The Development of the Structural Health Monitoring System for
Early Fault Diagnosis by using Acoustic Emission
A dissertation
by
Dong Hyun Kim
Contents ........................................................................................................... i
List of figures .................................................................................................. v
List of tables ................................................................................................... ix
List of abbreviations ....................................................................................... xi
I. Introduction ......................................................................................... 1
1.1 Technical, economic and social background .................................... 1
1.2 Motivation and significance of this research .................................... 4
1.3 Aims and objectives ........................................................................ 5
1.4 Contributions .................................................................................. 6
References ............................................................................................... 7
i
References ..............................................................................................28
ii
4.1.1 Introduction ............................................................................57
4.1.2 Review of leak theory and BTLD system ................................59
4.1.3 Proposed system and installation.............................................60
4.1.4 Fault diagnosis strategy...........................................................64
4.1.5 3D source location for tube leak ..............................................67
4.1.6 Experiment and results ............................................................72
4.2 Structural integrity monitoring for seamless pressure vessel ...........81
4.2.1 Introduction ............................................................................81
4.2.2 Structure of seamless pressure vessel ......................................82
4.2.3 Test procedure and acceptance criteria ....................................82
4.2.4 Experiment and results ............................................................84
4.3 Structural health monitoring of blast furnace in steel mill ...............91
4.3.1 Introduction ............................................................................91
4.3.2 Review of conventional study .................................................91
4.3.3 Monitoring strategy of blast furnace and blower .....................92
4.3.4 Experiment and results ............................................................93
4.3.5 Feature extraction and classification of fault signal .................97
4.3.6 Crack detection and leak monitoring of blast furnace ............ 108
4.4 Conclusion ................................................................................... 112
4.4.1 Source location in structure ................................................... 112
4.4.2 Early fault detection in structure ........................................... 112
References ............................................................................................ 113
iii
감사의 글.................................................................................................... 122
iv
List of figures
v
Fig. 3.6 Preamplifier module circuit diagram....................................................36
Fig. 3.7 Preamplifier PCB ................................................................................37
Fig. 3.8 Main amplifier module circuit diagram................................................38
Fig. 3.9 Main amplifier module PCB ................................................................38
Fig. 3.10 Power and signal driver design of main-amplifier ..............................39
Fig. 3.11 Power and signal driver design of pre-amplifier .................................40
Fig. 3.12 Signal level trigger module circuit diagram .......................................41
Fig. 3.13 Signal level trigger module PCB .......................................................41
Fig. 3.14 AE monitoring hardware configuration ..............................................42
Fig. 3.15 AE monitoring hardware block diagram ............................................43
Fig. 3.16 4ch AE monitoring hardware .............................................................43
Fig. 3.17 8ch AE system...................................................................................44
Fig. 3.18 Multi channel AE system...................................................................44
Fig. 3.19 UI design of main window for real time fault monitoring ..................46
Fig. 3.20 Channel setup window before data acquisition ..................................47
Fig. 3.21 Trend management window ...............................................................48
Fig. 3.22 Post processing window for fault diagnosis .......................................50
Fig. 3.23 Multi FFT window for fault frequency analysis .................................51
Fig. 3.24 AE feature analysis window ..............................................................51
Fig. 3.25 Frequency response test result ...........................................................53
Fig. 3.26 Noise level test result ........................................................................54
Fig. 4.1 Leak flow ............................................................................................59
Fig. 4.2 The principle of boiler tube leak detection method by using compound
sensor for AE and vibration ................................................................60
Fig. 4.3 System configuration and location of BTLD........................................62
Fig. 4.4 Detail system configuration of BTLD ..................................................63
Fig. 4.5 Location of sensor (18channel) ............................................................63
Fig. 4.6 Overview of fault diagnosis .................................................................66
vi
Fig. 4.7 3D source location and 3D modeling flow chart ..................................67
Fig. 4.8 2D & 3D modeling for boiler structure before source location .............69
Fig. 4.9 Simulation of 3D source location for boiler structure...........................71
Fig. 4.10 Characteristic DB of signal attenuation..............................................72
Fig. 4.11 Leak alarm setup during working condition .......................................73
Fig. 4.12 Signal feature with and without baffle plate using soot blower...........74
Fig. 4.13 Outside and inside shape of soot blower ............................................75
Fig. 4.14 Pressure vessel test during overhaul period ........................................75
Fig. 4.15 3D source location result using soot blower No. 90 and No. 110........76
Fig. 4.16 Location of soot blower to test of 3D source location ........................77
Fig. 4.17 3D source location result during soot blowing ...................................77
Fig. 4.18 RMS trend during actual tube leak.....................................................79
Fig. 4.19 3D source location result when actual leak was occurred ...................80
Fig. 4.20 Seamless pressure vessel for Type 1 and Type 2 ................................82
Fig. 4.21 System configuration.........................................................................84
Fig. 4.22 Test method for Type 2 ......................................................................86
Fig. 4.23 System configuration for Type 1 ........................................................86
Fig. 4.24 Cycle test for Type 1..........................................................................87
Fig. 4.25 AET and UT test result for Type 1 pressure vessel .............................88
Fig. 4.26 AE hit vs cumulative count ................................................................88
Fig. 4.27 Test environment for Type 2 ..............................................................88
Fig. 4.28 Test result of Type 2 ..........................................................................89
Fig. 4.29 Early fault detection for blast furnace using AE sensor ......................92
Fig. 4.30 Structure of blast furnace ...................................................................93
Fig. 4.31 AE system configuration for blast furnace .........................................93
Fig. 4.32 Crack for blower and leak monitoring ...............................................95
Fig. 4.33 BB gun test at AE 4-1 and AE 4-4 in steel shell .................................95
Fig. 4.34 Scratch test at 25 and 26 in blower ....................................................96
vii
Fig. 4.35 BB gun test result at AE 4-1 ..............................................................98
Fig. 4.36 BB gun test result at AE 4-3 ..............................................................99
Fig. 4.37 Rise time, duration, and FFT result at AE 4-1 .................................. 100
Fig. 4.38 Rise time, duration, and FFT result at AE 4-2 .................................. 101
Fig. 4.39 Rise time, duration, and FFT result at AE 4-3 .................................. 102
Fig. 4.40 Existing crack and new crack .......................................................... 109
Fig. 4.41 Change of AE energy trend during crack propagation (overlap) ....... 109
Fig. 4.42 Change of AE energy trend during crack propagation ...................... 110
Fig. 4.43 Shape of blower in blast furnace ...................................................... 111
Fig. 4.44 Change of RMS trend when blower is leak ...................................... 111
viii
List of tables
ix
Table 4.17 BB gun signal at AE 4-5 ............................................................. 106
Table 4.18 Water drops signal and BB gun signal at AE 4-1, 4-2, 4-3 ........... 107
Table 4.19 Water drops signal and BB gun signal at AE 4-4, 4-5 .................. 107
x
List of abbreviations
xi
PSU Power Supply Unit
SCU Signal Conditioning Unit
PDT Peak Definition Time
HDT Hit Definition Time
HLT Hit Lockout Time
DSP Digital Signal Processor
PC Personal Computer
OP AMP Operational Amplifier
BTLD Boiler Tube Leak Detection
PRH Primary Reheater
FRH Final Superheater
PSH Primary Superheater
ECO Economizer
FPGA Field Programmable Gate Array
1D One Dimensional
2D Two Dimensional
3D Three Dimensional
SB Soot Blower
DB Data Base
DOT Department of Transportation
NGV Natural Gas Vehicle
PLB Pencil Lead Break
ASTM American Society of Testing Materials
xii
The Development of the Structural Health Monitoring System for Early Fault
Diagnosis by using Acoustic Emission
Abstract
xiii
Testing method was proposed to detect and diagnosis fault signals for industrial
facility and large power plant structure. To satisfy field requirement, this study
apply compound sensor for vibration and acoustic emission to detect fault signal
from the object and design specialized waveguide for high temperature and
dangerous area.
In order to acquire wide range of fault signals from low to high frequency range,
special purpose of signal conditioning module such as pre-amplifier and main-
amplifier are needed. And data acquisition hardware such as signal level trigger
module, high speed data acquisition module, CPU module are also required.
In addition, to find the location of fault for small and large structure, source
location technique is applied. Based on raw data from power plant, this study
proposed feature extraction, selection, classification, and clustering.
Finally, in data interpretation and evaluation, 3D source locating technique as
well as fault analyzing technique with various AE features such as energy,
amplitude, rise time, duration, RMS, and so on, are performed for structural health
monitoring .
In this thesis, AE monitoring hardware newly developed and software are also
designed as a real-time, post-processing respectively.
The on-line monitoring system to be used for multi-parameter monitoring of
physical structure and processes.
Proposed source location and early detection technique confirmed through
application case. Study results show that AE system can detect and prevent
unexpected plant accident early, and contributes to maximize the effectiveness of
power generation.
xiv
I. Introduction
Public safety and the importance of reliable state monitoring and diagnostics
technology are highlighted with increasing people’s desire for safety and the
growth of industrial economy. As to variety and rapid growth of industrial society,
complex and large scale of industrial facilities and structures are trended. Under
this condition, the technology of Non-destructive Test (NDT) is discussed as core
technology[1].
