Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Alfa Laval in brief

Alfa Laval is a leading global provider


of specialized products and engineer-
ing solutions.
Our equipment, systems and
services are dedicated to helping our
customers to optimize the perform-
ance of their processes. Time and
time again.
We help them heat, cool, separate
and transport products such as oil,
water, chemicals, beverages, food-
stuff, starch and pharmaceuticals.
Our worldwide organization works
closely with customers in almost
100 countries to help them stay ahead.
Customized heat transfer
For effective Comfort Heating and District Heating
How to contact Alfa Laval

Contact details for all countries are


continually updated on our website.
Please visit www.alfalaval.com to
access the information.

Literature code number


Market leadership – your assurance

heating
technology
Customers in more than 60 countries have made
Alfa Laval the world market leader in heat exchangers
and thermal solutions.

Over 60 years of dedicated research and develop-


ment in the field of heat exchangers, together with
field experience from some 500,000 heating instal-
lations around the world, are your assurance that
we have the solutions you are looking for. Wherever
you are – and whatever your particular needs.

Welcome to the world of Alfa Laval heating


technology.
A global organization dedicated to excellence

Global experience – always near you


Wherever you are, Alfa Laval is there for you – to answer all your questions and
help you optimize your applications. Your dedicated Alfa Laval team is also just
a phone call away from cutting-edge R&D and a global organization. We will
provide whatever support, service or application expertise you may need – from
the initial studies right through to installation and operation.

• Alfa Laval heat exchangers mean you have a free choice of energy sources – from oil,
• Alfa Laval heat exchangers maximize energy efficiency and provide 95% heat recovery.
natural gas, and surplus heat from waste incineration, industrial processes and drainage.
• Alfa Laval heat exchangers demonstrate the lowest thermal and mechanical fatigue on
This means you can optimize energy sources to minimize costs as prices change, and
the market, and are fully customizable to meet any need.
maximize environmental protection.

Thermal systems and district heating Experienced planning means Alfa Laval heat
projects are complex processes that superior logistics exchangers are avail-
able CE- and UL-
often need to be split into separate At Alfa Laval, we believe that most approved and certi-
projects over a longer period of time. deliveries should not merely be in time. fied by TÜV, Germany,
They should be just in time in order to Det Norske Veritas,
Planning ahead save money and storage space for our Lloyds’ Register, Gost
standard of Russia,
When designing applications, plants customers. This is one of our major UDT of Poland, S.A.,
and substations, consideration must be strengths together with supplying and Swedish Authorities,
shown from the start for legislation and supporting the resources needed at Bureau Veritas,
Germanischer Lloyds
local regulations. Specifications from each different stage of a project.
Register of Shipping,
outside consultants or system owners plus a variety of local
must be taken into account. External From a single product to the approvals.
financing requires thorough preparatory complexity of a power plant
Almost 10,000
work. And projects can also be planned Close collaboration with the customer
Alfa Laval employees
and sized to enable working with local and every one of his partners and advis- in 140 countries serv-
contractors and businesses in order to ers is essential. We contribute actively ice and support our
maximize flexibility, create local jobs, and constructively from the very first customers all over
the world. Dedicated
and establish good relations. enquiry in order to help ensure you the
strategic service cen-
best possible solution – whether you ters for plate heat
We know because need a single product or a full-scale exchangers in eleven
we have been there project. countries support
locations on any con-
Alfa Laval customers always benefit tinent within 24 hours.
from our first hand experience from
hundreds of projects in different coun- The world of Alfa
tries and climates all over the world. Laval spans six conti-
nents. From Germany
You can gain invaluable knowledge via to South Africa, the
our Global Team and their connections USA to Australia, and
with a network of heating plants, district Brazil to South Korea.
heating companies and commercial
The introduction of
building owners. The Alfa Laval Global the Alfa Laval brazed
Team can also provide information heat exchanger in the
about investors, consultants, contrac- 1970s revolutionized
the design of district
tors and local installers.
heating modules.
Since then, Alfa Laval
R&D has been adding
Alfa Laval has 20 R&D centers around the world working closely new designs and
together with 35 production centers and the Alfa Laval Global products on a regular
team to address specific market demands and customer needs. basis.

5 Alfa Laval Heat Technology


Local needs and local solutions

Local presence – always there for you


Our future depends on the future of our customers. In a world of constant
change, it can be comforting to know that some essentials will remain the same.
One such essential is the local presence of Alfa Laval and our ability to support,
service and recondition any product in a comfort or district heating system that
has been supplied, delivered or installed by us.

