PCXCW15

Air Cooled
PRODUCT SYSTEM
Application
Air Cooled ini
Chiller
an Coil nit

Chilled Water System


Solution Product Catalogue

Products manufactured in an certified facility.


his document contains the most current product information as of this printing.
@2014-12

Printed n alaysia
Contents Products Overview
kW
Cooling & Heating Capacity
4.0 6.0 8.0 10.0 15.0 20.0 25.0 30.0 40.0 50.0

R22 020/025/030/040/050/060/080/100/120/150

UAE 020/025/030/040/050/060/080/100/120/150
Application
025/030/040/050/060/080/100/120/150

01 R407C
UAP 060/080/100/120/150

020/025/030/040/050/055

Air Cooled Mini Chiller R410A


UAQ 020/025/030/040/050/055

04

FWE-E
Fan Coil Units

FWC-C
14 15 16 17 19
Wall Mounted Ceiling Casse e Ceiling Casse e Ceiling Casse e Ceiling Convertible
Compact Type (600 x 600) Type (900 x 900) Type (900 x 900) Type
With Brushless DC Motor

20 21 23
Ceiling Convertible Ceiling Concealed Type Ducted Blower Type
Type

Remark: All unit photos in this catalog are solely for illustration purpose, actual outlook may differ slightly.
All specifications are subjected to change by the manufacturer without prior notice.
Application

AIR COOLED MINI CHILLER APPLICATION EXAMPLES :

Pri ate Houses ym Centres ni ersities & Halls

Availablility of
cooling only
& heatpump
models
Hotels ce ooms @ Coffee Houses

estaurant

CHILLED WATER SYSTEM


SOLUTION ADVANTAGES :

ong Piping
Application

imple n ite uiet peration


nstallation

Chilled Water
ystem olution
Ad antages

ersatility n ess efrigerant


Multiple temprature Serviceability & Error Dry Contact BMS ystem Coupling Handling
Centralized Control Master/Slave Option
Zone Control Code Troubleshooting Compatibility
Network supports up Operation can be managed Easy access for servicing Control based on Ability to be integrated
to 50 chillers according to zones for all components. Error code network grouping or with BMS
different comfort need displayed on control panel application
o ecessity o
for troubleshooting se Cooling owers
purpose

LONG PIPING APPLICATION


aikin chilled water system has no limitation in piping lengths unlike direct e pansion
refrigerant system. As long as the water pump head pressure is su cient to pump the
water through the water pipe network, the chiller can be installed far away from the fan
coil units. aikin ini Chiller is designed to support water operating pressure up to
kPa. ith such high design pressure, aikin mini chiller is capable of fulfiling n the
case where the ini Chiller s built in pump head is insu cient to support the o erall
friction loss, additional pump can be installed to cater for higher pump head re uirement.

1 2
Air Cooled
QUIET OPERATION VERSATILITY IN SYSTEM COUPLING
Quiet operation due to fan coil units Chilled water system is designed with versatility in system
and chiller can be placed far away coupling where there is no limitation in the number of

Mini Chiller
from room fan coil unit coupling with mini chiller as long as they meet
the designed capacity requirament & water flow rate.
System coupling of one to one and one to many
configurations

Mini chiller can be installed


far away from fan coil units ONE TO ONE

LESS REFRIGERANT HANDLING


EASY INSTALLATION AND MAINTENANCE :
› Less Refrigerant Handling
› No Refrigerant Used In Occupied Space INTEGRATED HYDRONIC COMPONENTS
› Water As Cooling Medium
Daikin Mini Chiller is fully integrated and equipped with key
Refrigerant is only circulating within the mini chiller hydronic components such as expansion tank, water tank,
unit. Meanwhile, water acts as the cooling medium brazed plate heat exchanger and water circulating pump. As Brazed Plate Heat Exchanger
for FCU. When there is less refrigerant used, the all hydronic components are assembled and tested in the
Plate type heat exchanger has a
scope of care on refrigerant handling is smaller. In factory, installation of additional component on site can be compact structure and a high level
case when there is a leak water is definitely easier eliminated. of heat exchange efficiency
to handle in term of process and cost.
ONE TO MANY
NO NECESSITY TO USE COOLING TOWERS MULTISTAGE END SUCTION
WATER PUMP Diaphragm Expansion Tank
Daikin mini chiller is designed for air cooled
application where is no necessity to use Impeller and all movable parts Prevent damage of hydraulic
components and cracking of
the cooling tower especially for small and in contact with the water are
piping due to expansion of hot
medium size of chilled water application made of stainless steels.
water in the pipes.

WATER STORAGE TANK


Prevent the compressor from
switching ON/OFF too frequently
FILTER DRIER during low load conditions such as
Remove dirt and moisture in night time.
the refrigerant circuit. NOTE:
Model UA(E/P)080~150C/CR water
tank is offered as an optional device.
SIMPLE ON SITE INSTALLATION

The Daikin mini chiller is fully assembled, complete FACTORY PRECHARGED REFRIGERANT
with all necessary components in one unit like water
Each heat exchanger in the chiller is brazed
pump, internal wiring, fully charged with refrigerant SERVICEABILITY & ERROR CODE FOR EASE OF
and undergo strict testing and quality check before and tested against leakages through dried air
TROUBLESHOOTING
delivery. Only connection to water piping and power at 30 bars. After that, another process of
supply is required at site. system vacuuming is done before it is By opening the front panel, one can access and service all the
components in the chiller. The chiller is equipped with self
accurately charged with refrigerant to ensure
diagnosis function which allow the chiller panel to display total of
optimum performance. Thus, it saves the 19 type of faulty occurred in the system by showing different
hustles of field charging by installers. error code on the LCD screen of the panel.

Refrigarent

3 4
PARALLEL INSTALLATION MICROPROCESSOR CONTROL SAFETY PROTECTION
Daikin Mini Chiller provides flexibility in adding Daikin chillers are equipped with microprocessor The safety protections provided for the Daikin chiller
capacity for building extension. This can be done controller that will control and regulate the operation are
by installing the mini chiller in parallel of the unit. High & Low Pressure Switches
connection. Anti Freeze Protection Sensor
Besides that, the controller that contains the well Discharge Temperature Sensor
A network of up to 50 chillers is possible to be
developed algorithm will provide protection to the Over Pressure Relief alve
connected in a system. For ease of controlling
chiller by accurately sensing the key temperatures in Water Pressure Differential Switch
and se ng, Daikin Mini Chiller panel can be used both the water and refrigerant circuit. Should there be Anti Freeze Heater on BPHE
as either Master or Slave. This function allows any abnormal reading received by controller, an alarm Compressor Water Pump & Fan Motor Overload
user to monitor all the se ngs on the slave units signal will be sent to chiller panel, followed by Protector
at the master unit. protection action plans such as to stop the operation
of compressor, condenser fan motor or circulating
water pump.
Supported Up To 50 Units Of Chiller
Chiller 0 Chiller 1 Chiller 2
BRAZED PLATE HEAT EXCHANGER (BPHE)
The heat exchanger is
made of AISI 31
stainless steel plates
closely arranged and
brazed together to
5 way wire (CM8)
Chiller
maximize possible
Chiller Panel 0 Chiller Panel 1 Communication us heat exchange
efficiency.
A stainless steel PH

P A
C C A P A C
State-Of-The-Art Components
CHILLER CONTROL PANEL The display is shown in an 8 lines graphical LCD
SCROLL COMPRESSOR ANTI-FREEZE PROTECTION display. There are 8 dedicated keys available in the
The chiller panel controller is designed to control the
panel.
Scroll Compressors are used for the units to offer a The chiller unit has several anti freeze protection chiller operation. This device allows the user to have
Menu selection.
quieter and more reliable performance over a wide features customized control for each connected unit.
Navigation on the screen.
operating temperature range. (Except UAE0 0C/CR
1. Built in heater in BPHE Modification of the selected value.
which uses rotary compressor). Each chiller will have a chiller control panel that
The BPHE has a strip heater around it to prevent water
comes as a standard accessory. At the same time, the
freezing inside.
For UA(E/P) 030, 0 0, 050, 0 0, 080, 100, 1 0, 150 chiller control panel is able to be installed remotely
CR, phase protector is provided to prevent the . Anti Freeze sensor through the cable up to a distance of 100 meters.
compressor from rotating in the wrong directions. BPHE can avoid the frosting as the anti freeze sensor Example, the chiller panel can be installed in a
will send the signal to cut out the compressor if the centralized plant control room for the building.
water temperature becomes too cold.
Copeland 3. Water pressure differential switch The chiller control panel has been designed taking into
Compliant
This protection feature will ensure there is water flow consideration of the user friendly and yet versatile
Scrolls
in pipings when the chiller is in operation. Otherwise, control features.
High Efficiency
the compressor will cut out immediately.
Motor
Features
Whole system configuration.
Quiet Shutdown Unique parameter se ngs.
Device
Operation status display.
Tracing fault record (offer quick troubleshooting
solutions).

