chirex® chiral columns

ORDERING INFORMATION
5 μm Starter™ Columns (mm)
Preparative Columns and Bulk Media are available in 15 and 30 μm
Chirex Phase Bond Linkage 50 x 4.6
particle sizes. Call for information on pricing and availability. Detailed
Phase Description Type Type
notes on Care and Use, as well as performance testing, are provided
I I I I
3001 (R)-PGLY and DNB Covalent Amide 00B-3001-E0 with each column.
3010 (S)-VAL and DNAn Covalent Urea 00B-3010-E0
3011 (S)-LEU and DNAn Covalent Urea 00B-3011-E0
3014 (S)-VAL and (R)-NEA Covalent Urea 00B-3014-E0 See p. 88 for Chiral Column Performance Check Standards.
3018 (S)-PRO and (R)-NEA Covalent Urea 00B-3018-E0
3019 (S)-LEU and (S)-NEA Covalent Urea 00B-3019-E0
3020 (S)-LEU and (R)-NEA Covalent Urea 00B-3020-E0 See p. 90 for Chiral Method Development Kits.
3022 (S)-ICA and (R)-NEA Covalent Urea 00B-3022-E0
3005 (R)-NGLY and DNB Covalent Amide 00B-3005-E0
3126 (D)-Penicillamine Ion-Metal Lig Exchange 00B-3126-E0
See p. 345 for HPLC Column Chiller/Heater System (8-70 °C).
3012 (R)-PGLY and DNAn Covalent Urea 00B-3012-E0
HPLC

5 μm Analytical and Guard Columns (mm) Analytical Guards


Chirex Phase Bond Linkage 150 x 2.0 250 x 2.0 150 x 4.6 250 x 4.6 30 x 4.6
Chirex Chiral
& Columbus

Phase Description Type Type


I I I I I I
3001 (R)-PGLY and DNB Covalent Amide — 00G-3001-B0 00F-3001-E0 00G-3001-E0 03A-3001-E0
3010 (S)-VAL and DNAn Covalent Urea — — 00F-3010-E0 00G-3010-E0 03A-3010-E0
3011 (S)-LEU and DNAn Covalent Urea — — 00F-3011-E0 00G-3011-E0 03A-3011-E0
3012 (R)-PGLY and DNAn Covalent Urea — — 00F-3012-E0 00G-3012-E0 03A-3012-E0
3014 (S)-VAL and (R)-NEA Covalent Urea — 00G-3014-B0 — 00G-3014-E0 03A-3014-E0
3018 (S)-PRO and (R)-NEA Covalent Urea — — 00F-3018-E0 00G-3018-E0 03A-3018-E0
3019 (S)-LEU and (S)-NEA Covalent Urea — — 00F-3019-E0 00G-3019-E0 03A-3019-E0
3020 (S)-LEU and (R)-NEA Covalent Urea 00F-3020-B0 — 00F-3020-E0 00G-3020-E0 03A-3020-E0
3022 (S)-ICA and (R)-NEA Covalent Urea 00F-3022-B0 00G-3022-B0 00F-3022-E0 00G-3022-E0 03A-3022-E0


3005 (R)-NGLY and DNB Covalent Amide — 00G-3005-B0 00F-3005-E0 00G-3005-E0 03A-3005-E0

3126 (D)-Penicillamine Ion-Metal Lig Ex 00F-3126-B0 00G-3126-B0 00F-3126-E0 00G-3126-E0 03A-3126-E0

Columbus™
• For new methods, we recommend Gemini HPLC
columns p. 126

Material Characteristics
Packing Particle Pore Surface Carbon End
Material Shape/size (μm) size (Å) Area (m2/g) Load (%) Capping
Columbus C8 Spher. 5 110 375 13 Double
Columbus C18 Spher. 5 110 375 19 Double

SecurityGuard™ Analytical Cartridges require universal holder Part No.: KJO-4282


Ordering Information
5 μm Microbore and LC/MS Columns (mm) SecurityGuard™Cartridges
30 x 2.0 50 x 2.0 100 x 2.0 150 x 2.0 4 x 2.0 mm
Phases
/10pk
C8 I 00A-4187-B0 I 00B-4187-B0 I 00D-4187-B0 I — AJ0-4289
C18 00A-4108-B0 00B-4108-B0 00D-4108-B0 00F-4108-B0 AJ0-4286
for ID: 2.0 – 3.0 mm

5 μm Solvent Saving Columns (mm) SecurityGuard™Cartridges


50 x 3.2 100 x 3.2 150 x 3.2 250 x 3.2 4 x 3.0 mm
Phases
/10pk
C18 I 00B-4108-R0 I 00D-4108-R0 I 00F-4108-R0 I 00G-4108-R0 AJ0-4287
for ID: 3.2 – 8.0 mm
5 μm Analytical Columns (mm) SecurityGuard Cartridges ™

30 x 4.6 50 x 4.6 100 x 4.6 150 x 4.6 250 x 4.6 4 x 3.0 mm


Phases
/10pk
C8 I — I — I 00D-4187-E0 I 00F-4187-E0 I 00G-4187-E0 AJ0-4290
C18 00A-4108-E0 00B-4108-E0 00D-4108-E0 00F-4108-E0 00G-4108-E0 AJ0-4287
for ID: 3.2 – 8.0 mm

116 Phenomenex