natural choice for flexible chillers,
improve the reliability and energy efficiency of the climate control applications and high precision
unit, especially during low loading operations. systems food cooling cabinets in supermarkets.
7 8
R22 AIR COOLED MINI CHILLER SPECIFICATION
R22 COOLING MODEL R22 HEATPUMP MODEL
MODEL UAE020C UAE025C UAE030C UAE040C UAE050C UAE060C MODEL UAE020CR UAE025CR UAE030CR UAE040CR UAE050CR UAE060CR
Btu/h 20,000 24,200 30,000 39,500 48,500 54,000 Btu/h 19,000 23,000 27,500 38,000 44,000 50,000
NOMINAL COOLING CAPACITY NOMINAL COOLING CAPACITY W 5,570 6,740 8,060 11,140 12,900 14,650
W 5,860 7,090 8,790 11,580 14,210 15,830
NORMAL TOTAL INPUT POWER COOLING W 2,650 2,680 3,540 4,490 5,080 5,770 Btu/h 22,000 27,000 35,000 43,000 50,000 55,000
NOMINAL HEATPUMP CAPACITY
NORMAL RUNNING CURRENT COOLING A 12.25 12.17 16.41 9.67 9.75 12.01 W 6,450 7,910 10,260 12,600 14,650 16,120
EER W/W 2.21 2.65 2.48 2.58 2.80 2.74 COOLING W 2,530 2,670 3,440 4,230 5,190 5,580
NORMAL TOTAL INPUT POWER
HEATPUMP W 2,600 2,790 3,430 4,390 5,100 5,320
REFRIGERANT CONTROL (EXPENSION DEVICE) CAPILLARY TUBE
REFRIGERANT CHARGE kg 1.25 1.80 1.88 2.80 3.15 3.30 COOLING A 11.78 12.17 17.27 9.05 9.77 12.60
NORMAL RUNNING CURRENT
POWER SOURCE (OUTDOOR) V/Ph/Hz 220-240/1/50 380-415/3/50 HEATPUMP A 11.62 12.70 17.25 9.14 9.72 11.50
REFRIGERANT TYPE R22 EER W/W 2.20 2.52 2.34 2.63 2.48 2.63
SOUND PRESSURE LEVEL dBA 57 57 58 59 59 59 COP W/W 2.48 2.84 2.99 2.87 2.87 3.03
UNIT DIMENSION HEIGHT X WIDTH X DEPTH mm 790 x 1,160 x 460 1,140 x 1,160 x 460 REFRIGERANT CONTROL (EXPENSION DEVICE) CAPILLARY TUBE
PACKING HEIGHT X WIDTH X DEPTH mm 920 x 1,270 x 570 1,551 x 1,270 x 570 REFRIGERANT CHARGE kg 1.43 1.75 1.83 3.50 4.10 4.00
UNIT WEIGHT kg 116 123 126 188 189 196 POWER SOURCE (OUTDOOR) V/Ph/Hz 220-240/1/50 380-415/3/50
NOMINAL WATER FLOW RATE COOLING I/s/m3/hr 0.29 / 1.03 0.33 / 1.20 0.42 / 1.51 0.53 / 1.90 0.67 / 2.40 0.76 / 2.73 REFRIGERANT TYPE R22
INDOOR UNIT
INDOOR UNIT
NOMINAL WATER FLOW RATE
CAPACITY / VOLUME L 22 40 HEATPUMP I/s/m3/hr 0.31 / 1.12 0.38 / 1.38 0.49 / 1.75 0.56 / 2.00 0.62 / 2.20 0.76 / 2.72
TANK
MATERIAL MILD STEEL WITH ZINC TYPE ROTARY SCROLL
COMPRESSOR
STAGE OF CAPACITY CONTROL 0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100%
TYPE THREAED
MODEL UAE080C UAE100C UAE120C UAE150C
CONNECTION mm 25.4
Btu/h 85,000 95,000 116,000 138,000 PIPING 110
NOMINAL COOLING CAPACITY COOLING kPa 79 94 92 118 104
W 24,910 27,840 34,000 40,450 HEAD
HEATPUMP kPa 79 86 73 103 85 87
NORMAL TOTAL INPUT POWER COOLING W 8,870 10,590 11,370 14,220
TANK CAPACITY / VOLUME L 22 40
NORMAL RUNNING CURRENT COOLING A 17.00 18.50 25.80 31.80 MATERIAL MILD STEEL WITH ZINC
EER W/W 2.81 2.63 2.99 2.84
REFRIGERANT CONTROL (EXPENSION DEVICE) TXV
REFRIGERANT CHARGE kg 3.90 x 2 4.60 x 2 6.00 x 2 7.10 x 2
POWER SOURCE (OUTDOOR) V/Ph/Hz 380-415/3/50 MODEL UAE080CR UAE100CR UAE120CR UAE150CR
REFRIGERANT TYPE R22 Btu/h 80,000 95,000 113,000 138,000
SOUND PRESSURE LEVEL dBA 63 63 67 67 NOMINAL COOLING CAPACITY W 23,450 27,840 33,120 40,450