We are always part of the future of our customers.

Many of our customers are engaged in Local needs require local response We also work together with our distrib- Leveraging local energy sources tions for coming stages. This meticu- Always close by
building a modern infrastructure based Globalization is an obligation – the utors and system builders to provide The availability of local energy is an lous process is even more critical when Alfa Laval is represented in all countries
on proven, effective and sophisticated obligation to adapt global experience and run software for design and func- important cost parameter. By using external financing and approval need by local sales consultants, and a net-
technology. This calls for customized to meet local needs. tionality testing, early simulations and heat exchangers from Alfa Laval, you to be obtained. work of regional authorized distributors
design to meet specifications that estimates of maintenance costs, and can choose one or several of a wide is responsible for serving our customers
address local conditions and specific Your Alfa Laval Support Team is fully if needed, test setups. We also offer variety of energy sources in order to At first sight it may seem daunting, at all times.
needs. equipped to meet any project require- on-site training, education, detailed maximize economic benefits and but it is part of our global experience
ment from day one with fast answers manuals in a number of languages, minimize environmental impact. and everyday work. All of our authorized distributors and
Others are expanding current plant and timely suggestions for improve- preventative maintenance support to sales consultants are able to perform
or designing next generation systems. ments. These are the success factors ensure maximum uptime, and – above Global expertise for local projects Full documentation dimensioning of heat exchangers based
This means analyzing the application that lead to a rewarding, long-term all – a local presence at any time and District heating system projects typically We provide documentation and speci- on application, heat load and available
benefits that new technology has to customer-supplier relationship. in any place. span a five-year period. These projects fications for investors local authorities, space, and provide installation guide-
offer, locating opportunities for even are complex processes that are often architects, consultants or other con- lines together with full price details.
faster return on investment, ensuring split up into several stages, each of tractors on a need-to-know basis. Many distributors also provide service
lower than ever Total Cost of Ownership, which is initiated by a pilot project, and And we can customize on request and maintenance on a local basis.
and reducing environmental impact. minutely documented as a basis for throughout the project – even down
improvements and refining specifica- to details such as color and shape.

Alfa Laval solutions and support span the The Heat Exchanger
entire process – from the main heat supply acts like a trans-
plant, through substations and heat exchang- former between the
ers to peripheral equipment in thermal sta- high-pressure network
tions serving end-user buildings. and a low-pressure
domestic system.
District heating typically relies on more than
one energy source. Alfa Laval gives you a This means increased
free choice between oil, natural gas, and sur- safety and reduced
plus heat from waste incineration, industrial investment costs as
processes and drainage. This means you can domestic systems
optimize energy sources to minimize costs can be designed for
as prices change, and maximize environmen- lower pressure.
tal protection.
The picture is of
If you should need a vital replacement part, three AlfaRex units
all you have to do is call your Alfa Laval rep- at the District Heat-
resentative. He can locate the nearest stocks ing Works of Jelenia
on the computer and usually arrange for Gora, Poland.
shipment within 24 hours, thus minimizing Total output: 7 Mw.
any downtime.

6 Alfa Laval Heat Technology Alfa Laval Heat Technology 7


A full range of globally proven heat exchangers

Power in products and performance


Alfa Laval has a full range of heat exchangers catering for every need, however
large or small. Alfa Laval is your assurance of quality in terms of compactness,
ease of installation, low maintenance costs, high energy efficiency, confidence
and flexibility. In other words, reliable operation, unsurpassed operating life
span, fast return on investment and low cost of ownership.

The AlfaRex Brazed heat exchangers Gasketed heat exchangers Steam heat exchangers
• Customized specifications • High energy efficiency • High flexibility • Minimal steam consumption
• Fast return-on-investment • Extreme compactness • Built for long lifetime • Easy-to-change capacity