NDT is a wide group of analysis techniques used in science and industry to
evaluate the properties of a material, component or system without causing
damage. Because NDT does not permanently alter the article being inspected, it is
a highly-valuable technique that can save both money and time in product
evaluation, troubleshooting, and research. Common NDT methods include
ultrasonic, magnetic-particle, liquid penetrant, radiographic, remote visual
inspection (RVI), eddy-current testing, and low coherence interferometry. NDT is
a commonly-used tool in forensic engineering, mechanical engineering, electrical
engineering, civil engineering, systems engineering, aeronautical engineering,
medicine, and art[2].
According to the Yano research institute, the size of test equipment market in
2008 is estimated to reach 2.777billion USD and 6% of annual growth rate is
shown and this market is estimated 3.717billion USD after five years later. In
addition additional market including NDT equipment and service engineering are
proportional growth, it is expected over 150billion USD in 2013[3].
On the other hand, domestic Non-Destructive Test Equipment Market in 2008
is about 384.1 billion Korean Won and its annual growth rate in average reaches
1
about 5.5% and this maker is estimated 502billion Korean Won[4].
Fig. 1.2 Domestic market volume for NDT equipment and rate
In order to perform the diagnose of fault on large scale structure, the research
for facility diagnose on in this paper has been formed by using Acoustic Emission
method which is prominent in industries recently.
The Acoustic Emission (AE) is commonly defined as transient elastic waves
within a material, caused by the release of localized stress energy. Hence, an event
source is the phenomenon which releases elastic energy into the material, which
2
then propagates as an elastic wave. AE can be detected in frequency ranges under
1 kHz, and have been reported at frequencies up to 100 MHz, but most released
energy within 1 kHz to 1 MHz. Rapid stress-releasing events generate a spectrum
of stress waves starting at 0 Hz, and typically falling off at several MHz.
The three major applications of AE techniques are: 1) source location -
determine the locations where an event source occurred; 2) material mechanical
performance - evaluate and characterize materials/structures; and 3) health
monitoring - monitor the safety operation of a structure, i.e. bridges, pressure
containers, and pipe lines, etc[5].
Vibration monitoring techniques are interested in several Hz to 10 kHz of
frequency range, but AE method is interested in wide frequency range of 20 kHz
to 1.2MHZ. This characteristic in AE techniques make that extremely fine strain
or crack can be sensed measuring even a few µV of high sensitive range and also
continuous monitoring of cracking occurrence and its occurring time can be
recognized while system is operated.
However, there are limitations in AE techniques. In AE techniques, the
measurement and detection of signals can be possible only in the condition the
external force is applied and It is difficult to distinguish normal signal and fault
signal in noisy environment. Although severity of fault can be measured by AE
method, other test methods for example Ultrasound Test (UT) or Radiographic
Test (RT) are used in parallel for confirm fault as complement. Moreover the fault
size also cannot be distinguished in AE method.
AE techniques are used in the various fields such as diagnosis on rotating
machine[6], evaluation for material characteristics and diagnosis of normality on
structures[7], crack and fault on storage tank and pressure vessel[8], leak
monitoring on main reactor facility[9], safety monitoring on civil work[10],
monitoring of turbine condition in power plant[11], boiler tube leak monitoring in
power plant[12], crack monitoring of blast furnace in steel mill[13], leak
3
monitoring on the pipe underground[14], etc.
On the other hand, commercialized fault detecting system in domestic and
overseas are limitations for applying AE method as follow cases. In case
interested frequency is known and unknown and fault signals have dual band with
low and high frequency range, it is difficult to detect fault signal using
conventional system.
In large scale and complex structure, it has limitation to attach sensors in
dangerous area, 3D visualization in fault location, and fault analysis and diagnose
with final measured and specified data are not easy.
Ease of installation has been improved, to solve the conventional technical
limitation mentioned above, by applying compound sensor for acoustic emission
and vibration for sensing limitation and by developing variety sensing sub module
on complicated structure.
Analysis and data processing for low and high frequency range can be
improved by applying the compound sensing module and signal conditioning unit
which amplify and filter the collected signal.
In fault diagnosis, reading and detection capability for fault has been increased
by extracting, classifying and clustering of collected and specified data from the
field.
Finally, by applying 1 to 3D location detecting algorism on final collected data
from field, and by detecting the signal from early fault detector, conventional self
detecting device can be improved with reliability and technology on various
equipments. Human life and property damage from accident can be minimized
ultimately.
4
Monitoring System (CMS) which is applied by AE techniques in performing
condition monitoring and diagnosis on industrial equipment.
The significance of this research is early fault detection by compound sensing
technology for low frequency vibration range and high frequency AE range. In
case of fault detection for large scaled structure, it can easily find the fault area
using 3D source location technique.
This paper is to ensure its reliability by realizing the continuous and early
detection of boiler tube leak in power plant, structure health evaluation of pressure
vessel, crack monitoring of blast furnace in steel mill.
The aims of this research suggests early fault detection system on industrial
equipment by the AE method and detecting method. And this system includes
graphic user interface to detecting the fault location with sensing equipment,
signal conditioning module, data acquisition hardware.
Sub unit of waveguide which is suitable for signal collection on
complex and large structure, and design and application of and
magnetic holder.
5
Development of Graphic User Interface for condition monitoring of
fault.
6
References
[1] IAEA, Non-destructive testing for plant life assessment, vienna, 2005.
[2] http://en.wikipedia.org/wiki/Nondestructive_testing.
[3] Yano Research Institute, Nondestructive Inspection Market 2006, 2006.
[4]KONICOF, Analysis of nondestructive testing global market trend and
competitive, 2009.
[5] http://en.wikipedia.org/wiki/Acoustic_emission.
[6] L.D.HALL, D.MBA and R.H.BANISTER, Acoustic Emission signal
classification in condition monitoring using the kolmogorov-smirnov statistic,
Journal of Acoustic Emission, 19, 2001.
[7] Kentaro OHNO, Shinichiro SHIMOZONO, Yosuke SAwAdA, and Masayasu
OHTSU., Mechanisms of Diagonal-Shear Failure in Reinforced Concrete
Beams analyzed by AE-SigMA, Journal of Solid Mechanics and Materials
Engineer, Vol. 2, No. 4, 2008.
[8] A.A.Anastasopoulos, D.A. Kourousis, P.T. Cole, Acoustic Emission
Inspections of Spherical Metallic Pressusre Vessels, International Conference
on Technical Inspection and NDT(TINDT2008), October 2008.
[9] American Society of Mechanical Engineering(ASME) OM-S/G-2005, New
York, August 31, 2005.
[10] Xiu LUO, Dr. Hiroshi HAYA, Dr., Tomoaki NIABA, Tomoki SHIOTANI, Dr.,
Yasuhiro NAKANISHI, Secondary AE Techniques for Non-Destructive
Inspection of Railway Structures, QR of RTRI, Vol. 44, No. 4, Nov. 2003.
[11] Akihiro SATO, Elsaku NAKASHIMA, Masami KOIKE, Morihiko MAEDA,
Toshikatsu YOSHIARA, and Shigeto NISHIMOTO, Development of
abnormality detection technology for electric generation steam turbines,
Journal of Acoustic Emission, 19, 2001.
7
[12] Jirapong Lim, tonphong Kaewkongka, Leakage Evaluation of heating coil
tube in thermal oil boiler by using Acoustic Emission and data classification
technique, FMtC 2008-IEEE International Instrumentation and Measurement
technology Conference, Victoria, Vancouver Island, Canda, May12-15, 2008.
[13] R van Oudenallen, K Andreev, M Gerdees, MAG Bentes, AHB de Mello and
F Franklin Danieli Corus BV, Corus group, M Gerdees and Partners and
Companhia Siderurgica National (CSN), Expansion phenomena in blast
furnace health aftwer blow-in, Millennium Steel, 2008.
[14] Enviroacoustic ABEE, EL. Venizelou 7 & Delfon, 14452 Metamorphosis,
Athens, GREECE, Acoustic Emission leak detection of buried pipeline,
Janese Society for NDI, 2008.
8
II. Review on AE Signal Processing and
Source Location
2.1 Introduction
9
2.2 AE signal processing
10
Fig. 2.3 Signal processing for pre-amplifier and main-amplifier
2.3 AE features
AE features are mainly divided into four types in time and frequency domains, as
shown Fig. 2.4.
Time domain consists of Time driven feature, Hit based features and
Combination features combining Time driven feature and Hit based features, and
frequency domain is generally classified as the frequency feature[4].
11
Fig. 2.5 explains basic AE features according to the ISO 12716:2001[5].
Threshold-based measuring feature is defined for any actual input signal, and
according to when applied, it may also be divided into conventional feature
analysis methods[6] and the latest analysis method[7] according to recent research
trends to be used.
In conventional features, it described as Table 2.1 to Table 2.4. this features are
widely used when we evaluate most of the object. In latest analysis method such
as Load Ratio, RTRI Ratio, Calm Ratio, and RA Value, it defined as table 2.5.
This features are used to evaluated concrete structures that the fracture mode of
cracking is changing from the tensile type of fracture to the shear type of fracture
with progress of fracture.
As a reference, Load ratio is obtained from any kinds of AE parameters at the
12
onset of AE activity PAE. Fig. 2.6 is useful to analyze of correlation with selected
features, which well presented during load time to the object. Fig. 2.7 is useful to
evaluate of damage quantification with a combination of Calm and Load ratio. Fig.
2.8 is useful to discriminate crack type classification with a combination of
average frequency and RA values.
In this way, to discriminate and evaluate specialized object, this kind of various
analysis method are required.