UNIT DIMENSION HEIGHT X WIDTH X DEPTH mm 1,245 x 1,500 x 900 1,245 x 1,800 x 1,150 Btu/h 95,000 105,000 120,000 132,000
NOMINAL HEATPUMP CAPACITY
PACKING HEIGHT X WIDTH X DEPTH mm 1,452 x 1,732 x 1,032 1,452 x 2,032 x 1,282 W 27,840 30,770 35,170 38,690
INDOOR UNIT
UNIT WEIGHT kg 340 340 480 560 COOLING W 8,490 11,100 12,070 14,320
NORMAL TOTAL INPUT POWER
NOMINAL WATER FLOW RATE COOLING I/s/m3/hr 1.22 / 4.40 1.36 / 4.90 1.67 / 6.00 2.00 / 7.20 HEATPUMP W 8,750 10,310 12,370 15,020
TYPE SCROLL COOLING A 18.40 18.90 26.60 31.40
COMPRESSOR NORMAL RUNNING CURRENT
STAGE OF CAPACITY CONTROL 0 - 50 - 100% 0 - 50 - 100% 0 - 50 - 100% 0 - 50 - 100% HEATPUMP A 18.90 17.10 26.80 32.20
TYPE THREAED EER W/W 2.76 2.51 2.74 2.82
PIPING CONNECTION mm 31.75 COP W/W 3.18 2.98 2.86 2.58
HEAD COOLING kPa 229 229 188 157 REFRIGERANT CONTROL (EXPENSION DEVICE) CAPILLARY TUBE
REFRIGERANT CHARGE kg 5.00 x 2 5.40 + 5.30 7.60 x 2 6.50 x 2
ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE POWER SOURCE (OUTDOOR) V/Ph/Hz 380-415/3/50
ALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT) REFRIGERANT TYPE R22
SOUND PRESSURE LEVEL dBA 63 63 67 67
TEMPERATURE COOLING HEATING UNIT DIMENSION HEIGHT X WIDTH X DEPTH mm 1,245 x 1,500 x 900 1,245 x 1,800 x 1,150
ENTERING 12°C 40°C PACKING HEIGHT X WIDTH X DEPTH mm 1,452 x 1,732 x 1,032 1,452 x 2,032 x 1,282
EVAPORATOR UNIT WEIGHT kg 340 340 480 560
INDOOR UNIT
LEAVING 7°C 45°C I/s/m3/hr
COOLING 1.13 / 4.05 1.33 / 4.80 1.67 / 6.00 2.00 / 7.20
NOMINAL WATER FLOW RATE
CONDENSOR AMBIENT 35°C 7°C / 6°C HEATPUMP I/s/m3/hr 1.13 / 4.05 1.33 / 4.80 1.67 / 6.00 2.00 / 7.20
SCROLL
COMPRESSOR
STAGE OF CAPACITY CONTROL 0 - 50 - 100% 0 - 50 - 100% 0 - 50 - 100% 0 - 50 - 100%
TYPE THREAED
CONNECTION mm 31.75
PIPING COOLING kPa 254 173 188 157
HEAD
HEATPUMP kPa 229 144 188 157
ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE
ALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)
9 10
R407C AIR COOLED MINI CHILLER SPECIFICATION R407C HEATPUMP MODEL
R407C COOLING MODEL MODEL UAP060CR UAP080CR UAP100CR UAP120CR UAP150CR
Btu/h 50,000 74,000 87,500 110,000 130,000
MODEL UAP025C UAP030C UAP040C UAP050C UAP060C NOMINAL COOLING CAPACITY W 14,650 21,690 25,640 32,240 38,100
Btu/h 23,000 26,900 38,500 47,000 50,000 Btu/h 55,000 90,000 96,000 118,000 144,000
NOMINAL COOLING CAPACITY NOMINAL HEATPUMP CAPACITY
W 6,740 7,880 11,280 13,920 14,650 W 16,120 26,380 28,140 34,580 42,200
NORMAL TOTAL INPUT POWER COOLING W 2,950 3,770 4,680 5,430 6,040 COOLING W 6,280 8,990 11,100 12,630 15,900
NORMAL TOTAL INPUT POWER
NORMAL RUNNING CURRENT COOLING A 13.30 17.41 9.62 10.20 11.28 HEATPUMP W 5,570 9,350 11,110 12,750 16,100
EER W/W 2.29 2.09 2.41 2.56 2.43 NORMAL RUNNING CURRENT COOLING A 11.60 18.90 19.00 27.10 34.40
HEATPUMP A 11.50 19.00 19.10 26.70 34.80
REFRIGERANT CONTROL (EXPENSION DEVICE) CAPILLARY TUBE 2.55
EER W/W 2.33 2.41 2.31 2.40
REFRIGERANT CHARGE kg 1.72 1.63 3.00 3.30 3.20 COP W/W 2.82
2.89 2.53 2.71 2.62
POWER SOURCE (OUTDOOR) V/Ph/Hz 220-240/1/50 380-415/3/50 REFRIGERANT CONTROL (EXPENSION DEVICE) CAPILLARY TUBE
REFRIGERANT TYPE R407C REFRIGERANT CHARGE kg 4.00 3.70 X 2 4.80 + 4.70 5.80 x 2 6.40 x 2