5 6
LOAD BALANCING CONTROL ANTI CORROSION GOLD ALUMINUM FIN
FLEXIBILITY :
For UA(E/P)080 ~ 150 C/CR both compressors will old Aluminum fin is offered as the standard material
cut in and cut out depending on their of the condenser heat exchanger of this series of
TRUE DUAL CIRCUITS BPHE
accumulative operating time. This sequencing chiller.
control feature will ensure no single compressor is Apply sophisticated technology of true dual circuit
overload in operation as well as to ensure longer BPHE.
reliability of compressors.
The true dual BPHE puts the secondary circuit
CAPACITY STEP CONTROL (water) in contact with 2 primary circuits
UA(E/P)080 ~ 150 C/CR has been designed with two (refrigerant). So even if one primary circuit is shut
separate refrigerant circuits, i.e. it has two off, each secondary channel is still in contact with a
compressors. By doing so, the unit has part loading primary channel. These advantages have made the
capabilities, i.e. 0 50 100 of rated capacity. This will product the natural choice for flexible chillers,
improve the reliability and energy efficiency of the climate control applications and high precision
unit, especially during low loading operations. systems food cooling cabinets in supermarkets.

Ref.1 Ref.2 Ref.1 Ref.2 Ref.1

EFFICIENCY AND PERFORMANCE :

water water water water


BETTER PERFORMANCE
Usage of higher efficient R 10A rotary compressors
Air-Cooled Mini Chiller in tandem configuration
Tight tolerances between moving parts resulting in PARALLEL INSTALLATION
Model: UAQ 030/040/050/055 CR high compressor volumetric efficiency A network up to 50 chillers in a system is possible.
Minimize mechanical losses Control on the operation of the chillers will be done
This innovative air cooled chiller by Daikin
Minimize gas flow losses and turbulence through the microprocessor controller. The external
was designed with one purpose in mind,
Optimize compressor oil return water piping connection can be made either from
which is to offer cost and energy saving for
users. the left or right side of the unit.
CAPACITY STEP CONTROL
3 steps compressor loading (0 0 0 100 ) for
UAQ 0 0 CR & UAQ 050 CR

steps compressor loading (0 50 100 ) for


UAQ 030 CR & UAQ 055 CR

ELIMINATION OF WATER TANK


Combining the Tandem Compressors technology
with the algorithm of the microprocessor control,
water tank can be eliminated in most instances.
Chiller Panel Comes As
CHOICES OF SINGLE PHASE AND The Standard Controller
3 PHASE POWER SUPPLY CONNECTION
Usage of single phase power supply compressors
and circulating water pump.
Offers flexibility to field installation.

7 8
R22 AIR COOLED MINI CHILLER SPECIFICATION
R22 COOLING MODEL R22 HEATPUMP MODEL
MODEL UAE020C UAE025C UAE030C UAE040C UAE050C UAE060C MODEL UAE020CR UAE025CR UAE030CR UAE040CR UAE050CR UAE060CR
Btu/h 20,000 24,200 30,000 39,500 48,500 54,000 Btu/h 19,000 23,000 27,500 38,000 44,000 50,000
NOMINAL COOLING CAPACITY NOMINAL COOLING CAPACITY W 5,570 6,740 8,060 11,140 12,900 14,650
W 5,860 7,090 8,790 11,580 14,210 15,830
NORMAL TOTAL INPUT POWER COOLING W 2,650 2,680 3,540 4,490 5,080 5,770 Btu/h 22,000 27,000 35,000 43,000 50,000 55,000
NOMINAL HEATPUMP CAPACITY
NORMAL RUNNING CURRENT COOLING A 12.25 12.17 16.41 9.67 9.75 12.01 W 6,450 7,910 10,260 12,600 14,650 16,120
EER W/W 2.21 2.65 2.48 2.58 2.80 2.74 COOLING W 2,530 2,670 3,440 4,230 5,190 5,580
NORMAL TOTAL INPUT POWER
HEATPUMP W 2,600 2,790 3,430 4,390 5,100 5,320
REFRIGERANT CONTROL (EXPENSION DEVICE) CAPILLARY TUBE
REFRIGERANT CHARGE kg 1.25 1.80 1.88 2.80 3.15 3.30 COOLING A 11.78 12.17 17.27 9.05 9.77 12.60
NORMAL RUNNING CURRENT
POWER SOURCE (OUTDOOR) V/Ph/Hz 220-240/1/50 380-415/3/50 HEATPUMP A 11.62 12.70 17.25 9.14 9.72 11.50
REFRIGERANT TYPE R22 EER W/W 2.20 2.52 2.34 2.63 2.48 2.63
SOUND PRESSURE LEVEL dBA 57 57 58 59 59 59 COP W/W 2.48 2.84 2.99 2.87 2.87 3.03
UNIT DIMENSION HEIGHT X WIDTH X DEPTH mm 790 x 1,160 x 460 1,140 x 1,160 x 460 REFRIGERANT CONTROL (EXPENSION DEVICE) CAPILLARY TUBE
PACKING HEIGHT X WIDTH X DEPTH mm 920 x 1,270 x 570 1,551 x 1,270 x 570 REFRIGERANT CHARGE kg 1.43 1.75 1.83 3.50 4.10 4.00
UNIT WEIGHT kg 116 123 126 188 189 196 POWER SOURCE (OUTDOOR) V/Ph/Hz 220-240/1/50 380-415/3/50
NOMINAL WATER FLOW RATE COOLING I/s/m3/hr 0.29 / 1.03 0.33 / 1.20 0.42 / 1.51 0.53 / 1.90 0.67 / 2.40 0.76 / 2.73 REFRIGERANT TYPE R22
INDOOR UNIT

TYPE ROTARY SCROLL SOUND PRESSURE LEVEL dBA 57 57 58 59 59 60


COMPRESSOR
STAGE OF CAPACITY CONTROL 0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100% UNIT DIMENSION HEIGHT X WIDTH X DEPTH mm 790 x 1,160 x 460 1,140 x 1,160 x 460
TYPE THREAED PACKING HEIGHT X WIDTH X DEPTH mm 920 x 1,270 x 570 1,551 x 1,270 x 570
PIPING CONNECTION mm 25.4 UNIT WEIGHT kg 116 123 128 195 197 203
HEAD COOLING kPa 79 92 86 114 90 92 COOLING I/s/m3/hr 0.26 / 0.93 0.31 / 1.12 0.39 / 1.39 0.56 / 2.00 0.62 / 2.20 0.64 / 2.50

INDOOR UNIT
NOMINAL WATER FLOW RATE
CAPACITY / VOLUME L 22 40 HEATPUMP I/s/m3/hr 0.31 / 1.12 0.38 / 1.38 0.49 / 1.75 0.56 / 2.00 0.62 / 2.20 0.76 / 2.72
TANK
MATERIAL MILD STEEL WITH ZINC TYPE ROTARY SCROLL
COMPRESSOR
STAGE OF CAPACITY CONTROL 0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100%
TYPE THREAED
MODEL UAE080C UAE100C UAE120C UAE150C
CONNECTION mm 25.4
Btu/h 85,000 95,000 116,000 138,000 PIPING 110
NOMINAL COOLING CAPACITY COOLING kPa 79 94 92 118 104
W 24,910 27,840 34,000 40,450 HEAD
HEATPUMP kPa 79 86 73 103 85 87
NORMAL TOTAL INPUT POWER COOLING W 8,870 10,590 11,370 14,220
TANK CAPACITY / VOLUME L 22 40
NORMAL RUNNING CURRENT COOLING A 17.00 18.50 25.80 31.80 MATERIAL MILD STEEL WITH ZINC
EER W/W 2.81 2.63 2.99 2.84
REFRIGERANT CONTROL (EXPENSION DEVICE) TXV
REFRIGERANT CHARGE kg 3.90 x 2 4.60 x 2 6.00 x 2 7.10 x 2
POWER SOURCE (OUTDOOR) V/Ph/Hz 380-415/3/50 MODEL UAE080CR UAE100CR UAE120CR UAE150CR
REFRIGERANT TYPE R22 Btu/h 80,000 95,000 113,000 138,000
SOUND PRESSURE LEVEL dBA 63 63 67 67 NOMINAL COOLING CAPACITY W 23,450 27,840 33,120 40,450
UNIT DIMENSION HEIGHT X WIDTH X DEPTH mm 1,245 x 1,500 x 900 1,245 x 1,800 x 1,150 Btu/h 95,000 105,000 120,000 132,000
NOMINAL HEATPUMP CAPACITY
PACKING HEIGHT X WIDTH X DEPTH mm 1,452 x 1,732 x 1,032 1,452 x 2,032 x 1,282 W 27,840 30,770 35,170 38,690
INDOOR UNIT