13
Absolute Energy It is a 6-byte value that has aJ (attoJules) unit. This variable
measures the actual energy value of AE hit. Absolute Energy is
performed by integral of squared voltage divided by reference
resistance during the entire interval (10kΩ) of the AE waveform
packet. It is a good variable for monitoring continuous signals.
14
a fixed value and floating value.
Count to It measure of the number of AE counts between the AE hit start and the
Peak Peak amplitude of the AE hit.
C=
å (M ´ f ) [kHz]
åM
Partial Power It is inducted to the power spectrum of AE hit-related
waveform and is recorded as %, and the sum of power
spectrum in user-specified frequency interval (up to four can
be specified) is divided by the power of the entire frequency
interval and is calculated by multiplying the result by 100.
15
Table 2.5 Definition of other features
Feature Description
Load Ratio
PAE ( AE occurence load start )
Felicity Ratio ( FR ) =
P1st ( Maximum load in the past )
16
Fig. 2.8 Combination of average frequency and RA values
2.4.1 Fault diagnosis using time driven and hit based feature
This is one of the popular ways in fault diagnosis. It finds the variance of
feature diagnosis by time and identifies normal and fault signal as well as
explains its description and method.
17
Fig. 2.9 Fault diagnosis using AE feature for pressure vessel
18
Fig. 2.10 Fault diagnosis using AE feature for semiconductor process line
Fault diagnosis has been carried out through correlation diagnosis, no like as
the fault diagnosis shown in Fig 2.12.
(a) case is the correlation diagnosis based on selected feature signal and it
shows the process that signal more than 70 in count is judged as crack
signal occurred in process.
19
(b) shows the determination criteria for the acceptance or fault in case that
peak signal exceeds 2.5V when crack signal occurs.
Therefore it is understood that fault determination and classification criteria
may vary according to the correlation diagnosis of feature data (Count, Peak,
Average frequency) that support final effective judgment in case of fault
determination.
20
2.5 Source location algorithm and it’s application
For large structure such as power generation facility, diagnosis is not simple
because it is required to install a lot of sensors on large structure for
collecting signal and diagnosis. Recently source location technique is widely
used to the complex and large scaled structure[8-10]. In such case it is
necessary to arrange sensors at optimized locations and make quick decision
whether operating or stopping facility through collecting and analyzing
signals. To do this, basic source location algorithm[11-12] is applied.
For fault diagnosis, database of structure properties shall be built based on
collected signals to identify normal and abnormal signals, classify faults by
abnormal signals and then study to find the location finally.
To estimate the location, assuming that the location where many AE events
have been detected may be the fault(corrosion, crack, leakage) location, one
point represents 1 event and the location where cluster is concentrated is
understood as a damaged location.
In order to carry out fault location, sensor is installed available place which
can easily detect when fault is occurred and data is stored with a alarm
signal in case of detection over reference signal level.
Stored data is started feature extraction based on raw data. 3D fault location
is performed with the x, y, z axis selected feature value according to the shape
of the monitoring object.
To improve location error, compare with reference database in normal
condition and error correction of the location is performed. Finally, fault
location is indicated as clustering with multi point.
21
Principle of 1D source location
Ct1, = x - x1 , Ct 2, = x - x 2 (2-1)
CDt12 = x - x1 - x - x 2 (2-2)
Basic theory is same with 1D source location and over two and three
22
sensors are used to apply 2D source location.
CDt12 = ( x - x1 )2 + ( y - y1 )2 - ( x - x2 )2 + ( y - y2 )2 (2-3)
CDt13 = (x - x1 ) 2 + ( y - y1 ) 2 - (x - x3 )2 + ( y - y3 )2 (2-4)
23
location is performed during loading process (pressure is filled as 110%
and hold condition) as shown Fig. 2.15 with two sensor at the end of
pressure vessel both side. In 1D source location, distribution and
location of fault is displayed as multi point on shape of pressure vessel.
24
Fig. 2.16 1D source location method for boiler tube
Fig. 2.17 show example of source location using multi channels according
to the different type of structure shape.
In this way zone of fault location is highlighted compare with other
channel, which is installed near by source.
25
Application of 2D source location (boiler structure)
Fig. 2.18 shows 2D source location for large structure of boiler in power
plant. According to the amplitude value one of the AE feature, zone location
is performed when fault signal is generated from the object.
In this case, location of fault occurrence is zone 4 with highest signal
amplitude from the structure. In this way it may be possible to define the
first, second and third amplitude level and thus narrow zone is reallocated.
In source location algorithm, it determine the difference between sensor
outputs and compare it with attenuation characteristics of component.
26
2.6 Conclusion
27
References
[1] http://en.wikipedia.org/wiki/Signal_processing.
[2] http:// en.wikipedia.org/wiki/Analog_signal_processing.
[3] http:// en.wikipedia.org/wiki/Digital_signal_processing.
[4] None destructive Testing Handbook Volume 6, Acoustic Emission Testing, 3rd
Edition, American Society for None destructive Testing, 2005, pp. 152-156.
[5] ISO 12716 2005
[6] PCI-2 BASED AE SYSTEM USER'S MANUAL Rev 2, PHYSICAL
ACOUSTICS CORPORATION, PRINCETON JUNCTION, NJ, October
2004, pp. 29-34.
[7] Christian U. Grosse, Masayasu Ohtsu Editors, Acoustic Emission Testing,
Springer, 2008, pp. 42-59.
[8] L.M.Rogers, Structural and Engineering Monitoring by Acoustic Emission
Methods-Fundamentals and Applications, 2001, pp. 20~51.
[9] Tadej Kosel, Igor Grabec, Peter Muzic, Location of acoustic emisson sources
generated by air flow, Ultrasonics 38, 2000, pp. 824~826.
[10] J.J. Kovecevich, Recent Advances in the Application of Acoustic Leak
Detection to Process Recovery Boilers, TAPPI Engineering Conference,
September 11-14, 1995.
[11] None destructive Testing Handbook Volume 6, Acoustic Emission Testing, 3rd
Edition, American Society for None destructive Testing, 2005, pp. 122-146.
[12] http://www.ndt-ed.org/EducationResources/
28
III. Design on the Acoustic Emission System
3.1 Introduction
To monitor and analyze of fault diagnosis for the large structural health
monitoring, The basic configuration of AE systems are consist of AE sensor,
Preamplifier, AE Data Acquisition System (DAS), and Analysis Software[1].
In addition, in order to analyze compound signal like leak and crack, multi-
purpose AE Systems, which have wide range of signal from several kHz to MHz,
signal conditioning function for amplifier and filtering, are required.
However, most of the conventional AE systems[2-4] are not support and
provide simultaneously vibration and AE signal. Also, in order to apply of
particular environmental structural health monitoring such as blast furnace, power
plant, and pressure vessel, newly designed systems are required. The purpose of
development of AE system is to provide versatile, customized system, and easy to
use for the special purpose customer’s needs.
29
AE sensor is equipment which converts mechanical signal by detecting
dynamic displacement to electrical signal. and sensors that piezoelectric built-in
are mainly used on the equipment.
Resonant type and wideband type sensor are used generally[5]. But compound
single sensor which can sense Acoustic Emission and vibration signal
simultaneously has been used in this paper[6].
In this case of compound sensor, by applying damper material of wideband AE
sensor as load weight material in piezoelectric accelerometer structure, damper
material is working as a function of load weight in low frequency of vibration
range. And in high frequency of AE range, it working by wideband AE sensor. Fig.
3.1 shows the size and frequency characteristic of compound sensor.
The objective of compound sensor at machine system is to establish the high
reliability and low cost early fault detecting system by sensing and analyzing the
vibration and AE signal simultaneously. Diagnosis in general is performed at few
Hz to few dozen kHz of vibration range.
Low frequency range is applied to analysis of unbalance or miss-alignment
shaft, high frequency above 10 kHz range is applied to detecting of abnormal
bearing behavior. But because the bearing abnormal behavior cannot be detected
at the lowest rotating machine, AE method is introducing.
The compound sensor has been used because reliability in fault detecting can be
increased not only detecting the fault on variety machine but also detecting the
leakage from the pipes at large power plant which is requested to analyzing of
vibration and AE signal simultaneously by detecting the low and high frequency.
30
3.2.2 AE waveguide design
In case of large scale structure like power plant, it is faced on complex and
risky environment. And if equipments are using in high temperature especially,
thermal damage by influence of high temperature should be considered, the sensor
in this case is protected by applying waveguide on the objects.
Fault signal of cracks and leakages on the objects can be sensed by waveguide
which is connected with objects by welding on one side, and connected with AE
sensor on the other side.
There are temperature of Curie point in piezoelectric ceramic material which is
used in AE sensor.
Piezoelectric ceramic material will lost its characteristic of piezoelectric at and
above Curie point temperature and lost the function as sensor. Accordingly, AE
sensor should not be exposed at and above Curie point temperature with care.
31
Curie point of AE sensor in general has the temperature range of 120°C to
300°C[7]. So AE sensor at and above the temperature of Curie point cannot be
attached on the objects directly. In this case, AE sensor can be protected by high
temperature environment by that one end of waveguide is welded on object, and
AE sensor is installed on other side of waveguide.
But there is possibility of attenuation effect in case of waveguide compared to
direct attachment on pipe. Attenuation effect on different length and diameter of
waveguide has been tested as shown Fig. 3.2.
Fig. 3.3 shows the test result of attenuation effect in different waveguide length.
The test result according to waveguide length showed almost similar
attenuation effect between waveguide connection and direct connection by same
distance.
