Elevator Design

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

JJ

JJ


Basic Specifications and Important Information
① on Elevator
② Planning Hoistway width: X X
X

①③
AA

Hoistway depth: Y
Car internal

Horizontal Dimensions <1-Door 1-Gate>



<1-Door 1-Gate> <1-Door 2-Gate>


width: AA

BB

BB
Car internal

Y
depth: BB

Y
AA


Rated Counter- Car internal Entrance Minimum hoistway
Code Number of Door


capacity weight dimensions(mm) width (mm) dimensions (mm)


number persons type Hoistway Plan Entrance
Elevation Hoistway Plan Elevation
(kg) position AA x BB JJ X xY width: JJ
JJ
Hoistway width: X X
P24 24 1800 2350 ×1600 2900 × 2290 X JJ
Rear 1200
CO 2350 ×1700 2900 × 2390
Hoistway width: X X
P27 27 2025 1100 2570 × 3080
Side 1500 × 2700 AA

Hoistway depth: Y
2S 1300 2520 × 3150 Car internal
width: AA

BB
P30 30 2250 Rear 2350 ×1900 1200 2900 × 2590

BB
Car internal

Y
CO

depth: BB

Y
1100 2820 × 3080 AA
Car internal
P33 33 2500 Side 1800 × 2700

Hoistway depth: Y
width: AA AA

Overhead: OH

Overhead: OH
Overhead: OH

Overhead: OH
2S 1300 2820 × 3150

Y

BB
<1-Door 2-Gate> Entrance

Car internal
width: JJ

depth: BB
JJ

Entrance height: HH
Entrance height: HH

Entrance height: HH
Entrance height: HH
2200 (Standard)

2100 (Standard)
2200 (Standard)

2100 (Standard)
JJ

Ceiling height

2200 (Standard)

2100 (Standard)
Ceiling height

2200 (Standard)

2100 (Standard)
Shown for CO doors

Ceiling height
Ceiling height
Rated Counter- Car internal Entrance Minimum hoistway
Code Number of Door Counterweight rear drop
capacity weight dimensions(mm) width (mm) dimensions (mm)
number persons type Entrance
(kg) position AA x BB JJ X xY Hoistway width: X X
X width: JJ JJ

CO 1100 2570 × 3154

④ ⑤
P27 27 2025 1500 × 2600 Shown for CO doors
2S 1300 2520 × 3298
Side AA Counterweight side drop
CO 1100 2820 × 3154

Hoistway depth: Y
Car internal
P33 33 2500 1800 × 2600 width: AA

BB
2S 1300 2820 × 3298

BB
Car internal

Y
depth: BB

Y
Hoistway width: X AA X
[ Terms of the table ]
• The contents of this table are applied to standard specification only. Please consult our local agents for other specifications.


• Rated capacity is calculated at 75kg per person, as required by EN81-1.


Entrance
width: JJ

Travel: TR

Travel: TR
• CO: 2-panel center opening doors, 2S: 2-panel side sliding doors.

Travel: TR

Travel: TR
JJ Car internal

Hoistway depth: Y
width: AA JJ AA
• Minimum hoistway dimensions (X and Y) are after waterproofing of pit and do not include plumb tolerance.
Shown for 2S doors

④ ⑤
• Minimum hoistway dimensions (X and Y) should be increased if fireproof landing door is required.

Y
Counterweight side drop

BB
Floor to floor height

Floor to floor height


height

Floor to floor height


floorinternal
depth: BB
Vertical Dimensions <1-Door 1-Gate & 1-Door 2-Gate> Hoistway width: X X
X

Floor to Car
Hoistway width: X X
Minimum AA Entrance
Maximum Minimum Minimum

Hoistway depth: Y
Car internal width: JJ JJ
Rated speed Rated capacity Maximum travel overhead (mm) width: AA

BB
number OH pit depth (mm) floor height Shown for 2S doors

BB
Car internal

Y
(m/sec) (kg) (m)

depth: BB
of floors PD (mm)