AlfaRex – smooth and powerful show that the AlfaRex is superior to Brazed Heat Exchanger Intensive product development at volume that means fast response, and Steam Heat Exchanger – specially
for fast return on investment other welded constructions. – for normal heavy duty service Alfa Laval has led to a long line of new the tap water heater that is simple to designed for industrial steam
The plates in the AlfaRex are made The principle behind the brazed heat and improved BHE designs. This means regulate and provides instant hot water. The TS-M series represents the new
from corrosion-free, laser-welded mate- The AlfaRex is available in two different exchanger PHE’s involves using copper that you can choose from a wide selec- generation of steam heat exchangers.
rials with extremely smooth and strong frame and plate sizes. The AlfaRex to braze the stainless steel plates tion of Alfa Laval BHEs ranging in out- Gasketed Plate Heat Exchanger The unique geometry and strength of
seams. The plate package and pres- can be optimized to meet any cus- together, thus avoiding the need for put from 10 kW to 5 MW – enough to This type of heat exchanger uses a the stainless-steel plates, special gas-
sure-retaining frame provides a strong tomized specifications by adjusting gaskets and a pressure-retaining ves- heat as many as 1,000 apartments. gasket between the plates to direct kets that withstand temperatures up
and elastic construction that tolerates the size of the plate package. This sel. Brazed heat exchangers can toler- the water into the correct channels. to 180˚C (356˚F), and the robust heat
high loads and offers maximum protec- means more efficient operation and ate higher temperatures and pressures. Alfa Laval BHEs are designed to The number of plates is determined exchanger frame, deliver operational
tion against material exhaustion and enhanced performance for fast return- withstand temperatures of 170˚C and by a combination of heat load, pressure performance and economy unmatched
leakage. Extreme exhaustion tests of-investment. pressures of at least 16 bars that are drop and temperature settings. The by either shell-and-tube heat exchangers
common in district heating networks. corrugation causes a strong turbulence or conventional plate heat exchangers.
End-users appreciate the small hold-up that maximizes heat transfer efficiency.
A typical AlfaRex installation takes up only The design of Alfa Laval heat exchanger
one-sixth of the floor space and is only one- provides for fast and straightforward CIP
sixth the weight of a comparable shell- and (cleaning in place), easy maintenance and
tube heat exchanger with a lower capacity. long service intervals.
A plate Heat Exchanger is extremely efficient
with a heat transfer efficiency of more than
95 per cent. It also instantly heats domestic
water without any losses, and without any
need for a large accumulator tank.

8 Alfa Laval Heat Technology Alfa Laval Heat Technology 9


From the heatplant to the tap From the heatplant to the tap

Heat applications Substations


District heating is an environmentally friendly and reliable method of Heat exchangers from Alfa Laval are the most reliable solution for
delivering comfort heating to buildings and dwellings. Owing to differ- substations. There is an option for every need, whether you are pro-
ences in pressure and temperature, the main network and the end- viding heat for domestic tap water and the space heating system in
user system are not directly connected. Heat exchangers play a a building with 500 apartments, or need a small-scale solution spe-
major role in enabling efficient heat transfer between the two systems cially designed for a single dwelling.
in order to deliver hot water and heating to end-users.

District heating Traditional heating

3.
4.

2.

1. 2. 3. 4. 1. 5.

1. Hot water is obtained 2. Water circulates in 3. On arrival, the heat using a heat space heating. Floor 4. The returning water 1. Hot water is heated space heating. Tap perature of the return the boiler to a heat 4. Solar panels provide a swimming pool.
from a heat gener- the district heating from the district exchanger that is heating is also a temperature (blue- up to 90°C (194°F) water is heated by water (blue channels) exchanger with a an alternative or Here, a titanium
ating plant, or in the network at high pres- heating network is correctly dimen- common application. line) normally varies by the boiler, whose transferring heat via can be an important temperature control supplemental energy plate heat exchanger
form of surplus heat sure and at tempera- transferred to the sioned for the avail- The return water between 40–70˚C capacity varies a heat exchanger to factor in protecting device. In many source. will prevent chlori-
from a power station. tures ranging from internal heating sys- able space, and for (blue channels) is (104–158˚C). depending on the the tap water system the boiler. cases, however, the 5. Hot water can also nated or salt water
Heat is transferred 100 to 150°C (212 to tem which operates the required heat normally between required heat load. where water at a 3. Floor heating temperature differ- be circulated to from coming into
from the hot water to 302°F). This water at a lower pressure load. The main appli- 40 and 70°C (104 2. The hot water is lower temperature, requires a water tem- ence can be accom- another heat contact with the
the district heating delivers heat to build- and temperature. cations are hot water and 158°F). circulated directly normally between perature of about plished using a exchanger in order main system, thus
network via heat ings and dwellings This is accomplished from the tap and through the heating 50 and 60ºC 35°C (95°F). This can 3-way valve in which to perform other eliminating the risk
exchangers. connected to the sys- system (red chan- (122–140°F), is be obtained by circu- return water is mixed heating applications of corrosion.
tem (red channels). nels) to provide required. The tem- lating hot water from with heated water. such as heating up