Based on this test result, it had been confirmed that attenuation effect of
waveguide had happened by distance only but no additional attenuation.
Assume the 1m distance between sensor and signal source, the signal
attenuation only will be occurred in case of no use waveguide, and in case of use
0.3m length of waveguide became 1.3m distance by adding the 1m distance of
sensor and signal source, then signal attenuation effect of 1.3m distance will be
occurred. And the other factors like welding didn’t influence to additional
attenuation.
Using this test result, this research designed specialized waveguide for crack
detection and leak monitoring for the different type of structure body such as large
sized boiler in power plant, blast furnace in steel mill as shown Fig. 3.4.
In case of small objects, small magnetic holder which is made for special
purpose of detecting the fine fault by mounting the high sensitivity sensor, and by
combining of sensor and objects, can be used as shown Fig. 3.5.
32
Fig. 3.2 Design of various waveguide with different length and thickness
33
(a) waveguide for crack detection (b) waveguide for leak monitoring
Magnetic
(a) front (b) rear
Fig. 3.5 Special purpose magnetic holder to combine AE sensor with object
34
3.3 AE Signal conditioning module design
To collect the very weak AE signal such as crack, distinction for Signal to
Noise Ratio (SNR) must be accomplished in order to confirm the monitoring band
of reference signal vs. abnormal signal by controlling the amplification of
collected signal.
In case of collected AE signal in field, it makes possible to select the crack
signal by designing of Operation Amplifier (OP AMP) circuit which makes few
µV of weak signal component primary amplify to few mV signal size, and by
amplifying the signal size of 20dB/40dB/60dB selectively.
And unwanted signal components were able to remove by designing of two
Band Pass Filters (BPF) as low frequency signal and high frequency signal to
analyze the signal components of leakage area by crack and destruction among the
35
primary amplified signal components.
In case of BPF, it is implemented that Noise of -24dB/octave in the lowest can
be removed by implying 4th Shelled-key type active filter to improve barrier
properties.
It has been designed to facilitate crack monitoring of barrier properties of 2 kHz
to 20 kHz in case of low frequency band, and wideband of 100 kHz to 600 kHz in
case of high frequency.
Pre-amplified module has been designed by adding circuit to supply 24V, 4mA
of constant current signal sources.
Designed amplifier by installing variable resister made to correct the part errors
occurred when making system and it was able to setup the correct amplification
ratio.
And also, test points at each location were installed to facilitate the verification
of performance of the product when making and running of product. It improved
working efficiency.
36
Fig. 3.7 Preamplifier PCB
37
Fig. 3.8 Main amplifier module circuit diagram
3.3.3 Power and signal line driver design using single cable
In case of typical measurement system, power supply and signal transfer line
are requested individually, but if power and signal lines in the field are installed at
the same time, additional expenditure shall be considered for cable thickness and
construction. In this development of the signal using a pre-amplification unit and
38
a share in the distance 300meter amplification unit and the distance from the
power supply to minimize signal attenuation on the signal transmission techniques
have been developed.
The technical implementation of the above transmission method between main-
amplified modules and pre-amplifier module can be summarized as follows.
In the case of the main-amplifier module of Fig. 3.10, by supplying voltage of
the sensor through the inductor on signal components, and by providing for action
by the high impedance, it prevents leakage of electric power.
In the case of pre-amplifier module of Fig. 3.11, DC power component arrived
through cable is supplying to the DC/DC convertor which is supplying to pre-
amplifier through inductor, and collected signal by sensor is amplified at OP AMP
and disconnected DC component has been transfer through condenser by nested
on DC signal.
39
Fig. 3.11 Power and signal driver design of pre-amplifier
The signal level trigger module, as shown in Fig. 3.12, uses high speed
comparator that can function with high speed RAW input signal waveform to
input trigger signal to the system when the higher signal level is detected
compared to the reference signal level. This is to use one trigger signal to watch
over various channels of triggers.
40
Fig. 3.12 Signal level trigger module circuit diagram
In case of data acquisition module, the PCI type board of specification below
Table 3.1 is used.
Table 3.1 Specification of data acquisition module
Item Specification
Input channel Analog 8 ch
Input type IEPE type, AC
41
Max. Input Range ± 24 Vdc
Dynamic Range ± 10 Vdc
ADC 14bit, 2.5MSPS
42
Fig. 3.15 AE monitoring hardware block diagram
43
Fig. 3.17 8ch AE system
44
3.5 AE software design
Alarm decision
45
Trend management graph
Fig. 3.19 UI design of main window for real time fault monitoring
The main screen of the real-time fault monitoring program consists of menu
bar, toolbar, channel list, trend graph, time waveform, list of logs, state display bar,
and each screen can be either added or deleted by the user.
Input data range, sampling frequency, storage length, pre trigger, sensor
sensitivity can be set manually.
Also, certain channels can be turned on and off by the program, and the input
signal may be amplified to the amount of set signal. If the condition is not met
with the installed hardware (if the function ordered is not supported), the program
will display an error message.
46
Fig. 3.20 Channel setup window before data acquisition
Fig. 3.20 is setup screen for timing parameter, the threshold to manage the
signal start, Hit Definition Time (HDT) to analyze the measured AE signal, Peak
47
Definition Time (PDT), and Hit Lockout Time (HLT) can be manually set. Also, it
is possible to choose to set the data analysis unit between V/(m/s) and dB.
The set-up can be performed separately within each channel, and the whole
channel can also be set with dragging the mouse.
48
the speaker so that the user is acknowledged the alarm happening situation via
visual and auditory means.
In Fig. 3.19, the left one is the tend graph, and the right side indicates time
waveform data entered in each channel.
Usually for monitoring the real-time data, only the tend data are used, but when
the alarm occurs, the time waveform data are used to detail analyze the cause and
the scale of the alarm.
The lower part of the screen displays a screen of alarm with the information of
data acquisition start, stop, the channel of alarm occurrence and time, and the list
of alarms currently raised is shown in a list.
User-setting localization
49
Thus, user can retrieve and analyze the data anytime, anywhere using the data
obtained in real-time fault monitoring program.
In other words, real-time fault monitoring program is regular running program
which is installed on the main computer where hardware is installed, and through
the hardware, it continues to collect, analyze and store data.
In contrast, fault analysis post-processing program can monitor the fault signal
by connecting to real-time fault monitoring program after being installed on
computer where the user wants to monitor data regardless of the hardware.
In addition, user can make post-processing precision analysis of the data by
retrieving the data that are already stored, and localization may be carried out
again by the user settings.
50
Fig. 3.23 Multi FFT window for fault frequency analysis
Fig. 3.22 is the main window of fault analysis post-processing program which
has almost the same configuration with real-time fault monitoring program. In
51
addition, above screen shows to monitor in real-time whether a fault occurs or not
by accessing real-time fault monitoring program in fault analysis post-processing
program, and real-time trend graphs and bar graphs are displayed in the main
screen.
Fig. 3.23 shows a comparative analysis of the correlation between each signal
when measured data at various points are compared to the same scale. Multi-FFT
graph is easy to compare and analyze frequency analysis results of measured
signal, so it is convenient to compare and analyze the characteristics of the signal
by frequency band.
Fig. 3.24 shows that using the measured data, different kinds of features to
determine the characteristics of fault signal can be calculated. These results can be
displayed on the screen by trend graph, which is called AE feature trend graph.
In this graph, the same features for multiple channels can be analyzed and
different features for a channel can be analyzed. Through AE feature trend graph,
the various interpretations including amplitude, energy, count, duration, rise time,
etc. are supported.
After checking basic tests for the developed system, we carried out the
performance test for the system based on the following three items.
The signal close to the analysis maximum frequency of data acquisition devices
is input by a function generator and obtained from high speed data acquisition
system, and then whether or not data are acquired is assessed.
As analysis maximum frequency = sampling frequency / 2.56 = 3MHz / 2.56 =
1.17MHz, similar signal to 1.1MHz in function generator is input and then the
52
evaluation is performed.
In the measurement results, you can check that the signal of 1.1MHz has been
measured accurately.
The main amplifier input is terminated and then the output value is measured to
evaluate Noise Level. 22dB is the standard value based on 1 ´ 10 -6 V and if
converted to voltage, it is about 12.59µV. It is difficult to measure by general
measurement equipment, so the output signal is measured after 60dB (1000 times)
is amplified in the main amplifier. At this time, the output becomes 12.59mV.
53
Table 3.3 Noise level test result
Channel No Average value Target value Result
1 8.4mV 12.59mV Pass
2 9.7mV 12.59mV Pass
3 8.8mV 12.59mV Pass
4 7.7mV 12.59mV Pass
54
3.7 Conclusion
55
References
56
IV. Applications of Structural Health
Monitoring for Fault Diagnosis
4.1.1 Introduction
57
classification technique based on the signal processing using crest factor and
count rate for normal and abnormal conditions. Lu Xueqin[3] reported a study on
defect the characteristics and running condition of boiler water wall tube by using
scanning system enabling to detect and localize the corrosion and erosion of
complex water wall tube configuration and boiler water wall tube. Peng,
Liansuo[4-6] made study on leaking source by utilizing a variety of algorithms for
leakage signal based on mathematical calculation, Gao[7] made study on the four
major tube leakages through temperature, pressure and flow.
Those studies are the experimental studies applying mathematical algorithms
for limited tube rather than four major tubes and it was a study primarily to
evaluate the leak evaluation, and this cannot present accuracy for the integrated
leakage evaluation and leak location based on actual data for the whole boiler
system.