SOUND PRESSURE LEVEL dBA 57 58 59 59 60 POWER SOURCE (OUTDOOR) V/Ph/Hz 380-415/3/50
UNIT DIMENSION HEIGHT X WIDTH X DEPTH mm 790 x 1,160 x 460 1,140 x 1,160 x 460 REFRIGERANT TYPE R407C
mm 920 x 1,270 x 570 1,551 x 1,270 x 570 SOUND PRESSURE LEVEL dBA 60 63 63 67 67
PACKING HEIGHT X WIDTH X DEPTH
UNIT DIMENSION HEIGHT X WIDTH X DEPTH mm 1,140 x 1,160 x 460 1,245 x 1,500 x 900 1,245 x 1,800 x 1,150
UNIT WEIGHT kg 123 126 188 189 196
INDOOR UNIT
PACKING HEIGHT X WIDTH X DEPTH mm 1,551 x 1,270 x 570 1,452 x 1,732 x 1,032 1,452 x 2,032 x 1,282
NOMINAL WATER FLOW RATE COOLING I/s/m3/hr 0.31 / 1.11 0.38 / 1.36 0.53 / 1.90 0.64 / 2.30 0.69 / 2.50 UNIT WEIGHT kg 203 340 340 480 560
INDOOR UNIT
TYPE SCROLL COOLING I/s/m3/hr 0.64 / 2.30 1.03 / 3.70 1.25 / 4.50 1.67 / 6.00 1.89 / 6.80
COMPRESSOR NOMINAL WATER FLOW RATE 1.25 / 4.50
STAGE OF CAPACITY CONTROL 0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100% HEATPUMP I/s/m3/hr 0.78 / 2.80 1.03 / 3.70 1.67 / 6.00 1.89 / 6.80
TYPE THREAED COMPRESSOR TYPE SCROLL
STAGE OF CAPACITY CONTROL 0 - 100% 0 - 50 -100% 0 - 50 -100% 0 - 50 -100% 0 - 50 -100%
PIPING CONNECTION mm 25.4
TYPE THREAED
HEAD COOLING kPa 94 93 117 93 110 CONNECTION mm 25.4 31.75
CAPACITY / VOLUME L 22 40 PIPING
COOLING kPa 110 263 193 188 172
TANK HEAD HEATPUMP 238 170 172
MATERIAL MILD STEEL WITH ZINC kPa 87 188
ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE
MODEL UAP080C UAP100C UAP120C UAP150C ALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)
Btu/h 80,000 90,000 115,000 137,000
NOMINAL COOLING CAPACITY TEMPERATURE COOLING HEATING
W 23,450 26,380 33,730 40,150
NORMAL TOTAL INPUT POWER COOLING W 9,430 11,210 12,170 14,970 ENTERING 12°C 40°C
NORMAL RUNNING CURRENT COOLING A 18.00 19.22 26.50 33.00 EVAPORATOR
EER W/W 2.49 2.35 2.77 2.68 LEAVING 7°C 45°C
CONDENSOR AMBIENT 35°C 7°C / 6°C
REFRIGERANT CONTROL (EXPENSION DEVICE) TXV
REFRIGERANT CHARGE kg 3.90 x 2 3.80 x 2 5.60 x 2 6.00 x 2
POWER SOURCE (OUTDOOR)
REFRIGERANT TYPE
V/Ph/Hz 380-415/3/50
R407C
R410A AIR COOLED MINI CHILLER SPECIFICATION
SOUND PRESSURE LEVEL dBA 63 63 67 67
UNIT DIMENSION HEIGHT X WIDTH X DEPTH mm 1,245 x 1,500 x 900 1,245 x 1,800 x 1,150 R410A HEATPUMP MODEL
PACKING HEIGHT X WIDTH X DEPTH mm 1,452 x 1,732 x 1,032 1,452 x 2,032 x 1,282
UNIT WEIGHT kg 340 340 480 560 MODEL UAQ020CR UAQ025CR UAQ030CR UAQ040CR UAQ050CR UAQ055CR
INDOOR UNIT
NOMINAL WATER FLOW RATE COOLING I/s/m3/hr 1.14 / 4.10 1.25 / 4.50 1.67 / 6.00 2.00 / 7.20 Btu/h 15,700 21,000 24,800 34,000 41,600 45,000
NOMINAL COOLING CAPACITY
TYPE SCROLL W 4,600 6,150 7,270 10,000 12,200 13,200
COMPRESSOR Btu/h 21,500 25,000 32,500 43,000 48,000 55,000
STAGE OF CAPACITY CONTROL 0 - 50 - 100% 0 - 50 - 100% 0 - 50 - 100% 0 - 50 - 100% NOMINAL HEATPUMP CAPACITY
TYPE THREAED W 6,300 7,330 9,530 12,600 14,070 16,120
COOLING W 2,620 2,760 3,830 5,000 5,310 5,490
PIPING CONNECTION mm 31.75 NORMAL TOTAL INPUT POWER
HEATPUMP W 2,590 2,790 3,630 4,650 5,150 5,440
HEAD COOLING kPa 229 229 188 157 COOLING A 11.76 12.70 16.68 7.44 7.90 8.18
NORMAL RUNNING CURRENT
HEATPUMP A 11.93 12.90 16.32 7.20 7.83 8.38
ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE EER W/W 1.76 2.23 1.90 2.00 2.30 2.40
ALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT) COP W/W 2.43 2.63 2.62 2.71 2.73 2.96
REFRIGERANT CONTROL (EXPENSION DEVICE) CAPILLARY TUBE CAPILLARY TUBE & TXV
TEMPERATURE COOLING HEATING REFRIGERANT CHARGE kg 1.20 1.725 2.20 4.30 4.20 4.30
POWER SOURCE (OUTDOOR) V/Ph/Hz 220-240/1/50 380-415/3/50
ENTERING 12°C 40°C REFRIGERANT TYPE R410A
EVAPORATOR
LEAVING 7°C 45°C SOUND PRESSURE LEVEL dBA 58 59 57 59 59 61
UNIT DIMENSION HEIGHT X WIDTH X DEPTH mm 790 x 1,200 x 460 790 x 1,050 x 460 1,140 x 1,060 x 460
CONDENSOR AMBIENT 35°C 7°C / 6°C PACKING HEIGHT X WIDTH X DEPTH mm 950 x 1,310 x 574 950 x 1,204 x 574 1,566 x 1,204 x 574
UNIT WEIGHT 3
kg 128 128 128 195 195 195
INDOOR UNIT
NOMINAL WATER FLOW RATE COOLING I/s/m3/hr 0.24 / 0.86 0.28 / 1.00 0.42 / 1.50 0.50 / 1.80 0.60 / 2.15 0.75 / 2.70
HEATPUMP I/s/m3/hr 0.32 / 1.16 0.35 / 1.25 0.42 / 1.50 0.50 / 1.80 0.60 / 2.15 0.75 / 2.70
TYPE ROTARY TANDEM ROTARY
COMPRESSOR STAGE OF CAPACITY CONTROL 0-100% 0-100% 0-50-100% 0-40-60-100% 0-40-60-100% 0-50-100%
TYPE THREADED
CONNECTION mm 25.4
PIPING
COOLING kPa 90 98 93 90 74 70
HEAD
HEATPUMP kPa 73 90 80 71 64 53
CAPACITY / VOLUME L 22 N/A
TANK
MATERIAL MILD STEEL WITH ZINC N/A
ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE
ALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)
11 12
Wall Mounted Type
AL
chilled water fan coil units that will meet most of indoor application requirements
covering residential, light commercial and commercial. › Stylish Front Panel › NIM Able
› Comfortable Air Flow & Lower Sound Level › Sleep Funtion For Cool & Heat Mode
› Indoor Quiet Mode › Auto Restart With Last State Memory
The aesthetically a ractive decorative fan coil units such as Wall Mounted models, › Turbo Mode › lave & laveless Control Options
Ceiling Casse e and Ceiling Convertible are compact and ergonomic, the ranges › Uniform Air Distribution › Self Diagnosis Features
› Easy Maintenance › Compact & Easy To Use Wireless Remote Controller
can blend in easily to any interior designs whether it is residential houses, office, › Wide Capacity Range › Microprocessor Control
restaurant or shops. › 5 Selectable Fan Speed › Automatic Air Swing
In addition, the Daikin chilled water fan coil units are designed with easy
pecification for all ounted ype
installation and easy servicing in mind. The fan coil units also include the
microprocessor controller that has built in algorithm to control the operation of the MODEL FWW02L FWW03L FWW04L FWW05L FWW06L
fan coil unit as well as to provide protection to the unit. NOMINAL COOLIN CAPACIT
Btu/h 8300 9200 11300 15500 18000
W 2430 2700 3310 4540 5280
Btu/h 6300 6900 9000 11700 14000
NOMINAL SENSIBLE COOLIN CAPACIT
W 1850 2020 2640 3430 4100
NOMINAL HEATIN CAPACIT Btu/h 11000 12000 15000 20500 25000
(ENTERIN WATER TEMP. 50 C) W 3220 3520 4400 6010 7330
NOMINAL TOTAL INPUT POWER W 31 32 42 57 72
NOMINAL RUNNIN CURRENT A 0. 0 0. 0 0. 1 0.30 0.3
POWER SOURCE /Ph/Hz 0 0 / 1 / 50
REFRI ERANT T PE N/A
