This document provides instructions for using GC Fuji LINING LC, a light-cured glass ionomer lining cement. It lists the recommended indications as a base or liner in prepared cavities and contraindications as pulp capping or rare cases of sensitivity. Directions are given for powder and liquid dispensing using a 1.4/1 ratio, mixing for 20-25 seconds, and light curing for 30 seconds. The working time is 3 minutes and depth of cure is up to 1.6mm. Storage instructions and package contents are also specified.
This document provides instructions for using GC Fuji LINING LC, a light-cured glass ionomer lining cement. It lists the recommended indications as a base or liner in prepared cavities and contraindications as pulp capping or rare cases of sensitivity. Directions are given for powder and liquid dispensing using a 1.4/1 ratio, mixing for 20-25 seconds, and light curing for 30 seconds. The working time is 3 minutes and depth of cure is up to 1.6mm. Storage instructions and package contents are also specified.
This document provides instructions for using GC Fuji LINING LC, a light-cured glass ionomer lining cement. It lists the recommended indications as a base or liner in prepared cavities and contraindications as pulp capping or rare cases of sensitivity. Directions are given for powder and liquid dispensing using a 1.4/1 ratio, mixing for 20-25 seconds, and light curing for 30 seconds. The working time is 3 minutes and depth of cure is up to 1.6mm. Storage instructions and package contents are also specified.
For use only by a dental professional in the 3. RESTORATIVE TECHNIQUE
recommended indications. a) Prepare tooth using standard techniques. Extensive mechanical retention is not necessary. RECOMMENDED INDICATIONS b) Wash and dry but DO NOT DESICCATE. GC CAVITY As a base or liner in prepared cavities. CONDITIONER or GC DENTIN CONDITIONER is recommended to remove the smear layer. For CONTRAINDICATIONS pulp capping use calcium hydroxide. 1. Pulp capping. c) Mix the required amount of cement. Working time is 3 2. In rare cases the product may cause sensitivity to minutes from the start of mixing at 23°C (73.4°F). some persons. If such reactions are experienced, Higher temperatures will shorten working time. discontinue the use of the product and refer to a d) Remove surface moisture, but DO NOT DESICCATE. physician. e) Transfer cement to the preparation using a syringe or suitable placement instrument, covering dentine up to the dentino-enamel junction. DIRECTIONS FOR USE f) Light cure with a suitable visible light curing device (470nm wavelength) for 30 seconds. Place light Powder / Liquid Ratio (g/g) 1.4 / 1.0 source as closely as possible to the cement surface. Note : Mixing Time (sec.) 20-25" If application exceeds 1.6 mm in depth, use a layering Working Time (min., sec.) 3'00" technique. g) Proceed with standard composite or amalgam Light Curing Time (sec.) 30" restorative techniques. Depth of Cure (mm) 1.6 STORAGE Test conditions : Temperature (23 +/-1°C) Store in a cool and dark place (4-25°C) (39.2-77.0°F). Relative humidity (50 +/-10%) (Shelf life : powder 3 years, liquid 2 years) ISO 9917-2 : 1998 (E) (Light-activated cements)(Type I) PACKAGES 1. POWDER AND LIQUID DISPENSING 1. Bottle of 10g powder with scoop. a) The standard powder to liquid ratio is 1.4/1.0g. 1 level 2. Bottle of 8g (6.8mL) liquid. scoop of powder to 1 drop of liquid. 3. 1-1 pkg. : 10g powder, 8g (6.8mL) liquid, powder b) For accurate dispensing of powder, lightly tap the scoop, plastic spatula, mixing pads. bottle against the hand. Do not shake or invert. c) Hold the liquid bottle vertically and squeeze gently. CAUTION d) Close bottles immediately after use. 1. In case of contact with oral tissue or skin, remove immediately with a sponge or cotton soaked in alcohol. 2. MIXING Flush with water. Dispense powder and liquid onto the pad. Using the 2. In case of contact with eyes, flush immediately with plastic spatula, divide the powder into two equal parts. water and seek medical attention. Mix the first portion with all of liquid for 5-10 seconds. 3. DO NOT mix powder or liquid with any other glass Incorporate the remaining portion and mix the whole ionomer components. thoroughly for 10-15 seconds.