Whereas, in case of commercially available conventional Boiler Tube Leakage
Detection (BTLD) system[8,9] makes alarm when a signal higher than normal
value is input in the microphone located nearest to the leaking place or acoustic
sensor utilizing accelerometer. It makes the staff in charge take considerable time
to verify whether or not of the leakage and check the location of the leakage after
the stop of power generation. this process causes enormous loss due to the stop of
power generation.
Therefore, a novel leak monitoring technology was proposed by using AE and
which can precisely provide not only the leak occurrences but also 3D localized
coordinates of the entire boiler tube for the efficient maintenance. The idea was
validated by an experiment to a 500MW class thermal power plant.
58
4.1.2 Review of leak theory and BTLD system
Leak theory
59
BTLD System
If there is a leakage in the crucial part locating inside of the boiler such as
superheater, reheater, and economizer, the leakage signal was vibrated and passes
through the gases and hit the inside of water-wall. Also, water-wall leak signals
are transmitted to the waveguide, which is weld on membrane tube. BTLD system
is to detect leak and inform the location of leak as 3D on the structure map when
leak is occurred inside of boiler tube as shown Fig. 4.2.
Fig. 4.2 The principle of boiler tube leak detection method by using compound
sensor for AE and vibration
60
Interface (HMI) as shown Fig. 4.3 and detail function are as follows.
Sensing equipment
Signal conditioner
The pre-amplifier and main-amplifier are developed in order to apply them for
composition signal processing and it performs amplification from several µV to
several mV.
DAS
For DAS, it performs high speed data acquisition and analysis. It consists of
terminal unit which determine the signal level and combined signals, high speed
data acquisition system, and operating server. DAS has a sampling rate of over
3M data per channel.
HMI
As for HMI, it analyzes the input signal from DAS and displays as a 3D point
in boiler structure for leak information based on 3D source location method. It
consists of Server/Client system. HMI was classified by Server/Client, in the case
of server it plays a role of management of all channels of data and client is
connected through network. If a tube leak was detected, it will be displayed by the
61
3D source location method and an announcement will be generated on the monitor.
The 3D location program consists of main and detail displays. In the main it
displays all pipe and water wall, and in detail it displays the Primary Reheater
(PRH), Final Superheater (FRH), Primary Superheater (PSH), and Hanger, Eco
(Economizer), respectively. Specification of BTLD system are summarized as
Table 4.1
Installation
In order to apply the system to a large size power plant, this system needs to be
separately installed such as field, equipment room, and main control room. To
install of sensor for the boiler structure, waveguide is welded on the membrane
tube, which is located in the outside of the boiler structure and then sensor is
mounted on the other side as shown Fig. 4.4.
In general, sixteen to twenty eight sensors are typically needed to cover of
whole boiler structure in the case of 500MW class thermal power plant. In this
study BTLD systems are applied to two kinds of similar type of boiler structures
respectively. First type is 18 sensors are installed as shown in Fig. 4.5. Second
type is 32 sensor are used as shown Fig. 4.8.
62
Fig. 4.5 Location of sensor (18channel)
63
Table 4.1 System configuration of BTLD
Specification of AE system
Title Maker
Description Specification
Vibration
Sensor 20mV/g, ~20kHz Fuji Ceramic
Acoustic Emission
63dB, 150~650kHz (Japan)
1st amplification,
Pre-amp 20/40/60 dB RECTUSON
filter
2~20 &100~600kHz (Korea)
2nd amplification, filter,
Main-amp 0/20/40 dB
RMS/RAW output
2~20 &100~600kHz
High Speed Data 3MSPS/ch , 14bit
DAS
Acquisition System
3D Source
RMS Trend
Location Software
S/W 3D Tube modeling
3D Source location
Input signal from AE sensor carry out feature extraction, feature selection, fault
diagnosis, and finally fault location is discriminated by using source location
algorithm like Fig. 4.6.
Raw data
Raw data is a term for data collected from a source. Raw data have not been
subjected to processing or any other manipulation, and are also referred to as
primary data[12].
Analog Signal Processing
64
Digital Signal Processing
In order to calculation for high speed and large amount of data in digital signal
processing, it perform noise reduction and digital signal processor, which has
function of arithmetic operation, is adapted. In this case, DSP and FPGA is
performed arithmetic operation for AE signal.
Feature Extraction and Selection
When a feature signal, which can identify normal and abnormal condition, is
selected against fault signal, fault condition can be subdivided according to this
feature value. Now, judgment is carried out for the fault through various
correlation diagnosis based on feature value. For instance, in case of leakage
signal, it is important to find RMS for judging of continuous signal, frequency for
bandwidth of center frequency and duration for sustaining time of leakage.
In order to analyze of effective signal, related parametric input values are
required like pressure, temperature, load, and displacement.
As increase of temperature and pressure for the interested object, AE activity is
also increased. This fault correlation analysis method for considering of
environmental factor is basic access method when we detect fault signal
unexpected condition.
65
Basically zone location and time difference of arrival method are used as source
location algorithm.
In zone location, expected fault is located in highest signal output in zone. In
time difference of arrival method, fault is located in constant distance by multiply
time and velocity. Based on this algorithm fault location is displayed 1D, 2D, and
3D.
Source Location
66
4.1.5 3D source location for tube leak
To estimate the location, assuming that the location where many AE events
have been detected may be the fault (corrosion, crack, leakage) location, one point
represents 1 event and the location where cluster is concentrated is understood as
a damaged location. This event signals are displayed as clustering using 1, 2, and
3D source location algorithm. Sometimes this signal has location error due to
unexpected working condition.
To compensate of location error, we need to study of discrimination between
normal and abnormal condition by using actual condition data. Finally, fault
location is indicated as clustering with multi point.
Fig. 4.7 shows 3D source location and 3D modeling flow respectively. In left
figure, it explain 3D source location process using clustering from the raw data
files. In right figure, it explain 3D modeling processing from the In-site survey.
67
In order to apply of 3D source location for the plant structure, following 3D
source location and 3D modeling process is performed simultaneously.
3D modeling
68
(b) 2D modeling for boiler structure with sensor position
Fig. 4.8 2D & 3D modeling for boiler structure before source location
3D source location
In order to increase of accuracy for leak location, total 32 channels are used as
shown Fig. 4.8. In detail, 10channels for header part to cover of z direction and 22
channels for wall part to cover of x and y direction are installed.
3D source location is simulated using Soot Blower (SB)[13]signal, that has
very similar characteristic for leak signal. The SB is a system for removing the
soot that is deposited on the furnace tubes of a boiler during combustion. Steam
with 5 to 10 bar pressure is normally used as a medium for blowing away the soot.
In operation, the retractable SB rotates as it is inserted and retracted out of the
boiler. Two opposed nozzles direct the working fluid in a helical pattern as the
soot blower advances and withdraws ash as shown Fig. 4.13.
In this study this SB signal was used to find a fault as 3D source location
69
because SB signal is similar to actual tube leak signal during plant working
condition. Also, if actual leak is started inside of boiler tube, we can assume that
the signal level is higher than SB signal.
Simulation and error
70
(a) 3D Simulation (SB101) (b) DB based simulation (SB101)
71
Fig. 4.10 shows characteristic DB of signal attenuation. When signal source is
generated near by CH1, amplitude of CH1 is indicated as the first highest level
and second level is CH3, third level is CH5.
Also, when signal source is generated near by CH12, amplitude of CH12 has
highest level. In this way, we can assume that attenuation ratio of signal for this
structure.
To discriminate background noise and actual leak signal, this study applied hit
and frequency based AE signal features such as duration, RMS trend, count,
energy and frequency.
72
For example, if soot blower time during boiler operation is within 6 minutes,
amplitude at the start time of soot blower is rising, RMS trend keeps
characteristics of the M-shaped curve, and amplitude at the end of soot blower
will be terminated after increase. In this case, Duration time becomes 6 minutes
and Energy value at corresponding time rises, and frequency characteristics will
be found in 5 ~ 20 kHz range. Based on these AE signal features, we can
discriminate actual leak signal among the background noise.
Discrimination of background noise and leak signal
In general, normal background noise level during normal working condition has
50mV. In this case caution level is set as two times the normal value 100mV and
alarm level is set as two times the caution level 200mV as shown in Fig. 4.11.
Soot blowers at No. 90, 99, 100, and 115 are used to test and verify 3D source
location during plant working period. Soot blower No. 90 is on going condition
during normal working period, source location result is displayed as 3D on the
map of boiler structure as shown Fig. 4.15.
73
Soot blower signal was greatly influenced by baffle plate to prevent of acoustic
resonance as shown Fig. 4.12 (a) and (b). In case of (a) without baffle plate, signal
feature during soot blower decreased to direction of the middle area of boiler
structure and increased to direction of near area of boiler structure. That means the
signal has attenuation characteristic to the z direction also.
In case of (b) with baffle plate, signal is rapidly decreased to the middle area of
boiler structure.
Leak test using pressure vessel during overhaul period
Fig. 4.14 shows test result with 200 bar gas filled pressure vessel during
overhaul period. In order to compare with soot blower test, this test is performed
at the same location of the soot blower.
In the case of using 200 bar gas filled pressure vessel signal, all 4 kinds of
different location test results are coincidence with soot blower. This test result are
summarized as Table 4.2. Based on this test result we can verify respectively 3D
source location during working period and overhaul period.