UNIT WEIGHT kg 340 340 480 560 COOLING W 8,490 11,100 12,070 14,320
NORMAL TOTAL INPUT POWER
NOMINAL WATER FLOW RATE COOLING I/s/m3/hr 1.22 / 4.40 1.36 / 4.90 1.67 / 6.00 2.00 / 7.20 HEATPUMP W 8,750 10,310 12,370 15,020
TYPE SCROLL COOLING A 18.40 18.90 26.60 31.40
COMPRESSOR NORMAL RUNNING CURRENT
STAGE OF CAPACITY CONTROL 0 - 50 - 100% 0 - 50 - 100% 0 - 50 - 100% 0 - 50 - 100% HEATPUMP A 18.90 17.10 26.80 32.20
TYPE THREAED EER W/W 2.76 2.51 2.74 2.82
PIPING CONNECTION mm 31.75 COP W/W 3.18 2.98 2.86 2.58
HEAD COOLING kPa 229 229 188 157 REFRIGERANT CONTROL (EXPENSION DEVICE) CAPILLARY TUBE
REFRIGERANT CHARGE kg 5.00 x 2 5.40 + 5.30 7.60 x 2 6.50 x 2
ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE POWER SOURCE (OUTDOOR) V/Ph/Hz 380-415/3/50
ALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT) REFRIGERANT TYPE R22
SOUND PRESSURE LEVEL dBA 63 63 67 67
TEMPERATURE COOLING HEATING UNIT DIMENSION HEIGHT X WIDTH X DEPTH mm 1,245 x 1,500 x 900 1,245 x 1,800 x 1,150

ENTERING 12°C 40°C PACKING HEIGHT X WIDTH X DEPTH mm 1,452 x 1,732 x 1,032 1,452 x 2,032 x 1,282
EVAPORATOR UNIT WEIGHT kg 340 340 480 560

INDOOR UNIT
LEAVING 7°C 45°C I/s/m3/hr
COOLING 1.13 / 4.05 1.33 / 4.80 1.67 / 6.00 2.00 / 7.20
NOMINAL WATER FLOW RATE
CONDENSOR AMBIENT 35°C 7°C / 6°C HEATPUMP I/s/m3/hr 1.13 / 4.05 1.33 / 4.80 1.67 / 6.00 2.00 / 7.20
SCROLL
COMPRESSOR
STAGE OF CAPACITY CONTROL 0 - 50 - 100% 0 - 50 - 100% 0 - 50 - 100% 0 - 50 - 100%
TYPE THREAED
CONNECTION mm 31.75
PIPING COOLING kPa 254 173 188 157
HEAD
HEATPUMP kPa 229 144 188 157

ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE
ALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)

TEMPERATURE COOLING HEATING


ENTERING 12°C 40°C
EVAPORATOR
LEAVING 7°C 45°C
CONDENSOR AMBIENT 35°C 7°C / 6°C

9 10
R407C AIR COOLED MINI CHILLER SPECIFICATION R407C HEATPUMP MODEL
R407C COOLING MODEL MODEL UAP060CR UAP080CR UAP100CR UAP120CR UAP150CR
Btu/h 50,000 74,000 87,500 110,000 130,000
MODEL UAP025C UAP030C UAP040C UAP050C UAP060C NOMINAL COOLING CAPACITY W 14,650 21,690 25,640 32,240 38,100
Btu/h 23,000 26,900 38,500 47,000 50,000 Btu/h 55,000 90,000 96,000 118,000 144,000
NOMINAL COOLING CAPACITY NOMINAL HEATPUMP CAPACITY
W 6,740 7,880 11,280 13,920 14,650 W 16,120 26,380 28,140 34,580 42,200
NORMAL TOTAL INPUT POWER COOLING W 2,950 3,770 4,680 5,430 6,040 COOLING W 6,280 8,990 11,100 12,630 15,900
NORMAL TOTAL INPUT POWER
NORMAL RUNNING CURRENT COOLING A 13.30 17.41 9.62 10.20 11.28 HEATPUMP W 5,570 9,350 11,110 12,750 16,100
EER W/W 2.29 2.09 2.41 2.56 2.43 NORMAL RUNNING CURRENT COOLING A 11.60 18.90 19.00 27.10 34.40
HEATPUMP A 11.50 19.00 19.10 26.70 34.80
REFRIGERANT CONTROL (EXPENSION DEVICE) CAPILLARY TUBE 2.55
EER W/W 2.33 2.41 2.31 2.40
REFRIGERANT CHARGE kg 1.72 1.63 3.00 3.30 3.20 COP W/W 2.82
2.89 2.53 2.71 2.62
POWER SOURCE (OUTDOOR) V/Ph/Hz 220-240/1/50 380-415/3/50 REFRIGERANT CONTROL (EXPENSION DEVICE) CAPILLARY TUBE
REFRIGERANT TYPE R407C REFRIGERANT CHARGE kg 4.00 3.70 X 2 4.80 + 4.70 5.80 x 2 6.40 x 2
SOUND PRESSURE LEVEL dBA 57 58 59 59 60 POWER SOURCE (OUTDOOR) V/Ph/Hz 380-415/3/50
UNIT DIMENSION HEIGHT X WIDTH X DEPTH mm 790 x 1,160 x 460 1,140 x 1,160 x 460 REFRIGERANT TYPE R407C
mm 920 x 1,270 x 570 1,551 x 1,270 x 570 SOUND PRESSURE LEVEL dBA 60 63 63 67 67
PACKING HEIGHT X WIDTH X DEPTH
UNIT DIMENSION HEIGHT X WIDTH X DEPTH mm 1,140 x 1,160 x 460 1,245 x 1,500 x 900 1,245 x 1,800 x 1,150
UNIT WEIGHT kg 123 126 188 189 196
INDOOR UNIT

PACKING HEIGHT X WIDTH X DEPTH mm 1,551 x 1,270 x 570 1,452 x 1,732 x 1,032 1,452 x 2,032 x 1,282
NOMINAL WATER FLOW RATE COOLING I/s/m3/hr 0.31 / 1.11 0.38 / 1.36 0.53 / 1.90 0.64 / 2.30 0.69 / 2.50 UNIT WEIGHT kg 203 340 340 480 560

INDOOR UNIT
TYPE SCROLL COOLING I/s/m3/hr 0.64 / 2.30 1.03 / 3.70 1.25 / 4.50 1.67 / 6.00 1.89 / 6.80
COMPRESSOR NOMINAL WATER FLOW RATE 1.25 / 4.50
STAGE OF CAPACITY CONTROL 0 - 100% 0 - 100% 0 - 100% 0 - 100% 0 - 100% HEATPUMP I/s/m3/hr 0.78 / 2.80 1.03 / 3.70 1.67 / 6.00 1.89 / 6.80
TYPE THREAED COMPRESSOR TYPE SCROLL
STAGE OF CAPACITY CONTROL 0 - 100% 0 - 50 -100% 0 - 50 -100% 0 - 50 -100% 0 - 50 -100%
PIPING CONNECTION mm 25.4
TYPE THREAED
HEAD COOLING kPa 94 93 117 93 110 CONNECTION mm 25.4 31.75
CAPACITY / VOLUME L 22 40 PIPING
COOLING kPa 110 263 193 188 172
TANK HEAD HEATPUMP 238 170 172
MATERIAL MILD STEEL WITH ZINC kPa 87 188

ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE
MODEL UAP080C UAP100C UAP120C UAP150C ALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)
Btu/h 80,000 90,000 115,000 137,000
NOMINAL COOLING CAPACITY TEMPERATURE COOLING HEATING
W 23,450 26,380 33,730 40,150
NORMAL TOTAL INPUT POWER COOLING W 9,430 11,210 12,170 14,970 ENTERING 12°C 40°C
NORMAL RUNNING CURRENT COOLING A 18.00 19.22 26.50 33.00 EVAPORATOR
EER W/W 2.49 2.35 2.77 2.68 LEAVING 7°C 45°C
CONDENSOR AMBIENT 35°C 7°C / 6°C
REFRIGERANT CONTROL (EXPENSION DEVICE) TXV
REFRIGERANT CHARGE kg 3.90 x 2 3.80 x 2 5.60 x 2 6.00 x 2
POWER SOURCE (OUTDOOR)
REFRIGERANT TYPE
V/Ph/Hz 380-415/3/50
R407C
R410A AIR COOLED MINI CHILLER SPECIFICATION
SOUND PRESSURE LEVEL dBA 63 63 67 67
UNIT DIMENSION HEIGHT X WIDTH X DEPTH mm 1,245 x 1,500 x 900 1,245 x 1,800 x 1,150 R410A HEATPUMP MODEL
PACKING HEIGHT X WIDTH X DEPTH mm 1,452 x 1,732 x 1,032 1,452 x 2,032 x 1,282
UNIT WEIGHT kg 340 340 480 560 MODEL UAQ020CR UAQ025CR UAQ030CR UAQ040CR UAQ050CR UAQ055CR
INDOOR UNIT

