Download as pdf or txt
Download as pdf or txt
You are on page 1of 162

class EUtranCellFDD Page 1 of 162

    class  EUtranCellFDD    

class EUtranCellFDD
ManagedElement

+-ENodeBFunction

+-EUtranCellFDD

+-Cdma20001xRttBandRelation [0..32]
+-Cdma2000FreqBandRelation [0..32]
+-EUtranFreqRelation [0..8]
+-GeranFreqGroupRelation [0..16]
+-UeMeasControl [1..1]
+-UtranFreqRelation [0..16]

This MO represents a Cell and contains parameters needed by the cell. It also contains
parameters for the mandatory common channels.

Filter: FDD

Possible parents:
ENodeBFunction;
Possible children:
Cdma20001xRttBandRelation [0..32]; Cdma2000FreqBandRelation [0..32];
EUtranFreqRelation [0..8]; GeranFreqGroupRelation [0..16]; UeMeasControl [1..1];
UtranFreqRelation [0..16];
References to:
AirIfLoadProfile; ExternalCdma20001xRttCell; ManagedObject; QciTable; SectorCarrier;
SectorEquipmentFunction;

Actions
void changeFrequency ( long earfcn );
throws ChangeFrequencyException
Changes the frequency of the cell. The attribute earfcndl is changed. This MO action
includes the following steps:

- An instance of EUtranFrequency with correct frequency is created (if not already


existing).

- For neigbouring cells with existing cell relations to the cell, create new
EUtranFreqRelation instances (if not already existing) and new EUtranCellRelation
instances (with the same attribute values as the existing EUtranFreqRelation and
EUtranCellRelation MOs).

- For the changed cell an instance of EUtranFreqRelation with reference to the correct
instance of EUtranFrequency is created, if not already existing (with the same
attribute values as the existing EUtranFreqRelation MO).

Note that changing frequency of a EUtranCellFDD will imply that all other eNBs that
have this cell configured as an ExternaEUtranCellFDD will be updated with the new
frequency. This means that new EUtranFreqRelation and corresponding
EUtranFrequency MOs might be created.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 2 of 162

Transaction required: Yes


Disturbances: Changes may affect traffic. The cell will be automatic locked/unlocked
if needed.

Parameters

Name: earfcn
Range: 0..17999
Description: The new DL frequency for this cell.

void startAilg ( );
throws AlreadyStartedException
throws DeviceDisabledException
throws InternalErrorException
throws MoAccessException
throws NoLicenseException
Starts the execution of the optional feature Air Interface Load Generation.

Transaction required: Yes


void stopAilg ( );
throws AlreadyStoppedException
Stops the execution of the optional feature Air Interface Load Generation.

Transaction required: Yes

Attributes
AcBarringConfig acBarringForCsfb
Access class barring parameters for mobile originating CSFB
calls.
The information is broadcasted in SIB2.

Takes effect: Immediately


boolean acBarringForCsfbPresent = false
Specifies presence of ac-BarringForCSFB in SIB2.

Takes effect: Immediately


boolean acBarringForEmergency = false
Access class barring for AC 10

Takes effect: Immediately


AcBarringConfig acBarringForMoData
Access class barring parameters for mobile originating calls.
The information in broadcasted in SIB2.

Takes effect: Immediately


boolean acBarringForMoDataPresent = false
Specifies presence of Information Element ac-BarringForMO-
Data in SIB2.

Takes effect: Immediately


AcBarringConfig acBarringForMoSignalling
Access class barring parameters for mobile originating
signalling.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 3 of 162

The information in broadcasted in SIB2.

Takes effect: Immediately


boolean acBarringForMoSignallingPresent = false
Specifies presence of Information Element ac-BarringForMO-
Signalling in SIB2.

Takes effect: Immediately


AcBarringInfo acBarringInfo
Contains all access barring information.

Deprecated:  Since L12B. Replaced by attributes on cell level.


See struct AcBarringInfo for details.

Takes effect: Immediately


boolean acBarringInfoPresent = false
Specifies presence of Information Element ac-BarringInfo in
SIB2.

Takes effect: Immediately


PlmnIdentity[0..6] activePlmnList
nonUnique
nonPersistent Lists the PLMN IDs served by at least one MME. The PLMN ID is
readOnly defined in the attribute eNodeBPlmnId in the parent
ENodeBFunction. PLMN IDs from additionalPlmnList also appear
in this list. The list may include up to 6 PLMNs.
PlmnIdentity[0..5] additionalPlmnList
nonUnique
Lists additional PLMN IDs supported in the cell.

The list may include up to 5 PLMNs, and they must be the same
in all EUtranCells in the node.

Takes effect: Immediately


boolean[0..5] nonUnique additionalPlmnReservedList =
false,false,false,false,false
For the list of PLMN IDs in the cell, indicates if they are reserved
for operator use. The list must have the same number of entries
as additonalPlmnList. The PLMN ID appearing in
additionalPlmnList[x] is reserved when
additionalPlmnListReserved[x] is set to true.

Dependencies: The length of this list must be the same as the


list in addtionalPlmnList.
Takes effect: Immediately
AdminState administrativeState = LOCKED
The administrative state.

Takes effect: Immediately


AdvCellSupActions advCellSupAction = NO_ACTION
Controls which recovery actions to be performed when ACS
detects a sleeping cell.

Takes effect: Immediately


long advCellSupSensitivity = 0 { 0..100 }
Indicates the sensitivity of the Advanced Cell Supervision
function. A higher value will make ACS detect a sleeping cell
faster, but with higher risk for false detection. A lower value will

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 4 of 162

make ACS detect a sleeping cell slower, but with lower risk for
false detection.

Takes effect: Immediately


boolean agpsSuplActive = false
Indicates if the feature A-GPS Support in SUPL Environment is
ACTIVATED or DEACTIVATED in the cell.

Deprecated: Since L11B. Planned to be removed.

Dependencies: None
Takes effect: Immediately
boolean ailgActive
nonPersistent
readOnly The state of the feature Air Interface Load Generator. Indicates
if it is running or stopped.
AirIfLoadProfile ailgRef
Refers to an instance of AirIfLoadProfile. Assigns a
AirIfLoadProfile to a cell.

Takes effect: Immediately


long altitude = 0 { -32768..32767 }
The altitude of the transmitter antenna in meters. Use +/-
values to denote height/depth.
In case of Combined Cell (multi-sector cell):
For indoor system, antenna of any sector.
For outdoor system,antenna of macro sector.

Unit: 1 meter
Takes effect: Immediately
AltDirVals altitudeDir = HEIGHT
The antenna altitude direction. Valid values are HEIGHT and
DEPTH.

Deprecated: Since L11B. Has no functional behavoiur.

Dependencies: None
Takes effect: Immediately
AvailabilityStatus availabilityStatus
nonPersistent
readOnly The availability status. It contains details about
operationalState. This attribute is set by the application in the
RBS.
Cdma2000SysTimeVals bcCdma2000SysTimeType
nonPersistent
readOnly The actual type of CDMA2000 system time that is broadcast in
SIB8.
PlmnIdentity[0..2] bPlmnList
nonUnique
The Public Land Mobile Network (PLMN) ID of the cell.

The PLMN ID consists of:

1. MobileCountryCode, MCC, 3 digits


2. MobileNetworkCode, MNC, 2 or 3 digits (the correct number
of digits is set in the mncLength member of this Struct)

Example: If MCC=125 and MNC=46, then plmnId=12546.

Deprecated: Since L11A. Replaced by:


ENodeBFunction::eNodeBPlmnId and additionalPlmnList

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 5 of 162

Disturbances: Changes may affect traffic


Takes effect: Immediately
CellBarred cellBarred = NOT_BARRED
Indicates if the cell is barred and should not be accessible to
random UEs.

Takes effect: Immediately


long cellId { 0..255 }
mandatory
noNotification RBS internal ID attribute for EUtranCell. Must be unique in the
restricted RBS. Together with the Node ID and Public Land Mobile Network
(PLMN) this is a universally unique cell ID.

Range 0-255.
long cellRange = 15 { 1..100 }
Defines the maximum distance from the base station where a
connection to a UE can be setup and/or maintained.

Unit: 1 km
Disturbances: Changes may affect traffic.
Takes effect: Object unlocked
CellReservedForOperatorUse cellReservedForOperatorUse = NOT_RESERVED
[0..2] nonUnique
Indicates if the cell is reserved for operator use.

The first index is for the primary Public Land Mobile Network
(PLMN) of the cell.

Deprecated: Since L11A. Replaced by: primaryPlmnReserved


and additionalPlmnReservedList

Takes effect: Immediately


long cellSubscriptionCapacity = 1000 { 0..1000000 }
Normalized subscription capacity of the cell. The value
represents the total capacity of the cell used for traffic load
balancing purposes.

Takes effect: Immediately


boolean cfraEnable = false
This parameter controls if Contention Free Random Access
(CFRA, known as non-contention based random access in 3GPP
term) shall be enabled or not. When enabled, a portion of
random access preambles should be allocated for CFRA and
CFRA can be used for incmoing HO and PDCCH ordered uplink
re-sync.

Takes effect: Cell lock/unlock


ChangeNotificationSIBs changeNotification
For each System Information Block (SIB), indicates when the
SIB content is changed, if system information change
notification is broadcast prior to broadcast of updated system
information.

Takes effect: Immediately


long commonSrPeriodicity = 10 { 5, 10, 20 }
Common SR periodicity, used for all UEs.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 6 of 162

Unit: 1 ms
Dependencies: For 1.4 MHz: Only valid inputs are 10 and 20.
Takes effect: Cell lock/unlock
long confidence = 100 { 0..100 }
Percentage of confidence that the target device is within the
ellipsoid defined by the three axes of uncertainty: semi-major,
semi-minor, and altitude.

Unit: 1 percent
Dependencies: None
Takes effect: Immediately
long configurableFrequencyStart = 0 { 0..100 }
The start frequency offset for allocating resources when the
downlink interference management is disabled. Expressed as a
percentage of the available bandwidth.

Unit: 1 Percentage
Deprecated: Replaced by dlConfigurableFrequencyStart. Since
L11B.

Takes effect: Immediately


boolean covTriggerdBlindHoAllowed = true
Says whether a blind Handover from this cell can be initiated
when a UE reports bad coverage, or not. Note that even if the
value is True, the eNB will only initate a blind handover if it finds
a suitable cell.

Takes effect: Immediately


long dlChannelBandwidth = 10000 { 1400, 3000, 5000, 10000,
15000, 20000 }
The downlink channel bandwidth in the cell.

Valid values: 1400, 3000, 5000, 10000, 15000, 20000

Unit: 1 kHz
Dependencies: This attribute is dependent on and shall be set to
the same as ulChannelBandwidth.
Disturbances: Changes may affect traffic.
Takes effect: Object disabled/enabled.
long dlConfigurableFrequencyStart = 0 { 0..100 }
Specifies the start frequency offset for the allocation of
resources when the downlink interference management is
disabled expressed as a percentage of the configured
bandwidth.

Unit: 1 percent
Dependencies: dlInterferenceManagementActive shall be
disabled before this parameter takes effect.
Takes effect: Object unlocked
long dlFrequencyAllocationProportion = 100 { 0..100 }
Specifies the amount of frequency resources that is allocated in
DL expressed as a percentage of the configured bandwidth.

Unit: 1 percent
Takes effect: Object unlocked
boolean dlInterferenceManagementActive = false
Specifies if the downlink interference management is enabled or
disabled.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 7 of 162

Takes effect: Object unlocked


boolean drxActive = false
Indicates if the DRX function in the cell is activated.

Takes effect: New connection


long earfcndl { 0..17999 }
mandatory
restricted The channel number for the central downlink frequency. The
mapping from channel number to physical frequency for
specified E-UTRA bands is described in 3GPP TS 36.104. The
values that can be used depend on national, operator-specific
frequency allocation as well as on the supported frequency band
(s) in the RBS.

Note: Use the MO-action changeFrequency if the DL frequency


shall be changed after the cell is initally setup. This attribute is
dependent on and set together with earfcnul, the values are
dependent and relate accoring to the form
earfcnul=earfcndl+18000.

Disturbances: Changes may affect traffic.


Takes effect: Object disabled/enabled.
long earfcnul { 18000..35999 }
mandatory
The channel number for the central uplink frequency. The
mapping from channel number to physical frequency for
specified E-UTRA bands is described in 3GPP TS 36.104. The
values that can be used depend on national, operator specific
frequency allocation as well as on the supported frequency band
(s) of the RBS.

Note: This attribute is dependent on and set together with


earfcndl, the values are dependent and relate accoring to the
form earfcnul=earfcndl+18000.

Disturbances: Changes may affect traffic.


Takes effect: Object disabled/enabled
long[0..4] nonUnique emergencyAreaId = -1,-1,-1,-1 { -1..16777215 }
A cell supporting broadcast of warning messages may belong to
one to four Emergency Areas. Such an area is identified by an
Emergency Area Id, set by the operator. Value -1 means
identity not set.

Takes effect: Immediately


EutranCellArea eutranCellCoverage
Models the cell coverage area used for UE positioning. The cell
coverage area is defined by the cell bearing, cell opening angle
and cell radius.

This attribute has no operational impact.

Takes effect: Immediately


string EUtranCellFDDId
mandatory
The value component of the RDN.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 8 of 162

noNotification
restricted
EutranCellCorner[0..15] eutranCellPolygon
nonUnique
Models the manageable characteristics for the cell polygon used
for UE positioning. Each polygon corner is described by a
latitude and longitude pair. Each polygon corner is represented
with one position in the sequence. The other configured polygon
corners follow in sequence. There must at least be three corners
configured in a polygon when the function is active/used. The
points shall be connected in the order that they are given. The
last point is connected to the first point.

Takes effect: Immediately


ExternalCdma20001xRttCell externalCdma20001xRttCellRef
noNotification
Reference to a ExternalCdma20001xRttCell
FrameStartOffset frameStartOffset
The frame start offset of the cell.

Disturbances: Changes may affect traffic.


Takes effect: Object disabled/enabled.
longlong gpsTimeSFN0DecimalSecond { 0..4294967295 }
readOnly
The decimal part of the GPS time for the most recent occurrence
of System Frame Number (SFN )=0 in the cell.

Unit: 2^(-32) second


Dependencies: None
longlong gpsTimeSFN0Seconds { 0..4294967295 }
readOnly
The integer part of the GPS time for the most recent occurrence
of SFN=0 in the cell.

Unit: 1 Seconds
Dependencies: None
boolean highSpeedUEActive = false
Indicates if the feature High Speed UE is activated in the cell

Takes effect: Object unlocked


ManagedObject hostingDigitalUnit
readOnly
Shows the DU on which baseband processing for the cell is
located
Cdma2000SysTimeVals initCdma2000SysTimeType = NONE
Intended type of CDMA2000 system time to broadcast in SIB8,
if applicable.

Takes effect: Immediately


LastModificationSourceCell lastModification = OPERATOR
Indicates whether the MO was last modified by the operator or if
the MO has been modified by the PCI conflict detection
application.

Takes effect: Immediately


long latitude = 0 { -90000000..90000000 }
The degree of latitude of the transmitter antenna position.
In case of Combined Cell (multi-sector cell):
For indoor system, antenna of any sector.
For outdoor system,antenna of macro sector.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 9 of 162

Unit: 10^(-6) degrees


Takes effect: Immediately
LatDirVals latitudeDir = NORTH
The latitude of the transmitter antenna position. Valid values are
NORTH and SOUTH.

Deprecated: Since L11B. Has no functional behaviour.

Dependencies: None
Takes effect: Immediately
long lbUtranOffloadThreshold = 100 { 0..1600 }
Threshold for eNodeB
The value applies for offload towards UTRAN target cells. The
eNodeB attempts to offload traffic from the source cell
corresponding to the subscription ratio above the threshold.

Unit: 0.01 .
Takes effect: Immediately
long longitude = 0 { -180000000..180000000 }
The degree of longitude of the transmitter antenna position.
In case of Combined Cell (multi-sector cell):
For indoor system, antenna of any sector.
For outdoor system,antenna of macro sector.

Unit: 10^(-6) degrees


Takes effect: Immediately
MappingInfoSIBs mappingInfo
The System Information (SI) message to which each System
Information Block (SIB) is mapped.

Note: SIB2 is always mapped to the SI message 1 according to


3GPP TS 36.331.

Takes effect: When EUtranCellFDD/TDD object is unlocked


long maximumTransmissionPower { -1..540 }
nonPersistent
readOnly Maximum possible power at the antenna reference point, for all
downlink channels in all TX branches used simultaneously in the
cell.

-1 is used as an undefined value.

Note: Setting partOfSectorPower or confOutputPower (MO


SectorEquipmentFunction) has an impact on this attribute. See
Radio Network Configuration user guide 11/1553-HSC 105 50/1.

Unit: 0.1 dBm


Deprecated: Since L13A. Planned to be removed. Replaced by
SectorCarrier::MaximumTransmissionPower. The value from the
first SectorCarrier in the
EUtranCellFDD/EUtranCellTDD::sectorCarrierRef will be mapped
to this deprecated attribute.

long maxNoConcurrSib12 = 3 { 1..32 }


Maximum number of concurrent System Information messages
carrying SIB12, i.e carrying Commercial Mobile Alert System
(CMAS) notifications.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 10 of 162

Deprecated: Since L12B. Planned to be removed.

Takes effect: Immediately


long minBestCellHoAttempts = 1 { 1..10 }
Number of attempts for handover to a cell better than the
serving cell, before handover is attempted to the next best cell.
If there is no next best cell in the UE report, handover to the
best cell is attempted repeatedly.

Takes effect: Immediately


boolean mobCtrlAtPoorCovActive = false
Specifies if the feature Mobility Control at Poor Coverage is
enabled or disabled in the cell.

Takes effect: New connection


long modificationPeriodCoeff = 2 { 2, 4, 8, 16 }
The modification period, expressed in number of radio frames =
modificationPeriodCoeff * defaultPagingCycle. See MO Paging
for information about defaultPagingCycle.

Dependencies: modificationPeriodCoeff * defaultPagingCycle


must be equal or less than 1024 radio frames. See MO Paging
for information about defaultPagingCycle.
Takes effect: When EUtranCellFDD/TDD object is unlocked
NetworkSignallingValue networkSignallingValue = NS_01
Enables additional spectrum emission requirements according to
3GPP TS 36.101, table 6.2.4-1.

Takes effect: Object disabled/enabled


NoOfSubframesVals noConsecutiveSubframes = SF4
The number of consecutive downlink sub-frames with
positioning reference signals as defined in 3GPP TS 36.211.
Values define 1, 2, 4, or 6 consecutive sub-frames.

Dependencies: None
Takes effect: Object unlocked
long noOfDefPagCyclPrim = 8 { 1..16 }
Number of consecutive "DefaultPagingCycles" in which paging
for Earthquake and Tsunami Warning System (ETWS) Primary
Notification shall be transmitted in the cell.

Deprecated: Since L12B. Replaced by


Paging::noOfDefPagCyclPrim

Takes effect: Immediately


long noOfPucchCqiUsers = 160 { 0..4000 }
The number of Channel Quality Indicator (CQI) resources
available on the PUCCH channel.
For 1.4 MHz system bandwidth the recommended value is 50.

Disturbances: Changes may affect traffic.


Takes effect: Object unlocked. Note: The parameter will take
effect when System Information is updated.
long noOfPucchSrUsers = 160 { 0..4000 }

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 11 of 162

The number of Scheduling Request (SR) resources available on


the PUCCH channel.
For 1.4 MHz system bandwidth the recommended value is 50.

Disturbances: Changes may affect traffic.


Takes effect: Object unlocked. Note: The parameter will take
effect when System Information is updated.
long noOfRxAntennas = 0 { 0, 1, 2, 4, 8 }
The number of antennas that can be used for uplink
beamforming/MIMO
A parameter value of 0 means that the available configured
resources will be used.

Deprecated: Since L13A. Planned to be removed. Replaced by


SectorCarrier::noOfRxAntennas. The value from the first
SectorCarrier in the
EUtranCellFDD/EUtranCellTDD::sectorCarrierRef will be mapped
to this deprecated attribute.

Dependencies: Dependent on optional features that enable


usage of multiple Rx antennas.
Disturbances: Changes may affect traffic.
Takes effect: Object disabled/enabled.
long noOfTxAntennas = 0 { 0, 1, 2, 4, 8 }
The number of antennas that can be used for downlink
beamforming/MIMO
A parameter value of 0 means that the available configured
resources will be used.

Deprecated: Since L13A. Planned to be removed. Replaced by


SectorCarrier::noOfTxAntennas. The value from the first
SectorCarrier in the
EUtranCellFDD/EUtranCellTDD::sectorCarrierRef will be mapped
to this deprecated attribute.

Dependencies: Dependent on optional features that enable


usage of multiple Tx antennas.
Disturbances: Changes may affect traffic.
Takes effect: Object disabled/enabled.
long nrOfSymbolsPdcch = 1 { 1..3 }
The number of Orthogonal Frequency-Division Multiplexing
(OFDM) symbols used for the Physical Downlink Control Channel
(PDCCH).

Unit: 1 OFDM Symbols


Deprecated: Since L12A. Planned to be removed.

Takes effect: Immediately


OperState operationalState
nonPersistent
readOnly The operational state. This attribute is set by the application in
the RBS.
long orientMajorAxis = 0 { 0..179 }
Orientation of the major axis of uncertainty, in degrees
clockwise from north. Orientation value (N) is derived by the
formula:

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 12 of 162

N <= X < (N + 1)

where X is the orientation in degrees (0° - 180°).

Unit: 1 degrees
Dependencies: None
Takes effect: Immediately
boolean otdoaSuplActive = false
Indicates if the feature OTDOA Support in SUPL Environment is
ACTIVATED or DEACTIVATED in the cell.

Takes effect: Object unlocked.


long partOfRadioPower = 100 { 0..100 }
The requested part of the total radio power in the Sector that
should be allocated for the cell. The output power is evenly
distributed over the antenna connectors used for TX
transmission that are allocated for the cell.

If the total amount of power per antenna connector is over


100% when the cell is unlocked, an alarm will be generated.

Unit: 1 %
Deprecated: Replaced by partOfSectorPower. Since L11B.

Disturbances: Changes may affect traffic.


Takes effect: Object disabled/enabled.
long partOfSectorPower = 100 { 0..100 }
The requested part of the total power in the Sector that should
be allocated for the cell. The output power is evenly distributed
over the antenna connectors used for TX transmission that are
allocated for the cell.

If the total amount of power per antenna connector is over


100% when the cell is unlocked, an alarm will be generated.

Unit: 1 %
Deprecated: Since L13A. Planned to be removed. Replaced by
SectorCarrier::partOfSectorPower. The value from the first
SectorCarrier in the
EUtranCellFDD/EUtranCellTDD::sectorCarrierRef will be mapped
to this deprecated attribute.

Disturbances: Changes will affect traffic.


Takes effect: Object disabled/enabled.
PciConflict[0..5] pciConflict = NO,NO,NO,NO,NO
nonUnique
A PCI confusion exists if a source cell has relations to two
neighbours cells where both neighbours cells have the same PCI
and frequency. A PCI collision exists if a source cell has a
relation to a neighbour cell where both the source cell and
neighbour cell has the same PCI and frequency.
Cgi[0..5] nonUnique pciConflictCell
Indicates the CGI of the other cell that is involved in the PCI
collision/confusion. This value is only valid if the attribute
pciConflict is "YES" or "YES_CONFLICTING_CELL".

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 13 of 162

Takes effect: Immediately


Cgi[0..5] nonUnique pciDetectingCell
Indicates the CGI of the cell that detected the PCI
collision/confusion. This value is only valid if the corresponding
attribute pciConflict is "YES" or "YES_CONFLICTING_CELL". The
first cell in the pciDetectingCell list corresponds to the first cell
in the pciConflictCell list and the first value of pciConflict. The
second cell in the pciDetectingCell list corresponds to the second
cell in the pciConflictCell list and the first value of pciConflict.

Takes effect: Immediately


boolean pdcchAdmEnabled = false
Enable the pdcch admission control feature. All rejects will be
logged in counter pmCellAdmControlPdcchRej. If set to false we
will not reject any Ues due to this function but the potential
rejects will be lkogged in counter
pmCellAdmControlPdcchRejMeas.

Takes effect: Cell lock/unlock


long pdcchAdmThreshold = 1000 { 0..1000 }
Sets the threshold for the CCE usage when ue starts to be
rejected. This will only cause real rejects if pdcchAdmEnabled =
true. Otherwise we will only step
pmCellAdmControlPdcchRejMeas both no rejects will take place.

Unit: 0.001 .
Takes effect: Cell lock/unlock
CfiMode pdcchCfiMode = CFI_STATIC_BY_BW
Controls the CFI (Control Format Indicator) used for the control
region. cfiMode maps to CFI as described under enumerations.
For DL BW of 1400 kHz, values of CFI = 1, 2 and 3 map to 2, 3,
and 4 control region symbols respectively. Other BW, CFI maps
directly to number of control region symbols.

Dependencies: pdcchCfiMode cannot equal CFI_STATIC_1 while


dlChannelBandwidth = 1400, 3000, or 5000 kHz since there
would be insufficient CCEs to transmit a PDCCH for common
channel messages such as SIB1 or SI. Certain values of
pdcchCfiMode that allow high CFI values may be disallowed
when the combination of attributes pdcchCfiMode,
dlChannelBandwidth, noOfPucchCqiUsers, and
noOfPucchSrUsers require too many corresponding PUCCH
HARQ-ARQ resources.
Takes effect: Object unlocked
long physicalLayerCellIdGroup { 0..167 }
mandatory
The physical layer cell ID group. Physical-layer cell IDs are
grouped into 168 unique physical-layer cell-identity groups,
each group containing 3 unique subidentities.

This attribute together with physicalLayerSubCellId is used to


calculate physical layer cell ID (see 3GPP TS 36.211) that is sent
as part of the system information (see 3GPP TS 36.331).

Disturbances: Changes may affect traffic


Takes effect: Immediately
long physicalLayerSubCellId { 0..2 }
mandatory

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 14 of 162

The subidentity within the physical layer cell ID group. Physical-


layer cell IDs are grouped into 168 unique physical-layer cell-
identity groups, each group containing 3 unique subidentities.

This attribute together with physicalLayerCellIdGroup is used to


calculate physical layer cell identity (see 3GPP TS 36.211) which
is sent as part of the system information (see 3GPP TS 36.331).

Disturbances: Changes may affect traffic


Takes effect: Immediately
long pMaxServingCell = 1000 { -30..33, 1000 }
Limits UE uplink transmission power in the serving cell and
calculates the parameter Pcompensation (defined in 3GPP TS
36.304) for cell selection.
The attribute is broadcast in SIB1.

Value 1000 means the parameter is not included in system


information.

Takes effect: Immediately


boolean primaryPlmnReserved = false
Indicates if the primary PLMN ID in the cell is reserved for
operator use. The primary PLMN ID is reserved if this attribute
is set to true.

Dependencies: the attribute eNodeBPlmnId in the parent


ENodeBFunction will hold the value of the primary PLMN ID.
Takes effect: Immediately
BandwidthVals prsBandwidth = N100
The Positioning Reference Signal (PRS) bandwidth in the cell.
Values are specified in number of resource blocks. N6
corresponds to 6 resource blocks, N15 corresponds to 15
resource blocks and so on. The values define the 1.4, 3, 5, 10,
15 and 20 MHz bandwidths.

Deprecated: Since L11B. Has no functional behaviour.

Dependencies: None
Takes effect: Object unlocked
long prsConfigIndex = -1 { -1..4095 }
The Positioning Reference Signal (PRS) index value for the cell
defines the periodicity of the PRS occasions and the PRS
subframe offset, as defined in 3GPP TS 36.211. The value -1
(default) means that this parameter will not be used for setting
the PRS period and prsSubframeOffset. Instead the parameter
prsPeriod shall be used to directly set the PRS period while
prsSubframeOffset will be set by the system to guarantee non
collision with SIB1.

Takes effect: Object unlocked


long prsConfigIndexMapped { 0..4095 }
readOnly
This parameter holds the resulting prsConfigIndex value. If
prsPeriod is used by the operator then prsConfigIndexMapped
will be set by the system. If prsConfigIndex is used by the
operator then prsConfigIndexMapped will be a copy of the
entered value.
PrsPerVals prsPeriod = PP1280

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 15 of 162

The period of Positioning Reference Signal (PRS) occasions.


Valid periods include 160 ms, 320 ms, 640 ms and 1280 ms.

prsPeriod is used to calculate the prsConfigIndex to avoid PRS


sub-frame collisions with SIB1 sub-frames.

Takes effect: Object unlocked


long pucchOverdimensioning = 0 { 0, 13 }
Number of resource blocks outside each Physical Uplink Control
Channel (PUCCH) region that are available for scheduling
Physical Uplink Shared Channel (PUSCH).

Limited to moving the Physical Random Access Channel


(PRACH) frequency allocation (located just after the PUCCH) up
to the 5 MHz border at most. The PRACH can never be located
at Physical Resource Block (PRB) index 25 and above.

Unit: 1 Resource Block


Takes effect: Object disabled/enabled.
long pZeroNominalPucch = -117 { -127..-96 }
The nominal component of the UE transmit power for Physical
Uplink Control Channel (PUCCH).

Unit: 1 dBm
Disturbances: Changes may affect traffic.
Takes effect: Immediately
long pZeroNominalPusch = -103 { -126..24 }
The nominal component of the UE transmit power for Physical
Uplink Shared Channel (PUSCH).

Unit: 1 dBm
Disturbances: Changes may affect traffic.
Takes effect: Immediately
QciTable qciTableRef
Refers to an instance of QciTable and assigns a QciTable to a
cell. The QciTable defines Quality of Service Class Indicator
(QCI) to use in the cell.

Refers to the QciTable instance corresponding to Local


Distinguished Name (LDN) = ManagementElement=1,
ENodeBFunction=1, QciTable=default

Dependencies: It is assumed that the QciTable MO has been


created.
Takes effect: New connection.
long qQualMin = -34 { -34..-3 }
Specifies the minimum required quality level (RSRQ) in the cell
in dB.

Corresponds to qQualMin in TS 36.304, sent in SIB1.

Unit: 1 dB
Dependencies: The field is mandatory present if the Struct
Member threshServingLowQ in SIB3 is used in
systemInformationBlockType3.
Takes effect: Immediately
long qQualMinOffset = 0 { 0..8 }

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 16 of 162

The offset applied to the signalled qQualMin.

Corresponds to Qqualminoffset in TS 36.304.

Value 0 means that it is not sent in SIB1 and UE applies in such


case the (default) value of 0 dB for Qqualminoffset.

Unit: 1 dB
Dependencies: If the value of qQualMin is set to 0 the
parameter qQualMinOffset will not be broadcasted.
Takes effect: Immediately
long qRxLevMin = -140 { -140..-44 }
The required minimum received Reference Symbol Received
Power (RSRP) level in the E-UTRA frequency for cell reselection.
Corresponds to parameter Qrxlevmin in 3GPP TS 36.304. This
attribute is broadcast in SIB1.