(a) Signal feature without baffle plate (b) Signal feature with baffle plate
Fig. 4.12 Signal feature with and without baffle plate using soot blower
74
(c) Outside shape of soot blower (d) Inside shape of soot blower in boiler
Fig. 4.13 Outside and inside shape of soot blower
(a) Leak test inside of boiler structure (b) 200 bar gas filled pressure vessel
Fig. 4.14 Pressure vessel test during overhaul period
75
(a) Location of soot blower No. 90 (b) 3D source location result
(c) Location of soot blower No. 110 (d) 3D source location result
Fig. 4.15 3D source location result using soot blower No. 90 and No. 110
76
Fig. 4.16 Location of soot blower to test of 3D source location
77
Leak detection and 3D source location in thermal power plant
We can verify this system when actual tube leak was occurred in thermal power
plant with 500MW class. In this case total 28 channel is assigned to find leak
location. (18 channels are located in tube part and 10 channels are located in wall
part )
Fig. 4.18 shows RMS trend when actual tube leak was started inside of boiler
structure. In this figure, trend data of related channels(CH20, 22, 24, 25)are
changed. In order to detail analysis Zoon In leak start point, we can find leak start
point and 20 days later the tube was ruptured finally power plant was shut down.
In case of signal level of leak start (Zoon In A in (b)) is changed from 80 dB in
normal condition to 88dB in leak condition. In case of signal level of tube rupture
(Zoon In B in (b)) is changed to 100dB.
Fig 4.19 shows 3D source location result with multi point cluster to find
estimated leak location from the large plant structure. That means multi point
represent leak alarm continuously and estimate leak location. In clustering we can
check the total 50 points of clusters. 10 point is generated from the upper side
channel 16, 14, 12 and 40 point is generated from near area channel 21, 24.
According to the plant manager, actual leak location is correspond with the
cluster location.
Test result
With this study, it was confirmed that, when there is boiler leakage at the
thermal power plant, it is possible to identify leaking point by 3D way and with
this, power generation stop time can be reduced and equipment efficiency can be
increased. Summary of the results are as follows.
This experiment provided location of the leakage point by 3D way by utilizing
structure borne type compound sensor for vibration and acoustic emission at the
500MW class thermal power plant compare with the simple warning signal made
78
at the sensor located at the closest location to the leakage when leakage was
generated.
Power equipment downtime resulted from leakage can be reduced and power
generation efficiency can be maximized by applying 3D source location which is
improved from 1, 2D source localization.
After generating similar leakage signal in the furnace by utilizing 200bar
charged pressure vessel during overhaul period, it was confirmed that actual
location happened and the result of 3D source location were consistent.
(a) all channels RMS trend data (b) leak channels RMS trend data
79
Fig. 4.19 3D source location result when actual leak was occurred
After generating signal of within 10bar by utilizing soot blower signal which is
the most similar to actual leakage signal in the noisy environment during plant
operation, it was confirmed that the location actually happened and location of 3D
source location were consistent.
It is necessary to make effort to reduce the margin of error regarding the 3D
source location by establishing various data base for the leakage signals.
As a result of test and evaluation utilizing soot blower during working period,
trial leakage locations resulted from signal generation were displayed precisely on
the 3D source location software at 4points and when it was compared with the
result of the verification utilizing soot blower during operation and the test result
using pressure vessel during overhaul period.
Finally, based on this study, we can verify 3D source location when actual tube
leak was occurred and early detection of leak start point before tube was rupture.
80
4.2 Structural integrity monitoring for seamless pressure vessel
4.2.1 Introduction
Acoustic Emission Test (AET) was prefer to other kinds of nondestructive test
method because it support real-time test during working condition and without
disassemble in case of cylinder, which was mounted in side of the car. In 1983 the
U.S. Department of Transportation (DOT) began to allow use of acoustic emission
(AE) examinations in lieu of hydrostatic test to ensure public safety. AE data are
recorded in the linear location while cylinders are filled with gas and structural
health of pressure vessel is evaluated as safety level. Usually, AE examination and
secondary local inspection like Ultrasonic Test (UT) are accomplished without
disassembly of cylinder bundles.
Conventional trends on the study of pressure vessel are as follow.
Blackburn[15] made study on safety level for pressure vessel, which is located on
tube trailer by applying ASTM E 1419-96. Fultineer and Michell[16] proposed
safety standards for Natural gas Vehicle (NGV) as repeat test within 3 years, 1
year, and remove immediately by applying ASTM E07043-95/1. Akhtar and
Kung[17] made study on safety level for gas filled type 2 vessel during loading,
hold, and unloading period using 10 set of pressure vessel over 4 years used.
However, these kinds of previous studies are not provide good guide line for
structural integrity test because it is difficult for general person to test and
evaluate with related code and standards. In this study, development of structure
integrity monitoring system for seamless pressure vessel using AE and give a
safety standard for Type 1 and Type 2 by determining normal and abnormal
condition. The result of Type 1 and Type 2 test using acoustic emission show that
effectively discriminate between undamaged and damaged pressure vessel.
81
4.2.2 Structure of seamless pressure vessel
Test procedure
Testing, inspection procedures and methods of Type 1 and Type 2 are as below.
1) Two sensors are used to test pressure vessel. One is installed on the pressure
vessel wall, another is placed apart at the ends of the container on the shoulders
using magnetic holder and couplant like Silicone grease.
82
2) To test environmental setup and timing parameter is as follows. Threshold:
46 dB (40 dB amplified), HDT: 800 ms , PDT: 300 ms , HLT: 1000 ms .
3) Pencil Lead Break (PLB) is performed and check the detectable distance and
attenuation as dB after sensor is attached on the pressure vessel.
4) In Type 1, The AE examinations should be performed with pressurization
rates that allow vessel deformation to be in equilibrium with the applied load. In
this test, gas is pressurized up to 1⁄3 of service pressure at 110%. 2min hold at
60bar and 10 min hold at 165bar (110% of service pressure) and acceptance
criteria is check as AE event.
5) In Type 2, there are two kind of test method Slow-fill and Fast-fill. In this
test Slow-fill method is adapted, which represent 2min hold at 50% of test
pressure and 10min hold at 110% of test pressure and acceptance criteria is based
on cumulative AE count during b and c as shown Fig. 4.22, is applied.
83
10,000~50,000 it is classified to one to be re-inspected within a year. Fig. 4.22 is
the inspection method about Slow-fill applied in this study.
The specification of cylinder for Type 1 vessel is shown in Table 4.4 and it has
been tested according to ASTM 1419 standard. For site testing of Type 1 vessel, a
vessel which capacity is 113 liter and was rejected due to UT defect in production
line of ENK was used. Using cycling tester pressure was applied and then released
repeatedly using hydraulic pressure so that fault occurrence is induced by
cumulated fatigue as below. Based on 1,000 cycle of frequency by repeated
fatigue, ration that accumulated occurrence of AE count is summarized in Table
4.5, and it was confirmed that accumulative frequency by repeated testing has
been confirmed as shown in Fig. 4.26.
84
Table 4.3 Specification of AE system
Description Specification Remark
AE sensor 140kHz (resonant type)
40dB (built-in preamplifier)
Amplification Unit 50~300kHz filter
28V power supply
DAS 14bit, 3MSPS
Test code ASTM E 1419-02 Type1
ASTM E 2191-02 Type2
Application result of Type 1
Feature that is similar to crack signal was detected in 11,000 cycle fatigue
repeat, and possibility of crack was confirmed through UT so pressure testing has
been carried out, and as the result 4 similar crack signals were received so it was
judged as minor crack signal. As in Fig. 4.26, frequency of signal occurrence has
been increased in pressure section after 8,000 cycles so vessel came very unstable
after 8,000 cycles and it caused crack signal and it was observed that crack was
developed to leakage by fatigue degree through AE signal.
85
Fig. 4.22 Test method for Type 2
86
Table 4.5 Cycle count vs cumulative hit for Type 1
Cycle count Average Standard Cycle count Average Standard
(time) time deviation (time) time deviation
0~1,000 3.91 1.86 7001~8,000 5.07 1.27
1001~2,000 4.14 1.43 8001~9,000 5.95 1.54
2001~3,000 5.01 1.33 9001~10,000 10.31 2.16
3001~4,000 4.66 1.19 10001~11,000 13.65 1.98
4001~5,000 4.6 1.20 11001~12,000 16.81 2.18
5001~6,000 5.41 1.34 12001~13,000 21.22 2.30
6001~7,000 4.69 1.26 13001~14,000 24.28 1.85
(a) Leak start during cycle test (b) AE hit vs cycle count
Fig. 4.24 Cycle test for Type 1
Fig. 4.24 (a) shows actual leak during cycle test and (b) show cumulative AE
hit. As increase cycle count, pressure vessel can unstable and might be damaged.
In this case, as fatigue is accumulated for pressure vessel, as a result fault like leak
is started. Based on cycle test, we can estimated that condition of pressure vessel
is normal or abnormal. Fig. 4.25 (a) shows test result of Type 1. To verify AE test
result, UT test is also performed and fault signal is detected.
87
(a) AE test result (b) UT test result
Fig. 4.25 AET and UT test result for Type 1 pressure vessel
88
Fig. 4.28 Test result of Type 2
The specification of cylinder for Type 2 vessel is shown in Table 4.6. 4 sets of
NK CNG Type 2 vessels were provided from NK for pneumatic testing. For safety
placed Type 2 vessel inside of 5T thickness protection container configuring
testing environment as shown Fig. 4.27.