AIR DISCHAR E AUTOMATIC LOU ER (UP & DOWN)
CONTROL
OPERATION LCD WIRELESS MICRO COMPUTER REMOTE CONTROL
HI H CFM 260 280 370 510 620
MEDIUM CFM 230 250 320 450 520
AIR FLOW
LOW CFM 200 220 260 390 460
QUIET CFM 180 190 240 360 440
US PM 1.85 .03 .51 3. 3 .01
NOMINAL WATER FLOW RATE
litres/min .00 . 8 9.50 13.00 15.18
INDOOR UNIT
HEAD LOSS (COOLIN ) kPa 3 .0 .0 31.0 30.0 3 .0
HEAD LOSS (HEATIN ) 50 C kPa 9.0 0.0 5.0 .0 33.0
MA . WOR IN PRESSURE kPa 1608
SURFACE AIR ELOCIT m/s 0. 8 0. 0.9 0.83 1.01
SOUND PRESSURE LE EL (H/M/L/Q) dBA 3 / 9/ 5/ 35 / 30 / 5 / / 39 / 3 / 9 / 38 / 3 / 3 / / 39 / 3
UNIT DIMENSION H W D mm 88 800 0 310 10 5
PAC IN DIMENSION H W D mm 3 x8 x 38 113 31
UNIT WEI HT kg 9 14
CONDENSATE DRAIN SI E mm 19.05
PIPE CONNECTION mm 1 . 0 BSP FEMALE THREAD ADAPTOR
13 14
Ceiling Casse e Compact ype Ceiling Casse e ype
* *
AL AL
Btu/h 6500 10000 11500 NOMINAL HEATING CAPACITY Btu/h 28000 33600 38300 45500 52000
NOMINAL SENSIBLE COOLING CAPACITY (ENTERING WATER TEMP. = 50°C)
W 1910 2930 3370 W 8210 9850 11230 13340 15240
Btu/h 12000 16000 18000 NOMINAL TOTAL INPUT POWER W 95 126 167 186 227
NOMINAL HEATING CAPACITY
(ENTERING WATER TEMP. = 50°C) W 3520 4690 5280 NOMINAL RUNNING CURRENT A 0.44 0.55 0.74 0.85 1.03
V/Ph/Hz 220-240 / 1 / 50 AIR DISCHARGE 4 WAY AUTOMATIC LOUVER (UP & DOWN)
POWER SOURCE CONTROL
N/A OPERATION LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL
REFRIGERANT TYPE
AIR DISCHARGE 4 WAY AUTOMATIC LOUVER (UP & DOWN) HIGH CFM 750 860 890 1000 1140
CONTROL MEDIUM CFM 620 700 720 840 1000
OPERATION LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL AIR FLOW
LOW CFM 480 540 570 680 840
HIGH CFM 380 400 440
QUIET CFM 320 380 420 540 700
AIR FLOW MEDIUM CFM 290 310 330
USGPM 4.71 5.59 6.69 8.45 9.60
LOW CFM 230 220 280 NOMINAL WATER FLOW RATE
litres/min 17.83 21.17 25.29 31.94 36.29
USGPM 2.03 3.43 3.57
NOMINAL WATER FLOW RATE HEAD LOSS (COOLING) kPa 20 37 22 44 53
INDOOR UNIT
litres/min 7.68 12.98 13.51
HEAD LOSS (HEATING) : 50°C kPa 19 33 19 38 47
HEAD LOSS (COOLING) kPa 19.3 26.9 28.8
INDOOR UNIT
17 18
Ceiling Con ertible ype Ceiling Con ertible ype
* *
AL AL
Wireless Remote Controller Wired Remote Controller Wireless Remote Controller Wired Remote Controller
FWE-D
FWE-E BRC52A BRC51A BRC52A BRC51A
› Compact Design › Saranet Filter › Two Way Air Discharge › Auto Restart With Last-State-Memory
› Far Air Throw › Sleep Function For Cool And Heat Mode › Auto Air Swing › alve Or alveless Control Options
› Auto Air Swing › Auto Restart With Last-State-Memory › Ceiling & Floor Installing Option › Self Diagnosis Features
› Service & Maintenance At Ease › alve Or alveless Control Options › Room Temperature Sensing › NIM-Able
› Ceiling & Floor Installing Option › Self Diagnosis Features › Saranet Filter › Choices Of Wired Or Wireless Remote Controller
› ersatile Installation › NIM-Able › Sleep Function For Cool And Heat Mode
› Room Temperature Sensing › Choices Of Wired Or Wireless Remote Controller
› 3 Selectable Fan Speed › Microprocessor Control
pecification for Ceiling Con ertible ype pecification for Ceiling Con ertible ype
