50PG20/42PG20 POWER SUPPLY

TURN ON COMMANDS FROM MAIN PWB

M5V
M5V (DC Voltage)
Reg To Y-SUS, then to
7
Control PWB.
In Stand-By In Run (Relay On) 8
AC In Primary side is Primary side is
90V 370V Vs Vs/Va (DC Voltage)
1 Stand
5 12V/16V 9
Reg

By 5V Reg Regulators Va To Y-SUS, Z-SUS


Reg Va routed to X-PWBs

AC Stand 10
Det. By 5V 12V 16V
See
Note1 NOTE 1:
5V Relay M5V Vs 50PG20 has 12V and 16V to Main at turn on.
Det. On On On 42PG20 only has 16V.

3 2 5 5 6 6 7 9

12V 16V
Video Audio
Turns on 5V
Red LED Reg
2

Relay At point 3 TV is in
Turns on On Stand-By state.
5 Energy Star compliant.
Green LED
5 Less than 1 Watt
AC Both LEDs On
Det. Looks Amber

Resets Microprocessor 7
Main Board or 9
BCM
3

Power Remote
Button Or Key
4

You might also like