10 Alfa Laval Heat Technology Alfa Laval Heat Technology 11


What the customers say References

Around the world


No two customers are ever the same. But most customers agree Denmark the Russian Government, Moscow
No more unscheduled downtime City Hall, and the Duma. It also serves
about why they prefer Alfa Laval. For some a compact, high-per- Metro Therm in Denmark has installed in the unique Christ the Surveyor
formance solution is essential. For others flexibility, reliability and Alfa Laval brazed plate heat exchangers Cathedral, in The International Opera
(BHEs) in its smaller tank modules för School, in the stadium of Luzhniki
heating speed are the vital factors. All value their close cooperation district heating and in oil and gas – one of the biggest in Europe – as
with Alfa Laval engineers in the field. It all boils down to rapid return combu boilers. They offer a wide range well as in the Moscow Metro, the
of solutions for providing hot water Pushkin Art Museum, the Zoo, banks
on investment and low total cost of ownership. from electric heating, district heating, and hotels, and large department stores.
central heating and alternative heat
sources such as solar energy. To meet The extreme efficiency and reliability
the demand the company has factories of Alfa Laval heat-transfer equipment
in Denmark, Norway and Poland. have considerably reduced operating
costs and downtime, demanding a
South Korea Metro Therm has been integrating Alfa minimum of effort and money to keep
Excess steam turned into profits Laval components into its own system it running.
Han Wha Energy Co, located in Inchon since Alfa Laval first introduced the
just outside Seoul, is one of very few brazed heat exchanger in the late 1970s. Alfa Laval’s plate heat exchangers are – “We are proud of the high level of quality,
private electricity power stations in South also widely used as the key element in design and service we give our customers and
we look for the same qualities in our suppliers.
Korea. This GTCC plant consists of heating modules manufactured by our Alfa Laval provides both the technology and the
four generator units with a total capacity Russia Russian partners. In the Siberian city of high quality we need to be competitive”, says
of 1650 Mw delivering supplementary From Moscow to Novosibirsk Novosibirsk, for example, more than Henrik Jensen, purchaser at Metro Therm.
electric power to the state-owned Moscow has always been the Russian 350 plate heat exchangers have been
Korean Electric Power Cooperation. center where new scientific inventions installed during the last five years,
meet industrial trends and spring to mainly in heating modules.
Han Wha Energy Co decided to life. This spirit of innovation was the
streamline its operations by utilizing soil in which the seed of cooperation The implementation of uniform equip-
the surplus heat from their electricity between Alfa Laval and the Russian ment from a single supplier such as
production by acquiring an AlfaRex capital’s authorities and organizations Alfa Laval provides the opportunity to
TM10 in 1999. Han Wha Energy now was sown. try new approaches in relationships
utilizes surplus heat from steam that among cities in the region, and the
previously went unused. Steam enters The first Alfa Laval heat exchangers ability to solve problems in heat supply
the heat exchanger at 200˚C and is were installed in Moscow already in at minimal cost.
condensed, releasing its heat to water the 1970s and have since functioned
that is used to heat the facility during smoothly in local authority district heat- Since the mid 1990s, Alfa Laval has
winter. In spite of the AlfaRex unit’s ing systems, and in industrial and local been able to offer locally produced
compact size, its capacity is impres- authority ventilation, air-conditioning components to Russian customers.
sive, heating 31.5 cubic meters of and refrigeration applications. All equipment produced by Alfa Laval
water an hour from 10 to 100˚C. Potok is fully certified in accordance
Today, more than 7,000 Alfa Laval heat with Russian standards, making the
“At first we considered an ordinary shell- exchangers are installed in Moscow. decision procedure even easier for
and tube solution for this purpose”, says Main customers include design bureaus, potential customers.
Mr. Soon-Bok Kim, General Manager South Korean Han Wha Energy construction and maintenance compa-
of Han Wha’s operations department. Co., one of very few private nies building and supporting industrial At the beginning of 1999, a major mile-
“But space was at a premium and electricity power stations in and civil objects, offices and residential stone in the history of thermal plant in
reliability was key, so we contacted Alfa South Korea. Space limitations areas, hospitals, schools and kinder- Russia was passed with the ISO 9002
Laval for an alternative suggestion. and high reliability requirements gartens. Alfa Laval has helped to make certification of the leading-edge quality
When we took a closer look at size, made the all laser-welded AlfaRex the dream of a new standard of living control system installed at Alfa Laval
reliability, cost, and ease of mainte- TM10 a natural choice for turn- come true for the citizens of Moscow. Potok. Production at the Alfa Laval
nance, the choice was simple. We are ing surplus steam into profits. plant in Potok is constantly growing
satisfied with our AlfaRex unit and its Alfa Laval heating equipment can be with current output at some 3,000
trouble-free operation without any need found in the Armory Chamber of the PHEs a year.
for maintenance.” Moscow Kremlin, in the building of