MODEL FWE05E FWE06E FWE07E MODEL FWE07D FWE09D FWE13D
Btu/h 15500 20300 21000 Btu/h 24600 31200 45000
NOMINAL COOLING CAPACITY NOMINAL COOLING CAPACITY
W 4540 5950 6150 W 7210 9140 13190
Btu/h 12700 15400 16150 Btu/h 17700 25600 31400
NOMINAL SENSIBLE COOLING CAPACITY NOMINAL SENSIBLE COOLING CAPACITY
W 3720 4510 4730 W 5190 7500 9200
NOMINAL HEATIN CAPACIT Btu/h 19500 25000 28000 NOMINAL HEATIN CAPACIT Btu/h 28000 42300 51500
(ENTERING WATER TEMP. = 50 C) W 5720 7330 8210 (ENTERING WATER TEMP. = 50 C) W 8210 12400 15090
NOMINAL TOTAL INPUT POWER W 86 135 160 NOMINAL TOTAL INPUT POWER W 132 240 240
NOMINAL RUNNING CURRENT A 0.38 0.67 0.79 NOMINAL RUNNING CURRENT A 0.57 0.98 1.03
POWER SOURCE /Ph/Hz 220-240 / 1 / 50 POWER SOURCE /Ph/Hz 220-240/ 1 /50
REFRIGERANT TYPE N/A REFRIGERANT TYPE N/A
AIR DISCHAR E AUTOMATIC LOUVER (UP & DOWN) AIR DISCHAR E AUTOMATIC LOUVER (UP & DOWN)
CONTROL CONTROL
LCD WIRELESS MICRO-COMPUTER LCD WIRELESS MICRO-COMPUTER
OPERATION OPERATION
REMOTE CONTROL REMOTE CONTROL
HI H CFM 520 580 640 HI H CFM 697 956 1059
AIR FLOW MEDIUM CFM 460 530 560 AIR FLOW MEDIUM CFM 687 908 1023
LOW CFM 406 490 460 LOW CFM 650 889 956
USGPM 3.43 4.49 4.67 USGPM 5.46 6.91 9.99
NOMINAL WATER FLOW RATE NOMINAL WATER FLOW RATE
Litres/min 13 17 17.68 Litres/min 20.67 26.16 37.82
HEAD LOSS (COOLIN ) kPa 27 48 57 HEAD LOSS (COOLIN ) kPa 49 24 38
HEAD LOSS (HEATIN ) 50 C kPa 24 42 50 HEAD LOSS (HEATIN ) 50 C kPa 43 22 32
MA . WOR IN PRESSURE kPa 1608 MA . WOR IN PRESSURE kPa 1608
SURFACE AIR VELOCITY m/s 0.87 1.01 1.08 SURFACE AIR VELOCITY m/s 1.37 1.22 1.35
SOUND PRESSURE LE EL (H/M/L) dBA 45 / 38 / 36 46 / 43 / 39 49 / 46 / 41 SOUND PRESSURE LE EL (H/M/L) dBA 51 / 50 / 48 54 / 53 / 52 54 / 53 / 52
UNIT DIMENSION H W D mm 1 1090 30 UNIT DIMENSION H W D mm 249 x 1214 x 670 249 x 1714 x 670
PAC IN DIMENSION H W D mm 9 119 0 PAC IN DIMENSION H W D mm 354 x 1376 x 766 354 x 1876 x 766
UNIT WEI HT kg 27 UNIT WEI HT kg 45 70 70
CONDENSATE DRAIN SIZE mm 19.05 CONDENSATE DRAIN SIZE mm 19.05
PIPE CONNECTION mm 1 . BSP FEMALE THREAD ADAPTOR PIPE CONNECTION mm 19.05 BSP FEMALE THREAD ADAPTOR
ENTERING WATER 50°c (2 PIPES SYSTEM) ENTERING WATER 50°c (2 PIPES SYSTEM)
7°c 7°c
TEMPRATURE 70°c (4 PIPES SYSTEM) TEMPRATURE 70°c (4 PIPES SYSTEM)
LEAVING WATER LEAVING WATER
12°c 12°c
TEMPRATURE 60°c (4 PIPES SYSTEM) TEMPRATURE 60°c (4 PIPES SYSTEM)
ALL SPECIFICATIONS ARE SUB ECTED TO CHAN E B THE MANUFACTURER WITHOUT PRIOR NOTICE ALL SPECIFICATIONS ARE SUB ECTED TO CHAN E B THE MANUFACTURER WITHOUT PRIOR NOTICE
19 20
Ceiling Concealed Type
*
AL
pecification for Ceiling Concealed ype
MODEL FWC09C FWC11C FWC1 C FWC1 C FWC1 C
Btu/h 800 38000 3 000 00 51800
NOMINAL COOLIN CAPACIT
W 0 111 0 108 0 13100 15180
Btu/h 19 00 9800 9300 35100 0900
NOMINAL SENSIBLE COOLIN CAPACIT
W 5 0 8 30 8590 10 90 11990
INDOOR UNIT
› Easy To Service › alve Or alveless Control Option
› Left/Right Piping Option › Speed Fan Motor For Application Flexibility HEAD LOSS (COOLIN ) kPa 1 .0 39.0 3.0 38.0 51.0
› Wide Capacity Range HEAD LOSS (HEATIN ) 50 C kPa 11.0 3 .0 19.0 33.0 8.0
MA . WOR IN PRESSURE kPa 1 08