NOMINAL WATER FLOW RATE COOLING I/s/m3/hr 1.14 / 4.10 1.25 / 4.50 1.67 / 6.00 2.00 / 7.20 Btu/h 15,700 21,000 24,800 34,000 41,600 45,000
NOMINAL COOLING CAPACITY
TYPE SCROLL W 4,600 6,150 7,270 10,000 12,200 13,200
COMPRESSOR Btu/h 21,500 25,000 32,500 43,000 48,000 55,000
STAGE OF CAPACITY CONTROL 0 - 50 - 100% 0 - 50 - 100% 0 - 50 - 100% 0 - 50 - 100% NOMINAL HEATPUMP CAPACITY
TYPE THREAED W 6,300 7,330 9,530 12,600 14,070 16,120
COOLING W 2,620 2,760 3,830 5,000 5,310 5,490
PIPING CONNECTION mm 31.75 NORMAL TOTAL INPUT POWER
HEATPUMP W 2,590 2,790 3,630 4,650 5,150 5,440
HEAD COOLING kPa 229 229 188 157 COOLING A 11.76 12.70 16.68 7.44 7.90 8.18
NORMAL RUNNING CURRENT
HEATPUMP A 11.93 12.90 16.32 7.20 7.83 8.38
ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE EER W/W 1.76 2.23 1.90 2.00 2.30 2.40
ALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT) COP W/W 2.43 2.63 2.62 2.71 2.73 2.96
REFRIGERANT CONTROL (EXPENSION DEVICE) CAPILLARY TUBE CAPILLARY TUBE & TXV
TEMPERATURE COOLING HEATING REFRIGERANT CHARGE kg 1.20 1.725 2.20 4.30 4.20 4.30
POWER SOURCE (OUTDOOR) V/Ph/Hz 220-240/1/50 380-415/3/50
ENTERING 12°C 40°C REFRIGERANT TYPE R410A
EVAPORATOR
LEAVING 7°C 45°C SOUND PRESSURE LEVEL dBA 58 59 57 59 59 61
UNIT DIMENSION HEIGHT X WIDTH X DEPTH mm 790 x 1,200 x 460 790 x 1,050 x 460 1,140 x 1,060 x 460
CONDENSOR AMBIENT 35°C 7°C / 6°C PACKING HEIGHT X WIDTH X DEPTH mm 950 x 1,310 x 574 950 x 1,204 x 574 1,566 x 1,204 x 574
UNIT WEIGHT 3
kg 128 128 128 195 195 195

INDOOR UNIT
NOMINAL WATER FLOW RATE COOLING I/s/m3/hr 0.24 / 0.86 0.28 / 1.00 0.42 / 1.50 0.50 / 1.80 0.60 / 2.15 0.75 / 2.70
HEATPUMP I/s/m3/hr 0.32 / 1.16 0.35 / 1.25 0.42 / 1.50 0.50 / 1.80 0.60 / 2.15 0.75 / 2.70
TYPE ROTARY TANDEM ROTARY
COMPRESSOR STAGE OF CAPACITY CONTROL 0-100% 0-100% 0-50-100% 0-40-60-100% 0-40-60-100% 0-50-100%
TYPE THREADED
CONNECTION mm 25.4
PIPING
COOLING kPa 90 98 93 90 74 70
HEAD
HEATPUMP kPa 73 90 80 71 64 53
CAPACITY / VOLUME L 22 N/A
TANK
MATERIAL MILD STEEL WITH ZINC N/A

ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE
ALL UNIT ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT)

TEMPERATURE COOLING HEATING


ENTERING 12°C 40°C
EVAPORATOR
LEAVING 7°C 45°C
CONDENSOR AMBIENT 35°C 7°C / 6°C

11 12
Wall Mounted Type
AL

ireless emote Controller ired emote Controller


To complement the air cooled chillers range, Daikin is offering an extensive range of FWW-L C A C A ption

chilled water fan coil units that will meet most of indoor application requirements
covering residential, light commercial and commercial. › Stylish Front Panel › NIM Able
› Comfortable Air Flow & Lower Sound Level › Sleep Funtion For Cool & Heat Mode
› Indoor Quiet Mode › Auto Restart With Last State Memory
The aesthetically a ractive decorative fan coil units such as Wall Mounted models, › Turbo Mode › lave & laveless Control Options
Ceiling Casse e and Ceiling Convertible are compact and ergonomic, the ranges › Uniform Air Distribution › Self Diagnosis Features
› Easy Maintenance › Compact & Easy To Use Wireless Remote Controller
can blend in easily to any interior designs whether it is residential houses, office, › Wide Capacity Range › Microprocessor Control
restaurant or shops. › 5 Selectable Fan Speed › Automatic Air Swing

In addition, the Daikin chilled water fan coil units are designed with easy
pecification for all ounted ype
installation and easy servicing in mind. The fan coil units also include the
microprocessor controller that has built in algorithm to control the operation of the MODEL FWW02L FWW03L FWW04L FWW05L FWW06L
fan coil unit as well as to provide protection to the unit. NOMINAL COOLIN CAPACIT
Btu/h 8300 9200 11300 15500 18000
W 2430 2700 3310 4540 5280
Btu/h 6300 6900 9000 11700 14000
NOMINAL SENSIBLE COOLIN CAPACIT
W 1850 2020 2640 3430 4100
NOMINAL HEATIN CAPACIT Btu/h 11000 12000 15000 20500 25000
(ENTERIN WATER TEMP. 50 C) W 3220 3520 4400 6010 7330
NOMINAL TOTAL INPUT POWER W 31 32 42 57 72
NOMINAL RUNNIN CURRENT A 0. 0 0. 0 0. 1 0.30 0.3
POWER SOURCE /Ph/Hz 0 0 / 1 / 50
REFRI ERANT T PE N/A
AIR DISCHAR E AUTOMATIC LOU ER (UP & DOWN)
CONTROL
OPERATION LCD WIRELESS MICRO COMPUTER REMOTE CONTROL
HI H CFM 260 280 370 510 620
MEDIUM CFM 230 250 320 450 520
AIR FLOW
LOW CFM 200 220 260 390 460
QUIET CFM 180 190 240 360 440
US PM 1.85 .03 .51 3. 3 .01
NOMINAL WATER FLOW RATE
litres/min .00 . 8 9.50 13.00 15.18

INDOOR UNIT
HEAD LOSS (COOLIN ) kPa 3 .0 .0 31.0 30.0 3 .0
HEAD LOSS (HEATIN ) 50 C kPa 9.0 0.0 5.0 .0 33.0
MA . WOR IN PRESSURE kPa 1608
SURFACE AIR ELOCIT m/s 0. 8 0. 0.9 0.83 1.01
SOUND PRESSURE LE EL (H/M/L/Q) dBA 3 / 9/ 5/ 35 / 30 / 5 / / 39 / 3 / 9 / 38 / 3 / 3 / / 39 / 3
UNIT DIMENSION H W D mm 88 800 0 310 10 5
PAC IN DIMENSION H W D mm 3 x8 x 38 113 31
UNIT WEI HT kg 9 14
CONDENSATE DRAIN SI E mm 19.05
PIPE CONNECTION mm 1 . 0 BSP FEMALE THREAD ADAPTOR

MODE COOLIN HEATIN


ENTERIN AIR TEMPRATURE c DB / 19 c WB 0 c DB

ENTERIN WATER 50 c ( PIPES S STEM)


c
TEMPRATURE 0 c ( PIPES S STEM)
LEA IN WATER
1 c
TEMPRATURE 0 c ( PIPES S STEM)
ALL SPECIFICATIONS ARE SUB ECTED TO CHAN E B THE MANUFACTURER WITHOUT PRIOR NOTICE

13 14
Ceiling Casse e Compact ype Ceiling Casse e ype
* *
AL AL

FWK-E ireless emote Controller ired emote Controller


C A C A ption
FWF-C ireless emote Controller ired emote Controller
C A C A ption

› Modern & Elegant Panel › Branch Duct Connection


› Optimum Air Discharge › Low Height Design
› Automatic Air Swing › Superior Sound Level
› Compact Design › Branch Duct Connection › 4 Way Air Discharge & Air Swing › Sleep Function For Cool & Heat Mode
› Fresh Air Intake › Sleep Function For Cool & Heat Mode › Multi Comfort 3 Air Swing Pa ern Control › Auto Restart With Last-State-Memory
› Built In High Head Drain Oump & Water Flow Switch › Auto Restart With Last-State-Memory › Fresh Air Intake › NIM-Able
› 4 Way Air Discharge & Air Swing › NIM-Able › Built In High Head Drain Oump & Water Flow Switch › Choice Of Wired Or Withless Remote Controller
› alve Or alveless Control Options › Choice Of Wired Or Withless Remote Controller › alve Or alveless Control Options › Self Diagnosis Features
› 3 Selectable Fan Speed › Automatic Air Swing › 4 Selectable Fan Speed › Microprocessor Control
› Microprocessor Control
pecification for Ceiling Casse e ype
MODEL
pecification for Ceiling Casse e Compact ype Btu/h 21000 25000 30000 38000 43000
NOMINAL COOLING CAPACITY
MODEL C C C W 6150 7330 8790 11140 12600
Btu/h 8500 14000 15500 Btu/h 16700 19200 22300 27400 31000
NOMINAL COOLING CAPACITY NOMINAL SENSIBLE COOLING CAPACITY
W 2490 4100 4540 W 4890 5630 6540 8030 9090