12 Alfa Laval Heat Technology Alfa Laval Heat Technology 13


References

Germany “It’s an easy task on paper”, says Italy its heat is transferred to the heating “Our oldest Alfa Laval plate heat
Speed and flexibility Ludger Hentschel. “You warm water Reliability and efficiency ventilation system at 70°C (158°F). exchanger is more than 20 years old,
Staudinger Kraftwerk is a member if the from 25 to 95˚C using steam at 120˚C Montegrotto is a peaceful region in and is still working perfectly,” says
E.on Group, one of Germany’s leading under a 9 bar working pressure. The the Euganean Hills in north-eastern Tap water requires a lower temperature Mr. Martelli. “We have never had any
industrial groups with over 200.000 stop-and-go nature of operations Italy, famous for its hot springs. Three of about 65°C (149°F). The heat for problems and it has never needed
employees and sales for the year of means, however, that the heat of the most prestigious hotels in the this application is extracted by a third repairs.”
some 76 billion euros. The power facil- exchanger is often exposed to uneven region, the Neroniane, Commodore heat exchanger, after which the water
ity is in the 2000 Mw class, and runs loads. Earlier, we used a gasketed and Marconi, use geothermal water as proceeds to the fourth heat exchanger Reliability is the keyword
on a combination of coal and gas. plate heat exchanger from another their primary source of heating energy. where it is transferred to the floor The three hotels are open 24 hours
manufacturer, but gasket changes heating system at a temperature of a day, 365 days a year. Many guests
“Electricity demand varies from day were both costly and time-consuming. “We have many different heating appli- 40°C (104°F). start therapeutic treatment as early as
to day”, says Ludger Hentschel, sys- cations ranging from radiators, ventila- 4 o’clock in the morning, while others
tem engineer at Staudinger Kraftwerk. “The AlfaRex Heat Exchanger is perfect tion, tap water, floor heating and swim- Finally, the fifth heat exchanger utilizes are still active late at night. This means
“That means we have to be flexible for this application because of its flexible ming pools,” says Mr. Mario Martelli, the remaining heat from the geothermal that the three hotels are entirely
and ready to close down or start up construction that easily copes with the owner of the three hotels. water for the swimming pool where dependent on a reliable and efficient
the steam turbine at short notice. pressure and temperature variations. a heating temperature of between heating system in order to maintain
One problem is that the start-up Another advantage, of course, is that it “The AlfaRex performs perfectly in spite of A string of applications 30 and 35°C (86 and 95°F) is needed. their high standards of service at all
steam is not good enough to drive is almost completely maintenance-free. stop-and-go processes, uneven loads and At each hotel, geothermal water at times.
the turbine.” A tube Heat Exchanger might also have variations in pressure and temperature.” 87°C (189°F) from depths down to High capacity and long life
Ludger Hentschel, system engineer.
done the job, but it would have taken 800 m is passed through a string “We have a total of 20 plate heat “Alfa Laval has never failed us,”
The water level in the boiler drops up at least ten times as much space”. of five different Alfa Laval heat exchangers at the three hotels, in a Mr. Martelli adds. “The benefits they
when steam is released. This means exchangers, serving a number of number of different sizes and capaci- offer us are reliability, efficiency, inno-
that more hot water has to be supplied separate applications with a temper- ties,” Mr. Martelli explains. “The heat vation and service. Together with their
from a special accumulator tank. ature drop at each one. exchangers employed are mainly local agent, Mr. Piero Bertin, Alfa Laval
Staudinger Kraftwerk uses an AlfaRex M6 and M6-M models, and plant provides solutions that address our
TM10 to heat this water. The first plate heat exchanger transfers capacity at the hotels ranges from specific needs, together with excellent
heat from the geothermic water to the 42,000 liters an hour (2,780 kW) at customer care and after sales service
radiator heating system at 75°C (167°F). the Hotel Commodore to 24,000 liters at all times.”
The same water then proceeds to a an hour (1,590 kW) at the Hotel
second plate heat exchanger where Neroniane.”

Staudinger Kraftwerk
in Germany invested
in an all laser-welded
AlfaRex plate heat
“Our mission is to build
exchanger in order
to obtain the neces-
value for our customers by
sary steam quality helping them to optimize
for the turbine as
fast as possible on processes and resources.”
start-up.

14 Alfa Laval Heat Technology

You might also like