Unit: 1 dBm

Resolution: 2
Takes effect: Immediately
long qRxLevMinOffset = 1000 { 2..16, 1000 }
The offset applied to the signalled Qrxlevmin. Corresponds to
parameter Qrxlevminoffset in 3GPP TS 36.304. Value 1000
means it is not sent and the UE sets Qrxlevminoffset=0dB.

Unit: 1 dB

Resolution: 2
Takes effect: Immediately
long rachRootSequence = 386 { 0..837 }
The first root sequence number for Random Access Channel
(RACH) preamble generation. RACH root sequence is broadcast
as a part of system information distribution and used for
preamble detection.
See definition for logical root sequence number in 3GPP TS
36.211.

Disturbances: Changes may affect traffic.


Takes effect: Object unlocked.
boolean rateShapingActive = false
Indicates if End-user bitrate shaping functionality is activated in
this cell.

Dependencies: Only relevant if the license for End-user bitrate


shaping is present and the feature is active.
Takes effect: Cell lock/unlock
ManagedObject redirectionInfoRefPrio1
Reference to an Managed Object instance containing redirection
information for this EUtranCell. This reference should be set to a
Cdma2000Freq, EUtranFrequency, UtranFrequency or
GeranFrequencyGroup instance. Redirect to the same frequency
is possible.

Deprecated: Since L11B. Planned to be removed.

Takes effect: Ongoing connection

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 17 of 162

ManagedObject redirectionInfoRefPrio2
Reference to an Managed Object instance containing redirection
information for this EUtranCell. This reference should be set to a
Cdma2000Freq, EUtranFrequency, UtranFrequency or
GeranFrequencyGroup instance. Redirect to the same frequency
is possible.

Deprecated: Since L11B. Planned to be removed.

Takes effect: Ongoing connection


ManagedObject redirectionInfoRefPrio3
Reference to an Managed Object instance containing redirection
information for this EUtranCell. This reference should be set to a
Cdma2000Freq, EUtranFrequency, UtranFrequency or
GeranFrequencyGroup instance. Redirect to the same frequency
is possible.

Deprecated: Since L11B. Planned to be removed.

Takes effect: Ongoing connection


ManagedObject[0..] reservedBy
readOnly
Contains a list of managed object instances that reserves this
managed object instance.

Dependencies: The managed object cannot be deleted if it is


reserved.
boolean sdmActive = false
Specifies if SDM (Spatial Division Multiplexing) for CombinedCell
configuration is activated or not. If SDM is activated, it is
possible to multiplex multiple Ues in different sectors in the
same time and same frequency resource.

Disturbances: Change can affect traffic


Takes effect: Object disabled/enabled
SectorCarrier[0..12] sectorCarrierRef
Reference to a list of instances of SectorCarrier MO.
In L13A, it is not allowed to have more than one SectorCarrier
referred by a Cell.
Multiple SectorCarrier in a cell will be supported in L13B.

Disturbances: Change can affect traffic


Takes effect: Object disabled/enabled
SectorEquipmentFunction sectorFunctionRef
Reference to an instance of SectorEquipmentFunction MO.

Deprecated: Since L13A. Planned to be removed. Replaced by


SectorCarrier::sectorFunctionRef. The value of
sectorFunctionRef from the first SectorCarrier in the
EUtranCellFDD/EUtranCellTDD::sectorCarrierRef will be mapped
to this deprecated attribute.

PeriodicitySI siPeriodicity
The periodicity of System Information (SI) messages. If a
System Information Block (SIB) is not mapped to a SI message,

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 18 of 162

the SI message is not transmitted.

Takes effect: When EUtranCellFDD/TDD object is unlocked.


long siWindowLength = 10 { 1, 2, 5, 10, 15, 20, 40 }
Length of the System Information (SI) window within which
each SI message is transmitted. Applies to all SI messages.

Note: An SI window of 1 ms may be configured only when a


maximum of 5 SI messages is configured for broadcast by
attribute mappingInfo, to avoid collision with SIB1 transmission
in subframe #5.

Unit: 1 ms
Dependencies: siWindowLength * ‘transmitted number of SI-
messages’ <= MIN(siPeriodicitySIx), i.e it must be possible
schedule all SI messages within the shortest siPeriodicity time
used.
Takes effect: When EUtranCellFDD/TDD object is unlocked
AcBarringConfig ssacBarringForMMTELVideo
Service specific access class barring parameters for MMTEL
video originating calls.
The information in broadcasted in SIB2.

Takes effect: Immediately


boolean ssacBarringForMMTELVideoPresent = false
Specifies presence of Information Element ssac-
BarringForMMTEL-Video-r9 in SIB2.

Takes effect: Immediately


AcBarringConfig ssacBarringForMMTELVoice
Service specific access class barring parameters for MMTEL
voice originating calls.
The information in broadcasted in SIB2.

Takes effect: Immediately


boolean ssacBarringForMMTELVoicePresent = false
Specifies presence of Information Element ssac-
BarringForMMTEL-Voice-r9 in SIB2.

Takes effect: Immediately


SIB3 systemInformationBlock3
Contains cell re-selection information common for intra-
frequency, inter-frequency and/ or inter-RAT cell re-selection.

Takes effect: Object lock/unlock


SIB6 systemInformationBlock6
Contains cell re-selection information common for cell re-
selection towards UTRAN.

Takes effect: Object lock/unlock


SIB7 systemInformationBlock7
Contains cell re-selection information common for cell re-
selection towards GERAN.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 19 of 162

Takes effect: Object lock/unlock


SIB8 systemInformationBlock8
Contains cell re-selection information common for cell re-
selection towards CDMA2000. This is controlled by the licensing
MO Cdma2000SessionContinuity. The SIB8 distribution and
information is also controlled by other licenses.

Takes effect: Object lock/unlock


long tac { 0..65535 }
mandatory
Tracking Area Code for the EUtran Cell. All cells within an
eNodeB must have equal tac values. If tac needs to be changed,
then the change must be performed on all cells in the eNodeB
within a transaction.

Disturbances: Changes may affect traffic


Takes effect: Immediately
long threshServingLow = 0 { 0..62 }
Specifies the threshold that the signal strength of the serving
cell must be below for cell reselection towards a lower priority
Inter-Frequency or Inter-RAT frequency.
Corresponds to ThreshServingLowP in TS 36.304.

Unit: 1 dB

Resolution: 2
Takes effect: Immediately
string timeOfLastModification = "" [ 0..19 ]
Indicates the time and date when the MO was last modified.
Format: YYYY-MM-DD HH:MM:SS

Takes effect: Immediately


long ulChannelBandwidth = 10000 { 1400, 3000, 5000, 10000,
15000, 20000 }
The uplink channel bandwidth in the cell.

Valid values: 1400, 3000, 5000, 10000, 15000, 20000

Unit: 1 kHz
Dependencies: This attribute is dependent on and shall be set to
the same as dlChannelBandwidth.
Disturbances: Changes may affect traffic.
Takes effect: Object disabled/enabled.
long ulConfigurableFrequencyStart = 0 { 0..100 }
Specifies the start frequency offset for the allocation of
resources when the uplink interference management is disabled
expressed as a percentage of the configured bandwidth.

Unit: 1 percent
Dependencies: ulInterferenceManagementActive shall be
disabled before this parameter takes effect.
Takes effect: Object unlocked
long ulFrequencyAllocationProportion = 100 { 0..100 }
Specifies the amount of frequency resources that is allocated in
UL expressed as a percentage of the configured bandwidth.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 20 of 162

Unit: 1 percent
Takes effect: Object unlocked
boolean ulInterferenceManagementActive = true
Specifies if uplink interference management is enabled or
disabled.

Takes effect: Object unlocked


boolean ulSrsEnable = false
This parameter controls whenever sounding shall be enabled or
not. When enabled, cell resources are configured for sounding.

Dependencies: Only relevant if the license for frequency


selective scheduling is present and active
Takes effect: Cell lock/unlock
long uncertAltitude = 0 { 0..127 }
The uncertainty altitude (h) expressed in meters is derived from
the uncertainty altitude (k) by h = 45*((1.025)^k - 1).

Unit: 45 * ((1.025)^k - 1) .
Takes effect: Immediately
long uncertSemiMajor = 0 { 0..127 }
Semi-major axis of uncertainty. The uncertainty (r) is derived
from the uncertainty code (k) by:

r = 10 * ((1.1^k) - 1).

Unit: 10 * ((1.1^k) - 1) meters


Takes effect: Immediately
long uncertSemiMinor = 0 { 0..127 }
Semi-minor axis of uncertainty. The uncertainty (r) is derived
from the uncertainty code (k) by:

r = 10 * ((1.1^k) - 1).

Unit: 10 * ((1.1^k) - 1) meters


Takes effect: Immediately
string userLabel = "" [ 0..128 ]
Label for free use.
long zzzTemporary13 = -2000000000
Temporary attributes are intended for temporary solutions, and
their usage may vary depending on the installed software. It is
strongly recommended to only set the attributes that
correspond to a desired functionality and leave all other
temporary attributes set to default value. Information in the
descriptions about what attributes are in use may be overridden
by the information in CPI Info documents. Note that a later
release may use another attribute to control the functionality
previously provided by a temporary attribute, or may remove
the functionality altogether. In these cases, the change is
documented in the NIR.

Takes effect: Immediately


long zzzTemporary14 = -2000000000
Temporary attributes are intended for temporary solutions, and
their usage may vary depending on the installed software. It is
strongly recommended to only set the attributes that
correspond to a desired functionality and leave all other

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 21 of 162

temporary attributes set to default value. Information in the


descriptions about what attributes are in use may be overridden
by the information in CPI Info documents. Note that a later
release may use another attribute to control the functionality
previously provided by a temporary attribute, or may remove
the functionality altogether. In these cases, the change is
documented in the NIR.

Takes effect: Immediately


long zzzTemporary15 = -2000000000
Temporary attributes are intended for temporary solutions, and
their usage may vary depending on the installed software. It is
strongly recommended to only set the attributes that
correspond to a desired functionality and leave all other
temporary attributes set to default value. Information in the
descriptions about what attributes are in use may be overridden
by the information in CPI Info documents. Note that a later
release may use another attribute to control the functionality
previously provided by a temporary attribute, or may remove
the functionality altogether. In these cases, the change is
documented in the NIR.

Takes effect: Immediately


long zzzTemporary16 = -2000000000
Temporary attributes are intended for temporary solutions, and
their usage may vary depending on the installed software. It is
strongly recommended to only set the attributes that
correspond to a desired functionality and leave all other
temporary attributes set to default value. Information in the
descriptions about what attributes are in use may be overridden
by the information in CPI Info documents. Note that a later
release may use another attribute to control the functionality
previously provided by a temporary attribute, or may remove
the functionality altogether. In these cases, the change is
documented in the NIR.

Takes effect: Immediately


long zzzTemporary17 = -2000000000
Temporary attributes are intended for temporary solutions, and
their usage may vary depending on the installed software. It is
strongly recommended to only set the attributes that
correspond to a desired functionality and leave all other
temporary attributes set to default value. Information in the
descriptions about what attributes are in use may be overridden
by the information in CPI Info documents. Note that a later
release may use another attribute to control the functionality
previously provided by a temporary attribute, or may remove
the functionality altogether. In these cases, the change is
documented in the NIR.

Takes effect: Immediately

PM counters
long pmActiveDrbDlSum
noNotification
nonPersistent The sum of the contributions from each UE in the cell of the number of
readOnly active DRBs in the downlink direction.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 22 of 162

Condition: Each TTI, the counter shall be increased wih the number of DRBs
that are considered active (i.e. that have data in the downlink buffer).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmActiveDrbDlSumQci
nonUnique
noNotification The sum of number of DL active DRBs per QCI. A DL DRB is active if there
nonPersistent are buffered DL data for the DRB. (Due to implementation, there are either
readOnly 9052 or 9053 samples per ROP)
Compressed: True

Condition: The bin accumulates the number of active DRBs in DL per QCI.
Counter type: PDF
Sampling rate: 0.1
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmActiveDrbUlSum
noNotification
nonPersistent The sum of the contributions from each UE in the cell of the number of
readOnly active DRBs in the uplink direction.

Condition: Each TTI, the counter shall be increased wih the number of DRBs
that are considered active (i.e. that are considered to have data in the
uplink buffer).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmActiveUeDlMax
noNotification
nonPersistent Peak number of UEs considered active in the downlink direction, i.e. has
readOnly designated data in UE dedicated buffer in the eNB. The value is a maximum
of a set of samples, where each sample is an average of active UEs per ms
(throughout the frame), during a sample period shorter than the ROP.

Condition: The counter is set equal to the peak sample recognized at the
end of each Recording Output Period (ROP).
Counter type: GAUGE
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..6] pmActiveUeDlSectorCarrierDistr
nonUnique
noNotification The counter shows the distribution of DL UEs that are in 1 to N sectors.
nonPersistent
readOnly [0]: Sum of active DL UEs that is connected to 1 sector
[1]: Sum of active DL UEs that is connected to 2 sectors
-----
[5]: Sum of active DL UEs that is connected to 6 sectors or more.

Condition: Accumulate with the number of DL UEs in 1 to N sectorsCarrier


per TTI.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmActiveUeDlSum
noNotification

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 23 of 162

nonPersistent Number of UEs considered active in the downlink direction.


readOnly

Condition: The counter aggregates for each TTI the number of UEs with
DRB data to send.
Counter type: ACC
Sampling rate: Per TTI
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmActiveUeDlSumQci
nonUnique
noNotification The sum of number of DL active UE per QCI. A DL active UE for a QCI is a
nonPersistent UE that has buffered DL data for the QCI. (Due to implementation, there
readOnly are either 9052 or 9053 samples per ROP)
Compressed: True

Condition: The bin accumulates the number of active UE in DL per QCI.


Counter type: PDF
Sampling rate: 0.1
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmActiveUeDrbSamp
noNotification
nonPersistent The total number of active UE or active DRB measurement samples. (Due
readOnly to implementation, there are either 9052 or 9053 samples per ROP)

Condition: The counter is stepped for each active UE or active DRB


measurement.
Counter type: ACC
Sampling rate: 0.1
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmActiveUeUlMax
noNotification
nonPersistent Peak number of UEs considered active in the uplink direction, i.e. the UE is
readOnly considered to have data in its buffer. The value is a maximum of a set of
samples, where each sample is an average of active UEs per ms
(throughout the frame), during a sample period shorter than the ROP.

Condition: The counter is set to peak sample recognized at the end of each
Recording Output Period (ROP).
Counter type: GAUGE
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..6] pmActiveUeUlSectorCarrierDistr
nonUnique
noNotification The counter shows the distribution of UL UEs that are in 1 to N sectors.
nonPersistent
readOnly [0]: Sum of active UL UEs that is connected to 1 sector
[1]: Sum of active UL UEs that is connected to 2 sectors
-----
[5]: Sum of active UL UEs that is connected to 6 sectors or more.

Condition: Accumulate with the number of UL UEs in 1 to N sectorsCarrier


per TTI.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmActiveUeUlSum
noNotification

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 24 of 162

nonPersistent Number of UEs considered active in the uplink direction.


readOnly

Condition: The counter aggregates for each TTI the number of UEs with
buffer status reports indicating DRB data to be sent in the uplink direction.
Counter type: ACC
Sampling rate: Per TTI
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..4] pmActiveUeUlSumLcg
nonUnique
noNotification The sum of number of UL active UE per LCG (Logical Channel Group). An UL
nonPersistent active UE for a LCG is a UE that has buffered UL data for the LCG. (Due to
readOnly implementation, there are either 9052 or 9053 samples per ROP)

Condition: The bin accumulates the number of active UE in UL per LCG.


There are 4 LCG (Logic Channel Group) new.
Counter type: PDF
Sampling rate: 0.1
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmAnrNeighbrelAdd
noNotification
nonPersistent Number of neighbour relations added by the ANR function.
readOnly

Unit: 1 Neighbour Relation


Condition: Stepped when the ANR function establishes a neighbour relation.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmAnrNeighbrelRem
noNotification
nonPersistent Number of neighbour relations removed by the ANR function.
readOnly

Unit: 1 Neighbour Relation


Condition: Stepped when the ANR function deletes a neighbour relation.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmBadCovEvalReport
noNotification
nonPersistent The total number of traffic Bad Coverage measurement reports received.
readOnly

Condition: Stepped at reception of traffic measurement report from UE


indicating that bad coverage due to Event A2, 'Serving becomes worse than
absolute threshold'.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmBadCovSearchEvalReport
noNotification
nonPersistent The total number of A2 measurement reports received due to entering the
readOnly Search zone.
This counter is used when the feature Mobility Control at Poor Coverage is
activated.

Condition: Stepped at reception of traffic measurement report from UE


indicating bad coverage due to Event A2_Search (either RSRP or RSRQ

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 25 of 162

triggered).

Counter type: PEG


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmBestCellEvalReport
noNotification
nonPersistent The total number of traffic Best Cell measurement reports received.
readOnly

Condition: Stepped at reception of traffic measurement report indicating a


better cell due to Event A3, 'Neighbor becomes amount of offset better than
serving'.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..5] pmCaActivatedDlSum
nonUnique
noNotification Number of activated secondary component carriers (SCell), for UE using
nonPersistent this cell as their primary component carrier (PCell)
readOnly
[0] Number of carrier aggregation configured UE that have no activated
SCells
[1] Number of carrier aggregation configured UE that have one activated
SCell
[2] Number of carrier aggregation configured UE that have two activated
SCells
[3] Number of carrier aggregation configured UE that have three activated
SCells
[4] Number of carrier aggregation configured UE that have four activated
SCells
Compressed: True

Filter: FDD
Condition: Stepped in each subframe (TTI) for UEs using this cell as a
primary component carrier (PCell) and which are configured with at least
one secondary component carrier (SCell).

Counter type: PDF


Sampling rate: 0.001
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmCaCapableDlSamp
noNotification
nonPersistent The number of carrier aggregation capable UE measurement samples.
readOnly
Filter: FDD
Condition: The counter is stepped for each carrier aggregation capable UE
measurement sample.
Counter type: PEG
Sampling rate: 5
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..5] pmCaCapableDlSum
nonUnique
noNotification Number of supported secondary component carriers (SCell), for UE using
nonPersistent this cell as their primary component carrier (PCell)
readOnly
[0] Number of UE that are not carrier aggregation capable at all (i.e. PCell
only)

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 26 of 162

[1] Number of UE that are capable of PCell plus one SCell


[2] Number of UE that are capable of PCell plus two SCells
[3] Number of UE that are capable of PCell plus three SCells
[4] Number of UE that are capable of PCell plus four SCells
Compressed: True

Filter: FDD
Condition: This measurement provides the mean number of UEs capable of
downlink carrier aggregation, counted per the number of component
carriers (PCell and SCells).

Counter type: PDF


Sampling rate: 5
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmCaConfiguredDlSamp
noNotification
nonPersistent The number of carrier aggregation configured UE measurement samples.
readOnly
Filter: FDD
Condition: The counter is stepped for each carrier aggregation configured
UE measurement sample.
Counter type: PEG
Sampling rate: 5
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..5] pmCaConfiguredDlSum
nonUnique
noNotification Number of configured secondary component carriers (SCell) for UE using
nonPersistent this cell as their primary component carrier (PCell)
readOnly
[0] Number of carrier aggregation capable UE that are not configured with
any SCell
[1] Number of carrier aggregation capable UE that are configured with one
SCell
[2] Number of carrier aggregation capable UE that are configured with two
SCells
[3] Number of carrier aggregation capable UE that are configured with
three SCells
[4] Number of carrier aggregation capable UE that are configured with four
SCells
Compressed: True

Filter: FDD
Condition: This measurement provides the mean number of UEs configured
for downlink carrier aggregation, out of the number of carrier aggregation
capable UEs, counted per the number of component carriers (PCell and
SCells) configured in each UE.
Counter type: PDF
Sampling rate: 5
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..5] pmCaScheduledDlSum
nonUnique
noNotification Mean number of UE that have data scheduled on downlink, counted by the
nonPersistent number of component carriers simultaneously scheduled.
readOnly UE is considered scheduled for carrier aggregation if the eNodeB has sent a
PDCCH assignment indicating a PDSCH assignment

[0] Number of carrier aggregation activated UE that have one scheduled


cell

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 27 of 162

[1] Number of carrier aggregation activated UE that have two


simultaneously scheduled cells
[2] Number of carrier aggregation activated UE that have three
simultaneously scheduled cells
[3] Number of carrier aggregation activated UE that have four
simultaneously scheduled cells
[4] Number of carrier aggregation activated UE that have five
simultaneously scheduled cells
Compressed: True

Filter: FDD
Condition: Stepped in each subframe (TTI) for UEs using this cell as a
primary component carrier (PCell) and which are activated with at least one
secondary component carrier (SCell).

Counter type: PDF


Sampling rate: 0.001
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmCellAdmControlPdcchRej
noNotification
nonPersistent Counter is stepped whenever we have a reject due to that pdcch is limiting
readOnly new connections.

Unit: 1 Rejects
Condition: The counter is stepped in dl scheduler when a ue is going to be
setup, if the pdcchAdmEnabled attribute is set to true, and the usage of
CCEs for high prioritized Ues is above the threshold pdcchAdmThreshold. A
reject is also sent to higher layers.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmCellAdmControlPdcchRejMeas
noNotification
nonPersistent Counter is stepped whenever we would have had a reject due to that pdcch
readOnly is limiting new connections.

Unit: 1 Potential Rejects


Condition: The counter is stepped in dl scheduler when a ue is going to be
setup, if the pdcchAdmEnabled attribute is set to false, and the usage of
CCEs for high prioritized Ues is above the threshold pdcchAdmThreshold.
No reject is sent.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmCellDownLockAuto
noNotification
nonPersistent The number of times the cell has been disabled due to a fault (system has
readOnly set cell MO OperationalState to Disabled).

Condition: Incremented at change of the OperationalState is set to


Disabled.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmCellDownLockMan
noNotification
The number of times the cell has been disabled due to:
- AdministrativeState of the cell MO or another MO the cell depends on has

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 28 of 162

nonPersistent been set to Locked by the operator


readOnly
or
- the operator has performed a reconfiguration request on an Unlocked cell
which requires the cell to be taken down temporarily.

Condition: Incremented at change of the AdministritiveState to Locked.


Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmCellDowntimeAuto
noNotification
nonPersistent Length of time the cell has been disabled due to a fault (system has set cell
readOnly MO OperationalState to Disabled). The counter is only incremented when
the RBS is operational.

Unit: 1 s
Condition: Incremented by one each second.
Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long pmCellDowntimeMan
noNotification
nonPersistent Length of time the cell has been disabled due to:
readOnly - AdministrativeState of the cell MO or another MO the cell depends on has
been set to Locked by the operator
or
- the operator has performed a reconfiguration request on an Unlocked cell
which requires the cell to be taken down temporarily.
The counter is only incremented when the RBS is operational.

Unit: 1 s
Condition: Incremented by one each second.
Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long pmCellDownUnlockMan
noNotification
nonPersistent The number of times the cell has been enabled.
readOnly
Condition: Incremented at change of the AdministritiveState to Unlocked.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..8] pmCompUlDeltaSinrPuschDistr
nonUnique
noNotification Distribution of the SINR difference for PUSCH between Uplink Coordinated
nonPersistent Multi-Point Reception and Interference Rejection Combining within
readOnly SectorCarrier.
PDF ranges:
[0]: DeltaSINR <= -1;
[1]: -1<DeltaSINR <= 0;
[2]: 0 < DeltaSINR 2 <= 2;
[3]: 2 < DeltaSINR <= 4;
[4]: 2 < DeltaSINR <= 4;
[5]: 4 < DeltaSINR <= 6;
[6]: 6 < DeltaSINR <= 8;
[7]: 8 < DeltaSINR <= 10;

Unit: 1 dB

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 29 of 162

Condition: Appropriate bin incremented when DeltaSinr is within certain


bounds
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmContDl
noNotification
nonPersistent The counter aggregates the number of ms for which contention has
readOnly occurred in the downlink direction due to lack of eNodeB resources.

Unit: 1 ms
Condition: Any TTI for which contention (i.e. data not scheduled for a Radio
Bearer) occurs due to lack of DL capacity license, hardware capacity or
PDCCH resources is counted. Note that result is dependent on the
configuration of Subframe assignment (i.e. How many TTIs are available to
scheduling).
Counter type: PEG
Sampling rate: Per TTI
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmContDlCapLic
noNotification
nonPersistent The counter aggregates the number of ms for which contention has
readOnly occurred in the downlink direction due to lack of DL capacity license.

Unit: 1 ms
Condition: Any TTI for which contention (i.e. data not scheduled for a Radio
Bearer) occurs due to lack of DL capacity license is counted. Note that
result is dependent on the configuration of Subframe assignment (i.e. How
many TTIs are available to scheduling).
Counter type: PEG
Sampling rate: Per TTI
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmContDlHw
noNotification
nonPersistent The counter aggregates the number of ms for which contention has
readOnly occurred in the downlink direction due to lack of hardware resources.

Unit: 1 ms
Condition: Any TTI for which contention (i.e. data not scheduled for a Radio
Bearer) occurs due to lack of hardware resources is counted. Note that
result is dependent on the configuration of Subframe assignment (i.e. How
many TTIs are available to scheduling).
Counter type: PEG
Sampling rate: Per TTI
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmContDlPdcch
noNotification
nonPersistent The counter aggregates the number of ms for which contention has
readOnly occurred in the downlink direction due to lack of PDCCH resources.

Unit: 1 ms
Condition: Any TTI for which contention (i.e. data not scheduled for a Radio
Bearer) occurs due to lack of PDCCH resources is counted. Note that result

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 30 of 162

is dependent on the configuration of Subframe assignment (i.e. How many


TTIs are available to scheduling).
Counter type: PEG
Sampling rate: Per TTI
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmContUl
noNotification
nonPersistent The counter aggregates the number of ms for which contention has
readOnly occurred in the uplink direction due to lack of eNodeB resources.

Unit: 1 ms
Condition: Any TTI for which contention (i.e. data not scheduled for a Radio
Bearer) occurs due to lack of UL capacity license, hardware capacity or
PDCCH resources is counted. Note that result is dependent on the
configuration of Subframe assignment (i.e. How many TTIs are available to
scheduling).
Counter type: PEG
Sampling rate: Per TTI
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmContUlCapLic
noNotification
nonPersistent The counter aggregates the number of ms for which contention has
readOnly occurred in the uplink direction due to lack of license resources.

Unit: 1 ms
Condition: Any TTI for which contention (i.e. data not scheduled for a Radio
Bearer) occurs due to lack of UL capacity license is counted. Note that
result is dependent on the configuration of Subframe assignment (i.e. How
many TTIs are available to scheduling).
Counter type: PEG
Sampling rate: Per TTI
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmContUlHw
noNotification
nonPersistent The counter aggregates the number of ms for which contention has
readOnly occurred in the uplink direction due to lack of hardware resources.

Unit: 1 ms
Condition: Any TTI for which contention (i.e. data not scheduled for a Radio
Bearer) occurs due to lack of hardware resources is counted. Note that
result is dependent on the configuration of Subframe assignment (i.e. How
many TTIs are available to scheduling).
Counter type: PEG
Sampling rate: Per TTI
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmContUlPdcch
noNotification
nonPersistent The counter aggregates the number of ms for which contention has
readOnly occurred in the uplink direction due to lack of PDCCH resources.

Unit: 1 ms
Condition: Any TTI for which contention (i.e. data not scheduled for a Radio
Bearer) occurs due to lack of PDCCH resources is counted. Note that result
is dependent on the configuration of Subframe assignment (i.e. How many
TTIs are available to scheduling).

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 31 of 162

Counter type: PEG


Sampling rate: Per TTI
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmCriticalBorderEvalReport
noNotification
nonPersistent The total number of A2 measurement reports received due to critical
readOnly threshold is reached.
This counter is used instead of pmBadCovEvalReport when the feature
Mobility Control at Poor Coverage is activated.

Condition: Stepped at reception of traffic measurement report from UE


indicating bad coverage due to Event A2_Critical (either RSRP or RSRQ
triggered).

Counter type: PEG


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmDlAssigsTrans
noNotification
nonPersistent The total number of unicast DL assignments transmitted.
readOnly
Condition: It is pegged when a unicast DL assignment to a specific UE is
transmitted excluding DL assignments for message 2.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmDlAssigsWithDetectedHarqAck
noNotification
nonPersistent The total number of unicast DL assignments that are confirmed by
readOnly detecting a corresponding HARQ-ACK.

Condition: It is pegged when a unicast DL assignment is confirmed by


detecting a corresponding HARQ-ACK.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmDlAssigsWithUnknownReception
noNotification
nonPersistent The total number of unicast DL assignments for which the reception is
readOnly unknown.

Condition: It is pegged if eNB can't determine if a HARQ-ACK associated


with a unicast DL assignment is detected or not.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmDrbThpTimeDlQci
nonUnique
noNotification The DL transmission time used for DL DRB Throughput per QCI. It
nonPersistent comprises of time periods from when the first piece of data in a data burst
readOnly is transmitted until the second last piece of data in the data burst is
transmitted.

When carrier aggregation is used, the DL transmission time used for DL


DRB Throughput per QCI is registered on the UE's primary component
carrier (PCell).

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 32 of 162

Compressed: True

Unit: 1 ms

Filter: FDD
Condition: The bin accumulates the DL transmission time per QCI for each
large data burst that needs to be transmitted across multiple TTIs.
Counter type: PDF
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmDrxSleepTime
noNotification
nonPersistent Contains the DRX sleep time in number of subframes for all UEs in the cell.
readOnly

Condition: Counter should be incremented every subframe for every UE in


the cell for which DRX functionality in RRC_CONNECTED state is configured
and the UE is in DRX sleep time.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..42] pmDrxSleepTimeAvailDataDlCfgIdx
nonUnique
noNotification To count the number of subframes where all UEs in a cell, differentiated by
nonPersistent DRX configuration index, are in DRX sleep and DL data is available in the
readOnly RLC buffers. Each DRX profile is associated with two DRX configurations -
one for UEs with long DRX capability only, and the other for UEs that have
short and long DRX capability.

Compressed: True

Unit: 1 ms

Deprecated: Since L13B. Has no functional behavior. Planned to be


removed.

Condition: Counter should be incremented every subframe for every UE in


the cell for which DRX functionality is in RRC_CONNECTED state,
differentiated by DRX configuration index, where the UE is in DRX sleep
time and DL data is available in the RLC buffers. Time during ANR operation
for a specific UE is excluded.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..42] pmDrxSleepTimeCfgIdx
nonUnique
noNotification To count the number of subframes where all UEs in a cell, differentiated by
nonPersistent DRX configuration index, are in DRX sleep. Each DRX profile is associated
readOnly with two DRX configurations - one for UEs with long DRX capability only,
and the other for UEs that have short and long DRX capability.