SURFACE AIR ELOCIT m/s 1. 0 1. 1.83 1.5 1.5
pecification for Ceiling Concealed ype
SOUND PRESSURE LE EL (H/M/L) dBA / / 38 51 / 8 / 5 9/ 5/ 1 5 / 50 / 53 / 50 /
UNIT DIMENSION HXWXD mm 38 x 91 x 31 x 1 5 x 559 38 x 1003 x 38 x 1 8 x 38 x 1 8 x
MODEL FWC03C FWC0 C FWC0 C FWC0 C
PAC IN DIMENSION HXWXD mm 415 x 11 x 31 355 x 1 1x 15 x 1 5 x 31 15 x 1 9 x 31 15 x 1 01 x 31
Btu/h 9900 11 00 18000 500
NOMINAL COOLIN CAPACIT UNIT WEI HT kg 42 44 50 5
W 900 3 00 5 80 590
CONDENSATE DRAIN SI E mm 19.05
Btu/h 000 81 0 1 00 15 50
NOMINAL SENSIBLE COOLIN CAPACIT PIPE CONNECTION mm 19.05 BSP FEMALE THREAD ADAPTOR
W 050 380 3 90 0
NOMINAL HEATIN CAPACIT Btu/h 11500 15000 3000 9000 MODE COOLIN HEATIN
(ENTERIN WATER TEMP. 50 C) W 33 0 00 0 8500 ENTERIN AIR TEMPRATURE c DB / 19 c WB 0 c DB
50 c ( PIPES S STEM)
NOMINAL TOTAL INPUT POWER W 89 1 0 1 8 182 ENTERIN WATER
c
TEMPRATURE 0 c ( PIPES S STEM)
NOMINAL RUNNIN CURRENT A 0. 0 0. 5 0. 0.8
LEA IN WATER
0 0 / 1 / 50 1 c
POWER SOURCE /Ph/Hz TEMPRATURE 0 c ( PIPES S STEM)
REFRI ERANT T PE N/A ALL SPECIFICATIONS ARE SUB ECTED TO CHAN E B THE MANUFACTURER WITHOUT PRIOR NOTICE
AIR DISCHAR E DUCTED
CONTROL
OPERATION WIRED MICRO COMPUTER REMOTE CONTROL
HI H CFM 300 510 00 30
AIR FLOW MEDIUM CFM 285 90 5 0
LOW CFM 0 00 0 580
E TERNAL STATIC PRESSURE Pa 9/ /3 9/ / 8 9/ 5/ 1 9 / 3 / 30
US PM . 0 . 0 .05 5.0
NOMINAL WATER FLOW RATE
INDOOR UNIT
22
Ducted Blower Type
* *
AL
FUD20/25B FUD40/50B
23
Controller
BRC52A
BRC52A61 – Heatpump with auto mode
BRC52A62 – Cooling only
BRC52A63 - Heatpump
7 1. ertical Automatic Air Swing
. Selectable Mode
Auto Mode, Cooling , Heating, Dry, Fan
3. Turbo Function
. Quiet Function
8
5. ON Timer Se ng
1 9
2 . Real Time Clock
3 . Transmission Source
10
4 8. low in the dark ON/OFF Bu on
11
9. Fan Speed Selection Low, Med, High, Auto
5 12
10. Temperature Se ng Up & Down
6 11. Sleep Mode Function
1 . OFF Timer Se ng
BRC51A
BRC51A61 – Heatpump with auto mode
BRC51A62 – Cooling only
Features:
Cool/Heat/Fan/Dry/Auto mode
Auto/High/Med/Low fan speed
Temperature operate in C and F
Turbo and Quiet Function
Sleep function
Swing function
Real time clock and day display
days programmable timer
Error indicator
ey lock and fan lock features
Ba eries backup and retain se ng during power failure
Last state memory (Memory backup se ng from main board)
Delay Timer (1 or hours)
Interaction with Wireless Handset (BRC5 A 1/BRC5 A )
24
Standard Features
COMFORT FIN TYPE
Turbo Mode Rapid cooling/heating with
highest fan speed for immediate comfort AL Bare Aluminium Fin
Dry Mode eeping the room dehumidified, he outdoor models in the catalog comes with bare blue fin
while maintaining room temperature condenser. or gold fin outdoor models, specification remains
the same with the below model name change : eg :
Auto Mode Auto switching between cooling
and heating mode depending on room and set RYN25CXV1 to RYN25CGXV1 comes a er the series name
temperature of the outdoor.
Sleep Mode
Ionizer
25
upported Configuration
Intelligent Control Series BRC51A
Master Slave
BRC52A
Network Interface Module (NIM) is a networking system which enables communication among Daikin air conditioners.