Y
AA
Counterweight side drop

Pit depth: PD

Pit depth: PD
Pit depth: PD

Pit depth: PD
Car internal
1D1G 1D2G

Hoistway depth: Y
width: AA AA

1800 —

Y
Entrance

BB
~2025 4450 1630 width: JJ

Car internal
JJ

depth: BB
1.0 4220
~2250 — JJ

④ ⑤
~2500 4450 1730
Shown for CO doors
1800 —
Entrance
Counterweight side drop
width: JJ JJ
~2025 4610
1.6 60 22 4380 1730 2500 Note:
~2250 —
Hoistway width: X X
• The layout (position of traction machine, etc.) differs depending on capacity. Note: The layout (position of traction machine, etc.) differs depending
~2500 4610
1800 — • Elevation for counterweight rear drop is slightly different from this figure. on capacity.
~2025 4670
1.75 4440 1770
~2250 — Car internal
Applicable Standards

Hoistway depth: Y
width: AA AA
~2500 4670
The ELENESSA complies with EN81-1. For details of compliance with other national regulations, please consult our local agents.

Y
[ Terms of the table ]

BB
Car internal
depth: BB
• The contents of this table are applied to standard specification only. Please consult our local agents for other specifications.
• Minimum overhead (OH) and minimum pit depth (PD) should be increased when the travel is over 30m.

④ ⑤
• Some specifications require more than 2500mm as a minimum floor height. Please consult our local agents if the floor height is less than entrance height HH + 700mm,
and the elevator is 1-Door 2-Gate. Entrance
width: JJ JJ

Hoistway width: X X

Work Not Included in Elevator Contract Elevator Site Requirements


The following items are excluded from Mitsubishi Electric’s elevator installation work, and are therefore the responsibility of the building owner or general
Car internal
• The temperature of the elevator hoistway shall be below 40˚C.
• The following conditions are required for maintaining elevator performance.
Hoistway depth: Y

width: AA
contractor: AA

• Architectural finishing of the walls and floors in the vicinity of the entrance hall after installation has been completed.

Y
a. The relative humidity shall be below 90% on a monthly average and below 95% on a daily average.
BB
Car internal
depth: BB

• Construction of an illuminated, ventilated and waterproofed elevator hoistway. b. Prevention shall be provided against icing and condensation occurring due to a rapid drop in the temperature in the elevator hoistway.
• A ladder to the elevator pit. c. The elevator hoistway shall be finished with mortar or other materials so as to prevent concrete dust.
• Provision for cutting the necessary openings and joists. Entrance
width: JJ
• Voltage fluctuation shall be within a range of +5% to -10%.
JJ

• Separate beams, when the hoistway dimensions markedly exceed the specifications, and intermediate beams when two or more elevators are installed.
• All other work related to building construction.
• The power-receiving panel and the electrical wiring for illumination, plus the power from them to the electrical room. Ordering Information
• The laying of conduits and wiring between the elevator pit and the terminating point for the devices installed outside the hoistway, Please include the following information when ordering or requesting estimates:
such as the emergency bell, intercom, monitoring and security devices, etc. • The desired number of units, speed and loading capacity.
• The power consumed in installation work and test operations. • The number of stops or number of floors to be served.
• The test provision and subsequent alteration as required, and eventual removal of the scaffolding as required by the elevator contractor, • The total elevator travel and each floor-to-floor height.
and any other protection of the work as may be required during the process. • Operation system.
• The provision of a suitable, locked space for the storage of elevator equipment and tools during elevator installation. • Selected design and size of car.
• The security system, such as a card reader, connected to Mitsubishi Electric’s elevator controller, when supplied by the building owner or general contractor. • Entrance design.
* Work responsibilities in installation and construction shall be determined according to local laws. Please consult our local agents for details. • Signal equipment.
• A sketch of the part of the building where the elevators are to be installed.
• The voltage, number of phases, and frequency of the power source for the motor and lighting.
17 18

You might also like