Compressed: True

Unit: 1 ms

Deprecated: Since L13B. Has no functional behavior. Planned to be


removed.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 33 of 162

Condition: Counter should be incremented every subframe for every UE in


the cell for which DRX functionality is in RRC_CONNECTED state,
differentiated by DRX configuration index, and the UE is in DRX sleep time.
Time during ANR operation for a specific UE is excluded.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmDrxTotalTime
noNotification
nonPersistent Contains the DRX total time in number of subframes for all UEs in the cell.
readOnly

Condition: Counter should be incremented every subframe for every UE in


the cell for which DRX functionality in RRC_CONNECTED state is configured.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..42] pmDrxTotalTimeCfgIdx
nonUnique
noNotification To count the number of subframes where all UEs in a cell, differentiated by
nonPersistent DRX configuration index, are in DRX mode. Each DRX profile is associated
readOnly with two DRX configurations - one for UEs with long DRX capability only,
and the other for UEs that have short and long DRX capability.

Compressed: True

Unit: 1 ms

Deprecated: Since L13B. Has no functional behavior. Planned to be


removed.

Condition: Counter should be incremented every subframe for every UE in


the cell for which DRX functionality is in RRC_CONNECTED state,
differentiated by DRX configuration index. Time during ANR operation for a
specific UE is excluded.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionAttArp0
noNotification
nonPersistent The total number of E-RAB admission attempts for ARP (Allocation
readOnly Retention Priority)=0

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each E-RAB with ARP=0 at reception of E-RAB


SETUP REQUEST, INITIAL CONTEXT SETUP REQUEST or HANDOVER
REQUEST.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionAttArp1
noNotification
nonPersistent The total number of E-RAB admission attempts for ARP (Allocation
readOnly Retention Priority)=1

Deprecated: Since L11B. Has no functional behavior, planned to be

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 34 of 162

removed.

Condition: Stepped for each E-RAB with ARP=1 at reception of E-RAB


SETUP REQUEST, INITIAL CONTEXT SETUP REQUEST or HANDOVER
REQUEST.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionAttArp10
noNotification
nonPersistent The total number of E-RAB admission attempts for ARP (Allocation
readOnly Retention Priority)=10

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each E-RAB with ARP=10 at reception of E-RAB


SETUP REQUEST, INITIAL CONTEXT SETUP REQUEST or HANDOVER
REQUEST.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionAttArp11
noNotification
nonPersistent The total number of E-RAB admission attempts for ARP (Allocation
readOnly Retention Priority)=11

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each E-RAB with ARP=11 at reception of E-RAB


SETUP REQUEST, INITIAL CONTEXT SETUP REQUEST or HANDOVER
REQUEST.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionAttArp12
noNotification
nonPersistent The total number of E-RAB admission attempts for ARP (Allocation
readOnly Retention Priority)=12

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each E-RAB with ARP=12 at reception of E-RAB


SETUP REQUEST, INITIAL CONTEXT SETUP REQUEST or HANDOVER
REQUEST.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionAttArp13
noNotification
nonPersistent The total number of E-RAB admission attempts for ARP (Allocation
readOnly Retention Priority)=13

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each E-RAB with ARP=13 at reception of E-RAB

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 35 of 162

SETUP REQUEST, INITIAL CONTEXT SETUP REQUEST or HANDOVER


REQUEST.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionAttArp14
noNotification
nonPersistent The total number of E-RAB admission attempts for ARP (Allocation
readOnly Retention Priority)=14

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each E-RAB with ARP=14 at reception of E-RAB


SETUP REQUEST, INITIAL CONTEXT SETUP REQUEST or HANDOVER
REQUEST.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionAttArp15
noNotification
nonPersistent The total number of E-RAB admission attempts for ARP (Allocation
readOnly Retention Priority)=15

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each E-RAB with ARP=15 at reception of E-RAB


SETUP REQUEST, INITIAL CONTEXT SETUP REQUEST or HANDOVER
REQUEST.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionAttArp2
noNotification
nonPersistent The total number of E-RAB admission attempts for ARP (Allocation
readOnly Retention Priority)=2

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each E-RAB with ARP=2 at reception of E-RAB


SETUP REQUEST, INITIAL CONTEXT SETUP REQUEST or HANDOVER
REQUEST.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionAttArp3
noNotification
nonPersistent The total number of E-RAB admission attempts for ARP (Allocation
readOnly Retention Priority)=3

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each E-RAB with ARP=3 at reception of E-RAB


SETUP REQUEST, INITIAL CONTEXT SETUP REQUEST or HANDOVER
REQUEST.
Counter type: PEG

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 36 of 162

Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionAttArp4
noNotification
nonPersistent The total number of E-RAB admission attempts for ARP (Allocation
readOnly Retention Priority)=4

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each E-RAB with ARP=4 at reception of E-RAB


SETUP REQUEST, INITIAL CONTEXT SETUP REQUEST or HANDOVER
REQUEST.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionAttArp5
noNotification
nonPersistent The total number of E-RAB admission attempts for ARP (Allocation
readOnly Retention Priority)=5

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each E-RAB with ARP=5 at reception of E-RAB


SETUP REQUEST, INITIAL CONTEXT SETUP REQUEST or HANDOVER
REQUEST.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionAttArp6
noNotification
nonPersistent The total number of E-RAB admission attempts for ARP (Allocation
readOnly Retention Priority)=6

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each E-RAB with ARP=6 at reception of E-RAB


SETUP REQUEST, INITIAL CONTEXT SETUP REQUEST or HANDOVER
REQUEST.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionAttArp7
noNotification
nonPersistent The total number of E-RAB admission attempts for ARP (Allocation
readOnly Retention Priority)=7

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each E-RAB with ARP=7 at reception of E-RAB


SETUP REQUEST, INITIAL CONTEXT SETUP REQUEST or HANDOVER
REQUEST.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 37 of 162

long pmErabAdmissionAttArp8
noNotification
nonPersistent The total number of E-RAB admission attempts for ARP (Allocation
readOnly Retention Priority)=8

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each E-RAB with ARP=8 at reception of E-RAB


SETUP REQUEST, INITIAL CONTEXT SETUP REQUEST or HANDOVER
REQUEST.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionAttArp9
noNotification
nonPersistent The total number of E-RAB admission attempts for ARP (Allocation
readOnly Retention Priority)=9

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each E-RAB with ARP=9 at reception of E-RAB


SETUP REQUEST, INITIAL CONTEXT SETUP REQUEST or HANDOVER
REQUEST.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionSuccArp0
noNotification
nonPersistent The total number of admitted E-RAB Establishment for ARP (Allocation
readOnly Retention Priority)=0

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each admitted E-RAB with ARP=0 at transmission of


E-RAB SETUP RESPONSE, INITIAL CONTEXT SETUP RESPONSE or
HANDOVER REQUEST ACKNOWLEDGE .
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionSuccArp1
noNotification
nonPersistent The total number of admitted E-RAB Establishment for ARP (Allocation
readOnly Retention Priority)=1

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each admitted E-RAB with ARP=1 at transmission of


E-RAB SETUP RESPONSE, INITIAL CONTEXT SETUP RESPONSE or
HANDOVER REQUEST ACKNOWLEDGE .
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionSuccArp10
noNotification

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 38 of 162

nonPersistent The total number of admitted E-RAB Establishment for ARP (Allocation
readOnly
Retention Priority)=10

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each admitted E-RAB with ARP=10 at transmission


of E-RAB SETUP RESPONSE, INITIAL CONTEXT SETUP RESPONSE or
HANDOVER REQUEST ACKNOWLEDGE .
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionSuccArp11
noNotification
nonPersistent The total number of admitted E-RAB Establishment for ARP (Allocation
readOnly Retention Priority)=11

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each admitted E-RAB with ARP=11 at transmission


of E-RAB SETUP RESPONSE, INITIAL CONTEXT SETUP RESPONSE or
HANDOVER REQUEST ACKNOWLEDGE .
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionSuccArp12
noNotification
nonPersistent The total number of admitted E-RAB Establishment for ARP (Allocation
readOnly Retention Priority)=12

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each admitted E-RAB with ARP=12 at transmission


of E-RAB SETUP RESPONSE, INITIAL CONTEXT SETUP RESPONSE or
HANDOVER REQUEST ACKNOWLEDGE .
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionSuccArp13
noNotification
nonPersistent The total number of admitted E-RAB Establishment for ARP (Allocation
readOnly Retention Priority)=13

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each admitted E-RAB with ARP=13 at transmission


of E-RAB SETUP RESPONSE, INITIAL CONTEXT SETUP RESPONSE or
HANDOVER REQUEST ACKNOWLEDGE .
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionSuccArp14
noNotification
nonPersistent The total number of admitted E-RAB Establishment for ARP (Allocation
readOnly Retention Priority)=14

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 39 of 162

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each admitted E-RAB with ARP=14 at transmission


of E-RAB SETUP RESPONSE, INITIAL CONTEXT SETUP RESPONSE or
HANDOVER REQUEST ACKNOWLEDGE .
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionSuccArp15
noNotification
nonPersistent The total number of admitted E-RAB Establishment for ARP (Allocation
readOnly Retention Priority)=15

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each admitted E-RAB with ARP=15 at transmission


of E-RAB SETUP RESPONSE, INITIAL CONTEXT SETUP RESPONSE or
HANDOVER REQUEST ACKNOWLEDGE .
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionSuccArp2
noNotification
nonPersistent The total number of admitted E-RAB Establishment for ARP (Allocation
readOnly Retention Priority)=2

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each admitted E-RAB with ARP=2 at transmission of


E-RAB SETUP RESPONSE, INITIAL CONTEXT SETUP RESPONSE or
HANDOVER REQUEST ACKNOWLEDGE .
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionSuccArp3
noNotification
nonPersistent The total number of admitted E-RAB Establishment for ARP (Allocation
readOnly Retention Priority)=3

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each admitted E-RAB with ARP=3 at transmission of


E-RAB SETUP RESPONSE, INITIAL CONTEXT SETUP RESPONSE or
HANDOVER REQUEST ACKNOWLEDGE .
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionSuccArp4
noNotification
nonPersistent The total number of admitted E-RAB Establishment for ARP (Allocation
readOnly Retention Priority)=4

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 40 of 162

Condition: Stepped for each admitted E-RAB with ARP=4 at transmission of


E-RAB SETUP RESPONSE, INITIAL CONTEXT SETUP RESPONSE or
HANDOVER REQUEST ACKNOWLEDGE .
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionSuccArp5
noNotification
nonPersistent The total number of admitted E-RAB Establishment for ARP (Allocation
readOnly Retention Priority)=5

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each admitted E-RAB with ARP=5 at transmission of


E-RAB SETUP RESPONSE, INITIAL CONTEXT SETUP RESPONSE or
HANDOVER REQUEST ACKNOWLEDGE .
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionSuccArp6
noNotification
nonPersistent The total number of admitted E-RAB Establishment for ARP (Allocation
readOnly Retention Priority)=6

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each admitted E-RAB with ARP=6 at transmission of


E-RAB SETUP RESPONSE, INITIAL CONTEXT SETUP RESPONSE or
HANDOVER REQUEST ACKNOWLEDGE .
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionSuccArp7
noNotification
nonPersistent The total number of admitted E-RAB Establishment for ARP (Allocation
readOnly Retention Priority)=7

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each admitted E-RAB with ARP=7 at transmission of


E-RAB SETUP RESPONSE, INITIAL CONTEXT SETUP RESPONSE or
HANDOVER REQUEST ACKNOWLEDGE .
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionSuccArp8
noNotification
nonPersistent The total number of admitted E-RAB Establishment for ARP (Allocation
readOnly Retention Priority)=8

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each admitted E-RAB with ARP=8 at transmission of


E-RAB SETUP RESPONSE, INITIAL CONTEXT SETUP RESPONSE or
HANDOVER REQUEST ACKNOWLEDGE .

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 41 of 162

Counter type: PEG


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabAdmissionSuccArp9
noNotification
nonPersistent The total number of admitted E-RAB Establishment for ARP (Allocation
readOnly Retention Priority)=9

Deprecated: Since L11B. Has no functional behavior, planned to be


removed.

Condition: Stepped for each admitted E-RAB with ARP=9 at transmission of


E-RAB SETUP RESPONSE, INITIAL CONTEXT SETUP RESPONSE or
HANDOVER REQUEST ACKNOWLEDGE .
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabEstabAttAdded
noNotification
nonPersistent The total number of added E-RAB Establishment attempts. Added E-RABs
readOnly are all E-RABs present in S1 message E-RAB Setup Request.

Condition: Stepped for each bearer received in the S1 message E-RAB


Setup Request.
Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..16] pmErabEstabAttAddedArp
nonUnique
noNotification The total number of added E-RAB Establishment attempts per ARP value.
nonPersistent Added E-RABs are all E-RABs present in S1 message E-RAB Setup Request.
readOnly
[0]: N/A (unallowed ARP value)
[1]: Sum of added E-RAB Establish Attempts with ARP priority value 1
...
[15]: Sum of added E-RAB Establish Attempts with ARP priority value 15

Condition: Stepped at reception of E-RAB Setup Request for each E-RAB


that has the given ARP Priority Level.
Counter type: PDF
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmErabEstabAttAddedPa
noNotification
nonPersistent The total number of added E-RAB Establishment attempts with Privileged
readOnly Access. Added E-RABs are all E-RABs present in S1 message E-RAB Setup
Request.

Condition: Stepped at reception of E-RAB Setup Request for each E-RAB


that have the given ARP Priority Level equal to or below
AdmissionControl::paArpOverride.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmErabEstabAttAddedQci
nonUnique
noNotification The total number of additional E-RAB setup attempts per QCI.
nonPersistent
readOnly Compressed: True

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 42 of 162

Condition: Shall be stepped for each E-RAB Establishment attempt per QCI
at reception of S1-AP message E-RAB Setup Request.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabEstabAttGbr
noNotification
nonPersistent The total number of E-RAB setup attempts with resource type GBR for a
readOnly cell.

Deprecated: Since L11B. Planned to be removed.

Condition: Shall be stepped for each E-RAB Establishment attempt with


resource type GBR.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmErabEstabAttInit
noNotification
nonPersistent The total number of initial E-RAB Establishment attempts. Initial E-RABs are
readOnly all E-RABs present in the S1 message Initial Context Setup Request.

Condition: Stepped for each E-RAB received in the S1 message Initial


Context Setup Request.
Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..16] pmErabEstabAttInitArp
nonUnique
noNotification The total number of initial E-RAB Establishment attempts per ARP value.
nonPersistent Initial E-RABs are all E-RABs present in the S1 message Initial Context
readOnly Setup Request.

[0]: N/A (unallowed ARP value)


[1]: Sum of initial E-RAB Establish Attempts with ARP priority value 1
...
[15]: Sum of initial E-RAB Establish Attempts with ARP priority value 15

Condition: Stepped at reception of Initial Context Setup Request for each


E-RAB that has the given ARP Priority Level.
Counter type: PDF
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmErabEstabAttInitPa
noNotification
nonPersistent The total number of initial E-RAB Establishment attempts with Privileged
readOnly Access. Initial E-RABs are all E-RABs present in the S1 message Initial
Context Setup Request.

Condition: Stepped at reception of Initial Context Setup Request for each


E-RAB that have the given ARP Priority Level equal to or below
AdmissionControl::paArpOverride.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmErabEstabAttInitQci
nonUnique
noNotification

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 43 of 162

nonPersistent The total number of initial E-RAB setup attempts per QCI.
readOnly

Compressed: True

Condition: Shall be stepped for each E-RAB Establishment attempt per QCI
at reception of S1-AP message Initial Context Setup Request.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabEstabFailAddedLic
noNotification
nonPersistent The total number of failed establishment of added E-RABs due to license
readOnly rejects (Multiple Radio Bearer per user or RLC UM). Added E-RABs are all
E-RABs present in S1 message E-RAB Setup Request.

Condition: Stepped for each added E-RAB that fails to be established due to
a license reject (Multiple Radio Bearer per user or RLC UM). The specific
license will be indicated in the PM event triggered by this counter.

Counter type: PEG


Scanner: Primary
Counter is reset after measurement period: Yes
long pmErabEstabFailGbrDlCell
noNotification
nonPersistent The total number of failed E-RAB setup attempts due to downlink GBR
readOnly overload for a cell.

Deprecated: Since L11B. Planned to be removed.

Condition: Shall be stepped for each failed E-RAB Establishment attempt


due to downlink GBR overload for cell-level resources.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmErabEstabFailGbrDlEnb
noNotification
nonPersistent The total number of failed E-RAB setup attempts due to downlink GBR
readOnly overload for resources common to the eNodeB.

Condition: Shall be stepped for each failed E-RAB Establishment attempt


due to downlink GBR overload for resources common to the eNodeB.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmErabEstabFailGbrUlCell
noNotification
nonPersistent The total number of failed E-RAB setup attempts due to uplink GBR
readOnly overload for a cell.

Deprecated: Since L11B. Planned to be removed.

Condition: Shall be stepped for each failed E-RAB Establishment attempt


due to uplink GBR overload for cell-level resources.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 44 of 162

long pmErabEstabFailGbrUlEnb
noNotification
nonPersistent The total number of failed E-RAB setup attempts due to uplink GBR
readOnly overload for resources common to the eNodeB.

Condition: Shall be stepped for each failed E-RAB Establishment attempt


due to uplink GBR overload for resources common to the eNodeB.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmErabEstabFailInitLic
noNotification
nonPersistent The total number of failed establishment of initial E-RABs due to license
readOnly rejects (Multiple Radio Bearer per user or RLC UM). Initial E-RABs are all
E-RABs present in the S1 message Initial Context Setup Request.

Condition: Stepped for each initial E-RAB that fails to be established due to
a license reject (Multiple Radio Bearer per user or RLC UM).The specific
license will be indicated in the PM event triggered by this counter.
Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long pmErabEstabSuccAdded
noNotification
nonPersistent The total number of successfully added E-RABs. Added E-RABs are all
readOnly E-RABs present in S1 message E-RAB Setup Request.

Condition: Stepped for each added bearer that is successfully established.


Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..16] pmErabEstabSuccAddedArp
nonUnique
noNotification The total number of successfully added E-RABs per ARP value. Added
nonPersistent E-RABs are all E-RABs present in S1 message E-RAB Setup Request.
readOnly
[0]: N/A (unallowed ARP value)
[1]: Sum of successful added E-RABs established with ARP priority value 1
...
[15]: Sum of successful added E-RABs established with ARP priority value
15

Condition: Stepped at sending of Initial Context Setup Response for each


successfully setup E-RAB that have the given ARP Priority Level.
Counter type: PDF
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmErabEstabSuccAddedPa
noNotification
nonPersistent The total number of successfully added E-RABs with Privileged Access.
readOnly Added E-RABs are all E-RABs present in S1 message E-RAB Setup Request.

Condition: Stepped at sending of E-RAB Setup Response for each


successfully setup E-RAB that have the given ARP Priority Level equal to or
below AdmissionControl::paArpOverride.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmErabEstabSuccAddedQci
nonUnique

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 45 of 162

noNotification The total number of successful additional E-RAB setup per QCI.
nonPersistent
readOnly
Compressed: True

Condition: Shall be stepped for each successful E-RAB Establishment


attempt per QCI at transmission of S1-AP message E-RAB Setup Response.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabEstabSuccGbr
noNotification
nonPersistent The total number of successful E-RAB setup with resource type GBR for a
readOnly cell.

Deprecated: Since L11B. Planned to be removed.

Condition: Shall be stepped for each successful E-RAB Establishment


attempt with resource type GBR.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmErabEstabSuccInit
noNotification
nonPersistent The total number of successful initial E-RAB Establishments. Initial E-RABs
readOnly are all E-RABs present in the S1 message Initial Context Setup Request.

Condition: Stepped for each initial E-RAB that is successfully established.


Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..16] pmErabEstabSuccInitArp
nonUnique
noNotification The total number of successful initial E-RAB Establishments per ARP value.
nonPersistent
readOnly [0]: N/A (unallowed ARP value)
[1]: Sum of successful initial E-RAB Establishment with ARP priority value 1
...
[15]: Sum of successful initial E-RAB Establishment with ARP priority value
15

Condition: Stepped at sending of Initial Context Setup Response for each


successfully setup E-RAB that have the given ARP Priority Level.
Counter type: PDF
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmErabEstabSuccInitPa
noNotification
nonPersistent The total number of successful initial E-RAB Establishments with Privileged
readOnly Access. Initial E-RABs are all E-RABs present in the S1 message Initial
Context Setup Request.

Condition: Stepped at sending of Initial Context Setup Response for each


successfully setup E-RAB that have the given ARP Priority Level equal to or
below AdmissionControl::paArpOverride.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmErabEstabSuccInitQci
nonUnique

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 46 of 162

noNotification The total number of successful initial E-RAB setup per QCI.
nonPersistent
readOnly
Compressed: True

Condition: Shall be stepped for each successful E-RAB Establishment


attempt per QCI at transmission of S1-AP message Initial Context Setup
Response.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmErabLevRopStartQci
nonUnique
noNotification The number of Established ERABs per QCI at the end of the measurement
nonPersistent period.
readOnly
Compressed: True
ROP snapshot: True

Condition: This counter is based on an internal level counter maintained by


eNB. The internal level counter maintains the current number of ERABs per
QCI. pmErabLevRopStartQci is updated with the current value at the
measurement period end.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: No
long pmErabLevSamp
noNotification
nonPersistent Counts the number of times the corresponding Sum counters has been
readOnly incremented.
Associated ACC pmCounter pmErabLevSum.

Condition: The counter is increased at every occasion when the


corresponding sum counter is increased.
Counter type: SCAN
Sampling rate: 5 seconds
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabLevSum
noNotification
nonPersistent Sum of all sample values recorded for Number of simultaneous E-RABs
readOnly
Counter type: ACC
Sampling rate: 5 seconds
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabMax
noNotification
nonPersistent The peak number of simultaneous E-RAB usage.
readOnly
Condition: This counter is set equal to the peak value (high water mark) of
the number of simultaneous E-RABs used at the end of each Recording
Output Period (ROP).
Counter type: GAUGE
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmErabModAttQci
nonUnique
noNotification The number of E-RAB Modify attempts per QCI.
Note: since the QCI itself can be modified, if an E-RAB on QCI x is modified

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 47 of 162

nonPersistent to QCI y, bin [x] would be used (and for subsequent E-RAB Modify
readOnly
attempts, bin [y] would be used).

Compressed: True

Condition: Shall be stepped for each E-RAB modification attempt per QCI at
reception of S1-AP message E-RAB Modify Request.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabModFailLic
noNotification
nonPersistent The number of E-RAB Modify attempts initiated from the MME which failed
readOnly due to license reject.

Condition: Stepped for each E-RAB for which modification failed due to
license reject.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmErabModSuccQci
nonUnique
noNotification The number of successful E-RAB Modify attempts per QCI.
nonPersistent Note: since the QCI itself can be modified, if an E-RAB on QCI x is modified
readOnly to QCI y, bin [x] would be used (and for subsequent E-RAB Modify
attempts, bin [y] would be used).

Compressed: True

Condition: Shall be stepped for each successful E-RAB modification attempt


per QCI at transmission of S1-AP message E-RAB Modify Response.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmErabQciLevSum
nonUnique
noNotification The sum of the number of simultaneous E-RABs per QCI within the
nonPersistent measurement period.
readOnly
Compressed: True

Condition: The bin accumulates the number of simultaneous E-RABs per


QCI.
Counter type: PDF
Sampling rate: 5
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmErabQciMax
nonUnique
noNotification The maximum number of simultaneous E-RABs per QCI among all
nonPersistent measured values within the measurement period.
readOnly
Compressed: True

Condition: The bin represents the max number of simultaneous E-RABs per
QCI among all measured values within the measurement period.
Counter type: PDF
Sampling rate: 5
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 48 of 162

long pmErabRelAbnormalEnb
noNotification
nonPersistent The total number of abnormal E-RAB Releases triggered by eNB per cell.
readOnly
Condition: Stepped at reception of S1 message E-RAB Release Command or
UE Context Release Command where the cause value indicates system
(abnormal) release with the pre-condition that the Initial Context
Establishment procedure must first have been successfully completed. The
release must also have been eNB initiated.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabRelAbnormalEnbAct
noNotification
nonPersistent The total number of abnormal E-RAB Releases per cell initiated by the eNB
readOnly and that there was data in either the UL or DL buffer (i.e. active).

Condition: If there was data in the buffer at the time of release, then
stepped at reception of S1 message E-RAB Release Command or UE
Context Release Command when internal cause codes considered abnormal
(Radio Connection with UE is lost; Handover failure for the UE; Non
admitted E-RABs by target cell at successful handover for the UE; UE pre-
emption) when the RBS initiated the release. It can also be stepped at
transmission of E-RAB Release Indication, UE Context Release Request or
Reset message by the RBS, or when a cell owned by that RBS is disabled
(and that leads to internal RBS UE Context Release). In the UL case when a
UE has multiple bearers co-existing and sharing the same LCG, the bearers
share a single packet queue. If one of the bearers is released and there is
data in the queue, the bearer's associated counter is incremented,
regardless of whether or not the data belongs to the released bearer.
Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..16] pmErabRelAbnormalEnbActArp
nonUnique
noNotification The total number of abnormal E-RAB Releases initiated by the RBS (per cell
nonPersistent per ARP). The counter is stepped if data was present in the UL or DL
readOnly buffers.
Type:
Compressed PDF
[0]: Sum of active E-RABs released with ARP priority value 0
[1]: Sum of active E-RABs released with ARP priority value 1
….
[15]: Sum of active E-RABs released with ARP priority value 15

Compressed: True

Condition: If there was data in the buffer at the time of release, then
stepped at reception of S1 message E-RAB Release Command or UE
Context Release Command, for E-RAB/s with the specific ARP Priority Level,
when internal cause codes considered abnormal (Radio Connection with UE
is lost; Handover failure for the UE; Non admitted E-RABs by target cell at
successful handover for the UE; UE pre-emption; Bearer pre-emption)
when the RBS initiated the release. It can also be stepped at transmission
of Reset message by the RBS, or when a cell owned by that RBS is disabled
(and that leads to internal RBS UE Context Release). In the UL case when a
UE has multiple bearers co-existing and sharing the same LCG, the bearers
share a single packet queue. If one of the bearers is released and there is
data in the queue, the bearer's associated counter is incremented,
regardless of whether or not the data belongs to the released bearer.
Counter type: PDF
Sampling rate: -

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 49 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long pmErabRelAbnormalEnbActCdt
noNotification
nonPersistent The total number of abnormal ERAB releases by the eNB per cell due cell
readOnly down time (manual intervention) with the pre-condition that the Initial
Context Establishment procedure must first have been successfully
completed and that there was data in either the UL or DL buffer (i.e.
active).

Condition: Stepped for each ERAB that is lost due to cell down time
(manual intervention) when data was in either the UL or DL buffer. In the
UL case when a UE has multiple bearers co-existing and sharing the same
LCG, the bearers share a single packet queue. If one of the bearers is
released and there is data in the queue, the bearer's associated counter is
incremented, regardless of whether or not the data belongs to the released
bearer.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabRelAbnormalEnbActHo
noNotification
nonPersistent The total number of abnormal ERAB releases per cell by the eNB due to
readOnly handover execution failure and that there was data in either the UL or DL
buffer (i.e. active).

Condition: If there was data in the buffer at the time of release, and the
release is due to that executed handover fails and the UE is considered
dropped. In the UL case when a UE has multiple bearers co-existing and
sharing the same LCG, the bearers share a single packet queue. If one of
the bearers is released and there is data in the queue, the bearer's
associated counter is incremented, regardless of whether or not the data
belongs to the released bearer.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabRelAbnormalEnbActHpr
noNotification
nonPersistent The total number of abnormal ERAB releases by the eNB per cell due to
readOnly handover preparation and that there was data in either the UL or DL buffer
(i.e. active).

Condition: If there was data in the buffer at the time of release of an


E-RAB, due to that an executed handover excludes the E-RAB (admission
reject in target). In the UL case when a UE has multiple bearers co-existing
and sharing the same LCG, the bearers share a single packet queue. If one
of the bearers is released and there is data in the queue, the bearer's
associated counter is incremented, regardless of whether or not the data
belongs to the released bearer.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabRelAbnormalEnbActPe
noNotification
nonPersistent The total number of abnormal E-RAB releases per cell, initiated by the RBS
readOnly due to UE pre-emption with the pre-condition that the Initial Context
Establishment procedure must first have been successfully completed and
when data was in either the UL or DL buffer (i.e. active).

Condition: Stepped for each ERAB that is released due to pre-emption when
data was in either the UL or DL buffer. In the UL case when a UE has
multiple bearers co-existing and sharing the same LCG, the bearers share a
single packet queue. If one of the bearers is released and there is data in

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 50 of 162

the queue, the bearer's associated counter is incremented, regardless of


whether or not the data belongs to the released bearer.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmErabRelAbnormalEnbActQci
nonUnique
noNotification The total number of active E-RABs released abnormally per cell per QCI for
nonPersistent requests initiated by eNB (per cell per QCI). , except active E-RABs
readOnly released due to successful HO. An E-RAB is considered to be active when
there are data in the DL or UL queues for the E-RAB.

Compressed: True

Condition: The bin is steped for each released active E-RAB that maps to a
certain QCI when the release is triggered by an E-RAB Release Indication,
UE Context Release Request or Reset message and has a internal abnormal
cause code, except active E-RABs released due to a successful HO. In the
UL case when a UE has multiple bearers co-existing and sharing the same
LCG, the bearers share a single packet queue. If one of the bearers is
released and there is data in the queue, the bearer's associated counter is
incremented, regardless of whether or not the data belongs to the released
bearer.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabRelAbnormalEnbActTnFail
noNotification
nonPersistent The total number of abnormal ERAB releases per cell due to S1 interface
readOnly down, "X2 interface down" or "Transport Resource Unavailable", with the
pre-condition that the Initial Context Establishment procedure must first
have been successfully completed and that there was data in either the UL
or DL buffer (i.e. active).

Condition: If there was data in the buffer at the time of release of an E-RAB
and due to that the S1 interface is lost or S1 bearer error indication is
received. In the UL case when a UE has multiple bearers co-existing and
sharing the same LCG, the bearers share a single packet queue. If one of
the bearers is released and there is data in the queue, the bearer's
associated counter is incremented, regardless of whether or not the data
belongs to the released bearer.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabRelAbnormalEnbActUeLost
noNotification
nonPersistent The total number of abnormal ERAB releases by the eNB per cell due that
readOnly the contact with the UE is lost with the pre-condition that the Initial Context
Establishment procedure must first have been successfully completed and
that there was data in either the UL or DL buffer (i.e. active).