Btu/h 6500 10000 11500 NOMINAL HEATING CAPACITY Btu/h 28000 33600 38300 45500 52000
NOMINAL SENSIBLE COOLING CAPACITY (ENTERING WATER TEMP. = 50°C)
W 1910 2930 3370 W 8210 9850 11230 13340 15240

Btu/h 12000 16000 18000 NOMINAL TOTAL INPUT POWER W 95 126 167 186 227
NOMINAL HEATING CAPACITY
(ENTERING WATER TEMP. = 50°C) W 3520 4690 5280 NOMINAL RUNNING CURRENT A 0.44 0.55 0.74 0.85 1.03

NOMINAL TOTAL INPUT POWER W 63 64 79 POWER SOURCE V/Ph/Hz 220-240 / 1 / 50

NOMINAL RUNNING CURRENT A 0.28 0.28 0.35 REFRIGERANT TYPE N/A

V/Ph/Hz 220-240 / 1 / 50 AIR DISCHARGE 4 WAY AUTOMATIC LOUVER (UP & DOWN)
POWER SOURCE CONTROL
N/A OPERATION LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL
REFRIGERANT TYPE
AIR DISCHARGE 4 WAY AUTOMATIC LOUVER (UP & DOWN) HIGH CFM 750 860 890 1000 1140
CONTROL MEDIUM CFM 620 700 720 840 1000
OPERATION LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL AIR FLOW
LOW CFM 480 540 570 680 840
HIGH CFM 380 400 440
QUIET CFM 320 380 420 540 700
AIR FLOW MEDIUM CFM 290 310 330
USGPM 4.71 5.59 6.69 8.45 9.60
LOW CFM 230 220 280 NOMINAL WATER FLOW RATE
litres/min 17.83 21.17 25.29 31.94 36.29
USGPM 2.03 3.43 3.57
NOMINAL WATER FLOW RATE HEAD LOSS (COOLING) kPa 20 37 22 44 53

INDOOR UNIT
litres/min 7.68 12.98 13.51
HEAD LOSS (HEATING) : 50°C kPa 19 33 19 38 47
HEAD LOSS (COOLING) kPa 19.3 26.9 28.8
INDOOR UNIT

MAX. WORKING PRESSURE kPa 1600


HEAD LOSS (HEATING) : 50°C kPa 16.8 23.9 26.5
SURFACE AIR VELOCITY m/s 0.91 1.04 1.14 1.03 1.17
MAX. WORKING PRESSURE kPa 1608
SOUND PRESSURE LEVEL (H/M/L/Q) dBA 42/38/32/23 46/42/35/27 48/43/38/30 50/47/43/33 52/49/45/39
SURFACE AIR VELOCITY m/s 0.75 0.76 0.83
UNIT DIMENSION - ( ) WITH PANEL HXWXD mm 265 X 820 X 820 (340 X 990 X 990) 300 X 820 X 820 (375 X 990 X 990)
SOUND PRESSURE LEVEL (H/M/L) dBA 42 / 35 / 29 45 / 38 / 30 48 / 40 / 36
PACKING DIMENSION - ( ) PANEL HXWXD mm 341 X 916 X 916 (125 X 1020 X 1020) 376 X 916 X 916 (125 X 1020 X 1020)
UNIT DIMENSION - ( ) WITH PANEL HXWXD mm 250 X 570 X 570 (295 X 640 X 640)
UNIT WEIGHT (UNIT + PANEL) kg 26 + 4 26 + 4 28 + 4 32 + 4 32 + 4
PACKING DIMENSION - ( ) PANEL HXWXD mm 316 X 630 X 630 (126 X 700 X 726)
CONDENSATE DRAIN SIZE mm 19.05
UNIT WEIGHT (UNIT + PANEL) kg 15 + 3 17 + 3 17 + 3
PIPE CONNECTION mm 19.05 BSP FEMALE THREAD ADAPTOR
CONDENSATE DRAIN SIZE mm 19.05
PIPE CONNECTION mm 19.05 BSP FEMALE THREAD ADAPTOR NOTE :
A) BASED ON EUROVENT CONDITIONS
MODE COOLING HEATING B) ADDITIONAL 10W IS REQUIRED FOR CONDENSATE DRAIN PUMP
C) SOUND PRESSURE LEVEL IS TESTED AS PER JIS STANDARD AS BELOW :
ENTERING AIR TEMPRATURE 27°c DB / 19°c WB 20°c DB FWKE05E MODEL - 1.4M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT
ENTERING WATER 50°c (2 PIPES SYSTEM) FWKE08/11E MODEL - 1.5M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT
7°c
TEMPRATURE 70°c (4 PIPES SYSTEM) MODE COOLING HEATING
LEAVING WATER ENTERING AIR TEMPRATURE 27°c DB / 19°c WB 20°c DB
12°c
TEMPRATURE 60°c (4 PIPES SYSTEM) 50°c (2 PIPES SYSTEM)
ENTERING WATER
7°c
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE TEMPRATURE 70°c (4 PIPES SYSTEM)
LEAVING WATER
12°c
TEMPRATURE 60°c (4 PIPES SYSTEM)
Ceiling Casse e ype (900x900) With Brushless DC Motor
*
AL

pecification for Ceiling Casse e ype (4 Pipe System)


FWKE05EH FWKE08EH FWKE11EH
MODEL
QUIET LOW MEDIUM HIGH QUIET LOW MEDIUM HIGH QUIET LOW MEDIUM HIGH
Btu/h 6800 9600 12300 15000 13300 17100 20800 24600 17700 22200 26400 30700
NOMINAL COOLING CAPACITY
W 2000 2800 3600 4400 3900 5000 6100 7200 5200 6500 7750 9000
Btu/h 5300 7600 10200 13100 9900 13000 16600 19600 13300 16700 20700 24500
NOMINAL SENSIBLE COOLING CAPACITY
W 1560 2240 2990 3850 2910 3810 4850 5750 3890 4900 6060 7170
NOMINAL HEATING CAPACITY Btu/h 12800 17200 21700 26100 21800 27300 32800 38200 31900 39100 46200 53400
(ENTERIN WATER TEMP. 0 C) W 3750 5050 6350 7650 6400 8000 9600 11200 9350 11450 13550 15650
FWKE-E Wireless Remote Controller Wired Remote Controller FAN INPUT POWER W 7 12 19 37 17 26 50 90 23 39 83 120
BRC52A C A ption
NOMINAL RUNNING CURRENT A 0.11 0.13 0.19 0.26 0.19 0.28 0.43 0.74 0.21 0.35 0.55 0.95
POWER SOURCE V/Ph/Hz 220-240 / 1 / 50
REFRIGERANT TYPE N/A
AIR DISCHARGE WA AUTOMATIC LOU ER (UP & DOWN)
› Comfortable › Multi Comfort 3 Air Swing Pa ern Control › Auto Restart With Last-State-Memory CONTROL
OPERATION LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL
› Energy Saving › Fresh Air Intake › NIM-Able
› Low Noise › Built In High Head Drain Oump & Water Flow Switch › Choice Of Wired Or Withless Remote Controller AIR FLOW CFM 220 350 470 620 420 560 720 890 510 680 870 1060
› Low Maintenance & No Brush Sparking › alve Or alveless Control Options › Self Diagnosis Features E TERNAL STATIC PRESSURE (H/M/L) Pa N/A
› Modulating Fan Speed Control › 4 Selectable Fan Speed › Microprocessor Control
USGPM 1.53 2.14 2.76 3.37 2.99 3.83 4.67 5.51 3.98 4.98 5.93 6.89
› Modern & Elegant Panel › Branch Duct Connection › Pipe System Model FW E EH NOMINAL WATER FLOW RATE (COOLIN )
› Optimum Air Discharge › Low Height Design Litres/min 5.80 8.12 10.44 12.75 11.31 14.49 17.68 20.87 15.07 18.84 22.47 26.09
› Automatic Air Swing › Superior Stound Level USGPM 1.44 1.93 2.43 2.93 2.45 3.06 3.68 4.29 3.58 4.38 5.19 5.99
› 4 Way Air Discharge & Air Swing › Sleep Function For Cool & Heat Mode NOMINAL WATER FLOW RATE (HEATIN )
Litres/min 5.44 9.20 9.20 11.09 9.28 13.91 13.91 16.23 13.55 16.60 19.64 22.68
HEAD LOSS (COOLIN ) kPa 5 9 13 18 6 10 15 19 12 19 24 32
HEAD LOSS (HEATIN ) 0C kPa 7 10 17 22 13 18 25 32 21 30 39 52
MAX. WORKING PRESSURE kPa 1608
pecification for Ceiling Casse e ype
SURFACE AIR VELOCITY m/s 0.27 0.42 0.60 0.64 0.43 0.55 0.68 0.81 0.45 0.57 0.71 0.83
FWKE05E FWKE08E FWKE11E SOUND PRESSURE LEVEL dBA 16 23 31 37 31 37 42 47 34 41 46 51
MODEL
QUIET LOW MEDIUM HIGH QUIET LOW MEDIUM HIGH QUIET LOW MEDIUM HIGH UNIT DIMENSION ( ) WITH PANEL HXWXD mm 5 8 0 8 0 (3 0 990 990) 300 8 0 8 0 (3 5 990 990)
Btu/h 8200 11900 15900 20100 15200 19800 24700 30000 21000 26800 33100 40100 PACKING DIMENSION ( ) PANEL HXWXD mm 3 1 91 91 (1 5 10 0 10 0) 3 91 91 (1 5 10 0 10 0)
NOMINAL COOLING CAPACITY
W 2400 3500 4650 5900 4550 5800 7250 8800 6150 7850 9700 11750 UNIT WEIGHT kg 26 + 4 28 + 4 32 + 4
Btu/h 5800 8700 11700 15400 11000 14500 18500 21900 14600 18900 23800 28600 CONDENSATE DRAIN SIZE mm 19.05
NOMINAL SENSIBLE COOLING CAPACITY
W 1710 2540 3440 4510 3220 4260 5410 6430 4270 5540 6970 8370 PIPE CONNECTION mm 19.05 BSP FEMALE THREAD ADAPTOR
NOMINAL HEATING CAPACITY Btu/h 11300 15200 19800 24200 18400 23900 30400 38200 24100 31600 39100 46700
NOTE
(ENTERIN WATER TEMP. 50 C) W 3300 4450 5800 7100 5400 7000 8900 11200 7050 9250 11450 13700 A) BASED ON EURO ENT CONDITIONS
B) ADDITIONAL 10W IS REQUIRED FOR CONDENSATE DRAIN PUMP
FAN INPUT POWER W 7 12 19 37 17 26 50 90 23 39 83 120 C) SOUND PRESSURE LE EL IS TESTED AS PER IS STANDARD AS BELOW
FWKE05EH MODEL - 1.4M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT
NOMINAL RUNNING CURRENT A 0.11 0.13 0.19 0.26 0.19 0.28 0.43 0.74 0.21 0.35 0.55 0.95 FWKE08/11EH MODEH - 1.5M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT
POWER SOURCE V/Ph/Hz 220-240 / 1 / 50 MODE COOLING HEATING