Two undamaged pressure vessels and two damaged vessels with 600 bar
89
hydraulic pressure are prepared to test. In Slow-fill method, 2min hold at 110bar
and 10min hold at 228bar (110% of service pressure) and acceptance criteria is
check as AE event. AE test result, AE activity is increased in damaged pressure
vessel Test 6 and Test 7 respectively as shown Fig. 4.28.
Application result of Type 2
90
4.3 Structural health monitoring of blast furnace in steel mill
4.3.1 Introduction
NKK in Japan, attempt to early detect of channeling for blast furnace by using
the acceleration sensor, AE sensor, microphone on back side of cooling container
on structure of large steel mill as shown Fig. 4.29 [21]. AE sensor out of 3 sensors
had been reacted firstly showing the prognostic of fault like pressure change on
shaft, wind pressure drop and low gas usage rate. For the fastest sensed signal of
shaft pressure variation, AE sensor had detected the change in furnace 10 to 15
minutes in advance. It showed that prediction of fault on equipment was possible.
However, previous study just provide general condition of the surface for blast
furnace structure. In addition, this system does not give us quantitative guide line
of early fault detection of blast furnace. To do this, on-line real time monitoring
system using AE is applied to large structure in steel mill and give us fault
diagnosis and prognosis technique for crack in steel shell and leak in blower.
91
Fig. 4.29 Early fault detection for blast furnace using AE sensor
Blast furnace produces cast ion through reaction with ore and coke and is
surrounded with steel to withstand pressure (0.4 ~ 2.5 Kg/㎠) in furnace. This
steel shell is protected by firebricks. Inside of firebrick there is cooling system to
prevent loss by temperature increase so crack on steel shell shall be monitored.
Blower blows hot air into ballast furnace for reaction of coke and ore. Several
blowers are installed at lower part of furnace at same distance and high
temperature air and fine powder coal fuel are fed through blowers for burning to
generate high temperature. Blower is important in producing fused iron so leak
monitoring is required.
In case of large and complex type structure, fault signal can be sensed by
waveguide which is connected with steel shell on one side, and connected with
AE sensor on the other side. In steel shell, main purpose of monitor is to detect
and predict potential crack signal before explosion accident is occurred. In blower,
main purpose of monitor is to detect of leak signal with a rigid waveguide for
blower, which is located deeply inside of furnace as shown Fig. 4.30.
92
Fig. 4.30 Structure of blast furnace
AE System configuration
93
AE system setup
94
furnace various AE features (Energy, Count, RMS, Time waveform, FFT) analysis
is available for monitoring unexpected signal caused by crack on steel shell.
95
System performance verification in steel shell by using BB gun
In blower part, sensor is installed at top side of waveguide with a long length.
In this case, scratch test is performed blower No. 25 and No. 26 at three times in
10 sec and by scratching on the wave guide with a steel bar and the signal
response is as shown Fig. 4.34 (b).
96
4.3.5 Feature extraction and classification of fault signal
97
(a) 1st -waveform result (b) 1st – FFT result
98
(a) 1st -waveform result (b) 1st – FFT result
99
Rise time, duration, frequency analysis
Fig. 4.37 shows test result of rise time, duration, and FFT for BB gun and water
drops signal at AE 4-1. In rise time analysis, BB gun signal is shorter than water
drops signal. In duration analysis, BB gun signal is longer than water drops signal.
In frequency analysis, BB gun signal has characteristic frequency range from 20
to 200kHz and water drops signal has range from 100 to 200kHz.
(a) Rise time and duration (BB gun) (b) FFT (BB gun)
(c) Rise time and duration (Water drops) (d) FFT (Water drops)
Fig. 4.37 Rise time, duration, and FFT result at AE 4-1
100
Fig. 4.38 shows test result of rise time, duration, and FFT for BB gun and water
drops signal at AE 4-2.
In rise time analysis, water drops signal is shorter than BB gun signal. In
duration analysis, BB gun signal is longer than water drops signal. In frequency
analysis, BB gun signal has characteristic frequency range from 20 to 200kHz and
water drops signal has range from 100 to 200kHz.
(a) Rise time and duration (BB gun) (b) FFT (BB gun)
(c) Rise time and duration (Water drops) (d) FFT (Water drops)
Fig. 4.38 Rise time, duration, and FFT result at AE 4-2
101
Fig. 4.39 shows test result of rise time, duration, and FFT for BB gun and water
drops signal at AE 4-3.
In rise time analysis, water drops signal is shorter than BB gun signal. In
duration analysis, BB gun signal is longer than water drops signal. In frequency
analysis, BB gun signal has characteristic frequency range from 20 to 200kHz and
water drops signal has range from 100 to 200kHz.
(a) Rise time and duration (BB gun) (b) FFT (BB gun)
(c) Rise time and duration (Water drops) (d) FFT (Water drops)
Fig. 4.39 Rise time, duration, and FFT result at AE 4-3
102
Comparison of BB gun signal and water drops signal
We can summarize analysis result of rise time, duration, and frequency for BB
gun and water drops as Table 4.10.
In rise time average analysis, water drops signal has shorter than BB gun signal.
Average value of rise time, BB gun signal has approximately two times longer
than water drops signal. Average value of duration, BB gun signal has also
approximately two times longer than water drops signal. In waveform pattern
analysis, water drops signal has fast speed with a short wave length.
In FFT analysis, BB gun has frequency range from 20kHz to 100 kHz and
water drops has frequency range from 100kHz to 200kHz.
Based on above test result, we can discriminate crack signal during lots of
water dropping condition like waterfall in order to rapid cooling for the outside of
blast furnace.
Table 4.10 AE rise time and duration of BB gun and water drops
Sensor Rise time [ms ] Duration [ms ]
BB gun Water drops BB gun Water drops
AE 4-1 0.005 0.008 0.104 0.037
AE 4-2 0.013 0.007 0.073 0.047
AE 4-3 0.013 0.004 0.053 0.037
Average 0.010 0.006 0.077 0.040
Feature extraction
In order to apply feature extraction, water drops signal and BB gun signal are
compared with AE features. BB gun test is performed at AE 4-1 and AE 4-4 and
well expressed AE features are calculated. To do this, compare with water drops
signal at AE 4-1 and BB gun signal at 4-1, 4-2, 4-3 and then check well expressed
103
AE features. In AE 4-4, it also test with a same method. In every case, energy
parameter is selected as notable AE feature.
Table 4.11 Water drops signal at AE 4-1
Time
AE features Average
1st 2nd
Peak[V] 0.41 0.505 0.4575
Duration [ms ] 0.296 0.141 0.2185
Risetime [ms ] 0.002 0.008 0.005
Count 14 14 14
Energy[aJ] 0.94289 1.6984 1.320645
Energy count 30 25 27.5
RMS[V] 0.5644 0.10975 0.083095
104
Risetime [ms ] 0.113 0.137 0.125
Count 66 84 75
Energy[aJ] 19.8882 32.8869 26.38755
Energy count 94 125 109.5
RMS[V] 0.16134 0.1809 0.17112
105
Time
AE features Average
1st 2nd
Peak[V] 2.134 2.742 2.438
Duration [ms ] 0.783 1.144 0.9635
Risetime [ms ] 0.057 0.025 0.041
Count 66 101 83.5
Energy[aJ] 46.7696 140.8715 93.82055
Energy count 93 123 108
RMS[V] 0.2444 0.35091 0.297655
We can verify energy parameter is notable feature during the test of water drops
and BB gun signal. In AE 4-1, 4-2, 4-3 in the same group, BB gun around AE 4-1,
4-2, 4-3 to generate a signal using a similar case of cracks, the energy value was
prominent. Located closest to the source in the order determine the size of the
energy value(4-1 > 4-2 > 4-3).
Signal characteristics of the AE4-4, 4-5 in the group had characteristics similar
106
to the AE 4-1. This results are described Table 4.18 and 4.19.
Table 4.18 Water drops signal and BB gun signal at AE 4-1, 4-2, 4-3
Water drops
BB gun (Average)
AE features (Average)
AE 4-1 AE 4-1 AE 4-2 AE 4-3
Peak[V] 0.4575 3.802 1.0675 0.329
Duration [ms ] 0.2185 1.595 0.8445 0.4755
Risetime [ms ] 0.005 0.020 0.125 0.845
Count 14 96.5 75 40.5
Energy[aJ] 1.320645 233.77955 26.38755 2.3351
Energy count 27.5 120.5 109.5 67.5
RMS[V] 0.0083095 0.39006 0.17112 0.070017
Table 4.19 Water drops signal and BB gun signal at AE 4-4, 4-5
Water drops BB gun (Average)
AE features (Average)
AE 4-4 AE 4-4 AE 4-5
Peak[V] 0.4595 2.438 0.259
Duration [ms ] 0.592 0.9635 0.2445
Risetime [ms ] 0.0235 0.041 0.051
Count 36 83.5 22
Energy[aJ] 7.68565 93.82055 1.25388
Energy count 58 108 34.5
RMS[V] 0.0947875 0.297655 0.070178
107
4.3.6 Crack detection and leak monitoring of blast furnace
108
shown in Fig.4.40. Based on this actual data, we can confirm that AE energy
parameter is validate when we detect crack signal on steel shell and estimate
expected position.
109
Fig. 4.42 Change of AE energy trend during crack propagation
110
(a) External shape of blower (b) Blower No.