Condition: If there was data in the buffer at the time of release and if there
was a release of an UE due to that the radio connection towards the UE is
lost (i.e. UE unreachable by the RBS). In the UL case when a UE has
multiple bearers co-existing and sharing the same LCG, the bearers share a
single packet queue. If one of the bearers is released and there is data in
the queue, the bearer's associated counter is incremented, regardless of
whether or not the data belongs to the released bearer.
Counter type: PEG

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 51 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long[0..16] pmErabRelAbnormalEnbArp
nonUnique
noNotification The total number of abnormal E-RAB Releases initiated by the RBS (per cell
nonPersistent per ARP). The counter is stepped regardless of whether data was or was not
readOnly lost in UL/DL buffers.
Type:
Compressed PDF
[0]: Sum of E-RABs released with ARP priority value 0
[1]: Sum of E-RABs released with ARP priority value 1
….
[15]: Sum of E-RABs released with ARP priority value 15

Compressed: True

Condition: Stepped at reception of S1 message E-RAB Release Command or


UE Context Release Command, with the pre-condition that the Initial
Context Establishment procedure must first have been successfully
completed, for E-RAB/s with the specific ARP Priority Level, when internal
cause codes considered abnormal (Radio Connection with UE is lost;
Handover failure for the UE; Non admitted E-RABs by target cell at
successful handover for the UE; UE pre-emption; Bearer pre-emption)
when the RBS initiated the release. It can also be stepped at transmission
of Reset message by the RBS, or when a cell owned by that RBS is disabled
(and that leads to internal RBS UE Context Release).
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabRelAbnormalEnbLic
noNotification
nonPersistent The total number of abnormal E-RAB Releases initiated by the RBS due to
readOnly license reject (per cell).

Condition: Stepped at reception of S1 message E-RAB Release Command or


UE Context Release Command, with the pre-condition that the Initial
Context Establishment procedure must first have been successfully
completed, when internal cause codes considered abnormal (license Limited
Service Mode Emergency Call Support is not operable) and when the RBS
initiated the release.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabRelAbnormalEnbPe
noNotification
nonPersistent The total number of abnormal E-RAB Releases per cell, initiated by the RBS
readOnly due to UE pre-emption with the pre-condition that the Initial Context
Establishment procedure must first have been successfully completed. The
counter is stepped regardless of whether data was or was not lost in UL/DL
buffers.

Condition: abnormal E-RAB Release due to UE pre-emption


Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmErabRelAbnormalEnbQci
nonUnique
noNotification The total number of E-RABs released abnormally per cell per QCI for
nonPersistent requests initiated by eNB.
readOnly

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 52 of 162

Compressed: True

Condition: The bin is stepped for each released E-RAB that maps to a
certain QCI when the release is triggered by an UE CONTEXT RELEASE
REQUEST message and has an internal abnormal cause code and with the
pre-condition that the Initial Context Establishment procedure must first
have been successfully completed.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabRelAbnormalMmeAct
noNotification
nonPersistent The total number of E-RAB Releases initiated by the MME considered as
readOnly abnormal. The counter is stepped if if there was data in either the UL or DL
buffer (i.e. active).

Condition: Stepped at reception of S1 message E-RAB Release Command or


UE Context Release with none of the causes Normal Release, Handover
Successful, User Inactivity, Detach, CS Fallback Triggered, Inter-RAT
Redirection, UE Not available for PS Service or Redirection towards 1xRTT
and there was data in either the UL or DL buffer (i.e. active). The release
must also have been MME initiated. In the UL case when a UE has multiple
bearers co-existing and sharing the same LCG, the bearers share a single
packet queue. If one of the bearers is released and there is data in the
queue, the bearer's associated counter is incremented, regardless of
whether or not the data belongs to the released bearer.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..16] pmErabRelAbnormalMmeActArp
nonUnique
noNotification The total number of E-RAB Releases initiated by the MME considered as
nonPersistent abnormal per cell per ARP Level. The counter is stepped if there was data in
readOnly either the UL or DL buffer (i.e. active).
Type:
Compressed PDF
[0]: Sum of E-RABs released with ARP priority value 0
[1]: Sum of E-RABs released with ARP priority value 1
….
[15]: Sum of E-RABs released with ARP priority value 15

Compressed: True

Condition: The bin corresponding to the ARP level is stepped at reception of


S1 message E-RAB Release Command or UE Context Release Command
with none of the causes Normal Release, Detach, CS Fallback Triggered or
Redirection towards 1xRTT and there was data in either the UL or DL buffer
(i.e. active). The release must also have been MME initiated. In the UL case
when a UE has multiple bearers co-existing and sharing the same LCG, the
bearers share a single packet queue. If one of the bearers is released and
there is data in the queue, the bearer's associated counter is incremented,
regardless of whether or not the data belongs to the released bearer.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmErabRelAbnormalMmeActQci
nonUnique
noNotification The total number of E-RAB Releases (per cell per QCI) initiated by the MME
considered as abnormal. The counter is stepped if data was lost in either

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 53 of 162

nonPersistent the UL or DL buffers.


readOnly
Type:
Compressed PDF
[0]: N/A
[1]: Abnormal active E-RAB releases for E-RABs with QCI 1
….
[255]: Abnormal active E-RAB releases for E-RABs with QCI 255

Compressed: True

Condition: The bin corresponding to the QCI of the E-RAB is stepped at


reception of S1 message E-RAB Release Command or UE Context Release
with none of the causes Normal Release, Handover Successful, User
Inactivity, Detach, CS Fallback Triggered, Inter-RAT Redirection, UE Not
available for PS Service or Redirection towards 1xRTT and there was data in
either the UL or DL buffer (i.e. active). The release must also have been
MME initiated. In the UL case when a UE has multiple bearers co-existing
and sharing the same LCG, the bearers share a single packet queue. If one
of the bearers is released and there is data in the queue, the bearer's
associated counter is incremented, regardless of whether or not the data
belongs to the released bearer.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabRelMme
noNotification
nonPersistent The total number of E-RAB Releases per cell initiated by the MME excluding
readOnly successful handover. The counter is stepped regardless of whether data
was or was not lost in UL/DL buffers.

Condition: The counter is stepped for each released E-RAB at reception of


S1 message E-RAB Release Command or UE Context Release Command
(except if the cause was successful handover) and with the pre-condition
that the Initial Context Establishment procedure must first have been
successfully completed. The release must also have been MME initiated.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabRelMmeAct
noNotification
nonPersistent The total number of E-RAB Releases initiated by the MME (per cell) and that
readOnly there was data in either the UL or DL buffer (i.e. active).

Condition: If there was data in the buffer at the time of release, then
stepped at reception of S1 message E-RAB Release Command or UE
Context Release Command (except if the cause was successful handover).
The release must also have been MME initiated. In the UL case when a UE
has multiple bearers co-existing and sharing the same LCG, the bearers
share a single packet queue. If one of the bearers is released and there is
data in the queue, the bearer's associated counter is incremented,
regardless of whether or not the data belongs to the released bearer.
Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long pmErabRelMmeActEutra
noNotification
nonPersistent The total number of E-RAB Releases per cell, initiated by the MME with the
readOnly pre-condition that the Initial Context Establishment procedure must first
have been successfully completed and that there was data in either the UL
or DL buffer (i.e. active) and the cause was "Release due to Eutran
generated reason".

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 54 of 162

Condition: Stepped at reception of S1 message E-RAB Release Command or


UE Context Release Command. The release must also have been MME
initiated and cause was "Release due to Eutran generated reason". In the
UL case when a UE has multiple bearers co-existing and sharing the same
LCG, the bearers share a single packet queue. If one of the bearers is
released and there is data in the queue, the bearer's associated counter is
incremented, regardless of whether or not the data belongs to the released
bearer.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmErabRelMmeActQci
nonUnique
noNotification The total number of active E-RABs released per QCI for requests initiated
nonPersistent by MME, except active E-RABs released due to successful HO. An E-RAB is
readOnly considered to be active when there are data in the DL or UL queues for the
E-RAB.

Compressed: True

Condition: The bin is stepped for each released active E-RAB that maps to a
certain QCI when the release is triggered by MME through an E-RAB
RELEASE COMMAND or UE CONTEXT RELEASE COMMAND message, except
active E-RABs released due to a successful HO. In the UL case when a UE
has multiple bearers co-existing and sharing the same LCG, the bearers
share a single packet queue. If one of the bearers is released and there is
data in the queue, the bearer's associated counter is incremented,
regardless of whether or not the data belongs to the released bearer.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabRelMmeActUnspecified
noNotification
nonPersistent The total number of E-RAB Releases per cell, initiated by the MME with the
readOnly pre-condition that the Initial Context Establishment procedure must first
have been successfully completed and that there was data in either the UL
or DL buffer (i.e. active) and the cause was "Unspecified".

Condition: Stepped at reception of S1 message E-RAB Release Command or


UE Context Release Command. The release must also have been MME
initiated and cause was "Unspecified". In the UL case when a UE has
multiple bearers co-existing and sharing the same LCG, the bearers share a
single packet queue. If one of the bearers is released and there is data in
the queue, the bearer's associated counter is incremented, regardless of
whether or not the data belongs to the released bearer.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabRelMmeActUserInactivity
noNotification
nonPersistent The total number of E-RAB Releases per cell, initiated by the MME with the
readOnly pre-condition that the Initial Context Establishment procedure must first
have been successfully completed and that there was data in either the UL
or DL buffer (i.e. active) and the cause was "User Inactivity".

Condition: Stepped at reception of S1 message E-RAB Release Command or


UE Context Release Command. The release must also have been MME
initiated and cause was "User Inactivity". In the UL case when a UE has

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 55 of 162

multiple bearers co-existing and sharing the same LCG, the bearers share a
single packet queue. If one of the bearers is released and there is data in
the queue, the bearer's associated counter is incremented, regardless of
whether or not the data belongs to the released bearer.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..16] pmErabRelMmeArp
nonUnique
noNotification The total number of E-RAB Releases initiated by the MME excluding
nonPersistent successful handover per cell per ARP Level. The counter is stepped
readOnly regardless of whether data was or was not lost in UL/DL buffers.
Type:
Compressed PDF
[0]: Sum of E-RABs released with ARP priority value 0 (unallowed ARP
level)
[1]: Sum of E-RABs released with ARP priority value 1
….
[15]: Sum of E-RABs released with ARP priority value 15

Compressed: True

Condition: Stepped at reception of S1 message E-RAB Release Command or


UE Context Release Command (except if the cause was successful
handover) and with pre-condition that the Initial Context Establishment
procedure must first have been successfully completed. The release must
also have been MME initiated.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmErabRelMmeQci
nonUnique
noNotification The total number of E-RAB Releases (per cell per QCI) initiated by the MME
nonPersistent excluding successful handover. The counter is stepped regardless of
readOnly whether data was or was not lost in UL/DL buffers.

Compressed: True

Condition: The corresponding QCI bin is stepped for each released E-RAB at
reception of S1 message E-RAB Release Command or UE Context Release
Command (except if the cause was successful handover) and with the pre-
condition that the Initial Context Establishment procedure must first have
been successfully completed. The release must also have been MME
initiated.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmErabRelNormalEnb
noNotification
nonPersistent The total number of normal E-RAB Releases triggered by eNB per cell.
readOnly
Condition: Stepped at reception of S1 message E-RAB Release Command or
UE Context Release Command where the cause value indicates normal
release with the pre-condition that the Initial Context Establishment
procedure must first have been successfully completed. The release must
also have been eNB initiated.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 56 of 162

long pmErabRelNormalEnbAct
noNotification
nonPersistent The total number of normal E-RAB Releases per cell initiated by the eNB
readOnly and that there was data in either the UL or DL buffer (i.e. active).

Condition: If there was data in the buffer at the time of release, then
stepped at reception of S1 message E-RAB Release Command or UE
Context Release Command when internal cause codes considered normal
(User Inactivity, Inter-RAT redirection, CS Fallback Triggered) when the
RBS initiated the release. In the UL case when a UE has multiple bearers
co-existing and sharing the same LCG, the bearers share a single packet
queue. If one of the bearers is released and there is data in the queue, the
bearer's associated counter is incremented, regardless of whether or not
the data belongs to the released bearer.
Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..16] pmErabRelNormalEnbActArp
nonUnique
noNotification The total number of normal E-RAB Releases initiated by the RBS (per cell
nonPersistent per ARP). The counter is stepped if there was data lost in UL/DL buffers.
readOnly Type:
Compressed PDF
[0]: Sum of E-RABs released with ARP priority value 0
[1]: Sum of E-RABs released with ARP priority value 1
….
[15]: Sum of E-RABs released with ARP priority value 15

Compressed: True

Condition: If there was data in the buffer at the time of release, then
stepped at reception of S1 message E-RAB Release Command or UE
Context Release Command, for E-RAB/s with the specific ARP Priority Level,
when internal cause codes considered normal and the RBS initiated the
release. In the UL case when a UE has multiple bearers co-existing and
sharing the same LCG, the bearers share a single packet queue. If one of
the bearers is released and there is data in the queue, the bearer's
associated counter is incremented, regardless of whether or not the data
belongs to the released bearer.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmErabRelNormalEnbActQci
nonUnique
noNotification The total number of active E-RABs released normally (per cell per QCI) for
nonPersistent requests initiated by eNB, except active E-RABs released due to successful
readOnly HO. An E-RAB is considered to be active when there are data in the DL or
UL queues for the E-RAB.

Compressed: True

Condition: The bin is stepped for each released active E-RAB that maps to a
certain QCI when the release is triggered by an UE CONTEXT RELEASE
REQUEST message and has a normal release cause code, except active
E-RABs released due to a successful HO. In the UL case when a UE has
multiple bearers co-existing and sharing the same LCG, the bearers share a
single packet queue. If one of the bearers is released and there is data in
the queue, the bearer's associated counter is incremented, regardless of
whether or not the data belongs to the released bearer.
Counter type: PDF
Sampling rate: -

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 57 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long[0..16] pmErabRelNormalEnbArp
nonUnique
noNotification The total number of normal E-RAB Releases initiated by the RBS.
nonPersistent Type:
readOnly Compressed PDF
[0]: [0]: N/A (unallowed ARP value)
[1]: Sum of E-RABs released with ARP priority value 1
....
[15]: Sum of E-RABs released with ARP priority value 15

Compressed: True

Condition: Stepped at reception of S1 message E-RAB Release Command or


UE Context Release Command, for E-RAB/s with the specific ARP Priority
Level, when internal cause codes considered normal and the RBS initiated
the release and with the pre-condition that the Initial Context
Establishment procedure must first have been successfully completed.
Counter type: PDF
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..256] pmErabRelNormalEnbQci
nonUnique
noNotification The total number of E-RABs released normally (per cell per QCI) for
nonPersistent requests initiated by eNB.
readOnly
Compressed: True

Condition: The bin is stepped for each released E-RAB that maps to a
certain QCI when the release is triggered by an UE CONTEXT RELEASE
REQUEST message and has an internal normal cause code and with the
pre-condition that the Initial Context Establishment procedure must first
have been successfully completed.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmHoExeAttQci
nonUnique
noNotification The number of handover execution attempt for ERABs per QCI towards
nonPersistent target cell.
readOnly
Compressed: True

Deprecated: Since L12B. Has no functional behaviour. Planned to be


removed.

Condition: RRC CONNCECTION RECONFIGURATION including the


mobilityControlInformation is sent to the UE from the source cell.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmHoExeOutAttQci
nonUnique
noNotification The number of handover execution attempt for ERABs per QCI towards
nonPersistent target cell.
readOnly
Compressed: True

Condition: RRC CONNCECTION RECONFIGURATION including the

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 58 of 162

mobilityControlInformation is sent to the UE from the source cell.


Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmHoExeOutSuccQci
nonUnique
noNotification The number of ERABs per QCI that was succesfully handovered to the
nonPersistent target cell.
readOnly
Compressed: True

Condition: UE CONTEXT RELEASE COMMAND received in the source eNodeB


from the MME with the cause Handover Triggered (S1 handover)
or
UE CONTEXT RELEASE received in the source eNodeB from the target
eNodeB (X2 handover)
or
Internal eNodeB trigger (corresponding to UE CONTEXT RELEASE) received
when the UE has changed cell during a intra eNodeB handover

Counter type: PDF


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmHoExeSuccQci
nonUnique
noNotification The number of ERABs per QCI that was succesfully handovered to the
nonPersistent target cell.
readOnly
Compressed: True

Deprecated: Since L12B. Has no functional behaviour. Planned to be


removed.

Condition: UE CONTEXT RELEASE COMMAND received in the source eNodeB


from the MME with the cause Handover Triggered (S1 handover)
or
UE CONTEXT RELEASE received in the source eNodeB from the target
eNodeB (X2 handover)
or
Internal eNodeB trigger (corresponding to UE CONTEXT RELEASE) received
when the UE has changed cell during a intra eNodeB handover

Counter type: PDF


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmHoPrepRejInBearerAdmissionRej
noNotification
nonPersistent The number of Incoming Handover Preparation Failure messages sent by
readOnly the target eNB due to the fact that all the UE's bearers are rejected during
bearer admission.

Condition: Stepped for each UE that is rejected within an incoming


handover preparation due to the fact that the all the UE's bearers are
rejected during bearer admission.
Counter type: PEG
Sampling rate: -

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 59 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long pmHoPrepRejInHighLoad
noNotification
nonPersistent The number of Handover Preparation Failure messages sent by the target
readOnly eNB due to high load.

Condition: Handover preparation fail due to Load Control function in the


RBS indicates that the load is too high.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmHoPrepRejInLicConnUsers
noNotification
nonPersistent The number of Handover Preparation Failure messages sent by the target
readOnly eNB due to license for connected users being exceeded.

Condition: Handover preparation fail due to license for connected users


being exceeded.
Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long pmHoPrepRejInLicMob
noNotification
nonPersistent The number of Incoming Handover Preparation Failure messages sent by
readOnly the target eNB due to lack of license for handover.

Condition: Handover preparation fail due to the serviceState value is


INOPERABLE for the optional feature, "Intra LTE inter frequency handover"
in the target eNB.
Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long pmHoPrepRejInLicMultiErab
noNotification
nonPersistent The number of non-admitted E-RABs at an incoming handover preparation
readOnly procedure, due to license for Multiple E-RAB being exceeded.

Condition: At transmission by the target eNodeB of the Handover Request


Acknowledge message to the MME or to the source eNodeB.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmHoPrepRejInLicRlcUm
noNotification
nonPersistent The number of non-admitted E-RABs at an incoming handover preparation
readOnly procedure, due to lack of license for RLC UM.

Condition: At transmission by the target eNB of the Handover Request


Acknowledge message to the MME or to the source eNB
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmHoPrepRejInOverload
noNotification
nonPersistent The number of Handover Preparation Failure messages sent by the target
readOnly eNB due to overload.

Condition: Handover preparation fail due to Load Control function in the


RBS indicates overload.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 60 of 162

Counter type: PEG


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmLbSubRatioSamp
noNotification
nonPersistent The number of load balancing cycles during the ROP. This together with the
readOnly counter pmAvSubRatioSum can be used to calculate an average
subscription ratio.

Unit: 1 Number of samples


Condition: Stepped once at every EAB cell resource status report period.
Counter type: SCAN
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmLbSubRatioSum
noNotification
nonPersistent Records the subscription ratio as the result of the traffic load assessment at
readOnly every load balancing cycle. Those values are accumulated each ROP,
allowing the average subscription ratio to be presented for each period.

Unit: 1/1000 subscriptio ratio


Condition: Accumulated at every EAB cell resource status report period. The
current load based on the subscription ratio is the accumulated value to be
used.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..4] pmLcgThpTimeUlLcg
nonUnique
noNotification The UL transmission time used for UL DRB Throughput per LCG. It
nonPersistent comprises of time periods from when the 5th data transmission is received
readOnly on Uu until the second last data transmission is received.

Unit: 1 ms

Condition: The bin accumulates the UL transmission time per LCG for large
data bursts that need to be transmitted across multiple TTIs.
Counter type: PDF
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..4] pmLcgThpVolUlLcg
nonUnique
noNotification The UL volume used for UL DRB Throughput per LCG. It comprises of the
nonPersistent MAC SDU volume received on Uu per LCG, excluding the volume received in
readOnly the first 4 data transmissions and the data transmission emptying the UL
buffer.

Unit: 1 kilobit (1000 bits)

Condition: The bin accumulates the UL volume per LCG for large data
bursts that needs to be transmitted across multiple TTIs.
Counter type: PDF
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmMacDelayTimeDl
noNotification

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 61 of 162

nonPersistent Aggregated time for the downlink MAC delay measure. The time for each
readOnly
sample shall show the time between reception from RLC until it is
successfully received in the UE or HARQ failure occurs.

Unit: 1 ms
Condition: Continuous measurement for UEs aggregated to cell level.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMacHarqDlAck
noNotification
nonPersistent The total number of successful HARQ transmissions (ACKs) in the downlink
readOnly direction.

Deprecated: Since L10B. Has no functional behaviour.

Condition: Continuous measurement for UEs aggregated to cell level.


Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMacHarqDlAck16qam
noNotification
nonPersistent The total number of successful HARQ transmissions in the downlink
readOnly direction using a 16QAM modulation.

Condition: To decide if it was successful is based on the HARQ ACK from


the UE.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMacHarqDlAck64qam
noNotification
nonPersistent The total number of successful HARQ transmissions in the downlink
readOnly direction using a 64QAM modulation.

Condition: To decide if it was successful is based on the HARQ ACK from


the UE.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMacHarqDlAckQpsk
noNotification
nonPersistent The total number of successful HARQ transmissions in the downlink
readOnly direction using a QPSK modulation.

Condition: To decide if it was successful is based on the HARQ ACK from


the UE.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMacHarqDlDtx
noNotification

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 62 of 162

nonPersistent The total number of occasions when an downlink HARQ feedback was not
readOnly
received from an UE and DTX is considered the reason.

Deprecated: Since L10B. Has no functional behaviour.

Condition: Continuous measurement for UEs aggregated to cell level.


Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMacHarqDlDtx16qam
noNotification
nonPersistent The total number of occasions when an downlink HARQ feedback for a
readOnly transport block using 16QAM modulation was not received from an UE and
DTX is considered the reason.

Condition: To decide if it was DTX is based on not receiving any HARQ


feedback on a transport block sent using 16QAM modulation.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMacHarqDlDtx64qam
noNotification
nonPersistent The total number of occasions when an downlink HARQ feedback for a
readOnly transport block using 64QAM modulation was not received from an UE and
DTX is considered the reason.

Condition: To decide if it was DTX is based on not receiving any HARQ


feedback on a transport block sent using 64QAM modulation.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMacHarqDlDtxQpsk
noNotification
nonPersistent The total number of occasions when an downlink HARQ feedback for a
readOnly transport block using QPSK modulation was not received from an UE and
DTX is considered the reason.

Condition: To decide if it was DTX is based on not receiving any HARQ


feedback on a transport block sent using QPSK modulation.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMacHarqDlNack
noNotification
nonPersistent The total number of unsuccessful HARQ transmissions (NACKs) in the
readOnly downlink direction.

Deprecated: Since L10B. Has no functional behaviour.

Condition: Continuous measurement for UEs aggregated to cell level.


Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 63 of 162

long pmMacHarqDlNack16qam
noNotification
nonPersistent The total number of unsuccessful HARQ transmissions in the downlink
readOnly direction using a 16QAM modulation.

Condition: To decide if it was failed is based on the HARQ NACK from the
UE.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMacHarqDlNack64qam
noNotification
nonPersistent The total number of unsuccessful HARQ transmissions in the downlink
readOnly direction using a 64QAM modulation.

Condition: To decide if it was failed is based on the HARQ NACK from the
UE.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMacHarqDlNackQpsk
noNotification
nonPersistent The total number of unsuccessful HARQ transmissions in the downlink
readOnly direction using a QPSK modulation.

Condition: To decide if it was failed is based on the HARQ NACK from the
UE.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMacHarqUlAck
noNotification
nonPersistent The total number of successful HARQ transmissions (ACKs) in the uplink
readOnly direction.

Deprecated: Since L10B. Has no functional behaviour.

Condition: Continuous measurement for UEs aggregated to cell level.


Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMacHarqUlDtx
noNotification
nonPersistent The total number of occasions when an uplink grant was meant for HARQ
readOnly transmission in the uplink direction, where DTX is considered the reason for
no receiption of HARQ in uplink in the eNB.

Deprecated: Since L10B. Has no functional behaviour.

Condition: Continuous measurement for UEs aggregated to cell level.


Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 64 of 162

long pmMacHarqUlDtx16qam
noNotification
nonPersistent The total number of occasions when an uplink grant was meant for HARQ
readOnly transmission of a transport block using 16QAM modulation in the uplink
direction, where DTX is considered the reason for no receiption of HARQ in
uplink in the eNB.

Condition: To decide if it was DTX is based on not receiving a granted


uplink transmission using 16QAM modulation.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMacHarqUlDtxQpsk
noNotification
nonPersistent The total number of occasions when an uplink grant was meant for HARQ
readOnly transmission of a transport block using QPSK modulation in the uplink
direction, where DTX is considered the reason for no receiption of HARQ in
uplink in the eNB.

Condition: To decide if it was DTX is based on not receiving a granted


uplink transmission using QPSK modulation.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMacHarqUlFail16qam
noNotification
nonPersistent The total number of unsuccessful HARQ transmissions in the uplink
readOnly direction using a 16QAM modulation.

Condition: To decide if it was failed is based on the CRC check for recieved
transport blocks (which results in NACK).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMacHarqUlFailQpsk
noNotification
nonPersistent The total number of unsuccessful HARQ transmissions in the uplink
readOnly direction using a QPSK modulation.

Condition: To decide if it was failed is based on the CRC check for recieved
transport blocks (which results in NACK).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMacHarqUlNack
noNotification
nonPersistent The total number of unsuccessful HARQ transmissions (NACKs) in the uplink
readOnly direction.

Deprecated: Since L10B. Has no functional behaviour.

Condition: Continuous measurement for UEs aggregated to cell level.


Counter type: ACC
Sampling rate: -

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 65 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long pmMacHarqUlSucc16qam
noNotification
nonPersistent The total number of successful HARQ transmissions in the uplink direction
readOnly using a 16QAM modulation.

Condition: To decide if it was successful is based on the CRC check, not


based on if RBS sends HARQ ACK (RBS can use the ACK even if the
transport block was not succesfully decoded in a way to control the HARQ).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMacHarqUlSuccQpsk
noNotification
nonPersistent The total number of successful HARQ transmissions in the uplink direction
readOnly using a QPSK modulation.

Condition: To decide if it was successful is based on the CRC check, not


based on if RBS sends HARQ ACK (RBS can use the ACK even if the
transport block was not succesfully decoded in a way to control the HARQ).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmMeasMissingNeighRel
noNotification
nonPersistent This counter is being stepped when a best cell evaluation is received in eNB
readOnly from UE on a PCI where the CGI is unknown, i.e. no neighbour relation to
the cell is available in the eNB.

Condition: This counter is being stepped when a best cell evaluation is


received in eNB from UE on a PCI where the CGI is unknown, i.e. no
neighbour relation to the cell is available in the eNB.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPagDiscarded
noNotification
nonPersistent This counter counts the number of S1AP Paging messages discarded and
readOnly not broadcasted in this cell. This counter is a subset of pmPagReceived.

Condition: When the cell fails to broadcast an RRC Paging within a certain
time (pagingDiscardTimer), e.g. due to congestion, the Paging is discarded
and this counter is incremented by the number of included Paging Records
in the discarded Paging message.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPagReceived
noNotification
nonPersistent This counter counts the number of S1AP Paging messages routed to this
readOnly cell.

Condition: When an S1AP Paging is routed to this cell which is correct and
complete. An S1AP Paging message discarded as part of pmPagS1Discarded
will not cause this counter to be pegged.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 66 of 162

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcchCceActivity
noNotification
nonPersistent Counter of how often the PDCCH has 1 or more CCEs used. To re-normalize
readOnly pmPdcchCceUtil for subframes containing traffic, use this counter compute
and remove idle subframes.

Condition: Pegs when 1 or more CCEs utilized in a subframe.


Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmPdcchCceUsedDlQci
nonUnique
noNotification The total number of CCEs used for DL grants per QCI.
nonPersistent Compressed: True
readOnly
Condition: The bin accumulates the number of CCEs used for DL grants
corresponding to TBs with bits belonging to a specific QCI.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmPdcchCceUsedUlQci
nonUnique
noNotification The total number of CCEs used for UL grants per QCI. When a single UE is
nonPersistent associated with multiple QCIs, only QCI that has highest priority ( logical
readOnly group with highest priority) contribute to the CCE count.
Compressed: True

Condition: The bin accumulates the number of CCEs used for UL grants
corresponding to TBs with bits belonging to a specific QCI.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..20] pmPdcchCceUtil
nonUnique
noNotification PDF of % of CCEs utilized compared with total CCEs available (at the
nonPersistent maximum CFI permitted by pdcchCfiMode) each subframe, considering
readOnly bandwidth and antenna configuration.
[0]: utilization <= 5%
[1]: 5% < utilization <= 10%
[2]: 10% < utilization <= 15%
[3]: 15% < utilization <= 20%
[4]: 20% < utilization <= 25%
[5]: 25% < utilization <= 30%
[6]: 30% < utilization <= 35%
[7]: 35% < utilization <= 40%
[8]: 40% < utilization <= 45%
[9]: 45% < utilization <= 50%
[10]: 50% < utilization <= 55%
[11]: 55% < utilization <= 60%
[12]: 60% < utilization <= 65%
[13]: 65% < utilization <= 70%
[14]: 70% < utilization <= 75%
[15]: 75% < utilization <= 80%
[16]: 80% < utilization <= 85%
[17]: 85% < utilization <= 90%
[18]: 90% < utilization <= 95%
[19]: 95% < utilization <= 100%

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 67 of 162

Condition: Appropriate bin is incremented every radio subframe.


Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..3] pmPdcchCfiUtil
nonUnique
noNotification PDF of number of subframes each CFI value was assigned
nonPersistent [0]: CFI = 1
readOnly [1]: CFI = 2
[2]: CFI = 3

Condition: Appropriate bin is incremented every radio subframe.


Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcchMaxCceAvail
noNotification
nonPersistent The total maximum number of CCEs available determined based on the
readOnly bandwidth and antenna configuration.

Condition: The counter accumulates the maximum number of CCEs


available.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..20] pmPdcchResUtil
nonUnique
noNotification PDCCH resource utilization distribution.
nonPersistent
readOnly PDF ranges:
[0]: [0..5]%,
[1]: ]5..10]%,
[2]: ]10..15]%,
[3]: ]15..20]%,
[4]: ]20..25]%,
[5]: ]25..30]%,
[6]: ]30..35]%,
[7]: ]35..40]%,
[8]: ]40..45]%,
[9]: ]45..50]%,
[10]: ]50..55]%,
[11]: ]55..60]%,
[12]: ]60..65]%,
[13]: ]65..70]%,
[14]: ]70..75]%,
[15]: ]75..80]%,
[16]: ]80..85]%,
[17]: ]85..90]%,
[18]: ]90..95]%,
[19]: ]95..100]%

Unit: 1 %

Deprecated: Since L12A. Replaced by pmPdcchCceUtil. Planned to be


removed.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 68 of 162

Condition: The PDF shall be updated each TTI with the percentage of
PDCCH resources used.
Counter type: PDF
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcchResyncAtt
noNotification
nonPersistent The total number of attempted 3GPP procedure "PDCCH ordered
readOnly resynchronization", see 3GPP TS 36.321 and TS 36.212.

Condition: The counter is increased when a pdcch ordered re-


synchronization is sent in downlink.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcchResyncSucc
noNotification
nonPersistent The total number of successful 3GPP procedures "PDCCH ordered
readOnly resynchronization", see 3GPP TS 36.321 and TS 36.212.