REFRIGERANT TYPE N/A ENTERING AIR TEMPRATURE 27°c DB / 19°c WB 20°c DB

ENTERING WATER 50 c ( PIPES S STEM)


AIR DISCHARGE WA AUTOMATIC LOU ER (UP & DOWN) TEMPRATURE
7°c
CONTROL 0 c ( PIPES S STEM)
OPERATION LCD WIRELESS MICRO-COMPUTER REMOTE CONTROL LEAVING WATER
12°c
TEMPRATURE 0 c ( PIPES S STEM)
AIR FLOW CFM 220 350 470 620 420 560 720 890 510 680 870 1060
E TERNAL STATIC PRESSURE (H/M/L) Pa N/A
USGPM 1.84 2.68 3.56 4.52 3.41 4.44 5.55 6.74 4.71 6.01 7.43 9.00
NOMINAL WATER FLOW RATE
Litres/min 6.96 10.15 13.48 17.10 12.90 16.81 21.02 25.51 17.83 22.76 28.12 34.06
HEAD LOSS (COOLIN ) kPa 5 10 15 24 7 9 14 20 15 22 30 41
HEAD LOSS (HEATIN ) 50 C kPa 4 8 13 21 5 8 12 18 12 20 26 37
MAX. WORKING PRESSURE kPa 1608
SURFACE AIR VELOCITY m/s 0.27 0.42 0.60 0.64 0.43 0.55 0.68 0.81 0.45 0.57 0.71 0.83
SOUND PRESSURE LEVEL dBA 16 23 31 37 31 37 42 47 34 41 46 51
UNIT DIMENSION ( ) WITH PANEL HXWXD mm 5 8 0 8 0 (3 0 990 990) 300 8 0 8 0 (3 5 990 990)
PAC IN DIMENSION ( ) PANEL HXWXD mm 3 1 91 91 (1 5 10 0 10 0) 3 91 91 (1 5 10 0 10 0)
UNIT WEIGHT kg 26 + 4 28 + 4 32 + 4
CONDENSATE DRAIN SIZE mm 19.05

PIPE CONNECTION mm 19.05 BSP FEMALE THREAD ADAPTOR

17 18
Ceiling Con ertible ype Ceiling Con ertible ype
* *
AL AL

Wireless Remote Controller Wired Remote Controller Wireless Remote Controller Wired Remote Controller
FWE-D
FWE-E BRC52A BRC51A BRC52A BRC51A

› Compact Design › Saranet Filter › Two Way Air Discharge › Auto Restart With Last-State-Memory
› Far Air Throw › Sleep Function For Cool And Heat Mode › Auto Air Swing › alve Or alveless Control Options
› Auto Air Swing › Auto Restart With Last-State-Memory › Ceiling & Floor Installing Option › Self Diagnosis Features
› Service & Maintenance At Ease › alve Or alveless Control Options › Room Temperature Sensing › NIM-Able
› Ceiling & Floor Installing Option › Self Diagnosis Features › Saranet Filter › Choices Of Wired Or Wireless Remote Controller
› ersatile Installation › NIM-Able › Sleep Function For Cool And Heat Mode
› Room Temperature Sensing › Choices Of Wired Or Wireless Remote Controller
› 3 Selectable Fan Speed › Microprocessor Control

pecification for Ceiling Con ertible ype pecification for Ceiling Con ertible ype
MODEL FWE05E FWE06E FWE07E MODEL FWE07D FWE09D FWE13D
Btu/h 15500 20300 21000 Btu/h 24600 31200 45000
NOMINAL COOLING CAPACITY NOMINAL COOLING CAPACITY
W 4540 5950 6150 W 7210 9140 13190
Btu/h 12700 15400 16150 Btu/h 17700 25600 31400
NOMINAL SENSIBLE COOLING CAPACITY NOMINAL SENSIBLE COOLING CAPACITY
W 3720 4510 4730 W 5190 7500 9200
NOMINAL HEATIN CAPACIT Btu/h 19500 25000 28000 NOMINAL HEATIN CAPACIT Btu/h 28000 42300 51500
(ENTERING WATER TEMP. = 50 C) W 5720 7330 8210 (ENTERING WATER TEMP. = 50 C) W 8210 12400 15090
NOMINAL TOTAL INPUT POWER W 86 135 160 NOMINAL TOTAL INPUT POWER W 132 240 240
NOMINAL RUNNING CURRENT A 0.38 0.67 0.79 NOMINAL RUNNING CURRENT A 0.57 0.98 1.03
POWER SOURCE /Ph/Hz 220-240 / 1 / 50 POWER SOURCE /Ph/Hz 220-240/ 1 /50
REFRIGERANT TYPE N/A REFRIGERANT TYPE N/A
AIR DISCHAR E AUTOMATIC LOUVER (UP & DOWN) AIR DISCHAR E AUTOMATIC LOUVER (UP & DOWN)
CONTROL CONTROL
LCD WIRELESS MICRO-COMPUTER LCD WIRELESS MICRO-COMPUTER
OPERATION OPERATION
REMOTE CONTROL REMOTE CONTROL
HI H CFM 520 580 640 HI H CFM 697 956 1059
AIR FLOW MEDIUM CFM 460 530 560 AIR FLOW MEDIUM CFM 687 908 1023
LOW CFM 406 490 460 LOW CFM 650 889 956
USGPM 3.43 4.49 4.67 USGPM 5.46 6.91 9.99
NOMINAL WATER FLOW RATE NOMINAL WATER FLOW RATE
Litres/min 13 17 17.68 Litres/min 20.67 26.16 37.82
HEAD LOSS (COOLIN ) kPa 27 48 57 HEAD LOSS (COOLIN ) kPa 49 24 38
HEAD LOSS (HEATIN ) 50 C kPa 24 42 50 HEAD LOSS (HEATIN ) 50 C kPa 43 22 32
MA . WOR IN PRESSURE kPa 1608 MA . WOR IN PRESSURE kPa 1608
SURFACE AIR VELOCITY m/s 0.87 1.01 1.08 SURFACE AIR VELOCITY m/s 1.37 1.22 1.35
SOUND PRESSURE LE EL (H/M/L) dBA 45 / 38 / 36 46 / 43 / 39 49 / 46 / 41 SOUND PRESSURE LE EL (H/M/L) dBA 51 / 50 / 48 54 / 53 / 52 54 / 53 / 52
UNIT DIMENSION H W D mm 1 1090 30 UNIT DIMENSION H W D mm 249 x 1214 x 670 249 x 1714 x 670
PAC IN DIMENSION H W D mm 9 119 0 PAC IN DIMENSION H W D mm 354 x 1376 x 766 354 x 1876 x 766
UNIT WEI HT kg 27 UNIT WEI HT kg 45 70 70
CONDENSATE DRAIN SIZE mm 19.05 CONDENSATE DRAIN SIZE mm 19.05
PIPE CONNECTION mm 1 . BSP FEMALE THREAD ADAPTOR PIPE CONNECTION mm 19.05 BSP FEMALE THREAD ADAPTOR