With the Network Interface Module (NIM), all your air conditioning systems can be controlled with ust a single controller giving
you benefits Communication us Connection Recommended Maximum Cable Length (m)
Network Control NIM A way twisted pair cable is used as the First NIM to the furthest
1000
communication bus. Recommended cable for connected NIM
communication bus is a pair of screened & NIM to Main Board 10
enefits shielded, twisted single core wire with core
More convenience. No more individually controlling air conditioning units NIM to Wired Controller
Quicker and easier zone control from the master control unit
diameter of 0.5mm to 1.0mm. 10
Be er control of air conditioning systems operating conditions
Connection
NIM utilizes master slave type system whereby the master node will issue commands
to each of the slave nodes.
The communication bus must be connected serially to the ad acent NIM. (Daisy chain connection). The same
polarity has to be connected between the NIMs (A to A, B to B).
Every master unit will have a group address so that every slave can only response to
their respective master. Each slave unit must have a unique address so that it can be
addressed independently of other nodes.
G-Way
The master unit will be operating in con unction with a control panel. Any se ngs
done via the control panel connected to the master will overwrite the se ngs of its
slave units. unction
Slave unit can be operated with or without control panel. If a slave unit is operating ateway between fan coil unit and basic Building
with a control panel, its se ngs can be changed without following its master. NIM Management System (BMS).
ypes of peration e ng
Connection
Control & Monitor (Ext. Switch Closed = ON A/C) 0000
Control & Monitor (Ext. Switch Open = ON A/C) 0010
Monitoring only 0001
e ng
(up to total of
16 FCUs)
To Wired Control Panel
S-NIM
eatures
Auto restart feature with last state se ngs.
air conditioning units in a master & slave system, operating at alternate sequence of preset time (3/ /5/ /9/11/1 hours).
System controlled by a single BRC51A controller.
When the operating unit is at fault, the standby unit automatically takes over.
Error indication via error code displayed on LCD panel. (only is using Netware 3 control panel)
During system OFF mode, running timer will stop. It resumes when changing to ON mode.
Preset operation hours can be set via DIP Switch.
The air conditioning unit connected to the wired controller is always the master unit.
he ystem Consists f
Main Board controller S NIM controller
BRC51A Communication Bus
Communication us
A way twisted pair cable is used as the communication bus.
Recommended cable for communication bus is a pair of screened & shielded, twisted single core wire with core diameter
of 0.5mm to 1.0mm.
Controller Application
Server Room Laboratory
Telecommunication Tower Railway Switching Center
Livestock Breeding Farm Room with Critical Electronics Equipments
Warehouse
S-NIM S-NIM
Slave Unit
Control Panel
Master Unit
ypical connection structure for
28