Condition: The counter contains both successful Contention Based Random


Access (CBRA) and Contention Free Random Access (CFRA). The counter is
stepped each time a raMsg3 is received from a UE which was outOfSynch
prior to the RACH and had triggered UL resynchronization over PDCCH.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcchTxAggressive
noNotification
nonPersistent The total number of aggressive unicast PDCCH transmissions.
readOnly
Condition: It is pegged if a unicast PDCCH transmission (excluding that for
message 2 or 3) is aggressive (the number of allocated CCEs is less than
the number of required CCEs).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcchTxConservative
noNotification
nonPersistent The total number of conservative unicast PDCCH transmissions.
readOnly
Condition: It is pegged if a unicast PDCCH transmission (excluding that for
message 2 or 3) is conservative (the number of allocated CCEs is much
more than the number of required CCEs).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpBitrateDlDrbMax
noNotification
nonPersistent Peak cell DL bit rate. One cell bit rate sample is obtained by dividing the
readOnly total volume (PDCP SDU) on Data Radio Bearers aggregated to cell level,
that has been transmitted in the downlink direction in the PDCP layer, with
the time (in seconds) of the sample gathering period.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total volume (PDCP SDU) is measured on PCell.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 69 of 162

Unit: 1 kbps
Filter: FDD
Condition: The counter is set equal to the peak sample at the end of each
Recording Output Period (ROP).
Counter type: GAUGE
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpBitrateDlDrbMin
noNotification
nonPersistent Minimum cell DL bit rate. One cell bit rate sample is obtained by dividing
readOnly the total volume (PDCP SDU) on Data Radio Bearers aggregated to cell
level, that has been transmitted in the downlink direction in the PDCP layer,
with the time (in seconds) of the sample gathering period.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total volume (PDCP SDU) is measured on PCell.

Unit: 1 kbps
Filter: FDD
Condition: The counter is set equal to the low mark sample at the end of
each Recording Output Period (ROP).
Counter type: GAUGE
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpBitrateUlDrbMax
noNotification
nonPersistent Peak cell UL bit rate. One cell bit rate sample is obtained by dividing the
readOnly total volume (PDCP SDU) on Data Radio Bearers aggregated to cell level,
that has been received in the uplink direction, with the time (in seconds) of
the sample gathering period.

Unit: 1 kbps
Condition: The counter is set equal to the peak sample at the end of each
Recording Output Period (ROP).
Counter type: GAUGE
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpBitrateUlDrbMin
noNotification
nonPersistent Minimum cell UL bit rate. One cell bit rate sample is obtained by dividing
readOnly the total volume (PDCP SDU) on Data Radio Bearers aggregated to cell
level, that has been received in the uplink direction, with the time (in
seconds) of the sample gathering period.

Unit: 1 kbps
Condition: The counter is set equal to the low mark sample at the end of
each Recording Output Period (ROP).
Counter type: GAUGE
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpDelayTimeDl
noNotification
nonPersistent Aggregated time for the downlink delay measure. One sample per
readOnly successful transmission of a packet (PDCP SDU). The time for each sample
is between reception of a packet (PDCP SDU) until the successful
transmission of the corresponding MAC SDU.

Unit: 1 ms

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 70 of 162

Deprecated: Since L10B. Has no functional behaviour.

Condition: Continuous measurement for UEs aggregated to cell level.


Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpLatPktTransDl
noNotification
nonPersistent Number of DRB packets for downlink Latency measurements.
readOnly
When carrier aggregation is used, the DL Latency for all component carriers
is registered on the UE's primary component carrier (PCell).

Filter: FDD
Condition: Measurement for UEs aggregated to cell level. Only PDCP SDUs
that enters an empty buffer are measured. Samples during handover are
excluded since they can distort the interpretation of the result (due to
packet forwarding, the target cell might have to buffer data before it is
possible to schedule the UE in the target cell, hence it would be an
increased Latency measurement if it would be included. It would however
not lead to a degraded performance for the end-user, due to packet
forwarding).
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmPdcpLatPktTransDlDrxNoSync
noNotification
nonPersistent Number of DRB packets for downlink Latency measurements when DRX is
readOnly active and the UE has UL synchronization status "NOT synchronized".

When carrier aggregation is used, the DL Latency for all component carriers
is registered on the UE's primary component carrier (PCell).

Filter: FDD
Condition: Measurement for UEs aggregated to cell level. Only PDCP SDUs
that enters an empty buffer are measured. Samples during handover are
excluded since they can distort the interpretation of the result (due to
packet forwarding, the target cell might have to buffer data before it is
possible to schedule the UE in the target cell, hence it would be an
increased Latency measurement if it would be included. It would however
not lead to a degraded performance for the end-user, due to packet
forwarding). The samples are included
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpLatPktTransDlDrxSync
noNotification
nonPersistent Number of DRB packets for downlink Latency measurements when DRX is
readOnly active and the UE has UL synchronization status "synchronized".

When carrier aggregation is used, the DL Latency for all component carriers
is registered on the UE's primary component carrier (PCell).

Filter: FDD
Condition: Measurement for UEs aggregated to cell level. Only PDCP SDUs
that enters an empty buffer are measured. Samples during handover are
excluded since they can distort the interpretation of the result (due to
packet forwarding, the target cell might have to buffer data before it is
possible to schedule the UE in the target cell, hence it would be an

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 71 of 162

increased Latency measurement if it would be included. It would however


not lead to a degraded performance for the end-user, due to packet
forwarding). The samples are included
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpLatPktTransDlNoDrxSync
noNotification
nonPersistent Number of DRB packets for downlink Latency measurements when DRX is
readOnly NOT active and the UE has UL synchronization status "synchronized".

When carrier aggregation is used, the DL Latency for all component carriers
is registered on the UE's primary component carrier (PCell).

Filter: FDD
Condition: Measurement for UEs aggregated to cell level. Only PDCP SDUs
that enters an empty buffer are measured. Samples during handover are
excluded since they can distort the interpretation of the result (due to
packet forwarding, the target cell might have to buffer data before it is
possible to schedule the UE in the target cell, hence it would be an
increased Latency measurement if it would be included. It would however
not lead to a degraded performance for the end-user, due to packet
forwarding). The samples are included
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmPdcpLatPktTransDlQci
nonUnique
noNotification Number of samples for DL Latency measurements during measurement
nonPersistent period per QCI.
readOnly
When carrier aggregation is used, the DL Latency for all component carriers
is registered on the UE's primary component carrier (PCell).

Compressed: True

Filter: FDD
Condition: The counter registers the number of samples for DL Latency
measurements during measurement period per QCI.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpLatTimeDl
noNotification
nonPersistent Aggregated DL Latency for a measurement period. The effective DL Latency
readOnly time comprises the time from PDCP DRB SDU entering the buffer until the
first data has been transmitted to the UE.

When carrier aggregation is used, the DL Latency for all component carriers
is registered on the UE's primary component carrier (PCell).

Unit: 1 ms
Filter: FDD
Condition: Measurement for UEs aggregated to cell level. Only PDCP SDUs
that enters an empty buffer are measured. Samples during handover are
excluded since they can distort the interpretation of the result (due to
packet forwarding, the target cell might have to buffer data before it is
possible to schedule the UE in the target cell, hence it would be an
increased Latency measurement if it would be included. It would however
not lead to a degraded performance for the end-user, due to packet

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 72 of 162

forwarding).
Counter type: ACC
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmPdcpLatTimeDlDrxNoSync
noNotification
nonPersistent Aggregated DL Latency when DRX is active and the UE has UL
readOnly synchronization status "NOT synchronized".

When carrier aggregation is used, the DL Latency for all component carriers
is registered on the UE's primary component carrier (PCell).

Filter: FDD
Condition: The effective DL Latency time comprises the time from PDCP
DRB SDU entering the buffer until the first data has been transmitted to the
UE. Measurement for UEs aggregated to cell level. Only PDCP SDUs that
enters an empty buffer are measured. Samples during handover are
excluded since they can distort the interpretation of the result (due to
packet forwarding, the target cell might have to buffer data before it is
possible to schedule the UE in the target cell, hence it would be an
increased Latency measurement if it would be included. It would however
not lead to a degraded performance for the end-user, due to packet
forwarding).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpLatTimeDlDrxSync
noNotification
nonPersistent Aggregated DL Latency when DRX is active and the UE has UL
readOnly synchronization status "synchronized".

When carrier aggregation is used, the DL Latency for all component carriers
is registered on the UE's primary component carrier (PCell).

Filter: FDD
Condition: The effective DL Latency time comprises the time from PDCP
DRB SDU entering the buffer until the first data has been transmitted to the
UE. Measurement for UEs aggregated to cell level. Only PDCP SDUs that
enters an empty buffer are measured. Samples during handover are
excluded since they can distort the interpretation of the result (due to
packet forwarding, the target cell might have to buffer data before it is
possible to schedule the UE in the target cell, hence it would be an
increased Latency measurement if it would be included. It would however
not lead to a degraded performance for the end-user, due to packet
forwarding).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpLatTimeDlNoDrxSync
noNotification
nonPersistent Aggregated DL Latency when DRX is NOT active and the UE has UL
readOnly synchronization status "synchronized".

When carrier aggregation is used, the DL Latency for all component carriers
is registered on the UE's primary component carrier (PCell).

Filter: FDD
Condition: The effective DL Latency time comprises the time from PDCP
DRB SDU entering the buffer until the first data has been transmitted to the

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 73 of 162

UE. Measurement for UEs aggregated to cell level. Only PDCP SDUs that
enters an empty buffer are measured. Samples during handover are
excluded since they can distort the interpretation of the result (due to
packet forwarding, the target cell might have to buffer data before it is
possible to schedule the UE in the target cell, hence it would be an
increased Latency measurement if it would be included. It would however
not lead to a degraded performance for the end-user, due to packet
forwarding).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmPdcpLatTimeDlQci
nonUnique
noNotification Aggregated DL Latency for a measurement period per QCI.
nonPersistent When carrier aggregation is used, the DL Latency for all component carriers
readOnly is registered on the UE's primary component carrier (PCell).

Compressed: True

Unit: 1 ms

Filter: FDD
Condition: The counter represents DL latency per QCI. The effective DL
Latency time comprises the time from PDCP SDU entering the buffer until
the first data has been transmitted to the UE. Only latency for PDCP SDUs
that enters an empty buffer is measured. Samples during handover are
excluded.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpPktDiscDlAqm
noNotification
nonPersistent Total number of packets (PDCP SDUs) discarded due to Active Queue
readOnly Management (AQM).

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). Total number of packets (PDCP SDUs) discarded due
to AQM is measured on PCell.

Filter: FDD
Condition: When a packet is discarded due to AQM
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmPdcpPktDiscDlAqmQci
nonUnique
noNotification Total number of packets (PDCP SDUs) per QCI discarded due to Active
nonPersistent Queue Management (AQM).
readOnly
When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). Total number of packets (PDCP SDUs) per QCI
discarded due to AQM is measured on PCell.

Compressed: True

Filter: FDD
Condition: When a packet is discarded due to AQM

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 74 of 162

Counter type: PDF


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpPktDiscDlHo
noNotification
nonPersistent Number of DRB packets (PDCP SDUs) discarded in downlink due to
readOnly handover and reestablishment procedures.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total number of packets (PDCP SDUs) discarded
in the downlink due to handover and reestablishment procedures is
measured on PCell.

Filter: FDD
Condition: The counter can be incremented from both source and target
point of view in the handover functionality. Discards in the target eNB could
be due to out of order sequence. Discards in the source eNB includes
discards of PDCP SDU packets not positively acknowledged for which it was
decided that no more transmission attempts on either Uu, X2 or S1
interface will be done. In the reestablishment functionality, packets in the
PDCP buffer are discarded due to the reestablishment procedure. Only
applicable to DRB packets.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmPdcpPktDiscDlHoQci
nonUnique
noNotification Total number of DL packets (PDCP SDUs) discarded due to HO per QCI.
nonPersistent
readOnly When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). Total number of DL packets (PDCP SDUs) discarded
due to HO per QCI is measured on PCell.

Compressed: True

Filter: FDD
Condition: The counter can be incremented from both source and target
point of view in the handover functionality. Discards in the target eNB could
be due to out of order sequence. Discards in the source eNB includes
discards of packets not positively acknowledged PDCP SDU for which it was
decided that no more transmission attempts on either Uu, X2 or S1
interface will be done. Only applicable to DRB packets.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpPktDiscDlPelr
noNotification
nonPersistent Total number of DRB packets (PDCP SDUs) for which no part has been
readOnly transmitted over the air in the downlink that are discarded due to reasons
other than handover or active queue management.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). Total number of DRB packets (PDCP SDUs) discarded
due to reasons other than handover or active queue management is
measured on PCell.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 75 of 162

Filter: FDD
Condition: Continuous measurement for UEs aggregated to cell level.
Counter type: ACC
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..256] pmPdcpPktDiscDlPelrQci
nonUnique
noNotification Total number of DL packets (PDCP SDUs) per QCI that are discarded in the
nonPersistent PDCP layer due to reasons other than handover or active queue
readOnly management. No part of these packets has been transmitted over the air.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). Total number of DL packets (PDCP SDUs) per QCI
discarded due to reasons other than handover or active queue management
is measured on PCell.

Compressed: True

Filter: FDD
Condition: The bin accumulates the number of DL PDCP SDUs discarded not
due to HO or active queue management per QCI.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpPktDiscDlPelrUu
noNotification
nonPersistent Total number of packets (PDCP SDUs) for which at least a part has been
readOnly transmitted over the air in the downlink direction but not positively
acknowledged, and it was decided that no more transmission attempts will
be done, due to reasons other than handover. Only applicable to DRB
packets.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). Total number of packets (PDCP SDUs) for which at
least a part has been transmitted over the air in the downlink direction but
not positively acknowledged, and it was decided that no more transmission
attempts will be done, due to reasons other than handover, is measured on
PCell.

Filter: FDD
Condition: Continuous measurement for UEs aggregated to cell level.
Counter type: ACC
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..256] pmPdcpPktDiscDlPelrUuQci
nonUnique
noNotification Total number of DL packets (PDCP SDUs) per QCI for which at least a part
nonPersistent has been transmitted over the air but not positively acknowledged due to
readOnly reasons other than handover, and it was decided that no more transmission
attempts will be done.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). Total number of DL packets (PDCP SDUs) per QCI for
which at least a part has been transmitted over the air but not positively
acknowledged due to reasons other than handover, and it was decided that
no more transmission attempts will be done, is measured on PCell.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 76 of 162

Compressed: True

Filter: FDD
Condition: The bin accumulates the number of DL PDCP SDUs that are not
successfully transmitted due to reasons other than HO per QCI.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpPktFwdDl
noNotification
nonPersistent Total number of DRB packets (PDCP SDUs) forwarded to target cell at
readOnly handover for downlink sessions.

Condition: Packet forwarding is started when source cell transmit


RRCConnectionReconfiguration and is stopped when source receives the
end marker or when the source receives UE Context Release from target or
timer tHODataFwdReordering has expiered.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpPktLostUl
noNotification
nonPersistent Total number of DRB packets (PDCP SDUs) lost in the uplink.
readOnly
Condition: Continuous measurement for UEs aggregated to cell level.
Counter type: ACC
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..256] pmPdcpPktLostUlQci
nonUnique
noNotification Total number of UL packets (PDCP SDUs) lost per QCI.
nonPersistent Compressed: True
readOnly
Condition: The bin accumulates the number of UL PDCP SDUs that are lost
per QCI.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpPktPdbUlOkVoip
noNotification
nonPersistent The number of RLC SDU (PDCP SDU) in UL that are received within the
readOnly Packet Delay Budget in Uplink. Only applicable for VoIP.

Condition: Incremented when a VoIP packet has an air interface delay


within the packet delay budget.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpPktReceivedDl
noNotification
nonPersistent Total number of DRB packets (PDCP SDUs) received by RBS in PDCP in the
readOnly downlink.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). Total number of DRB packets (PDCP SDUs) received
by RBS in PDCP in the downlink is measured on PCell.

Filter: FDD

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 77 of 162

Condition: Continuous measurement for UEs aggregated to cell level.


Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmPdcpPktReceivedDlQci
nonUnique
noNotification Total number of DL packets (PDCP SDUs) received in PDCP in the RBS per
nonPersistent QCI.
readOnly
When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). Total number of DL packets (PDCP SDUs) received in
PDCP in the RBS per QCI is measured on PCell.

Compressed: True

Filter: FDD
Condition: The bin accumulates the number of DL PDCP SDUs received per
QCI.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpPktReceivedUl
noNotification
nonPersistent Total number of DRB packets (PDCP SDUs) received in the uplink.
readOnly
Condition: Continuous measurement for UEs aggregated to cell level.
Counter type: ACC
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..256] pmPdcpPktReceivedUlQci
nonUnique
noNotification Total number of UL packets (PDCP SDUs) received per QCI.
nonPersistent Compressed: True
readOnly
Condition: The bin accumulates the number of UL PDCP SDUs that are
successfully received per QCI.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpPktTransDl
noNotification
nonPersistent Total number of DRB packets (PDCP SDUs) successfully transmitted (RLC
readOnly acknowledged by UE) in the downlink.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). Total number of DRB packets (PDCP SDUs)
successfully transmitted (RLC acknowledged by UE) in the downlink is
measured on PCell.

Filter: FDD
Condition: Continuous measurement for UEs aggregated to cell level.
Counter type: ACC
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..256] pmPdcpPktTransDlQci
nonUnique
noNotification

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 78 of 162

nonPersistent Total number of DL packets (PDCP SDUs) transmitted successfully per QCI.
readOnly

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). Total number of DL packets (PDCP SDUs) transmitted
successfully per QCI is measured on PCell.

Compressed: True

Filter: FDD
Condition: The bin accumulates the number of DL PDCP SDUs that are
transmitted successfully per QCI.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmPdcpVolDlCmpHdrQci
nonUnique
noNotification The total volume of compressed PDCP SDU headers that has been
nonPersistent transmitted from the Robust Header Compression entity in the downlink
readOnly direction per QCI.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total volume of compressed PDCP SDU headers
that has been transmitted from the Robust Header Compression entity in
the downlink direction per QCI is measured on PCell.

Compressed: True

Unit: 1 kilobit (1000 bits)

Filter: FDD
Condition: Continuous measurement for DRBs aggregated to cell level.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpVolDlDrb
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly transferred (acknowledged by the UE) in the downlink direction.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total volume (PDCP SDU) on Data Radio Bearers
that has been transferred (acknowledged by the UE) in the downlink
direction is measured on PCell.

Unit: 1 kilobit (1 000 bits)


Filter: FDD
Condition: Continuous measurement for DRBs aggregated to cell level.
Counter type: ACC
Sampling rate: Per TTI
Scanner: Primary
Counter is reset after measurement period: Yes
long pmPdcpVolDlDrbLastTTI
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly transferred (acknowledged by the UE) in the downlink direction in the last
TTI when a buffer is emptied.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total volume (PDCP SDU) on Data Radio Bearers

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 79 of 162

that has been transferred (acknowledged by the UE) in the downlink


direction in the last TTI when a buffer is emptied is measured on PCell.

Unit: 1 kilobit (1 000 bits)


Condition: Continuous measurement for UEs aggregated to cell level.
Counter type: ACC
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..256] pmPdcpVolDlDrbLastTTIQci
nonUnique
noNotification The total DL PDCP SDU volume per QCI that is transmitted in the last TTI
nonPersistent when the buffer for a DRB that maps to the given QCI is emptied.
readOnly
When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total DL PDCP SDU volume per QCI that is
transmitted in the last TTI when the buffer for a DRB that maps to the
given QCI is emptied is measured on PCell.

Compressed: True

Unit: 1 kilobit (1000 bits)

Condition: The bin accumulates the DL PDCP SDU volume per QCI that is
transmitted in the last TTI when the buffer for a DRB that maps to the
given QCI is emptied.
Counter type: PDF
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..256] pmPdcpVolDlDrbQci
nonUnique
noNotification The total volume (PDCP SDU) that has been transferred (acknowledged by
nonPersistent the UE) on Data Radio Bearers in the downlink direction per QCI.
readOnly
When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total volume (PDCP SDU) that has been
transferred (acknowledged by the UE) on Data Radio Bearers in the
downlink direction per QCI is measured on PCell.

Compressed: True

Unit: 1 kilobit (1 000 bits)

Filter: FDD
Condition: The counter accumulates acknowledged DL PDCP volume per
QCI.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpVolDlDrbTrans
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly transmitted in the downlink direction in the PDCP layer.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total volume (PDCP SDU) on Data Radio Bearers
that has been transmitted in the downlink direction in the PDCP layer is
measured on PCell.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 80 of 162

Unit: 1 kilobit (1 000 bits)


Filter: FDD
Condition: Continuous measurement for DRBs aggregated to cell level.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpVolDlDrbTransPlmn0
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly transmitted in the downlink direction in the PDCP layer for the UEs served
by PLMN0.

PLMN0 refers to the PLMN configured in the attribute eNodeBPlmnId located


on ENodeBFunction.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total volume (PDCP SDU) on Data Radio Bearers
that has been transmitted in the downlink direction in the PDCP layer for
the UEs served by PLMN0 is measured on PCell.

Unit: 1 kilobit (1 000 bits)


Filter: FDD
Condition: Traffic volume counter accumulates transferred volume from
PDCP to RLC layer for Plmn0.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpVolDlDrbTransPlmn1
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly transmitted in the downlink direction in the PDCP layer for the UEs served
by PLMN1.

PLMN1 refers to the PLMN configured in the attribute additionalPlmnList[0]


located on EUtranCellFDD or EUtranCellTDD.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total volume (PDCP SDU) on Data Radio Bearers
that has been transmitted in the downlink direction in the PDCP layer for
the UEs served by PLMN1 is measured on PCell.

Unit: 1 kilobit (1 000 bits)


Filter: FDD
Condition: Traffic volume counter accumulates transferred volume from
PDCP to RLC layer for Plmn1.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpVolDlDrbTransPlmn2
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly transmitted in the downlink direction in the PDCP layer for the UEs served
by PLMN2.

PLMN2 refers to the PLMN configured in the attribute additionalPlmnList[1]


located on EUtranCellFDD or EUtranCellTDD.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 81 of 162

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total volume (PDCP SDU) on Data Radio Bearers
that has been transmitted in the downlink direction in the PDCP layer for
the UEs served by PLMN2 is measured on PCell.

Unit: 1 kilobit (1 000 bits)


Filter: FDD
Condition: Traffic volume counter accumulates transferred volume from
PDCP to RLC layer for Plmn2.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpVolDlDrbTransPlmn3
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly transmitted in the downlink direction in the PDCP layer for the UEs served
by PLMN3.

PLMN3 refers to the PLMN configured in the attribute additionalPlmnList[2]


located on EUtranCellFDD or EUtranCellTDD.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total volume (PDCP SDU) on Data Radio Bearers
that has been transmitted in the downlink direction in the PDCP layer for
the UEs served by PLMN3 is measured on PCell.

Unit: 1 kilobit (1 000 bits)


Filter: FDD
Condition: Traffic volume counter accumulates transferred volume from
PDCP to RLC layer for Plmn3.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpVolDlDrbTransPlmn4
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly transmitted in the downlink direction in the PDCP layer for the UEs served
by PLMN4.

PLMN4 refers to the PLMN configured in the attribute additionalPlmnList[3]


located on EUtranCellFDD or EUtranCellTDD.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total volume (PDCP SDU) on Data Radio Bearers
that has been transmitted in the downlink direction in the PDCP layer for
the UEs served by PLMN4 is measured on PCell.

Unit: 1 kilobit (1 000 bits)


Filter: FDD
Condition: Traffic volume counter accumulates transferred volume from
PDCP to RLC layer for Plmn4.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpVolDlDrbTransPlmn5
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly transmitted in the downlink direction in the PDCP layer for the UEs served

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 82 of 162

by PLMN5.

PLMN5 refers to the PLMN configured in the attribute additionalPlmnList[4]


located on EUtranCellFDD or EUtranCellTDD.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total volume (PDCP SDU) on Data Radio Bearers
that has been transmitted in the downlink direction in the PDCP layer for
the UEs served by PLMN5 is measured on PCell.

Unit: 1 kilobit (1 000 bits)


Filter: FDD
Condition: Traffic volume counter accumulates transferred volume from
PDCP to RLC layer for Plmn5.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpVolDlDrbTransPlmn6
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly transmitted in the downlink direction in the PDCP layer for the UEs served
by PLMN6.

PLMN6 refers to an unexpected PLMN, that is, a PLMN that cannot be


associated with any PLMN configured in the ENodeBFunction or cell.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total volume (PDCP SDU) on Data Radio Bearers
that has been transmitted in the downlink direction in the PDCP layer for
the UEs served by PLMN6 is measured on PCell.

Unit: 1 kilobit (1 000 bits)


Filter: FDD
Condition: Traffic volume counter accumulates transferred volume from
PDCP to RLC layer for Plmn6.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmPdcpVolDlDrbTransQci
nonUnique
noNotification The total volume (PDCP SDU) on Data Radio Bearers that has been
nonPersistent transmitted in the downlink direction in the PDCP layer per QCI.
readOnly
When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total volume (PDCP SDU) on Data Radio Bearers
that has been transmitted in the downlink direction in the PDCP layer per
QCI is measured on PCell.

Compressed: True

Unit: 1 kilobit (1000 bits)

Filter: FDD
Condition: Continuous measurement after Robust Header Compression for
DRBs aggregated to cell level.
Counter type: PDF
Sampling rate: -

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 83 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long pmPdcpVolDlDrbTransUm
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers for RLC UM that has
readOnly been transmitted in the downlink direction in the PDCP layer.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total volume (PDCP SDU) on Data Radio Bearers
for RLC UM that has been transmitted in the downlink direction in the PDCP
layer is measured on PCell.

Filter: FDD
Condition: Continuous measurement after Robust Header Compression for
DRBs aggregated to cell level
Counter type: ACC
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..256] pmPdcpVolDlHdrQci
nonUnique
noNotification The total volume of uncompressed PDCP SDU headers that has been
nonPersistent received in the Robust Header Compression entity in the downlink direction
readOnly per QCI.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total volume of uncompressed PDCP SDU headers
that has been received in the Robust Header Compression entity in the
downlink direction per QCI is measured on PCell.

Compressed: True

Unit: 1 kilobit (1000 bits)

Filter: FDD
Condition: Continuous measurement for DRBs aggregated to cell level.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpVolDlSrb
noNotification
nonPersistent The total number of bits (PDCP SDU) on Signalling Radio Bearers that has
readOnly been transferred (acknowledged by the UE) in the downlink direction.

SRB0 volume is not included in this counter.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total number of bits (PDCP SDU) on Signalling
Radio Bearers that has been transferred (acknowledged by the UE) in the
downlink direction is measured on PCell.

Unit: 1 kilobit (1 000 bits)


Filter: FDD
Condition: Continuous measurement for SRBs aggregated to cell level.
Counter type: ACC
Sampling rate: Per TTI
Scanner: Primary
Counter is reset after measurement period: Yes
long pmPdcpVolDlSrbTrans
noNotification

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 84 of 162

nonPersistent The total volume (PDCP SDU) on Signalling Radio Bearers that has been
readOnly
transmitted in the downlink direction in the PDCP layer.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The total volume (PDCP SDU) on Signalling Radio
Bearers that has been transmitted in the downlink direction in the PDCP
layer is measured on PCell.

Unit: 1 kilobit (1 000 bits)


Filter: FDD
Condition: Continuous measurement for SRBs aggregated to cell level.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmPdcpVolUlCmpHdrQci
nonUnique
noNotification The total volume of compressed PDCP SDU headers that has been received
nonPersistent in the Robust Header Compression entity in the uplink direction per QCI.
readOnly
Compressed: True

Unit: 1 kilobit (1000 bits)

Condition: Continuous measurement for DRBs aggregated to cell level.


Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpVolUlDrb
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly received in the uplink direction.

Unit: 1 kilobit (1 000 bits)


Condition: Continuous measurement for DRBs aggregated to cell level.
Counter type: ACC
Sampling rate: Per TTI
Scanner: Primary
Counter is reset after measurement period: Yes
long pmPdcpVolUlDrbLastTTI
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly received in the uplink direction in the last TTI when a buffer is emptied.

Unit: 1 kilobit (1 000 bits)


Deprecated:  Since L12A. Replaced by pmUeThpVolUl.

Condition: Continuous measurement for UEs aggregated to cell level.


Counter type: ACC
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmPdcpVolUlDrbPlmn0
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly received in the uplink direction for the UEs served by PLMN0.

PLMN0 refers to the PLMN configured in the attribute eNodeBPlmnId located


on ENodeBFunction.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 85 of 162

Unit: 1 kilobit (1 000 bits)


Condition: Continuous measurement for DRBs aggregated to cell level for
Plmn0.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpVolUlDrbPlmn1
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly received in the uplink direction for the UEs served by PLMN1.

PLMN1 refers to the PLMN configured in the attribute additionalPlmnList[0]


located on EUtranCellFDD or EUtranCellTDD.

Unit: 1 kilobit (1 000 bits)


Condition: Continuous measurement for DRBs aggregated to cell level for
Plmn1.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpVolUlDrbPlmn2
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly received in the uplink direction for the UEs served by PLMN2.

PLMN2 refers to the PLMN configured in the attribute additionalPlmnList[1]


located on EUtranCellFDD or EUtranCellTDD.

Unit: 1 kilobit (1 000 bits)


Condition: Continuous measurement for DRBs aggregated to cell level for
Plmn2.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpVolUlDrbPlmn3
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly received in the uplink direction for the UEs served by PLMN3.

PLMN3 refers to the PLMN configured in the attribute additionalPlmnList[2]


located on EUtranCellFDD or EUtranCellTDD.

Unit: 1 kilobit (1 000 bits)


Condition: Continuous measurement for DRBs aggregated to cell level for
Plmn3.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 86 of 162

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpVolUlDrbPlmn4
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly received in the uplink direction for the UEs served by PLMN4.

PLMN4 refers to the PLMN configured in the attribute additionalPlmnList[3]


located on EUtranCellFDD or EUtranCellTDD.

Unit: 1 kilobit (1 000 bits)


Condition: Continuous measurement for DRBs aggregated to cell level for
Plmn4.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpVolUlDrbPlmn5
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly received in the uplink direction for the UEs served by PLMN5.

PLMN5 refers to the PLMN configured in the attribute additionalPlmnList[4]


located on EUtranCellFDD or EUtranCellTDD.

Unit: 1 kilobit (1 000 bits)


Condition: Continuous measurement for DRBs aggregated to cell level for
Plmn5.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpVolUlDrbPlmn6
noNotification
nonPersistent The total volume (PDCP SDU) on Data Radio Bearers that has been
readOnly received in the uplink direction for the UEs served by PLMN6.

PLMN6 refers to an unexpected PLMN, that is, a PLMN that cannot be


associated with any PLMN configured in the ENodeBFunction or cell.

Unit: 1 kilobit (1 000 bits)


Condition: Continuous measurement for DRBs aggregated to cell level for
Plmn6.