MODE COOLING HEATIN MODE COOLING HEATIN


ENTERING AIR TEMPRATURE 27°c DB / 19°c WB 20°c DB ENTERING AIR TEMPRATURE 27°c DB / 19°c WB 20°c DB

ENTERING WATER 50°c (2 PIPES SYSTEM) ENTERING WATER 50°c (2 PIPES SYSTEM)
7°c 7°c
TEMPRATURE 70°c (4 PIPES SYSTEM) TEMPRATURE 70°c (4 PIPES SYSTEM)
LEAVING WATER LEAVING WATER
12°c 12°c
TEMPRATURE 60°c (4 PIPES SYSTEM) TEMPRATURE 60°c (4 PIPES SYSTEM)
ALL SPECIFICATIONS ARE SUB ECTED TO CHAN E B THE MANUFACTURER WITHOUT PRIOR NOTICE ALL SPECIFICATIONS ARE SUB ECTED TO CHAN E B THE MANUFACTURER WITHOUT PRIOR NOTICE

19 20
Ceiling Concealed Type
*
AL
pecification for Ceiling Concealed ype
MODEL FWC09C FWC11C FWC1 C FWC1 C FWC1 C
Btu/h 800 38000 3 000 00 51800
NOMINAL COOLIN CAPACIT
W 0 111 0 108 0 13100 15180
Btu/h 19 00 9800 9300 35100 0900
NOMINAL SENSIBLE COOLIN CAPACIT
W 5 0 8 30 8590 10 90 11990

NOMINAL HEATIN CAPACIT Btu/h 3 800 9 00 8000 5 900 5300


(ENTERIN WATER TEMP. 50 C) W 9 10 1 0 1 0 0 1 090 191 0
NOMINAL TOTAL INPUT POWER W 3 5 50 442 531
NOMINAL RUNNIN CURRENT A 1.50 . 8 1.93 1.8 .3
POWER SOURCE /Ph/Hz 0 0 / 1 / 50
REFRI ERANT T PE N/A
FWC-C ired emote Controller AIR DISCHAR E DUCTED
C A CONTROL
OPERATION WIRED MICRO COMPUTER REMOTE CONTROL
HI H CFM 830 1 50 1 0 13 0 1550
AIR FLOW MEDIUM CFM 0 1130 1100 1 0 1 00
› Excellent Air Distribution › Choices Of With Or Without Wired Handset
› Compaot Design › Useable Fan Speed LOW CFM 10 10 0 10 0 1190 1300
› High Capacity Range › Self Diagnosis Features E TERNAL STATIC PRESSURE Pa 1 / 1 8 / 88 118 / 108 / 88 1 8 / 88 / 39 15 / 13 / 108 15 / 13 / 98
› High External Static Pressure Range › NIM-Able US PM 5.55 8.59 8. 8 10.0 11.
› Double Protection Drainage › Auto Restart With Last State Memory NOMINAL WATER FLOW RATE
litres/min 1.01 3 .51 31.3 38.00 3.98

INDOOR UNIT
› Easy To Service › alve Or alveless Control Option
› Left/Right Piping Option › Speed Fan Motor For Application Flexibility HEAD LOSS (COOLIN ) kPa 1 .0 39.0 3.0 38.0 51.0
› Wide Capacity Range HEAD LOSS (HEATIN ) 50 C kPa 11.0 3 .0 19.0 33.0 8.0
MA . WOR IN PRESSURE kPa 1 08
SURFACE AIR ELOCIT m/s 1. 0 1. 1.83 1.5 1.5
pecification for Ceiling Concealed ype
SOUND PRESSURE LE EL (H/M/L) dBA / / 38 51 / 8 / 5 9/ 5/ 1 5 / 50 / 53 / 50 /
UNIT DIMENSION HXWXD mm 38 x 91 x 31 x 1 5 x 559 38 x 1003 x 38 x 1 8 x 38 x 1 8 x
MODEL FWC03C FWC0 C FWC0 C FWC0 C
PAC IN DIMENSION HXWXD mm 415 x 11 x 31 355 x 1 1x 15 x 1 5 x 31 15 x 1 9 x 31 15 x 1 01 x 31
Btu/h 9900 11 00 18000 500
NOMINAL COOLIN CAPACIT UNIT WEI HT kg 42 44 50 5
W 900 3 00 5 80 590
CONDENSATE DRAIN SI E mm 19.05
Btu/h 000 81 0 1 00 15 50
NOMINAL SENSIBLE COOLIN CAPACIT PIPE CONNECTION mm 19.05 BSP FEMALE THREAD ADAPTOR
W 050 380 3 90 0
NOMINAL HEATIN CAPACIT Btu/h 11500 15000 3000 9000 MODE COOLIN HEATIN
(ENTERIN WATER TEMP. 50 C) W 33 0 00 0 8500 ENTERIN AIR TEMPRATURE c DB / 19 c WB 0 c DB
50 c ( PIPES S STEM)
NOMINAL TOTAL INPUT POWER W 89 1 0 1 8 182 ENTERIN WATER
c
TEMPRATURE 0 c ( PIPES S STEM)
NOMINAL RUNNIN CURRENT A 0. 0 0. 5 0. 0.8
LEA IN WATER
0 0 / 1 / 50 1 c
POWER SOURCE /Ph/Hz TEMPRATURE 0 c ( PIPES S STEM)
REFRI ERANT T PE N/A ALL SPECIFICATIONS ARE SUB ECTED TO CHAN E B THE MANUFACTURER WITHOUT PRIOR NOTICE
AIR DISCHAR E DUCTED
CONTROL
OPERATION WIRED MICRO COMPUTER REMOTE CONTROL
HI H CFM 300 510 00 30
AIR FLOW MEDIUM CFM 285 90 5 0
LOW CFM 0 00 0 580
E TERNAL STATIC PRESSURE Pa 9/ /3 9/ / 8 9/ 5/ 1 9 / 3 / 30
US PM . 0 . 0 .05 5.0
NOMINAL WATER FLOW RATE
INDOOR UNIT

litres/min 8.33 9.8 15.33 19.15


HEAD LOSS (COOLIN ) kPa 10.5 .0 0.1 3 .
HEAD LOSS (HEATIN ) 50 C kPa 8.8 0.3 1 .0 .
MA . WOR IN PRESSURE kPa 1 08
SURFACE AIR ELOCIT m/s 1. 9 1. 1.83 1.
SOUND PRESSURE LE EL (H/M/L) dBA 3 / 35 / 33 0 / 38 / 33 / 1/ 0 1/ 0/3
UNIT DIMENSION HXWXD mm x 0 x 351 x8 x 351 x 100 x 351 x 113 x 351
PAC IN DIMENSION HXWXD mm 3 x 951 x 5 1 3 x 1091 x 5 1 3 x 1 51 x 5 1 3 x 138 x 5 1
UNIT WEI HT kg 18 22 24
CONDENSATE DRAIN SI E mm 19.05
PIPE CONNECTION mm 19.05 BSP FEMALE THREAD ADAPTOR

22
Ducted Blower Type
* *

AL

FUD20/25B FUD40/50B

› Excellent Air Distribution › Convertible Air Throw Direction


› 4 Useable Fan Speed › High CFM Range
› Easy To Service › Wide Capacity Range
› Fire Resistant Polysthylene Insulation › Useable Fan Speed Is Applicable For FUD 0/ 5B
› Left/Right Piping Option › Changeable Drive Package Is Applicable For FUD30/ 0B
› Cabinet Construction › Flexibility In Ad usting Air Flow And External Static For FUD30/ 0B
› High External Static Pressure Range › Convertible Air Throw Direction Is Applicable For FUD30/ 0B
› ChangeableDrive Package

pecification for ucted lower ype


MODEL FUD20B FUD25B FUD30B FUD40B
Btu/h 75600 95000 125000 150000
NOMINAL COOLING CAPACITY
W 22160 27840 36640 43960
Btu/h 53700 69400 90000 106500
NOMINAL SENSIBLE COOLING CAPACITY
W 15740 20340 26380 31210
NOMINAL HEATING CAPACITY Btu/h 78000 97500 138000 170000
(ENTERING WATER TEMP. = 50°C) W 22860 28580 40450 49820
NOMINAL TOTAL INPUT POWER W 760 1800 1620 1910
NOMINAL RUNNING CURRENT A 3.49 7.84 3.33 4.03
POWER SOURCE V/Ph/Hz 220-240 / 1 / 50 380-415 / 3 / 50
REFRIGERANT TYPE N/A
AIR DISCHARGE DUCTED
CONTROL
OPERATION WITHOUT CONTROLLER
HIGH CFM 2500 3200 4200 4600
AIR FLOW MEDIUM CFM 2100 3000 N/A N/A
LOW CFM 1750 2800 N/A N/A
EXTERNAL STATIC PRESSURE Pa 100 / 72 / 50 100 / 80 / 60 230 230
USGPM 16.90 21.10 27.70 33.30
NOMINAL WATER FLOW RATE
litres/min 64.00 80.00 105.00 126.00
INDOOR UNIT