111
4.4 Conclusion
Complex and large scaled structure in power plant, source location technique is
required to find a fault in limited time.
In pressure vessel, 1D source location is applied and verified to discriminate
normal and abnormal pressure vessel and give a good guide line with easily.
In boiler tube leak detection, 3D source location is applied and verified by
detecting of actual tube leak in large scaled structure. Based on 3D source location
technique with optimized database, effectiveness of system performance is
verified and fully showed possibility of replacement the conventional system.
To estimate and monitor of crack propagation for steel shell in blast furnace, on
line AE system is applied to the steel mill. AE Energy parameter is applied to
discriminate crack signal by using AE feature extraction and it is verified by
prognosis of crack propagation when actual crack is detected. Based on this study
result, we can easily apply real application.
112
References
[1] EPRI International Conference, Boiler Tube and HRSG Tube Failure and
Inspections, Calgary, Alberta, Canada, Richard Coutant, Progress Energy,
October 16-18.
[2] Jirapong Lim, Tonphong Kaewkongka, Leakage Evaluation of heating coil
tube in thermal oil boiler by using Acoustic Emission and data classification
technique, I2MTC 2008 - IEEE International Instrumentation and
Measurement Technology Conference, Victoria, Vancouver Island, Canada,
May 12-15, 2008.
[3] Lu Xueqin, Liu Gang, Luan Shangqing, The development of the Boiler Water
Wall Tube Inspection, DRPT2008 6-9 ,Nanjing China, April 2008.
[4] Peng Wang, Liansuo An, Genshan Jiang, Guoqing Shen and Yongxing, Boiler
Tube Leakage Acoustic Localization Error Analysis, Proceedings of the 8th
World Congress on Intelligent Control and Automation, Jinan, China, July 6-9
2010.
[5] Liansuo An, Peng Wang, Guoqing Shen, Jie Shi and Qiang Feng,Boiler Tube
Leakage Location Optimization via Adaptive Gaussian Mutation, Proceedings
of the 8th World Congress on Intelligent Control and Automation, Jinan,
China, July 6-9 2010
[6] Peng Wang, Liansuo An, Guoqing Shen, Jie Shi and Yongxing L, Boiler Tube
Leakage Acoustic Localization Base on AGA, Proceedings of the 8th World
Congress on Intelligent Control and Automation, Jinan, China, July 6-9 2010.
[7] Gao Jianquiang, Yin Xianglei, Hou Zhifu, Research on Fuzzy Recognition
Method of Boiler Four-tube Leakage, the 2nd International Conference on
Intelligent Control and Information Processing, July 25-28, 2011.
[8] http://www.triple5industries.com/
[9] http://www.proconeng.com/mainfiles/boilerleak.html
113
[10] John L. Loth, Gary J. Morris, Acoustic Detecting and Locating Gas Pipe
Line Infringement, 9th Quarterly Report, National Energy Technology Laboratory
Strategic Center For Natural Gas (SCNG), October 31, 2004.
[11] Enviroacoustic ABEE, EL. Venizelou 7 & Delfon, 14452 Metamorphosis,
Athens, GREECE, Acoustic Emission leak detection of buried pipeline,
Janese Society for NDI, 2008.
[12] http://en. wikipedia.org/wiki/Raw_data.
[13] http://en.wikipedia.org/wiki/Soot_blower
[14] http://en.wikipedia.org/wiki/Matlab
[15] Blackburn, P. R., Periodic AE Re-tests of Seamless Steel Gas Cylinders,
Acoustic Emission: Standards and Technology Update, ASTM STP 1353, S. J.
Vahaviolos, Ed., American Society for Testing and Materials, West
Conshohocken, PA, (1999).
[16] Fultineer, Jr., R. D. and Mitchell, J. R., Field Data on Testing of Natural Gas
Vehicle (NGV) Containers Using Proposed ASTM Standard Test Method for
Examination and Gas-Filled Filament-Wound Pressure Vessels Using
Acoustic Emission (ASTM E070403-95/1), Acoustic Emission : Standards
and Technology Update, ASTM STP 1353, S. J. Vahaviolos, Ed., American
Society for Testing and Materials, West Conshohocken, PA, (1999).
[17] Akhtar, A., and Kung, D., Acoustic Emission Testing of Steel-Lined FRP
Hoop-Wrapped NGV Cylinders, Acoustic Emission : Standards and
Technology Update, ASTM STP 1353, S. J. Vahaviolos, Ed., American
Society for Testing and Materials, West Conshohocken, PA, (1999).
[18] ANSI/CSA NGV2(American National Standard for Natural Gas Vehicle
Containers), Article 1.2, 2007.
[19] ASTM E 1419-02b, Standard Test Method for Examination of Seamless, Gas
Filled, Pressure Vessels Using Acoustic Emission ASTM, 2002.
[20] ASTM E 2191-02b, Standard Test Method for Examination of Gas-Filled
114
Filament-Wound Composite Pressure Vessels Using Acoustic Emission
ASTM, 2002.
[21] Hitoshi Kawata, 1 Investigation on the Mechanism of Channelling in
Fukuyama No.5 Blast Furnace, NKK Vol79, 1993.
[22] ASTM E 2374-04, Standard Guide for Acoustic Emission System
Performance Verification1, ASTM, 2002.
115
V. Conclusions
116
for analyzing fault signal. Processes of analog signal and digital signal processing
were carried out individually and AE feature which is used in final fault diagnosis
is classified in 4 features. This representative 4 features are hit based features,
time driven features, combination features and frequency features and they are
defined by 19 kinds of feature.
It was confirmed that fault judgment and classification criteria may vary by
applying correlation diagnosis for various fault examination of specific object.
Clustering is made according to occurrence frequency of fault signal generated
from object. By applying location estimation algorithm, 1D, 2D and 3D location
is estimated and visualized fault judgment. However location estimation error is to
be improved through correcting characteristic DB base signal of final site signal.
The measuring systems developed in this thesis have been applied in
monitoring boiler leak in thermal power plants, structural integrity monitoring of
pressure vessel, structural health monitoring for blower leak and crack on steel
shell in ion mill so that its utility value could be confirmed. To detect boiler leak,
on-line real time measurement system was applied arranging optimized sensors
according to complicated shape boiler structure and 3D location estimation
method was applied for fault diagnosis. In the application of health evaluation for
pressure vessel, fatigue repeat testing were applied to Type1 and Type 2 vessel
and health evacuation was carried out by applying 1D location estimation
technique against crack signal occurred in pressure sustaining section.
The condition monitoring method based on feature value for the fault in crack
and leak in power generation facility was applied in monitoring blower leak and
crack of steel shell in iron mill, and its effectiveness was evaluated comparing
with signals occurred when steel shell was abnormal with signal from normal
condition. Also, sensor and measuring parameters were proposed to monitor
blower leak.
In order to increase reliability of fault diagnosis, construction of fault DB and
117
pattern recognition are continuously studied for the future work.
In fault DB, notable and well response AE features are defined from the various
data when fault is occurred from the object and with this result fault database
should be established.
In pattern recognition, change of pattern and prognosis technique according to
different kinds of fault are adopted based on fault DB.
To finalize of fault diagnosis based on intelligent DB, precise fault diagnosis
and based on previously stored data, setup for early fault detection system and
adoption of intelligent algorithm are required to diagnosis automatically.
118
국문요약
119
결함신호의 해석을 위해서는 음향방출 신호의 처리 및 특징에 대한
구분이 필요하다. 신호처리의 경우 아날로그 신호 및 디지털 신호처리
를 각각 수행하고 최종 결함해석에 사용되는 AE feature 를 크게 4 가지
인 Hit based features, time driven features, combination features,
frequency features 로 구분하고 총 19 종류의 특징으로 정의하였다.
120
Acknowledgements
My first step with Intelligent Mechanics Lab members in 2007 is a great honor
for me to working with and to be surrounded with great member.
I sincerely appreciate two professor Bo-Suk Yang and Dong-Myung Bae. My
first Prof. Bo-Suk Yang who is leaded me with passion and love. He taught me as
a scholar with a latest knowledge and trained as a leader in many ways from 2007
to March 2012. I will always keep in mind all his passion, spirit, effort, guidance,
and teaching method.
After he passed away, my second Prof. Dong-Myung Bae willing to accept and
guide me with moral support and humane consideration even if he has a provost
duty with busy schedule.
My appreciation is extended to Prof. Jong-Kyu Lee, Prof. Seon-Jin Kim, Prof.
Sung-Yong Bae, Prof. Byoeng-Keun Choi. They examined my thesis and gave me
valuable comments and suggestions. I would like to give thanks to Prof. In-Pil
Kang. He helped me to submit international journal.
Specially, I would like to thank our Intelligent Mechanics Lab members. Dr.
Min-Chan Shim, Dr. Jong-Duk Son, Gang-Min Lim, So-Hwan Lee. They gave me
many helps with a good relationship.
I would like to thanks to working with RECTUSON Company and member Mr.
S. Kim, Mrs. J.N. Kang. They give me a confidence as a foundation member.
Finally, I would like to thank my parents, sister, and brother for their
encouragement over the years. My brother Dong-Ryul Kim he trained me a leader
with qualification and ability and I thanks for elder brother’s wife with a warm
heart.
Especially, I give my thesis to wife Mrs. Lee, son Sun-Gyun and daughter
Chae-Young. With their support and help, I can overcome hard process of study. I
will always thanks for my family’s endless love.
121
감사의 글
122