Counter type: ACC


Sampling rate: -

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 87 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long[0..256] pmPdcpVolUlDrbQci
nonUnique
noNotification The total volume (PDCP SDU) that has been received on Data Radio
nonPersistent Bearers in the uplink direction per QCI.
readOnly
Compressed: True

Unit: 1 kilobit (1 000 bits)

Condition: The counter accumulates received UL PDCP volume per QCI.


Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmPdcpVolUlHdrQci
nonUnique
noNotification The total volume of decompressed PDCP SDU headers that has been
nonPersistent transmitted from the Robust Header Compression entity in the uplink
readOnly direction per QCI.

Compressed: True

Unit: 1 kilobit (1000 bits)

Condition: Continuous measurement for DRBs aggregated to cell level.


Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPdcpVolUlSrb
noNotification
nonPersistent The total number of bits (PDCP SDU) on Signaling Radio Bearers that has
readOnly been transferred (acknowledged by the RBS) in the uplink direction.

SRB0 volume is not included in this counter.

Unit: 1 kilobit (1 000 bits)


Condition: Continuous measurement for SRBs aggregated to cell level.
Counter type: ACC
Sampling rate: Per TTI
Scanner: Primary
Counter is reset after measurement period: Yes
long pmPrbAvailDl
noNotification
nonPersistent The total number of Physical Resource Block (PRB) pairs available for
readOnly transmission in the downlink.

Condition: This measurement is applicable for the Physical Downlink Shared


Channel (PDSCH)
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPrbAvailDlMbms
noNotification
nonPersistent The total number of Physical Resource Blocks (PRB) available for MBMS
readOnly transmission in the downlink.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 88 of 162

Condition: This measurement is applicable for the Physical Multicast


Channel (PMCH).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPrbAvailUl
noNotification
nonPersistent The total number of Physical Resource Block (PRB) pairs available for
readOnly transmission in the uplink.

Condition: This measurement is applicable for the Physical Uplink Shared


Channel (PUSCH).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPrbUsedDl
noNotification
nonPersistent The total number of PRBs used in the downlink direction.
readOnly

Deprecated: Since L11A. Has no functional behaviour.

Condition: Continuous measurement on TTI granularity on cell level.


Counter type: ACC
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmPrbUsedDlAilgHighPrio
noNotification
nonPersistent The total number of PRB pairs generated by Air Interface Load Generator in
readOnly the DL direction for load of higher priority than the real UEs load

Condition: Continuous measurement on TTI granularity on cell level


Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPrbUsedDlAilgTot
noNotification
nonPersistent The total number of PRB pairs generated by Air Interface Load Generator in
readOnly DL for artificial load, both for high and low priority load.

Condition: Continuous measurement on TTI granularity on cell level


Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPrbUsedDlBcch
noNotification
nonPersistent The total number of Physical Resource Block (PRB) pairs used for System
readOnly Information.

Condition: This measurement is applicable to the Broadcast Control


Channel (BCCH) on the Physical Downlink Shared Channel (PDSCH).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPrbUsedDlCcch
noNotification
nonPersistent The total number of PRBs used for Common Control Channels in the
readOnly downlink direction.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 89 of 162

Deprecated: Since L11A. Has no functional behaviour.

Condition: Continuous measurement on TTI granularity aggregated to cell


level. This measurement is applicable to Broadcast Control Channel (BCCH)
and Paging Control Channel (PCCH).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPrbUsedDlDtch
noNotification
nonPersistent The total number of Physical Resource Block (PRB) pairs used for Data
readOnly Radio Bearers (DRB) in the downlink.

Condition: This measurement is applicable to the Dedicated Traffic Channel


(DTCH) on the Physical Downlink Shared Channel (PDSCH).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmPrbUsedDlDtchFirstTransQci
nonUnique
noNotification The total number of PRB pairs used in DL per QCI for HARQ initial
nonPersistent transmissions.
readOnly
Compressed: True

Condition: The bin accumulates the number of PRB pairs used in DL per QCI
for HARQ initial transmissions.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPrbUsedDlFirstTrans
noNotification
nonPersistent The total number of PRB pairs used in DL for HARQ initial transmissions.
readOnly
Condition: The counter accumulates the number of PRB pairs used in DL for
HARQ initial transmissions.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPrbUsedDlMbms
noNotification
nonPersistent The total number of Physical Resource Blocks (PRB) used by MBMS
readOnly transmission in the downlink

Condition: This measurement is applicable to the Multicast Channel (MCH)


on the Physical Multicast Channel (PMCH).

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPrbUsedDlPcch
noNotification
nonPersistent The total number of Physical Resource Block (PRB) pairs used for paging.
readOnly
Condition: This measurement is applicable to the Paging Control

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 90 of 162

Channel (PCCH) on the Physical Downlink Shared Channel (PDSCH).


Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPrbUsedDlReTrans
noNotification
nonPersistent The total number of PRB pairs used in DL for HARQ retransmissions.
readOnly
Condition: The counter accumulates the number of PRB pairs used in DL for
HARQ retransmissions.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPrbUsedDlSrb
noNotification
nonPersistent The total number of Physical Resource Blocks (PRB) used for Signaling
readOnly Radio Bearers (SRB) in the downlink.

Deprecated: Since L12A. Replaced by pmPrbUsedDlSrbFirstTrans. Has no


functional behaviour.

Condition: This measurement is applicable to Dedicated Control Channels


(DCCH) and Common Control Channels (CCCH) on the Physical Downlink
Shared Channel (PDSCH).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPrbUsedDlSrbFirstTrans
noNotification
nonPersistent The total number of Physical Resource Block (PRB) pairs for HARQ initial
readOnly transmissions used for Signaling Radio Bearers (SRB) in the downlink.

Condition: This measurement is applicable to Dedicated Control Channels


(DCCH) and Common Control Channels (CCCH) on the Physical Downlink
Shared Channel (PDSCH).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPrbUsedUl
noNotification
nonPersistent The total number of PRBs used in the uplink direction.
readOnly

Deprecated: Since L11A. Has no functional behaviour.

Condition: Continuous measurement on TTI granularity on cell level.


Counter type: ACC
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmPrbUsedUlAilgTot
noNotification
nonPersistent The total number of PRB pairs generated by Air Interface Load Generator in
readOnly UL for artificial load, both for high and low priority load

Condition: Continuous measurement on TTI granularity on cell level


Counter type: ACC
Sampling rate: -

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 91 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long pmPrbUsedUlCcch
noNotification
nonPersistent The total number of PRBs used for Common Control Channels in the uplink
readOnly direction.

Deprecated: Since L11A. Has no functional behaviour.

Condition: Continuous measurement on TTI granularity aggregated to cell


level. This measurement is applicable to Random Access Channel (RACH)
and Physical Uplink Control Channel (PUCCH).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPrbUsedUlDtch
noNotification
nonPersistent The total number of Physical Resource Block (PRB) pairs used for Data
readOnly Radio Bearers (DRB) in the uplink.

Condition: This measurement is applicable to the Dedicated Traffic Channel


(DTCH) on the Physical Uplink Shared Channel (PUSCH).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmPrbUsedUlDtchQci
nonUnique
noNotification The total number of PRB pairs used in UL per QCI.
nonPersistent
readOnly Compressed: True

Condition: The bin accumulates the number of PRB pairs used in UL per
QCI.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPrbUsedUlSrb
noNotification
nonPersistent The total number of Physical Resource Block (PRB) pairs used for Signaling
readOnly Radio Bearers (SRB) in the uplink.

Condition: This measurement is applicable to Dedicated Control Channels


(DCCH) and Common Control Channels (CCCH) on the Physical Uplink
Shared Channel (PUSCH).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..10] pmPrbUtilDl
nonUnique
noNotification A distribution that shows the downlink Physical Resource Block (PRB) pair
nonPersistent utilization (total number of used PRB pairs by available PRB pairs) on the
readOnly Physical Downlink Shared Channel (PDSCH).

PDF ranges:
[0]: 0 % <= Utilization < 10 %
[1]: 10 % <= Utilization < 20 %
[2]: 20 % <= Utilization < 30 %
[3]: 30 % <= Utilization < 40 %

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 92 of 162

[4]: 40 % <= Utilization < 50 %


[5]: 50 % <= Utilization < 60 %
[6]: 60 % <= Utilization < 70 %
[7]: 70 % <= Utilization < 80 %
[8]: 80 % <= Utilization < 90 %
[9]: 90 % <= Utilization

Condition: One sample should be the utilization during the sample


gathering period.
Counter type: PDF
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..10] pmPrbUtilUl
nonUnique
noNotification A distribution that shows the uplink Physical Resource Block (PRB) pair
nonPersistent utilization (total number of used PRB pairs by available PRB pairs) on the
readOnly Physical Uplink Shared Channel (PUSCH).

PDF ranges:
[0]: 0 % <= Utilization < 10 %
[1]: 10 % <= Utilization < 20 %
[2]: 20 % <= Utilization < 30 %
[3]: 30 % <= Utilization < 40 %
[4]: 40 % <= Utilization < 50 %
[5]: 50 % <= Utilization < 60 %
[6]: 60 % <= Utilization < 70 %
[7]: 70 % <= Utilization < 80 %
[8]: 80 % <= Utilization < 90 %
[9]: 90 % <= Utilization

Condition: One sample should be the utilization during the sample


gathering period.
Counter type: PDF
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPucchFailSr
noNotification
nonPersistent Counts the number of received Scheduling Requests (SR) over RACH due to
readOnly a failure from the UE to access the node by means of SR over PUCCH.

Condition: The counter is increased each time a raMsg3 is received from a


UE which has SR resources on PUCCH and is in-synch.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPucchSr
noNotification
nonPersistent The total number of received Scheduling Requests on PUCCH.
readOnly
Condition: The counter aggregates the number of received scheduling
requests on PUCCH.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPucchSrCqiResAllocAtt
noNotification
nonPersistent Aggregated number of attempts to allocate PUCCH resources.
readOnly

Condition: In a typical case each allocation request is for one CQI resource

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 93 of 162

AND one SR resource; The counter is then increased with one for the
combined allocation request, not one for each resource requested. One
allocation request may also contain request for resources for more than one
UE (a bundled allocation request); Also in this case the counter is only
incremented with one.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPucchSrCqiResCongCqi
noNotification
nonPersistent The number of times a PUCCH allocation request for CQI resource(s) could
readOnly not be granted

Counter type: PEG


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPucchSrCqiResCongSr
noNotification
nonPersistent The number of times a PUCCH allocation request for SR resource(s) could
readOnly not be granted.

Counter type: PEG


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmPucchSrMax
noNotification
nonPersistent Peak number of received Scheduling Requests on PUCCH during a TTI.
readOnly
Condition: The counter is set to peak sample recognized at the end of each
Recording Output Period (ROP).
Counter type: GAUGE
Sampling rate: Per TTI
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRaAllocCfra
noNotification
nonPersistent The number of allocated CFRA preambles.
readOnly

Condition: This counter should be incremented whenever a CFRA preamble


is allocated in the Cell.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRaAttCbra
noNotification
nonPersistent The number of detected contention-based random access preambles.
readOnly

Condition: This counter should be incremented whenever a CBRA preamble


is detected in the Cell.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRaAttCfra
noNotification
nonPersistent The number of detected contention-free (explicitly signalled) random access
readOnly preambles.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 94 of 162

Condition: This counter should be incremented whenever a CFRA preamble


that has been allocated to a UE is detected in the Cell.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRachNumContentionReport
noNotification
nonPersistent This measurement provides the number of UEInformationResponse
readOnly messages received with contentionDetected IE set to TRUE.

Condition: Stepped at reception of UE INFORMATION RESPONSE message.


Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..10] pmRachPreambleDist
nonUnique
noNotification This measurement provides the distribution of number of RACH preambles
nonPersistent sent by the UE as reported by the UEs inside the UEInformationResponse
readOnly message according to 32.425
[0]: 1 preamble
[1]: 2 preambles
[2]: 3 preambles
[3]: 4 preambles
[4]: 5 preambles
[5]: 6 preambles
[6]: 7 preambles
[7]: 8 preambles
[8]: 9 preambles
[9]: >= 10 preambles

Condition: Stepped at reception of UE INFORMATION RESPONSE message.


Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..16] pmRadioRecInterferencePwr
nonUnique
noNotification The measured Noise and Interference Power on PUSCH, according to
nonPersistent 36.214
readOnly
PDF ranges:
[0]: N+I <= -121
[1]: -121 < N+I <= -120
[2]: -120 < N+I <= -119
[3]: -119 < N+I <= -118
[4]: -118 < N+I <= -117
[5]: -117 < N+I <= -116
[6]: -116 < N+I <= -115
[7]: -115 < N+I <= -114
[8]: -114< N+I <= -113
[9]: -113 < N+I <= -112
[10]: -112 < N+I <= -108
[11]: -108 < N+I <= -104
[12]: -104 < N+I <= -100
[13]: -100 < N+I <= -96
[14]: -96 < N+I <= -92
[15]: -92 < N+I

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 95 of 162

Unit: 1 dBm/PRB

Condition: A wideband value for the frequency domain is measured on a


TTI basis
Counter type: PDF
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..100] pmRadioRecInterferencePwrPrb
nonUnique
noNotification The accumulated interference power per PRB.
nonPersistent
readOnly PDF range:
[0]: 1st Prb starting from the low part of the spectrum
[1]: 2nd Prb starting from the low part of the spectrum
.....
[99]: 100th Prb starting from the low part of the spectrum

Unit: 1 mW * 2^(-48)

Deprecated: Since L12A. Has no functional behavior, planned to be


removed.

Condition: Samples summed over the measurement period. Measurements


are averaged over receive antennas.One sample per TTI
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb1
noNotification
nonPersistent The accumulated interference power for PRB1
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb10
noNotification
nonPersistent The accumulated interference power for PRB10
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb100
noNotification
nonPersistent The accumulated interference power for PRB100
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 96 of 162

long pmRadioRecInterferencePwrPrb11
noNotification
nonPersistent The accumulated interference power for PRB11
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb12
noNotification
nonPersistent The accumulated interference power for PRB12
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb13
noNotification
nonPersistent The accumulated interference power for PRB13
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb14
noNotification
nonPersistent The accumulated interference power for PRB14
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb15
noNotification
nonPersistent The accumulated interference power for PRB15
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb16
noNotification
nonPersistent The accumulated interference power for PRB16
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 97 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb17
noNotification
nonPersistent The accumulated interference power for PRB17
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb18
noNotification
nonPersistent The accumulated interference power for PRB18
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb19
noNotification
nonPersistent The accumulated interference power for PRB19
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb2
noNotification
nonPersistent The accumulated interference power for PRB2
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb20
noNotification
nonPersistent The accumulated interference power for PRB20
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb21
noNotification
nonPersistent The accumulated interference power for PRB21
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 98 of 162

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb22
noNotification
nonPersistent The accumulated interference power for PRB22
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb23
noNotification
nonPersistent The accumulated interference power for PRB23
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb24
noNotification
nonPersistent The accumulated interference power for PRB24
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb25
noNotification
nonPersistent The accumulated interference power for PRB25
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb26
noNotification
nonPersistent The accumulated interference power for PRB26
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb27
noNotification
nonPersistent The accumulated interference power for PRB27
readOnly
Unit: 1 mW * 2^(-48)

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 99 of 162

Condition: Samples summed over the measurement period. Measurements


are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb28
noNotification
nonPersistent The accumulated interference power for PRB28
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb29
noNotification
nonPersistent The accumulated interference power for PRB29
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb3
noNotification
nonPersistent The accumulated interference power for PRB3
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb30
noNotification
nonPersistent The accumulated interference power for PRB30
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb31
noNotification
nonPersistent The accumulated interference power for PRB31
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb32
noNotification

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 100 of 162

nonPersistent The accumulated interference power for PRB32


readOnly

Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb33
noNotification
nonPersistent The accumulated interference power for PRB33
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb34
noNotification
nonPersistent The accumulated interference power for PRB34
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb35
noNotification
nonPersistent The accumulated interference power for PRB35
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb36
noNotification
nonPersistent The accumulated interference power for PRB36
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb37
noNotification
nonPersistent The accumulated interference power for PRB37
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 101 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb38
noNotification
nonPersistent The accumulated interference power for PRB38
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb39
noNotification
nonPersistent The accumulated interference power for PRB39
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb4
noNotification
nonPersistent The accumulated interference power for PRB4
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb40
noNotification
nonPersistent The accumulated interference power for PRB40
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb41
noNotification
nonPersistent The accumulated interference power for PRB41
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb42
noNotification
nonPersistent The accumulated interference power for PRB42
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 102 of 162

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb43
noNotification
nonPersistent The accumulated interference power for PRB43
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb44
noNotification
nonPersistent The accumulated interference power for PRB44
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb45
noNotification
nonPersistent The accumulated interference power for PRB45
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb46
noNotification
nonPersistent The accumulated interference power for PRB46
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb47
noNotification
nonPersistent The accumulated interference power for PRB47
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb48
noNotification
nonPersistent The accumulated interference power for PRB48
readOnly
Unit: 1 mW * 2^(-48)

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 103 of 162

Condition: Samples summed over the measurement period. Measurements


are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb49
noNotification
nonPersistent The accumulated interference power for PRB49
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb5
noNotification
nonPersistent The accumulated interference power for PRB5
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb50
noNotification
nonPersistent The accumulated interference power for PRB50
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb51
noNotification
nonPersistent The accumulated interference power for PRB51
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb52
noNotification
nonPersistent The accumulated interference power for PRB52
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb53
noNotification

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 104 of 162

nonPersistent The accumulated interference power for PRB53


readOnly

Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb54
noNotification
nonPersistent The accumulated interference power for PRB54
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb55
noNotification
nonPersistent The accumulated interference power for PRB55
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb56
noNotification
nonPersistent The accumulated interference power for PRB56
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb57
noNotification
nonPersistent The accumulated interference power for PRB57
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb58
noNotification
nonPersistent The accumulated interference power for PRB58
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 105 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb59
noNotification
nonPersistent The accumulated interference power for PRB59
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb6
noNotification
nonPersistent The accumulated interference power for PRB6
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb60
noNotification
nonPersistent The accumulated interference power for PRB60
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb61
noNotification
nonPersistent The accumulated interference power for PRB61
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb62
noNotification
nonPersistent The accumulated interference power for PRB62
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb63
noNotification
nonPersistent The accumulated interference power for PRB63
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 106 of 162

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb64
noNotification
nonPersistent The accumulated interference power for PRB64
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb65
noNotification
nonPersistent The accumulated interference power for PRB65
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb66
noNotification
nonPersistent The accumulated interference power for PRB66
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb67
noNotification
nonPersistent The accumulated interference power for PRB67
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb68
noNotification
nonPersistent The accumulated interference power for PRB68
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb69
noNotification
nonPersistent The accumulated interference power for PRB69
readOnly
Unit: 1 mW * 2^(-48)

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 107 of 162

Condition: Samples summed over the measurement period. Measurements


are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb7
noNotification
nonPersistent The accumulated interference power for PRB7
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb70
noNotification
nonPersistent The accumulated interference power for PRB70
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb71
noNotification
nonPersistent The accumulated interference power for PRB71
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb72
noNotification
nonPersistent The accumulated interference power for PRB72
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb73
noNotification
nonPersistent The accumulated interference power for PRB73
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb74
noNotification

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 108 of 162

nonPersistent The accumulated interference power for PRB74


readOnly

Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb75
noNotification
nonPersistent The accumulated interference power for PRB75
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb76
noNotification
nonPersistent The accumulated interference power for PRB76
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb77
noNotification
nonPersistent The accumulated interference power for PRB77
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb78
noNotification
nonPersistent The accumulated interference power for PRB78
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb79
noNotification
nonPersistent The accumulated interference power for PRB79
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 109 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb8
noNotification
nonPersistent The accumulated interference power for PRB8
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb80
noNotification
nonPersistent The accumulated interference power for PRB80
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb81
noNotification
nonPersistent The accumulated interference power for PRB81
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb82
noNotification
nonPersistent The accumulated interference power for PRB82
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb83
noNotification
nonPersistent The accumulated interference power for PRB83
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb84
noNotification
nonPersistent The accumulated interference power for PRB84
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 110 of 162

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb85
noNotification
nonPersistent The accumulated interference power for PRB85
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb86
noNotification
nonPersistent The accumulated interference power for PRB86
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb87
noNotification
nonPersistent The accumulated interference power for PRB87
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb88
noNotification
nonPersistent The accumulated interference power for PRB88
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb89
noNotification
nonPersistent The accumulated interference power for PRB89
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb9
noNotification
nonPersistent The accumulated interference power for PRB9
readOnly
Unit: 1 mW * 2^(-48)

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 111 of 162

Condition: Samples summed over the measurement period. Measurements


are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb90
noNotification
nonPersistent The accumulated interference power for PRB90
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb91
noNotification
nonPersistent The accumulated interference power for PRB91
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb92
noNotification
nonPersistent The accumulated interference power for PRB92
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb93
noNotification
nonPersistent The accumulated interference power for PRB93
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb94
noNotification
nonPersistent The accumulated interference power for PRB94
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb95
noNotification

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 112 of 162

nonPersistent The accumulated interference power for PRB95


readOnly

Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb96
noNotification
nonPersistent The accumulated interference power for PRB96
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb97
noNotification
nonPersistent The accumulated interference power for PRB97
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb98
noNotification
nonPersistent The accumulated interference power for PRB98
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioRecInterferencePwrPrb99
noNotification
nonPersistent The accumulated interference power for PRB99
readOnly
Unit: 1 mW * 2^(-48)
Condition: Samples summed over the measurement period. Measurements
are averaged over receive antennas.One sample per TTI
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..16] pmRadioRecInterferencePwrPucch
nonUnique
noNotification The measured Noise and Interference Power on PUCCH, according to
nonPersistent 36.214.
readOnly
PDF ranges:
[0]: N+I <= -121
[1]: -121 < N+I <= -120
[2]: -120 < N+I <= -119
[3]: -119 < N+I <= -118

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 113 of 162

[4]: -118 < N+I <= -117


[5]: -117 < N+I <= -116
[6]: -116 < N+I <= -115
[7]: -115 < N+I <= -114
[8]: -114< N+I <= -113
[9]: -113 < N+I <= -112
[10]: -112 < N+I <= -108
[11]: -108 < N+I <= -104
[12]: -104 < N+I <= -100
[13]: -100 < N+I <= -96
[14]: -96 < N+I <= -92
[15]: -92 < N+I

Unit: 1 dBm/PRB

Condition: A wideband value for the frequency domain is measured on a


TTI basis
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioTbsPwrRestricted
noNotification
nonPersistent The number of Transport Blocks on MAC level scheduled in uplink where the
readOnly UE was considered to be power limited.

Condition: A Transport Block is considered to be power limited when the


estimated required transmit power is higher than the UE maximum transmit
power.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioTbsPwrUnrestricted
noNotification
nonPersistent The number of Transport Blocks on MAC level scheduled in uplink where the
readOnly UE was NOT considered to be power limited.

Condition: A Transport Block is considered to be power limited when the


estimated required transmit power is higher than the UE maximum transmit
power.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioThpResDl
noNotification
nonPersistent The total amount of physical resources used for transmission in the
readOnly downlink. Both successful and unsuccessful transmissions are counted.

Unit: 1 Resource Elements * 1000


Condition: The counter is incremented when HARQ feedback for a downlink
transmission is received, regardless of the feedback received (ACK or
NACK).
Counter type: ACC
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioThpResDlSelTbs
noNotification
The total amount of physical resources used for transmission in the
downlink for UEs that are considered to be in true radio conditions. Both

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 114 of 162

nonPersistent successful and unsuccessful transmissions are counted.


readOnly

Unit: 1 Resource Elements * 1000


Deprecated: Since L11A. Has no functional behaviour.

Condition: The counter is incremented when HARQ feedback for a downlink


transmission is received, regardless of the feedback received (ACK or
NACK). To the subset of UEs that are considered to be in true radio
conditions are UEs for which CQI has been received, are not buffer limited
and scheduled with sufficient transport block size.
Counter type: ACC
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioThpResUl
noNotification
nonPersistent The total amount of physical resources used for transmission in the uplink.
readOnly Both successful and unsuccessful transmissions are counted.

Unit: 1 Resource Elements * 1000


Condition: The counter is incremented when an uplink transmission is
received, regardless of whether the reception was successful or not.
Counter type: ACC
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioThpResUlSelTbs
noNotification
nonPersistent The total amount of physical resources used for transmission in the uplink
readOnly for UEs that are considered to be in true radio conditions. Both successful
and unsuccessful transmissions are counted.

Unit: 1 Resource Elements * 1000


Deprecated: Since L11A. Has no functional behaviour.

Condition: The counter is incremented when an uplink transmission from a


UE in true radio conditions is successfully received. To the subset of UEs
that are considered to be in true radio conditions are UEs for which CQI has
been received, are not buffer limited, not power limited and scheduled with
sufficient transport block size.
Counter type: ACC
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioThpVolDl
noNotification
nonPersistent The total successfully transferred data volume on MAC level in the
readOnly downlink. This counter includes possible padding bits.

Unit: 1 kilobit (1 000 bits)


Condition: The counter is incremented when a downlink transmission is
acknowledged on HARQ level.
Counter type: ACC
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioThpVolDlSCell
noNotification
nonPersistent The total successfully transferred data volume on MAC level in the downlink
readOnly for secondary cell traffic (i.e. the UE has another cell as its primary
component carrier (PCell)). This counter includes possible padding bits.

Unit: 1 kilobit (1 000 bits)

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 115 of 162

Filter: FDD
Condition: The counter is incremented when a downlink transmission is
acknowledged on HARQ level (only stepped for secondary component
carrier (SCell) traffic).
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioThpVolDlSelTbs
noNotification
nonPersistent The total successfully transferred data volume on MAC level in the downlink
readOnly for UEs that are considered to be in true radio condition. This counter
includes possible padding bits.

Unit: 1 kilobit (1 000 bits)


Deprecated: Since L11A. Has no functional behaviour.

Condition: The counter is incremented when a downlink transmission to a


UE in true radio condition is acknowledged on HARQ level. To the subset of
UEs that are considered to be in true radio conditions are UEs for which CQI
has been received, are not buffer limited and scheduled with sufficient
transport block size.
Counter type: ACC
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioThpVolUl
noNotification
nonPersistent The total successfully transferred data volume on MAC level in the uplink.
readOnly This counter includes possible padding bits.

Unit: 1 kilobit (1 000 bits)


Condition: The counter is incremented when an uplink transmission is
successfully received.
Counter type: ACC
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioThpVolUlSelTbs
noNotification
nonPersistent The total successfully transferred data volume on MAC level in the uplink
readOnly for UEs that are considered to be in true radio condition. This counter
includes possible padding bits.

Unit: 1 kilobit (1 000 bits)


Deprecated: Since L11A. Has no functional behaviour.

Condition: The counter is incremented when an uplink transmission from a


UE in true radio conditions is received, regardless of whether the reception
was successful or not. To the subset of UEs that are considered to be in
true radio conditions are UEs for which CQI has been received, are not
buffer limited, not power limited and scheduled with sufficient transport
block size.
Counter type: ACC
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..5] pmRadioTxRankDistr
nonUnique
noNotification The transmission mode / rank distributions gives more detailed information
nonPersistent on how much each transmission mode and rank is used.
readOnly

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 116 of 162

PDF ranges:
[0]: Transmit diversity
[1]: Open Loop SM Rank 1
[2]: Open Loop SM Rank 2
[3]: Closed Loop SM rank 1
[4]: Closed Loop SM rank 2

Condition: The corresponding sub-counter is stepped whenever a UE is


scheduled (new data transmission or retransmission). If the single antenna
port (port 0) is used, no samples will be collected.
Counter type: PDF
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..8] pmRadioUeOutLoopAdjDistr
nonUnique
noNotification Distribution of the outer loop adjustment.
nonPersistent
readOnly PDF ranges:
PDF ranges:
[0]: outer loop adjustment <= -7
[1]: -7 < outer loop adjustment <= -3
[2]: -3 < outer loop adjustment <= -1
[3]: -1 < outer loop adjustment <= 1
[4]: 1 < outer loop adjustment <= 3
[5]: 3 < outer loop adjustment <= 7
[6]: 7 < outer loop adjustment <= 10
[7]: 10 < outer loop adjustment

Unit: 1 dB

Condition: Each outer loop adjustment value per UE calculated on a TTI


basis yields one sample in the distribution.
Counter type: PDF
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqi2Subband0Sum
noNotification
nonPersistent The accumulated sum of all sub-band 0 CQI reported by UEs in the cell for
readOnly rank 2 transmissions. The average value of the reported sub-band 0 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqi2SubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 2 CQI report.
This counter is for rank 2 (two codewords) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15
Note for CQI/PMI/RI reporting mode 3-1 or 2-1, there will be a different
Sub-band CQI value for each codeword. In this case both CQI values shall
be added to the counter and are counted as two samples.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
pmRadioUeRepCqi2Subband10Sum

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 117 of 162

long The accumulated sum of all sub-band 10 CQI reported by UEs in the cell for
noNotification
nonPersistent rank 2 transmissions. The average value of the reported sub-band 10 CQI
readOnly within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqi2SubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 2 CQI report.
This counter is for rank 2 (two codewords) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15
Note for CQI/PMI/RI reporting mode 3-1 or 2-1, there will be a different
Sub-band CQI value for each codeword. In this case both CQI values shall
be added to the counter and are counted as two samples.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqi2Subband11Sum
noNotification
nonPersistent The accumulated sum of all sub-band 11 CQI reported by UEs in the cell for
readOnly rank 2 transmissions. The average value of the reported sub-band 11 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqi2SubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 2 CQI report.
This counter is for rank 2 (two codewords) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15
Note for CQI/PMI/RI reporting mode 3-1 or 2-1, there will be a different
Sub-band CQI value for each codeword. In this case both CQI values shall
be added to the counter and are counted as two samples.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqi2Subband12Sum
noNotification
nonPersistent The accumulated sum of all sub-band 12 CQI reported by UEs in the cell for
readOnly rank 2 transmissions. The average value of the reported sub-band 12 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqi2SubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 2 CQI report.
This counter is for rank 2 (two codewords) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15
Note for CQI/PMI/RI reporting mode 3-1 or 2-1, there will be a different
Sub-band CQI value for each codeword. In this case both CQI values shall
be added to the counter and are counted as two samples.

