PROPOSED 2 STOREY RESIDENTIAL

STRUCTURAL DESIGN

PREPARED BY:

ENGR. EDUARDO B. LERON JR


CIVIL ENGINEER
REG. NO. :
PTR #:
PLACE ISSUED: VALENZUELA CITY
PROPOSED 2 STOREY RESIDENTIAL

STRUCTURAL ANALYSIS

LOAD COMPUTATION:

Deadload kPA
Concrete For Slab 24
Thickness of Slab 0.15
Thickness of wall 0.2
Wall Full Grout 3.59
Slab 3.6
Flooring 1.1
Wall two face plaster 1.198
Movable Partition 1
Ceilng 0.72
Truss 17.925
Purlins 0
Meps 0.1
Roofing 0.24

Ground MemberLoad
wall 1.198
Ground Floorload 5.7
Roof Memberload 7.654275

Zone 4
WindSpeed 250

Dead +A15:F43Load
DeadLoad Value Truss
Roof KPA Input
Truss 0.12 0.336
Purlins 0.12 0.06564
Ceiling 0.72 2.016
Meps 0.1 0.28
Liveload
Roof 0.6 1.68
Wind Load
get a value
10% of horizontal Span 0.8
0.4H 2.06
Choose Smallest
But not less than
4% of horizontal span of
building 0.32
or 0.9

a 0.9

Truss Wind Pressure


Truss Effective Area 10.71
Zone
1 2 3
Direct 0.67 0.67
Sunction -2.25 -2.25
Adjusted Wind Pressure (use
in Staad)
1 2 3
Direct 1.876 1.876
Sunction -6.3 -6.3

Purlin Wind Pressure


Purlin Effective Area 1.5316
Zone
1 2 3
Direct 0.81 0.81
Sunction 2.05 -3.28
Adjusted Wind Pressure (use in Staad)
1 2 3
0.4430
Direct 7 0.44307 0
1.1213
Sunction 5 -1.79416 0
Truss Spacing 2.8
End Truss Distance 2.8
Purlin Spacing 0.547
End Purlin Spacing 0.547
Horizontal Span of
Roof 8
Elevation of Roof 5.6
Elevation of Apec 4.7
Roofmeanheight 5.15
MODEL
FOUNDATION PLAN
FOOTING DETAILS
2ND FLOOR FRAMING PLAN

ROOF FRAMING STAIR DETAILS