HEAD LOSS (COOLING) kPa 34.5 42.0 48.8 53.3


HEAD LOSS (HEATING) : 50°C kPa 32.9 27.4 31.5 63.2
MAX. WORKING PRESSURE kPa 1608
SURFACE AIR VELOCITY m/s 2.19 2.80 1.96 2.15
SOUND PRESSURE LEVEL dBA 50/46/42 54/52/50 58 58
UNIT DIMENSION HXWXD mm 572 x 1402 x 605 885 x 1540 x 850
PACKING DIMENSION HXWXD mm 762 x 1605 x 880 1154 x 1787 x 1188
UNIT WEIGHT kg 92 102 176 189
CONDENSATE DRAIN SIZE mm 19.05
PIPE CONNECTION mm 31.75 BSP FEMALE THREAD ADAPTOR

MODE COOLING HEATING


ENTERING AIR TEMPRATURE 27°c DB / 19°c WB 20°c DB

ENTERING WATER 50°c (2 PIPES SYSTEM)


7°c
TEMPRATURE 70°c (4 PIPES SYSTEM)
LEAVING WATER
12°c
TEMPRATURE 60°c (4 PIPES SYSTEM)
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE

23
Controller
BRC52A
BRC52A61 – Heatpump with auto mode
BRC52A62 – Cooling only
BRC52A63 - Heatpump
7 1. ertical Automatic Air Swing
. Selectable Mode
Auto Mode, Cooling , Heating, Dry, Fan
3. Turbo Function
. Quiet Function
8
5. ON Timer Se ng
1 9
2 . Real Time Clock
3 . Transmission Source
10
4 8. low in the dark ON/OFF Bu on
11
9. Fan Speed Selection Low, Med, High, Auto
5 12
10. Temperature Se ng Up & Down
6 11. Sleep Mode Function
1 . OFF Timer Se ng

BRC51A
BRC51A61 – Heatpump with auto mode
BRC51A62 – Cooling only
Features:
Cool/Heat/Fan/Dry/Auto mode
Auto/High/Med/Low fan speed
Temperature operate in C and F
Turbo and Quiet Function
Sleep function
Swing function
Real time clock and day display
days programmable timer
Error indicator
ey lock and fan lock features
Ba eries backup and retain se ng during power failure
Last state memory (Memory backup se ng from main board)
Delay Timer (1 or hours)
Interaction with Wireless Handset (BRC5 A 1/BRC5 A )

24
Standard Features
COMFORT FIN TYPE
Turbo Mode Rapid cooling/heating with
highest fan speed for immediate comfort AL Bare Aluminium Fin

Quiet Mode Effective cooling with


lower noise level OLD Anti Corrosion Hydrophilic old Fin

Dry Mode eeping the room dehumidified, he outdoor models in the catalog comes with bare blue fin
while maintaining room temperature condenser. or gold fin outdoor models, specification remains
the same with the below model name change : eg :
Auto Mode Auto switching between cooling
and heating mode depending on room and set RYN25CXV1 to RYN25CGXV1 comes a er the series name
temperature of the outdoor.

Sleep Mode

AIR FLOW CONTROLLER


Selectable Fan Speed - Different fan speed is
available for comfort selection With Wireless Remote Controller

Belt Driven Evaporator Motor With Wired Remote Controller

ariable Pitch Pully Drive Package

Automatic ertical Swing Automatic movement


of air discharge louver for uniform air distribution

Manual Horizontal Air Flow - Adjustable horizontal


discharge grille for desired air flow direction

Way Air Discharge

IAQ POWER SUPPLY


Washable Saranet Filter - Removal of airborne dust
particles through saranet filter ensures cleaner Power from Indoor
air supply

Titanium Apatite Photocatalytic Air Purifying Filter Power from Outdoor

Bio Antibody Filter

Ionizer

25
upported Configuration
Intelligent Control Series BRC51A
Master Slave

BRC52A
Network Interface Module (NIM) is a networking system which enables communication among Daikin air conditioners.
With the Network Interface Module (NIM), all your air conditioning systems can be controlled with ust a single controller giving
you benefits Communication us Connection Recommended Maximum Cable Length (m)
Network Control NIM A way twisted pair cable is used as the First NIM to the furthest
1000
communication bus. Recommended cable for connected NIM
communication bus is a pair of screened & NIM to Main Board 10
enefits shielded, twisted single core wire with core
More convenience. No more individually controlling air conditioning units NIM to Wired Controller
Quicker and easier zone control from the master control unit
diameter of 0.5mm to 1.0mm. 10
Be er control of air conditioning systems operating conditions
Connection
NIM utilizes master slave type system whereby the master node will issue commands
to each of the slave nodes.
The communication bus must be connected serially to the ad acent NIM. (Daisy chain connection). The same
polarity has to be connected between the NIMs (A to A, B to B).
Every master unit will have a group address so that every slave can only response to
their respective master. Each slave unit must have a unique address so that it can be
addressed independently of other nodes.
G-Way
The master unit will be operating in con unction with a control panel. Any se ngs
done via the control panel connected to the master will overwrite the se ngs of its
slave units. unction
Slave unit can be operated with or without control panel. If a slave unit is operating ateway between fan coil unit and basic Building
with a control panel, its se ngs can be changed without following its master. NIM Management System (BMS).

Basic Features Note:


DIP switch se ng for roup & Unit address. Maximum point to point communication bus up to 1000m. Remote (On/Off) control of air conditioner via BMS.
Master or slave system configuration. A single master unit can control up to 15 slave units in each group. Unit error indication via BMS and BRC51A controller.
Automatic detection of control panel existence. Each slave unit will sense their individual local temperature. Unit operation status monitoring via BMS.
Error type and unit ID indication through display control panel. Unit address range from 0 to 15 (0000 1111).
Maximum point to point communication bus
between air conditioner and BMS of up to 1000m.
The NIM System Consists Of DIP switch se ng for control or monitoring function.
G-Way
Main Board controller Display control panel NIM controller Communications bus

ypes of peration e ng
Connection
Control & Monitor (Ext. Switch Closed = ON A/C) 0000
Control & Monitor (Ext. Switch Open = ON A/C) 0010
Monitoring only 0001
e ng
(up to total of
16 FCUs)
To Wired Control Panel

Dry Contact Dry Contact


CN2 Switch
Input

NO Dry Contact nit n ff


Master Slave Slave(s) Slave(s) To MainBoard CN1 RELAY 1 Indicator
COM Output 1
RELAY 2
NO Dry Contact Unit Error
COM Output 2 Indicator
Main Board Controllers And Display Control Panel DIP Switch
NIM must be used in con unction with Terminal
Blocks
Fan coil units
BRC51A or BRC5 A 1000 m
G-Way Controller BMS
26 27
S-NIM For Timer Switchover Control

Built on the NIM configuration, S NIM serves to enhance the


abilities and extend the operating lifetime of existing air
conditioning units in harsh and demanding environment.

S NIM works in a master & slave system, operating at alternate


sequence of preset hours. Whenever the operating unit is at
fault, the standby unit will automatically takes over.

S-NIM

eatures
Auto restart feature with last state se ngs.
air conditioning units in a master & slave system, operating at alternate sequence of preset time (3/ /5/ /9/11/1 hours).
System controlled by a single BRC51A controller.
When the operating unit is at fault, the standby unit automatically takes over.
Error indication via error code displayed on LCD panel. (only is using Netware 3 control panel)
During system OFF mode, running timer will stop. It resumes when changing to ON mode.
Preset operation hours can be set via DIP Switch.
The air conditioning unit connected to the wired controller is always the master unit.

he ystem Consists f
Main Board controller S NIM controller
BRC51A Communication Bus

Communication us
A way twisted pair cable is used as the communication bus.
Recommended cable for communication bus is a pair of screened & shielded, twisted single core wire with core diameter
of 0.5mm to 1.0mm.

Controller Application
Server Room Laboratory
Telecommunication Tower Railway Switching Center
Livestock Breeding Farm Room with Critical Electronics Equipments
Warehouse

Main Board Main Board

S-NIM S-NIM

Slave Unit

Control Panel
Master Unit
ypical connection structure for

28