Counter type: ACC

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 118 of 162

Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqi2Subband1Sum
noNotification
nonPersistent The accumulated sum of all sub-band 1 CQI reported by UEs in the cell for
readOnly rank 2 transmissions. The average value of the reported sub-band 1 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqi2SubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 2 CQI report.
This counter is for rank 2 (two codewords) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15
Note for CQI/PMI/RI reporting mode 3-1 or 2-1, there will be a different
Sub-band CQI value for each codeword. In this case both CQI values shall
be added to the counter and are counted as two samples.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqi2Subband2Sum
noNotification
nonPersistent The accumulated sum of all sub-band 2 CQI reported by UEs in the cell for
readOnly rank 2 transmissions. The average value of the reported sub-band 2 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqi2SubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 2 CQI report.
This counter is for rank 2 (two codewords) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15
Note for CQI/PMI/RI reporting mode 3-1 or 2-1, there will be a different
Sub-band CQI value for each codeword. In this case both CQI values shall
be added to the counter and are counted as two samples.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqi2Subband3Sum
noNotification
nonPersistent The accumulated sum of all sub-band 3 CQI reported by UEs in the cell for
readOnly rank 2 transmissions. The average value of the reported sub-band 3 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqi2SubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 2 CQI report.
This counter is for rank 2 (two codewords) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15
Note for CQI/PMI/RI reporting mode 3-1 or 2-1, there will be a different

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 119 of 162

Sub-band CQI value for each codeword. In this case both CQI values shall
be added to the counter and are counted as two samples.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqi2Subband4Sum
noNotification
nonPersistent The accumulated sum of all sub-band 4 CQI reported by UEs in the cell for
readOnly rank 2 transmissions. The average value of the reported sub-band 4 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqi2SubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 2 CQI report.
This counter is for rank 2 (two codewords) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15
Note for CQI/PMI/RI reporting mode 3-1 or 2-1, there will be a different
Sub-band CQI value for each codeword. In this case both CQI values shall
be added to the counter and are counted as two samples.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqi2Subband5Sum
noNotification
nonPersistent The accumulated sum of all sub-band 5 CQI reported by UEs in the cell for
readOnly rank 2 transmissions. The average value of the reported sub-band 5 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqi2SubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 2 CQI report.
This counter is for rank 2 (two codewords) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15
Note for CQI/PMI/RI reporting mode 3-1 or 2-1, there will be a different
Sub-band CQI value for each codeword. In this case both CQI values shall
be added to the counter and are counted as two samples.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqi2Subband6Sum
noNotification
nonPersistent The accumulated sum of all sub-band 6 CQI reported by UEs in the cell for
readOnly rank 2 transmissions. The average value of the reported sub-band 6 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqi2SubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 2 CQI report.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 120 of 162

This counter is for rank 2 (two codewords) CQI reports.


The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15
Note for CQI/PMI/RI reporting mode 3-1 or 2-1, there will be a different
Sub-band CQI value for each codeword. In this case both CQI values shall
be added to the counter and are counted as two samples.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqi2Subband7Sum
noNotification
nonPersistent The accumulated sum of all sub-band 7 CQI reported by UEs in the cell for
readOnly rank 2 transmissions. The average value of the reported sub-band 7 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqi2SubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 2 CQI report.
This counter is for rank 2 (two codewords) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15
Note for CQI/PMI/RI reporting mode 3-1 or 2-1, there will be a different
Sub-band CQI value for each codeword. In this case both CQI values shall
be added to the counter and are counted as two samples.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqi2Subband8Sum
noNotification
nonPersistent The accumulated sum of all sub-band 8 CQI reported by UEs in the cell for
readOnly rank 2 transmissions. The average value of the reported sub-band 8 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqi2SubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 2 CQI report.
This counter is for rank 2 (two codewords) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15
Note for CQI/PMI/RI reporting mode 3-1 or 2-1, there will be a different
Sub-band CQI value for each codeword. In this case both CQI values shall
be added to the counter and are counted as two samples.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqi2Subband9Sum
noNotification
nonPersistent The accumulated sum of all sub-band 9 CQI reported by UEs in the cell for
readOnly rank 2 transmissions. The average value of the reported sub-band 9 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqi2SubbandSamp.
The counter is defined according to 32.425.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 121 of 162

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 2 CQI report.
This counter is for rank 2 (two codewords) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15
Note for CQI/PMI/RI reporting mode 3-1 or 2-1, there will be a different
Sub-band CQI value for each codeword. In this case both CQI values shall
be added to the counter and are counted as two samples.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqi2SubbandSamp
noNotification
nonPersistent The total sample count of rank 2 aperiodic CQI reported by UEs in the cell
readOnly within the measurement period. It is used to compute the average CQI
value for each sub-band.
The counter is defined according to 32.425.

Condition: Incremented for each UE aperiodic rank 2 CQI report within the
measurement period.
This counter is for rank 2 (two codewords) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Note for CQI/PMI/RI reporting mode 3-1 or 2-1, there will be a different
Sub-band CQI value for each codeword. In this case, the counter is
incremented twice.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..16] pmRadioUeRepCqiDistr
nonUnique
noNotification The reported CQI value from UEs in a distribution.
nonPersistent
readOnly PDF ranges:
[0]: CQI = 0
[1]: CQI = 1
[2]: CQI = 2
[3]: CQI = 3
[4]: CQI = 4
[5]: CQI = 5
[6]: CQI = 6
[7]: CQI = 7
[8]: CQI = 8
[9]: CQI = 9
[10]: CQI = 10
[11]: CQI = 11
[12]: CQI = 12
[13]: CQI = 13
[14]: CQI = 14
[15]: CQI = 15

Condition: The corresponding sub-counter is stepped whenever a CQI


report is received from a UE
Counter type: PDF

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 122 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long[0..16] pmRadioUeRepCqiDistr2
nonUnique
noNotification The reported CQI values related to rank 2 transmissions from UEs in a
nonPersistent distribution
readOnly
PDF ranges:
[0]: CQI = 0
[1]: CQI = 1
[2]: CQI = 2
[3]: CQI = 3
[4]: CQI = 4
[5]: CQI = 5
[6]: CQI = 6
[7]: CQI = 7
[8]: CQI = 8
[9]: CQI = 9
[10]: CQI = 10
[11]: CQI = 11
[12]: CQI = 12
[13]: CQI = 13
[14]: CQI = 14
[15]: CQI = 15

Condition: The corresponding sub-counter is stepped whenever a CQI


report related to a rank 2 transmission is received from a UE.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqiSubband0Sum
noNotification
nonPersistent The accumulated sum of all sub-band 0 CQI reported by UEs in the cell for
readOnly rank 1 transmissions. The average value of the reported sub-band 0 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqiSubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 1 CQI report.
This counter is for rank 1 (one codeword) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqiSubband10Sum
noNotification
nonPersistent The accumulated sum of all sub-band 10 CQI reported by UEs in the cell for
readOnly rank 1 transmissions. The average value of the reported sub-band 10 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqiSubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 1 CQI report.
This counter is for rank 1 (one codeword) CQI reports.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 123 of 162

The counter is defined according to 32.425 Section 4.10.1.2


Valid UE reported CQI values range from 0 to 15

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqiSubband11Sum
noNotification
nonPersistent The accumulated sum of all sub-band 11 CQI reported by UEs in the cell for
readOnly rank 1 transmissions. The average value of the reported sub-band 11 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqiSubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 1 CQI report.
This counter is for rank 1 (one codeword) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqiSubband12Sum
noNotification
nonPersistent The accumulated sum of all sub-band 12 CQI reported by UEs in the cell for
readOnly rank 1 transmissions. The average value of the reported sub-band 12 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqiSubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 1 CQI report.
This counter is for rank 1 (one codeword) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqiSubband1Sum
noNotification
nonPersistent The accumulated sum of all sub-band 1 CQI reported by UEs in the cell for
readOnly rank 1 transmissions. The average value of the reported sub-band 1 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqiSubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 1 CQI report.
This counter is for rank 1 (one codeword) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15

Counter type: ACC


Sampling rate: -

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 124 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long pmRadioUeRepCqiSubband2Sum
noNotification
nonPersistent The accumulated sum of all sub-band 2 CQI reported by UEs in the cell for
readOnly rank 1 transmissions. The average value of the reported sub-band 2 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqiSubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 1 CQI report.
This counter is for rank 1 (one codeword) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqiSubband3Sum
noNotification
nonPersistent The accumulated sum of all sub-band 3 CQI reported by UEs in the cell for
readOnly rank 1 transmissions. The average value of the reported sub-band 3 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqiSubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 1 CQI report.
This counter is for rank 1 (one codeword) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqiSubband4Sum
noNotification
nonPersistent The accumulated sum of all sub-band 4 CQI reported by UEs in the cell for
readOnly rank 1 transmissions. The average value of the reported sub-band 4 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqiSubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 1 CQI report.
This counter is for rank 1 (one codeword) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqiSubband5Sum
noNotification
The accumulated sum of all sub-band 5 CQI reported by UEs in the cell for
rank 1 transmissions. The average value of the reported sub-band 5 CQI

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 125 of 162

nonPersistent within the measurement period can be obtained in conjunction with counter
readOnly
pmRadioUeRepCqiSubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 1 CQI report.
This counter is for rank 1 (one codeword) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqiSubband6Sum
noNotification
nonPersistent The accumulated sum of all sub-band 6 CQI reported by UEs in the cell for
readOnly rank 1 transmissions. The average value of the reported sub-band 6 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqiSubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 1 CQI report.
This counter is for rank 1 (one codeword) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqiSubband7Sum
noNotification
nonPersistent The accumulated sum of all sub-band 7 CQI reported by UEs in the cell for
readOnly rank 1 transmissions. The average value of the reported sub-band 7 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqiSubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 1 CQI report.
This counter is for rank 1 (one codeword) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqiSubband8Sum
noNotification
nonPersistent The accumulated sum of all sub-band 8 CQI reported by UEs in the cell for
readOnly rank 1 transmissions. The average value of the reported sub-band 8 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqiSubbandSamp.
The counter is defined according to 32.425.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 126 of 162

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 1 CQI report.
This counter is for rank 1 (one codeword) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqiSubband9Sum
noNotification
nonPersistent The accumulated sum of all sub-band 9 CQI reported by UEs in the cell for
readOnly rank 1 transmissions. The average value of the reported sub-band 9 CQI
within the measurement period can be obtained in conjunction with counter
pmRadioUeRepCqiSubbandSamp.
The counter is defined according to 32.425.

Condition: Samples summed over the measurement period. One sample


per UE aperiodic rank 1 CQI report.
This counter is for rank 1 (one codeword) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2
Valid UE reported CQI values range from 0 to 15

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRadioUeRepCqiSubbandSamp
noNotification
nonPersistent The total sample count of rank 1 aperiodic CQI reported by UEs in the cell
readOnly within the measurement period. It is used to compute the average CQI
value for each sub-band.
The counter is defined according to 32.425.

Condition: Incremented for each UE aperiodic rank 1 CQI report within the
measurement period.
This counter is for rank 1 (one codeword) CQI reports.
The counter is defined according to 32.425 Section 4.10.1.2

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..2] pmRadioUeRepRankDistr
nonUnique
noNotification The reported rank distribution indicates the rank of UEs that are in a Open
nonPersistent and Closed Loop Spatial Multiplexing mode (where rank is reported).
readOnly
PDF ranges:
[0]: Rank = 1
[1]: Rank = 2

Condition: The corresponding sub-counter is stepped whenever a rank


report is received from a UE
Counter type: PDF
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRaFailCbraMsg2Disc
noNotification

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 127 of 162

nonPersistent The number of CBRA preambles for which no random access response (RA
readOnly
Msg2) was sent due to expiration of the random access response window.

Condition: This counter should be incremented when the RA response


window expires before an RA response has been sent for a detected CBRA
preamble.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRaFailCfraMsg2Disc
noNotification
nonPersistent The number of CFRA preambles for which no random access response (RA
readOnly Msg2) was sent due to expiration of the random access response window.

Condition: This counter should be incremented when the RA response


window expires before an RA response has been sent for a detected CFRA
preamble.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRaSuccCbra
noNotification
nonPersistent The number of successfully detected RA Msg3 for CBRA
readOnly

Condition: This counter should be incremented when an RA msg3 is


successfully detected (i.e. when the CRC is OK) in the Cell.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRaSuccCfra
noNotification
nonPersistent The number of successfully completed CFRA procedures. Measured when
readOnly first UL-SCH message is received after detection of the CFRA preamble.

Condition: This counter should be incremented when an UL-SCH message is


successfully detected after a CFRA preamble has been received.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRaSuccSrInSync
noNotification
nonPersistent The total number of received Scheduling Requests on RACH from In-Synch
readOnly UEs.

Condition: The counter aggregates the number of received scheduling


requests on RACH. The counter is stepped only for Ues that were In Synch
prior to the RACH and were not part of a handover procedure.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRaSuccSrOutOfSync
noNotification
nonPersistent The total number of received Scheduling Request on RACH from Out-Of-
readOnly Synch UEs.

Condition: The counter is increased every time a raMsg3 is received for a


UE when all of the following conditions are met: 1) The UE was outOfSynch
prior to the random access transmission. 2) The UE has data in its
transmission buffer. 3) The RACH procedure was not part of a handover
procedure.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 128 of 162

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..12] pmRaSuccTa
nonUnique
noNotification Distribution of the measured Timing Advance value at random access.
nonPersistent
readOnly PDF ranges:
[0]: [0..9]%,
[1]: [10..19]%,
[2]: [20..29]%,
[3]: [30..39]%,
[4]: [40..49]%,
[5]: [50..59]%,
[6]: [60..69]%,
[7]: [70..79]%,
[8]: [80..89]%,
[9]: [90..99]%,
[10]: [100..109]%,
[11]: [110..200]%

Condition: When a successful random is done (RA Msg3 received) the


counter covering the measured TA shall be incremented. Example: When a
sample is measured at 50% it means that a successfull random acces has
been done at 50% of the configured cell range. In this case bin 6 for the
range 50..59% shall be increased.
Counter type: PDF
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRateShapeTimeUl
noNotification
nonPersistent The time where the UE have uplink data in a buffer and End-user bitrate
readOnly shaping functionality will prohibit transmission in the uplink.

Unit: 1 ms
Condition: Data in uplink buffer, according to the Buffer Status Report
(BSR) and Token Bucket Counter (TBC) less than 0. Continuous
measurement for UEs aggregated to cell level.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRaUnassignedCfraFalse
noNotification
nonPersistent The number of detected Contention Free Random Access (CFRA, known as
readOnly non-contention based random access in 3GPP term) preambles that are not
allocated to any UE

Condition: This counter should be incremented when an RA msg 1 is


received by eNB with a CFRA preamble which is not allocated to any UE.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRaUnassignedCfraSum
noNotification
nonPersistent The total number of unassigned Contention Free Random Access (CFRA,
readOnly known as non-contention based random access in 3GPP term) preambles at
each PRACH occasion during the reporting period.

Condition: This counter should be incremented at each PRACH occasion by

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 129 of 162

the number of unassigned CFRA preambles at that given PRACH occasion


during the reporting period.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRlcArqDlAck
noNotification
nonPersistent The total number of successful RLC PDU transmissions (ACKs) in the
readOnly downlink direction.

When carrier aggregation is used, the total number of successful RLC PDU
transmissions (ACKs) in the downlink direction is registered on the UE's
primary component carrier (PCell).

Filter: FDD
Condition: Continuous measurement for Radio Bearers aggregated to cell
level.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRlcArqDlNack
noNotification
nonPersistent The total number of unsuccessful RLC PDU and RLC PDU segment
readOnly transmissions (NACKs) in the downlink direction.

When carrier aggregation is used, the total number of unsuccessful RLC


PDU and RLC PDU segment transmissions (NACKs) in the downlink direction
is registered on the UE's primary component carrier (PCell).

Filter: FDD
Condition: Continuous measurement for Radio Bearers aggregated to cell
level.
Counter type: ACC
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRlcArqUlAck
noNotification
nonPersistent The total number of successful RLC PDU transmissions (ACKs) in the uplink
readOnly direction.

Condition: Continuous measurement for Radio Bearers aggregated to cell


level.
Counter type: ACC
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRlcArqUlNack
noNotification
nonPersistent The total number of unsuccessful RLC PDU and RLC PDU segment
readOnly transmissions (NACKs) in the uplink direction.

Condition: Continuous measurement for Radio Bearers aggregated to cell


level.
Counter type: ACC
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRlcDelayPktTransDl
noNotification
nonPersistent Number of samples for RLC delay measurements.
readOnly

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 130 of 162

Condition: Continuous measurement for UEs aggregated to cell level.


Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmRlcDelayPktTransDlQci
nonUnique
noNotification Number of samples for DL RLC delay measurements during a measurement
nonPersistent period per QCI.
readOnly
Compressed: True

Condition: The counter registers the number of samples for DL delay


measurements during a measurement period per QCI.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRlcDelayTimeDl
noNotification
nonPersistent Aggregated time for the downlink RLC delay measure.
readOnly
Unit: 1 ms
Condition: The time for each sample shall show the time between reception
of a PDCP SDU until it is scheduled and sent to the MAC layer for
transmission over the air. Only applicable to DRB packets
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmRlcDelayTimeDlQci
nonUnique
noNotification Aggregated DL RLC delay for a measurement period per QCI.
nonPersistent
readOnly Compressed: True

Unit: 1 ms

Condition: The counter represents DL delay per QCI. The DL delay is the
time between reception of a PDCP SDU until it has been scheduled and sent
to the MAC layer for transmission over the air.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRohcEstabFailCid
noNotification
nonPersistent Number of setups of Robust Header Compression failed due to BBM limit.
readOnly
Condition: Triggered at failed activation of Robust Header Compression for
a data radio bearer.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRohcEstabFailLic
noNotification
nonPersistent Number of setups Robust Header Compression failed due to missing or
readOnly inoperable license.

Condition: Triggered at failed activation of Robust Header Compression for


a data radio bearer.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 131 of 162

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRohcEstabFailUeCap
noNotification
nonPersistent Number of setups Robust Header Compression failed due UE Capabilities
readOnly
Condition: Triggered at failed activation of Robust Header Compression for
a data radio bearer.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnEstabAtt
noNotification
nonPersistent The total number of RRC Connection Request attempts.
readOnly

Condition: Stepped at reception of RRC message RRC Connection Request.


Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long pmRrcConnEstabAttDta
noNotification
nonPersistent The total number of RRC Connection Request attempts with Establishment
readOnly Cause Delay Tolerant Access.

Condition: Stepped at reception of every RRC message RRC Connection


Request with Establishment Cause Delay Tolerant Access.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmRrcConnEstabAttEm
noNotification
nonPersistent The total number of RRC Connection Request attempts with establishment
readOnly cause emergency.

Condition: Stepped at reception of RRC message RRC Connection Request


with establishment cause emergency.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnEstabAttHpa
noNotification
nonPersistent The total number of RRC Connection Request attempts with establishment
readOnly cause highPriorityAccess

Condition: Stepped at reception of RRC message RRC Connection Request


with establishment cause highPriorityAccess
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnEstabAttMod
noNotification
nonPersistent The total number of RRC Connection Request attempts with Establishment
readOnly cause Mobile Originating Data.

Condition: Stepped at reception of RRC message RRC Connection Request


with Establishment cause Mobile Originating Data.
Counter type: PEG

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 132 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long pmRrcConnEstabAttMos
noNotification
nonPersistent The total number of RRC Connection Request attempts with Establishment
readOnly cause Mobile Originating Signaling.

Condition: Stepped at reception of RRC message RRC Connection Request


with Establishment cause Mobile Originating Signaling.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnEstabAttMta
noNotification
nonPersistent The total number of RRC Connection Request attempts with Establishment
readOnly cause Mobile Terminating Access.

Condition: Stepped at reception of RRC message RRC Connection Request


with Establishment cause Mobile Terminating Access.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnEstabAttReatt
noNotification
nonPersistent The total number of RRC Connection Request attempts that are considered
readOnly as re-attempts.

Condition: Stepped at reception of RRC message RRC Connection Request


while an RRC Connection Setup is already ongoing for that S-TMSI.
Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long pmRrcConnEstabAttReattDta
noNotification
nonPersistent The total number of RRC Connection Request attempts that are considered
readOnly as re-attempts for Establishment Cause Delay Tolerant Access.

Condition: Stepped at reception of RRC message RRC Connection Setup


Complete if the corresponding RRC Connection Request had Establishment
Cause Delay Tolerant Access AND while an RRC Connection Setup is already
ongoing for that S-TMSI.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmRrcConnEstabAttReattEm
noNotification
nonPersistent The total number of RRC Connection Request attempts that are considered
readOnly as re-attempts for Establishment cause Emergency.

Condition: Stepped at reception of RRC message RRC Connection Setup


Complete if the corresponding RRC Connection Request had Establishment
cause Emergency AND while an RRC Connection Setup is already ongoing
for that S-TMSI.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnEstabAttReattHpa
noNotification

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 133 of 162

nonPersistent The total number of RRC Connection Request attempts that are considered
readOnly
as re-attempts for Establishment cause High Priority Access.

Condition: Stepped at reception of RRC message RRC Connection Setup


Complete if the corresponding RRC Connection Request had Establishment
cause High Priority Access AND while an RRC Connection Setup is already
ongoing for that S-TMSI.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnEstabAttReattMod
noNotification
nonPersistent The total number of RRC Connection Request attempts that are considered
readOnly as re-attempts for Establishment cause Mobile Originating Data.

Condition: Stepped at reception of RRC message RRC Connection Setup


Complete if the corresponding RRC Connection Request had Establishment
cause Mobile Originating Data AND while an RRC Connection Setup is
already ongoing for that S-TMSI.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnEstabAttReattMos
noNotification
nonPersistent The total number of RRC Connection Request attempts that are considered
readOnly as re-attempts for Establishment cause Mobile Originating Signaling.

Condition: Stepped at reception of RRC message RRC Connection Setup


Complete if the corresponding RRC Connection Request had Establishment
cause Mobile Originating Signaling AND while an RRC Connection Setup is
already ongoing for that S-TMSI.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnEstabAttReattMta
noNotification
nonPersistent The total number of RRC Connection Request attempts that are considered
readOnly as re-attempts for Establishment cause Mobile Terminating Access.

Condition: Stepped at reception of RRC message RRC Connection Setup


Complete if the corresponding RRC Connection Request had Establishment
cause Mobile Terminating Access AND while an RRC Connection Setup is
already ongoing for that S-TMSI.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnEstabFailBearerAdmissionRej
noNotification
nonPersistent The total number of failed establishment of RRC Connection due to the fact
readOnly that all the UE's bearers are rejected during bearer admission.

Condition: Stepped for each UE that fails to establish an RRC Connection


due to the fact that the all the UE's bearers are rejected during bearer
admission.

Counter type: PEG


Sampling rate: -

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 134 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long pmRrcConnEstabFailHighLoad
noNotification
nonPersistent The total number of failed RRC Connection Establishments due to high load.
readOnly
Condition: Stepped at transmission of RRC message RRC Connection Reject
when Load Control function in the RBS indicates that the load is too high.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnEstabFailLic
noNotification
nonPersistent The total number of failed RRC Connection Establishments due to lack of
readOnly connected users license.

Condition: Stepped at transmission of RRC message RRC Connection Reject


due to lack of connected users license.
Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long pmRrcConnEstabFailOverload
noNotification
nonPersistent The total number of failed RRC Connection Establishments due to overload.
readOnly
Condition: Stepped at transmission of RRC message RRC Connection Reject
when Load Control function in the RBS indicates overload.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnEstabSucc
noNotification
nonPersistent The total number of successful RRC Connection Establishments.
readOnly

Condition: Stepped at reception of RRC message RRC Connection Setup


Complete.
Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long pmRrcConnEstabSuccDta
noNotification
nonPersistent The total number of successful RRC Connection Establishments for
readOnly Establishment Cause Delay Tolerant Access.

Condition: Stepped at reception of RRC message RRC Connection Setup


Complete if the corresponding RRC Connection Request had Establishment
Cause Delay Tolerant Access.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmRrcConnEstabSuccEm
noNotification
nonPersistent The total number of successful RRC Connection Establishments for
readOnly Establishment cause Emergency.

Condition: Stepped at reception of RRC message RRC Connection Setup


Complete if the corresponding RRC Connection Request had Establishment
cause Emergency
Counter type: PEG

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 135 of 162

Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnEstabSuccGummeiNative
noNotification
nonPersistent The total number of successful RRC Connection Establishments for GUMMEI
readOnly type equal to native.

Condition: Stepped at reception of every RRC message RRC Connection


Setup Complete indicating GUMMEI type equal to native.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmRrcConnEstabSuccHpa
noNotification
nonPersistent The total number of successful RRC Connection Establishments for
readOnly Establishment cause High Priority.

Condition: Stepped at reception of RRC message RRC Connection Setup


Complete if the corresponding RRC Connection Request had Establishment
cause High Priority.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnEstabSuccMod
noNotification
nonPersistent The total number of successful RRC Connection Establishments for
readOnly Establishment cause Mobile Originating Data.

Condition: Stepped at reception of RRC message RRC Connection Setup


Complete if the corresponding RRC Connection Request had Establishment
cause Mobile Originating Data.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnEstabSuccMos
noNotification
nonPersistent The total number of successful RRC Connection Establishments for
readOnly Establishment cause Mobile Originating Signaling.

Condition: Stepped at reception of RRC message RRC Connection Setup


Complete if the corresponding RRC Connection Request had Establishment
cause Mobile Originating Signaling.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnEstabSuccMta
noNotification
nonPersistent The total number of successful RRC Connection Establishments for
readOnly Establishment cause Mobile Terminating Access.

Condition: Stepped at reception of RRC message RRC Connection Setup


Complete if the corresponding RRC Connection Request had Establishment
cause Mobile Terminating Access.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
pmRrcConnLevSamp

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 136 of 162

long Number of times the corresponding Sum counter has been incremented.
noNotification
nonPersistent Associated ACC pmCounter pmRrcConnLevSum.
readOnly

Condition: The counter is increased at every occasion when the


corresponding sum counter is increased.
Counter type: SCAN
Sampling rate: 5 seconds
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnLevSum
noNotification
nonPersistent Sum of all sample values recorded for "number of UEs in RRC_CONNECTED
readOnly mode".

Condition: This counter is based on an internal level counter maintaining


the current number of UEs in RRC_CONNECTED mode. Values are read
periodically and accumulated.
Counter type: ACC
Sampling rate: 5 seconds
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnLevSumUlOutOfSync
noNotification
nonPersistent The number of UEs in RRC_CONNECTED that have UL sync state 'out-of-
readOnly sync'.

Condition: This counter is based on an internal level counter that counts the
number of RRC_CONNECTED UEs that have UL synchronization state: out-
of-sync. Values are read periodically and accumulated.
Counter type: ACC
Sampling rate: 5
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnMax
noNotification
nonPersistent Peak number of UE in RRC_CONNECTED mode.
readOnly

Condition: This counter is based on an internal level counter maintained by


eNB. The internal level counter maintains the current number of UEs in
RRC_CONNECTED mode. pmRrcConnMax is updated at end of ROP with the
max value during the ROP period.
Counter type: Gauge
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnReconfAttNoMob
noNotification
nonPersistent Number of RRC connection reconfiguration attempts (excluding attempt
readOnly done for mobility purpose).

Condition: At the transmission of RRCConnectionReconfiguration message


and it does not include the mobilityControlInfo.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnReconfSuccNoMob
noNotification
nonPersistent Successful number of RRC connection reconfiguration attempts (excluding
readOnly attempt done for mobility purpose).

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 137 of 162

Condition: When RRCConnectionReconfigurationComplete is received


succeeding transmission of RRCConnectionReconfiguration message that
did not include the mobilityControlInfo.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnReestAtt
noNotification
nonPersistent The number of RRC Connection Reestablishment attempts.
readOnly
Condition: A RRC Connection Reestablishment Request message is
received.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnReestAttHo
noNotification
nonPersistent The number of RRC Connection Reestablishments attempted during an
readOnly ongoing handover

Condition: An RRCConnectionReestablishmentRequest message is received


by an UE for which there is an ongoing handover.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnReestFailLicMtReest
noNotification
nonPersistent The number of RRC Connection Reestablishments attempts that failed due
readOnly to feature "Multi-Target RRC Connection Reestablishment" not being
OPERABLE

Condition: The RRC Connection Reestablishment (attempted during an


ongoing handover or in an unprepared cell) fails for this UE due to the
serviceState value is INOPERABLE for the optional feature "Multi-Target
RRC Connection Reestablishment"
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnReestSucc
noNotification
nonPersistent The number of successful RRC Connection Reestablishments.
readOnly
Condition: A RRC Connection Reestablishment Complete messages is
received.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnReestSuccHo
noNotification
nonPersistent The number of successful RRC Connection Reestablishments attempted
readOnly during an ongoing handover

Condition: An RRCConnectionReestablishmentRequest message is received


by an UE for which there is an ongoing handover and the reestablishment
procedure is successfully completed for the UE.
Counter type: PEG
Sampling rate: -

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 138 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long pmRrcConnTuneOutLevSamp
noNotification
nonPersistent Number of times the corresponding Sum counter has been incremented.
readOnly Associated ACC pmCounter pmRrcConnTuneOutLevSum.

Condition: The counter is increased at every occasion when the


corresponding sum counter is increased.
Counter type: SCAN
Sampling rate: 5 seconds
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmRrcConnTuneOutLevSum
noNotification
nonPersistent Sum of all sample values recorded for "number of Tune-out UEs in
readOnly RRC_CONNECTED mode".

Condition: This counter is based on an internal level counter maintaining


the current number of Tune-out UEs in RRC_CONNECTED mode. Values are
read periodically and accumulated.

Counter type: ACC


Sampling rate: 5 seconds
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmS1SigConnEstabAtt
noNotification
nonPersistent This measurement provides the number of S1 Signalling connection
readOnly establishment attempts for any establishment cause.

Condition: Stepped at transmission of Initial UE message.


Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long pmS1SigConnEstabAttDta
noNotification
nonPersistent This measurement provides the number of S1 Signalling connection
readOnly establishment attempts with RRC Connection Request Establishment cause
Delay Tolerant Access.

Condition: Stepped at transmission of Initial UE message with RRC


Connection Request Establishment cause Delay Tolerant Access.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmS1SigConnEstabAttEm
noNotification
nonPersistent This measurement provides the number of S1 Signalling connection
readOnly establishment attempts with RRC Connection Request Establishment cause
Emergency.

Condition: Stepped at transmission of Initial UE message with RRC


Connection Request Establishment cause Emergency.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmS1SigConnEstabAttHpa
noNotification

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 139 of 162

nonPersistent This measurement provides the number of S1 Signalling connection


readOnly
establishment attempts with RRC Connection Request Establishment cause
High Priority Access.

Condition: Stepped at transmission of Initial UE message with RRC


Connection Request Establishment cause High Priority Access.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmS1SigConnEstabAttMod
noNotification
nonPersistent This measurement provides the number of S1 Signalling connection
readOnly establishment attempts with RRC Connection Request Establishment cause
Mobile Originating Data.

Condition: Stepped at transmission of Initial UE message with RRC


Connection Request Establishment cause Mobile Originating Data.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmS1SigConnEstabAttMos
noNotification
nonPersistent This measurement provides the number of S1 Signalling connection
readOnly establishment attempts with RRC Connection Request Establishment cause
Mobile Originating Signalling.

Condition: Stepped at transmission of Initial UE message with RRC


Connection Request Establishment cause Mobile Originating Signalling.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmS1SigConnEstabAttMta
noNotification
nonPersistent This measurement provides the number of S1 Signalling connection
readOnly establishment attempts with RRC Connection Request Establishment cause
Mobile Terminating Access.

Condition: Stepped at transmission of Initial UE message with RRC


Connection Request Establishment cause Mobile Terminating Access.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmS1SigConnEstabSucc
noNotification
nonPersistent The total number of successful S1 signalling connection establishments.
readOnly

Condition: Stepped at the first occurrence of reception of any message on


this S1 logical connection.
Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long pmS1SigConnEstabSuccDta
noNotification
nonPersistent The total number of successful S1 signalling connection establishments with
readOnly Establishment cause Delay Tolerant Access.

Condition: Stepped at the first occurrence of reception of any message on


this S1 logical connection, if the RRC Connection Request Establishment

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 140 of 162

cause was Delay Tolerant Access.


Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmS1SigConnEstabSuccEm
noNotification
nonPersistent The total number of successful S1 signalling connection establishments with
readOnly Establishment cause Emergency.

Condition: Stepped at the first occurrence of reception of any message on


this S1 logical connection, if the RRC Connection Request Establishment
cause was Establishment cause Emergency.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmS1SigConnEstabSuccHpa
noNotification
nonPersistent The total number of successful S1 signalling connection establishments with
readOnly Establishment cause High Priority Access.

Condition: Stepped at the first occurrence of reception of any message on


this S1 logical connection, if the RRC Connection Request Establishment
cause was Establishment cause High Priority Access.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmS1SigConnEstabSuccMod
noNotification
nonPersistent The total number of successful S1 signalling connection establishments with
readOnly Establishment cause Mobile Originating Data.

Condition: Stepped at the first occurrence of reception of any message on


this S1 logical connection, if the RRC Connection Request Establishment
cause was Establishment cause Mobile Originating Data.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmS1SigConnEstabSuccMos
noNotification
nonPersistent The total number of successful S1 signalling connection establishments with
readOnly Establishment cause Mobile Originating Signalling.

Condition: Stepped at the first occurrence of reception of any message on


this S1 logical connection, if the RRC Connection Request Establishment
cause was Establishment cause Mobile Originating Signalling.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmS1SigConnEstabSuccMta
noNotification
nonPersistent The total number of successful S1 signalling connection establishments with
readOnly Establishment cause Mobile Terminating Access.

Condition: Stepped at the first occurrence of reception of any message on


this S1 logical connection, if the RRC Connection Request Establishment
cause was Establishment cause Mobile Terminating Access.
Counter type: PEG
Sampling rate: -

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 141 of 162

Scanner: Primary
Counter is reset after measurement period: Yes
long pmSchedActivityCellDl
noNotification
nonPersistent The aggregated number of ms in which DRB data was required to be
readOnly scheduled in the downlink.

Unit: 1 ms
Condition: Each TTI, the counter shall be incremented when there was a
need to schedule DRB data in the downlink.
Counter type: PEG
Sampling rate: Per ms
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmSchedActivityCellUl
noNotification
nonPersistent The aggregated number of ms in which DRB data was required to be
readOnly scheduled in the uplink.

Unit: 1 ms
Condition: Each TTI, the counter shall be incremented when there was a
need to schedule DRB data in the uplink.
Counter type: PEG
Sampling rate: Per ms
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmSchedActivityUeDl
noNotification
nonPersistent Total UEs scheduling activity in the downlink.
readOnly
Unit: 1 ms
Condition: The counter shall be increased with 1 for each UE that was
scheduled with SRB/DRB data in the downlink.
Counter type: ACC
Sampling rate: Per TTI
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmSchedActivityUeUl
noNotification
nonPersistent Total UEs scheduling activity in the uplink.
readOnly
Unit: 1 ms
Condition: The counter shall be increased with 1 for each UE that was
scheduled with SRB/DRB data in the uplink.
Counter type: ACC
Sampling rate: Per TTI
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmSchedRestrictUeCatDl
noNotification
nonPersistent The sum of the contributions from each UE of the number of ms where
readOnly respective UE is limited in the downlink direction by its UE capability.

Unit: 1 ms
Condition: Each TTI, the counter shall be increased by the number of UEs in
the cell that are limited by their UE capability.
Counter type: ACC
Sampling rate: Per TTI
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmSchedRestrictUeCatUl
noNotification

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 142 of 162

nonPersistent The sum of the contributions from each UE of the number of ms where
readOnly
respective UE is limited in the uplink direction by its UE capability.

Unit: 1 ms
Condition: Each TTI, the counter shall be increased by the number of UEs in
the cell that are limited by their UE capability.
Counter type: ACC
Sampling rate: Per TTI
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmServiceTimeDrb
noNotification
nonPersistent Number of service seconds aggregated for DRBs in a cell. A DRB is said to
readOnly be ´in service´ from the first data on a DRB (UL or DL) until the last on the
DRB is sent/received.

Unit: 1 s
Condition: Count the time from the first data on the DRB until the last data
on the DRB and sum on the cell level.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmServiceTimeDrbQci
nonUnique
noNotification Number of service seconds aggregated for DRBs mapping to a specific QCI
nonPersistent in a cell. A DRB is said to be ´in service´ from the first data on a DRB (UL
readOnly or DL) until the last on the DRB is sent/received.

[0]: N/A
[1]: Service Time for DRBs mapping to QCI 1
...
[255]: Service Time for DRBs mapping to QCI 255

Compressed: True

Unit: 1 s

Condition: Count the time from the first data on the DRB until the last data
on the DRB associated with the specific QCI and sum on the cell level.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmServiceTimeUe
noNotification
nonPersistent Number of service seconds aggregated for UEs in a cell. A UE is said to be
readOnly ´in service´ if any of its associated DRBs are.

Unit: 1 s
Condition: Count the time when any DRB, associated with the UE, is in
service.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmSessionTimeDrb
noNotification
nonPersistent This counters shows the accumulated active session time for all DRBs in a
readOnly cell.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 143 of 162

Unit: 1 seconds
Condition: Number of session seconds aggregated for DRBs in a cell. A DRB
is said to be ´in session´ if data on a DRB (UL or DL) has been transferred
during the last 100 ms.
Counter type: ACC
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..256] pmSessionTimeDrbQci
nonUnique
noNotification The session time aggregated for DRBs mapping to a QCI.
nonPersistent Compressed: True
readOnly
Unit: 1 seconds

Condition: The bin accumulates session seconds aggregated for DRBs with
a certain QCI. The DRBs for a UE is said to be "in session" if any data on
any DRB (UL or DL) has been transferred during the last 100 ms for that
QCI.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmSessionTimeUe
noNotification
nonPersistent This counters shows the accumulated active session time for all UEs in a
readOnly cell.

Unit: 1 s
Condition: Number of session seconds aggregated for all UEs in a cell. A UE
is said to be ´in session´ if any data on a DRB (UL or DL) has been
transferred during the last 100 ms
Counter type: ACC
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long[0..8] pmSinrPucchDistr
nonUnique
noNotification Distribution of the SINR values calculated for PUCCH .
nonPersistent
readOnly PDF ranges:
[0]: SINR <= -15
[1]: -15 < SINR <= -12
[2]: -12 < SINR <= -9
[3]: -9 < SINR <= -6
[4]: -6 < SINR <= -3
[5]: -3 < SINR <= 0
[6]: 0 < SINR <= 3
[7]: 3 < SINR

Unit: 1 dB

Condition: Each SINR value for PUCCH per UE calculated on a TTI basis
yields one sample in the distribution.
Counter type: PDF
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..8] pmSinrPuschDistr
nonUnique

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 144 of 162

noNotification Distribution of the SINR values calculated for PUSCH .


nonPersistent
readOnly
PDF ranges:
[0]: SINR <= -5
[1]: -5 < SINR <= -2
[2]: -2 < SINR <= 2
[3]: 2 < SINR <= 6
[4]: 6 < SINR <= 10
[5]: 10 < SINR <= 14
[6]: 14 < SINR <= 17
[7]: 17 < SINR

Unit: 1 dB

Condition: Each SINR value for PUSCH per UE calculated on a TTI basis
yields one sample in the distribution.
Counter type: PDF
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmTtiBundlingUeMax
noNotification
nonPersistent Maximum sample value of number of UEs using TTI Bundling.
readOnly
Filter: FDD
Condition: The counter is set to the peak value of samples of number of
UEs using TTI Bundling.
Counter type: GAUGE
Sampling rate: 5
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmTtiBundlingUeSamp
noNotification
nonPersistent Counts the number of times the corresponding pmTtiBundlingUeSum has
readOnly accumulated a new sample.

Filter: FDD
Condition: The counter is incremented by one each time a sample value is
accumulated in pmTtiBundlingUeSum.
Counter type: SCAN
Sampling rate: 5
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmTtiBundlingUeSum
noNotification
nonPersistent Sum of all sample values recorded for number of UEs using TTI Bundling.
readOnly
Filter: FDD
Condition: The counter accumulates values of the number of UEs using TTI
Bundling from each sampling occasion.
Counter type: ACC
Sampling rate: 5
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..5] pmUeCategoryDistr
nonUnique
noNotification A distribution of the UE capability parameter UeCategory for established UE
nonPersistent contexts.
readOnly
PDF ranges:
[0]: ueCategory = 1
[1]: ueCategory = 2

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 145 of 162

[2]: ueCategory = 3
[3]: ueCategory = 4
[4]: ueCategory = 5

Condition: At each UE context establishment, one UeCategory parameter


value yields one sample in the ditribution.
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtEstabAtt
noNotification
nonPersistent The total number of Initial Context Setup Establishment attempts.
readOnly

Condition: Stepped for each S1 message Initial Context Setup Request.


Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtEstabSucc
noNotification
nonPersistent The total number of Initial Context Setup Establishment successes
readOnly
Condition: Stepped for each Initial Context that is successfully established.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelAbnormalEnb
noNotification
nonPersistent
readOnly Condition: Stepped at reception of S1 message UE Context Release
Command with internal cause codes considered abnormal (Radio
Connection with UE is lost; Handover failure for the UE; UE pre-emption)
when the RBS initiated the release. It can also be stepped at transmission
of UE Context Release Request or Reset message by the RBS, or when a
cell owned by that RBS is disabled (and that leads to internal RBS UE
Context Release).
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelAbnormalEnbAct
noNotification
nonPersistent The total number of abnormal UE Contexts Releases initiated by the RBS
readOnly and that there was data in either the UL or DL buffer (i.e. active).

Condition: If there was data in the buffer at the time of release, then at
reception of S1 message UE Context Release Command with internal cause
codes considered abnormal (Radio Connection with UE is lost; Handover
failure for the UE; UE pre-emption) when the RBS initiated the release. It
can also be stepped at transmission of UE Context Release Request or
Reset message by the RBS, or when a cell owned by that RBS is disabled
(and that leads to internal RBS UE Context Release).
Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long pmUeCtxtRelAbnormalEnbActCdt
noNotification
nonPersistent Counts the total number of abnormal UE context releases by the eNodeB
readOnly due to cell down time (manual intervention) when data was in either the UL
or DL buffer (i.e. active).

Condition: Stepped for each UE that is lost due to cell down time (manual
intervention).

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 146 of 162

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelAbnormalEnbActHo
noNotification
nonPersistent The total number of abnormal UE Context Releases initiated by the eNB due
readOnly to handover execution failure and that there was data in either the UL or DL
buffer (i.e. active).

Condition: If there was data in the buffer at the time of release, and the
release is due to that executed handover fails and the UE is considered
dropped.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelAbnormalEnbActPe
noNotification
nonPersistent The total number of abnormal UE context releases initiated by the RBS due
readOnly to pre-emption and that there was data in either the UL or DL buffer (i.e.
active).

Condition: Stepped for each UE that is released due to to pre-emption when


data was in either the UL or DL buffer.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelAbnormalEnbActTnFail
noNotification
nonPersistent The total number of abnormal UE Context releases initiated by the eNB due
readOnly to S1 interface down, S1 bearer error indication, and SGW failure detection,
and that there was data in either the UL or DL buffer (i.e. active).

Condition: If there was data in the buffer at the time of release of an E-RAB
and due to that the S1 interface is lost, S1 bearer error indication is
received or SGW failure is detected.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelAbnormalEnbActUeLost
noNotification
nonPersistent The total number of abnormal UE Context releases by the RBS due that the
readOnly radio connection with the UE is lost and that there was data in either the UL
or DL buffer (i.e. active).

Condition: If there was data in the buffer at the time of release and if there
was a release of an UE due to that the radio connection towards the UE is
lost (i.e. UE unreachable by the RBS).
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelAbnormalEnbLic
noNotification
nonPersistent The total number of abnormal UE Contexts Releases initiated by the RBS
readOnly due to license reject.

Condition: Stepped at reception of S1 message UE Context Release


Command when internal cause codes considered abnormal (license Limited
Service Mode Emergency Call Support is not operable) when the RBS
initiated the release.
Counter type: PEG

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 147 of 162

Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelAbnormalEnbPe
noNotification
nonPersistent The total number of abnormal UE Context releases initiated by the RBS due
readOnly to pre-emption. The counter is stepped regardless of whether data was or
was not lost in UL/DL buffers.

Condition: Stepped for each UE that is released due to to pre-emption.


Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelAbnormalEnbTuneOut
noNotification
nonPersistent The total number of abnormal UE Contexts Releases for Tune-out UEs
readOnly initiated by the RBS. The counter is stepped regardless of whether data was
or was not lost in UL/DL buffers.

Condition: Stepped at reception of S1 message UE Context Release


Command with internal cause codes considered abnormal (Radio
Connection with UE is lost; Handover failure for the UE; UE pre-emption)
when the RBS initiated the release. It can also be stepped at transmission
of UE Context Release Request or Reset message by the RBS, or when a
cell owned by that RBS is disabled (and that leads to internal RBS UE
Context Release). Stepped in case UE type is Tune-out
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelAbnormalMmeAct
noNotification
nonPersistent The total number of UE Context Releases initiated by the MME with a cause
readOnly regarded as abnormal and that there was data in either the UL or DL buffer
(i.e. active).

Condition: there was data in the buffer at the time of release, then stepped
at reception of S1 message UE Context Release Command , if the cause
was regarded as abnormal, and the release is MME initiated.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmUeCtxtRelCsfbCdma1xRtt
noNotification
nonPersistent Number of RRC Connection Release with redirect to CDMA2000 1xRTT
readOnly triggered by CS Fallback

Condition: A CS Fallback attempt is performed towards a CDMA2000 1xRTT


Carrier Frequency defined as a RRC Connection Release with redirect
information, due to a received CS Fallback Indicator set to CS Fallback in
Initial Context Setup Request or UE Context Modification Request.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmUeCtxtRelCsfbCdma1xRttEm
noNotification
nonPersistent Number of RRC Connection Release with redirect to CDMA2000 1xRTT
readOnly triggered by CS Fallback Emergency

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 148 of 162

Condition: A CS Fallback attempt is performed towards a CDMA2000 1xRTT


Carrier Frequency defined as a RRC Connection Release with redirect
information, due to a received CS Fallback Indicator set to CS Fallback High
Priority in Initial Context Setup Request or UE Context Modification
Request.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmUeCtxtRelCsfbGsm
noNotification
nonPersistent The number of RRC Connection Release with redirect to GSM triggered by
readOnly CS Fallback.

Condition: A CS Fallback attempt is performed towards a GSM Frequency


Group, defined as a RRC Connection Release with redirect information, due
to a received CS Fallback Indicator set to CS Fallback Required in Initial
Context Setup Request or UE Context Modification Request.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmUeCtxtRelCsfbGsmEm
noNotification
nonPersistent The number of RRC Connection Release with redirect to GSM triggered by
readOnly CS Fallback Emergency.

Condition: An Emergency CS Fallback attempt is performed towards a GSM


Frequency Group, defined as a RRC Connection Release with redirect
information, due to a received CS Fallback Indicator set to CS Fallback High
Priority in Initial Context Setup Request or UE Context Modification
Request.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmUeCtxtRelCsfbHoPrepFail1xRtt
noNotification
nonPersistent Number of times a CS Fallback has been triggered where the UE should be
readOnly doing a handover to a cell found by measurements, the handover
preparation failed and the UE was redirected to a CDMA2000 1xRTT
frequency

Condition: CS Fallback has been initiated and a target cell for handover has
been determined, but handover preparation has failed.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelCsfbHoPrepFail1xRttEm
noNotification
nonPersistent Number of times a CS Fallback Emergency Call has been triggered where
readOnly the UE should be doing a handover to a cell found by measurements, the
handover preparation failed and the UE was redirected to a CDMA2000
1xRTT frequency

Condition: CS Fallback Emergency Call has been initiated and a target cell
for handover has been determined, but handover preparation has failed.
Counter type: PEG
Sampling rate: -

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 149 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long pmUeCtxtRelCsfbLimitedDualRadioUeCdma
noNotification
nonPersistent The number of RRC Connection Release triggered by CS Fallback for Limited
readOnly Dual Radio UE LTE/1xRTT.

Condition: A CS Fallback attempt is performed for a limited Dual Radio UE


towards CDMA2000 1xRTT, defined as a RRC Connection Release, due to a
received CS Fallback Indicator set to CS Fallback Required in Initial Context
Setup Request or UE Context Modification Request.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmUeCtxtRelCsfbMeasTO1xRtt
noNotification
nonPersistent Number of times a CS Fallback has been triggered where the UE should be
readOnly doing a handover to a cell found by measurements, the measurement failed
to find a target cell, and the UE was redirected to a CDMA2000 1xRTT
frequency

Condition: CS Fallback has been initiated for the UE and the UE has
searched for, but failed to find, a target cell for handover and the
measurement has timed out.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelCsfbMeasTO1xRttEm
noNotification
nonPersistent Number of times a CS Fallback Emergency Call has been triggered where
readOnly the UE should be doing a handover to a cell found by measurements, the
measurement failed to find a target cell, and the UE was redirected to a
CDMA2000 1xRTT frequency

Condition: CS Fallback Emergency Call has been initiated for the UE and the
UE has searched for, but failed to find, a target cell for handover and the
measurement has timed out.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelCsfbTdScdma
noNotification
nonPersistent The number of RRC Connection Release with redirect to TD-SCDMA
readOnly triggered by CS Fallback.

Condition: A RRC Connection Release with redirect information to TD-


SCDMA triggered by CS Fallback. Counter includes Release with Redirect
including NACC.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmUeCtxtRelCsfbTdScdmaEm
noNotification
nonPersistent The number of RRC Connection Release with redirect to TD-SCDMA
readOnly triggered by CS Fallback Emergency.

Condition: A RRC Connection Release with redirect information to TD-


SCDMA triggered by CS Fallback Emergency. Counter includes Release with
Redirect including NACC.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 150 of 162

Counter type: PEG


Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmUeCtxtRelCsfbWcdma
noNotification
nonPersistent The number of RRC Connection Release with redirect to WCDMA triggered
readOnly by CS Fallback.

Condition: A CS Fallback attempt is performed towards a WCDMA


Frequency, defined as a RRC Connection Release with redirect information,
due to a received CS Fallback Indicator set to CS Fallback Required in Initial
Context Setup Request or UE Context Modification Request.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmUeCtxtRelCsfbWcdmaEm
noNotification
nonPersistent The number of RRC Connection Release with redirect to WCDMA triggered
readOnly by CS Fallback Emergency.

Condition: An Emergency CS Fallback attempt is performed towards a


WCDMA Frequencies, defined as a RRC Connection Release with redirect
information, due to a received CS Fallback Indicator set to CS Fallback High
Priority in Initial Context Setup Request or UE Context Modification
Request.
Counter type: PEG
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmUeCtxtRelMme
noNotification
nonPersistent The total number of UE Context Releases initiated by the MME excluding
readOnly successful handover. The counter is stepped regardless of whether data
was or was not lost in UL/DL buffers.

Condition: Stepped at reception of S1 message UE Context Release


Command (except if the cause was successful handover) and the release is
MME initiated.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelMmeAct
noNotification
nonPersistent The total number of UE Context Releases initiated by the MME excluding
readOnly successful handover and that there was data in either the UL or DL buffer
(i.e. active).

Condition: If there was data in the buffer at the time of release, then
stepped at reception of S1 message UE Context Release Command (except
if the cause was successful handover). The release must also have been
MME initiated.
Counter type: PEG
Scanner: Primary
Counter is reset after measurement period: Yes
long pmUeCtxtRelNormalEnb
noNotification
nonPersistent The total number of normal UE Context Releases triggered by RBS. The
readOnly counter is stepped regardless of whether data was or was not lost in UL/DL
buffers.

Condition: Stepped at reception of S1 message UE Context Release

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 151 of 162

Command when internal cause codes considered normal (Successful


Handover, User Inactivity, Inter-RAT redirection, CS Fallback Triggered)
when the RBS initiated the release.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelNormalEnbAct
noNotification
nonPersistent The total number of normal UE Context Releases triggered by RBS and that
readOnly there was data in either the UL or DL buffer (i.e. active).

Condition: If there was data in the buffer at the time of release, then
stepped at reception of S1 message UE Context Release Command when
internal cause codes considered normal (Successful Handover, User
Inactivity, Inter-RAT redirection, CS Fallback Triggered) when the RBS
initiated the release.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelNormalEnbTuneOut
noNotification
nonPersistent The total number of normal UE Context Releases initiated by the RBS for
readOnly Tune-out UEs. The counter is stepped regardless of whether data was or
was not lost in UL/DL buffers

Condition: Stepped at reception of S1 message UE Context Release


Command when internal cause codes considered normal (Successful
Handover, User Inactivity, Inter-RAT redirection, CS Fallback Triggered)
when the RBS initiated the release.
Stepped in case UE type is Tune-out

Counter type: PEG


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelSCCdma
noNotification
nonPersistent The number of Session Continuity RRC Connection Release with redirect to
readOnly CDMA2000.

Condition: A RRC Connection Release with redirect information to


CDMA2000.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelSCEUtra
noNotification
nonPersistent The number of RRC Connection Release with redirect to E-Utra.
readOnly

Condition: A RRC Connection Release with redirect information to E-Utra.


Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelSCGsm
noNotification
nonPersistent The number of Session Continuity RRC Connection Release with redirect to
readOnly GERAN.

Condition: A RRC Connection Release with redirect information to GERAN.


Counter type: PEG

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 152 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long pmUeCtxtRelSCTdScdma
noNotification
nonPersistent The number of Session Continuity RRC Connection Release with redirect to
readOnly UTRA TDD

Condition: A RRC Connection Release with redirect information to UTRA


TDD
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUeCtxtRelSCWcdma
noNotification
nonPersistent The number of Session Continuity RRC Connection Release with redirect to
readOnly UTRA FDD.

Condition: A RRC Connection Release with redirect information to UTRA


FDD.
Counter type: PEG
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..12] pmUeCtxtTa
nonUnique
noNotification Distribution of the measured Timing Advance value for UL synchronized UEs
nonPersistent
readOnly PDF ranges:
[0]: [0..9]%,
[1]: [10..19]%,
[2]: [20..29]%,
[3]: [30..39]%,
[4]: [40..49]%,
[5]: [50..59]%,
[6]: [60..69]%,
[7]: [70..79]%,
[8]: [80..89]%,
[9]: [90..99]%,
[10]: [100..109]%,
[11]: [110..200]%

Condition: Periodically the actual TA of the UEs that are UL synchronized is


monitored, one scan performed every 5 seconds. Example: When a sample
is measured at 50% it means that an UL synchronized UE has a TA value at
50% of the configured cell range. In this case bin 6 for 50%..59% is
increased.
Counter type: PDF
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..8] pmUeThpDlDistr
nonUnique
noNotification Distribution of the DL UE throughput. One DL UE throughput sample is
nonPersistent obtained by dividing the total volume (PDCP SDU) on Data Radio Bearers
readOnly per UE, that has been transferred (acknowledged by the UE) in the
downlink direction, with a time interval applicable to the volume
measurement.

PDF ranges:
[0]: 0 < DL UE thp sample < 1.000
[1]: 1.000 <= DL UE thp sample < 5.000
[2]: 5.000 <= DL UE thp sample < 10.000
[3]: 10.000 <= DL UE thp sample < 20.000

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 153 of 162

[4]: 20.000 <= DL UE thp sample < 50.000


[5]: 50.000 <= DL UE thp sample < 100.000
[6]: 100.000 <= DL UE thp sample < 150.000
[7]: 150.000 <= DL UE thp sample

Unit: 1 kbps

Condition: For each completed UE data session, or at end of ROP, one DL


UE bit rate sample is added to the distribution.
Counter type: PDF
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmUeThpTimeDl
noNotification
nonPersistent The effective DL transport time comprises those periods from when the first
readOnly part of the PDCP SDU of the DL buffer was transmitted on Uu until the
buffer is emptied, excluding the TTI emptying the buffer.

When carrier aggregation is used, a PDCP SDU can be sent over multiple
cells (PCell/SCell(s)). The effective DL transport time, comprising those
periods from when the first part of the PDCP SDU of the DL buffer was
transmitted on Uu until the buffer is emptied, excluding the TTI emptying
the buffer, is registered on PCell.

Unit: 1 ms
Filter: FDD
Condition: Continuous measurement for UEs aggregated to cell level.
Counter type: ACC
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmUeThpTimeUl
noNotification
nonPersistent The UL volume transfer time used for UL UE Throughput. It comprises of
readOnly time periods from when the 5th MAC SDU data reception of an UL buffer
transfer on Uu until the buffer is emptied, excluding the TTI emptying the
buffer.

Unit: 1 ms
Condition: Continuous measurement for UEs aggregated to cell level.
Counter type: ACC
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmUeThpTimeUlRs
noNotification
nonPersistent The time where the UE have uplink data in a buffer and End-user bitrate
readOnly shaping functionality will prohibit transmission in the uplink.

Unit: 1 ms
Deprecated: Since L12A. Has no functional behaviour. Planned to be
removed.

Condition: Data in uplink buffer, according to the Buffer Status Report


(BSR) and Token Bucket Counter (TBC) less than 0. Continuous
measurement for UEs aggregated to cell level.
Counter type: ACC
Sampling rate: -

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 154 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long[0..8] pmUeThpUlDistr
nonUnique
noNotification Distribution of the UL UE throughput. One UL UE throughput sample is
nonPersistent obtained by dividing the total volume (PDCP SDU) on Data Radio Bearers
readOnly per UE, that has been received in the uplink direction, with a time interval
applicable to the volume measurement.

PDF ranges:
[0]: 0 < UL UE thp sample < 1.000
[1]: 1.000 <= UL UE thp sample < 3.000
[2]: 3.000 <= UL UE thp sample < 5.000
[3]: 5.000 <= UL UE thp sample < 10.000
[4]: 10.000 <= UL UE thp sample < 20.000
[5]: 20.000 <= UL UE thp sample < 30.000
[6]: 30.000 <= UL UE thp sample < 60.000
[7]: 60.000 <= UL UE thp sample

Unit: 1 kbps

Condition: For each completed UE data session, or at end of ROP, one UL


UE bit rate sample is added to the distribution.
Counter type: PDF
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmUeThpVolUl
noNotification
nonPersistent The UL DRB volume used for UL UE Throughput. It comprises of the MAC
readOnly SDU volume received on Uu, excluding the volume received in the first 4
data receptions of an UL buffer transfer and the TTI emptying the UL
buffer.

Unit: 1 kilobit (1 000 bits)


Condition: Continuous measurement for UEs aggregated to cell level.
Counter type: ACC
Sampling rate: -
Scanner: Primary
Counter is reset after measurement period: Yes
long pmUlGrantsTrans
noNotification
nonPersistent The total number of unicast UL grants transmitted.
readOnly
Condition: It is pegged when an unicast UL grant is transmitted excluding
the UL grants for message 3.
Counter type: ACC
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmUlGrantsWithDetectedPusch
noNotification
nonPersistent The total number of unicast UL grants that are confirmed by detecting a
readOnly corresponding PUSCH transmission.

Condition: It is pegged when an unicast UL grant is confirmed by detecting


a corresponding PUSCH transmission (excluding message 3).
Counter type: ACC
Sampling rate: -

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 155 of 162

Scanner: Not included in any predefined scanner


Counter is reset after measurement period: Yes
long pmVoipQualityUeUlLowSampl
noNotification
nonPersistent The number of VoIP quality measurements that can not determine the VoIP
readOnly satisfaction of a UE due to insufficient statistics. These measurements are
excluded when the VoIP integrity KPI is calculated.

Condition: The counter is incremented when less then the minimum


amount of VoIP packets is available for the measurement and at least 50%
of the VoIP packets of the UE have an air interface delay within the packet
delay budget.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmVoipQualityUeUlNok
noNotification
nonPersistent The number of UE that are not satisfied with their VoIP quality.
readOnly

Condition: The counter is incremented when it has been determined that a


UE is not satisfied with its VoIP quality. This can be caused due to two
conditions: (1) At least the minimume amount of VoIP packets is available
for the measurement and less than 99% of the VoIP packets of the UE had
an air interface delay within the packet delay budget. (2) 50% or less of the
VoIP packets of the UE had an air interface delay within the packet delay
budget, regardless of the amount of VoIP packets for measurement.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmVoipQualityUeUlOk
noNotification
nonPersistent The number of UE that are satisfied with their VoIP quality.
readOnly

Condition: The counter is incremented when it has been determined that a


UE is satisfied with its VoIP quality. This means that at least the minimume
amount of VoIP packets is available for the measurement and that at least
99% of the VoIP packets of the UE had an air interface delay within the
packet delay budget.
Counter type: PEG
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary1
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary10
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 156 of 162

Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary11
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary12
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary13
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary14
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary15
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmZtemporary16Qci
nonUnique
noNotification Compressed: True
nonPersistent
readOnly Condition: -
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmZtemporary17Qci
nonUnique
noNotification Compressed: True
nonPersistent
readOnly Condition: -
Counter type: PDF

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 157 of 162

Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmZtemporary18Qci
nonUnique
noNotification Compressed: True
nonPersistent
readOnly Condition: -
Counter type: PDF
Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary19
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary2
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary20
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary21
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary22
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary23
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 158 of 162

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary24
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary25
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary26
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary27
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary28
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary29
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary3
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 159 of 162

Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary30
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary31
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary32
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary33
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary4
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary5
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary57
noNotification

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 160 of 162

nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly
used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: SCAN


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmZtemporary58
nonUnique
noNotification Normally this counter is not used, it can however sometimes be temporarily
nonPersistent used for very late additions in a release. If so, for description see Network
readOnly Impact Report in the CPI.

Counter type: PDF


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long[0..256] pmZtemporary59
nonUnique
noNotification Normally this counter is not used, it can however sometimes be temporarily
nonPersistent used for very late additions in a release. If so, for description see Network
readOnly Impact Report in the CPI.
Compressed: True

Counter type: PDF


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary6
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary60
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary61
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary62
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 161 of 162

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary63
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary64
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary65
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary66
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary67
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary68
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018
class EUtranCellFDD Page 162 of 162

long pmZtemporary69
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary7
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary70
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary71
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: ACC


Sampling rate: -
Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary8
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes
long pmZtemporary9
noNotification
nonPersistent Normally this counter is not used, it can however sometimes be temporarily
readOnly used for very late additions in a release. If so, for description see Network
Impact Report in the CPI.

Counter type: PEG


Scanner: Not included in any predefined scanner
Counter is reset after measurement period: Yes

http://localhost:9032/alexserv?AC=LINK&ID=8618&FN=15554-EN_LZN7850001_1-... 7/18/2018