IEC 62053-22 Class 0.5S Large, Backlit Dot-Matrix LCD with
True RMS Measurements Wide Viewing Angle THD with 31 Ind. Harmonics I/O Expansion Capabilities K-Factor, Crest Factor and TDD RS-485 Port with Modbus RTU Unbalance & Phase Angles IP54 Enclosure with No Openings Demands and Peak Demands Standard Tropicalization Max/Min Log with Timestamp Industrial Grade Components Multi-Tariff TOU Extended Temperature Range 12 Monthly Energy Log & SOE Log Extended Warranty
Designed For Reliability Manufactured To Last
PMC-53A Intelligent Multifunction Meter Ease of use Large, backlit, Dot-Matrix LCD display with wide viewing angle Easy to navigate with an intuitive user interface kWh and kvarh LED pulse outputs for accuracy testing LED indicator for communication activities Password-protected setup via front panel or free PMC Setup software Easy installation with mounting clips, no tools required Setpoints 9 user programmable setpoints with extensive list of monitoring parameters including Voltage, Current, Power and THD, … etc. Configurable thresholds, time delays and DO triggers SOE Log 64 events time-stamped to ±1ms resolution Setup changes, Setpoint and DI status changes and DO operations The PMC-53A Intelligent Multifunction Meter is CET’s latest offer for the Max/Min Log low-cost digital power/energy metering market. Housed in a standard DIN Max/Min Log with Timestamp for real-time measurements such as form factor measuring 96x96x74mm, it is perfectly suited for industrial, Voltage, Current, In, I4, Freq., kW, kvar, kVA, PF, Unbalance, K-factor, commercial and utility applications. The PMC-53A features quality Crest Factor and THD. construction, multifunction measurements and a large, backlit, Dot-Matrix Configurable for This Month/Last Month or Before/Since Last Reset LCD that is easy to navigate and user friendly. Compliance with the IEC Diagnostics 62053-22 Class 0.5S Standard, it is a cost effective replacement for analog Frequency Out-of-Range, Loss of Voltage / Current instrumentation that is capable of displaying 4 measurements at once. It kW Direction per phase and Total, Possible incorrect CT Polarity optionally provides I4 input for Neutral Current measurement, a second Incorrect V & I Phase Sequence, RS485 port, four Digital Inputs for status monitoring, two Relay Outputs for control and alarm applications as well as other I/O options for different Communications applications. Optically isolated RS485 port at max. 38,400 bps Optional 2nd RS485 port Typical Applications Standard Modbus RTU Industrial, Commercial and Utility Substation Metering System Integration Building, Factory and Process Automation Supported by CET’s PecStar® iEMS and iEEM Sub-metering and Cost Allocation Easy integration into 3rd-party Energy Management, Automation or Energy Management and Power Quality Monitoring SCADA systems via Modbus RTU
Features Summary Inputs and Outputs
Basic Measurements Digital Inputs (Optional) VLN, VLL per phase and Average 4 channels, volts free dry contact, 24VDC internally wetted Current per phase and Average with calculated Neutral 1000Hz sampling kW, kvar, kVA, PF per phase and Total External status monitoring with programmable debounce kWh, kvarh Import / Export / Net / Total and kVAh Total Pulse counting with programmable weight for each channel for collecting Frequency WAGES (Water, Air, Gas, Electricity, Steam) information Optional I4 measurements Digital Outputs (Optional) Enhanced Measurements 2 Form A mechanical relays for alarming and general purpose control THD, TOHD, TEHD and Individual Harmonics up to 31st 2 Solid State Pulse Outputs for kWh and kvarh pulsing TDD, K-Factor, Crest Factor and Displacement PF V and I Unbalance and Phase Angles Expansion Modules Demands, Predicted Demands and Peak Demands for kW Total, kvar Total, The PMC-53A supports two optional, factory-installed modules that provide kVA Total and per phase Current with Timestamp users with additional flexibility. Max/Min Log for real-time measurements Expansion Module A Two TOU schedules, each providing I4 Input o 12 Seasons 2nd RS485 port o 20 Daily Profiles, each with 12 Periods in 15-minute interval o 90 Holidays or Alternate Days Expansion Module B o 8 Tariffs, each providing the following information 2xDigital Inputs and 2xRelay Outputs o kWh/kvarh Import/Export, kVAh o kW/kvar/kVA Max. Demands 2xRTD Input (PT100 sensor not included) 12 monthly recording of kWh/kvarh Import/Export/Total/Net, kVAh, 1xAI and 1xAO (0/4-20mA) kvarh Q1-Q4 as well as kWh/kvarh Import/Export and kVAh per Tariff
Designed For Reliability Manufactured To Last
PMC-53A Intelligent Multifunction Meter Accuracy Standards of Compliance Parameters Accuracy Resolution Safety Requirements Voltage ±0.2% reading 0.1V CE LVD 2014 / 35 / EU EN61010-1 Edition 3 Current ±0.2% reading 0.001A Electrical safety in low voltage IEC 61557-12: 2008 I4 (measurement) 1.0% 0.001A distribution systems up to 1000Vac kW, kVA IEC 62053-22 Class 0.5S 0.001k and 1500 Vdc kWh, kVAh IEC 62053-22 Class 0.5S 0.1kXh Insulation IEC 60255-5-2000 kvar / kvarh IEC 62053-21 Class 2 0.001k / 0.1kvarh Dielectric test: 2kV @ 1 minute P.F. ±1.0% 0.001 Insulation resistance: >100MΩ Frequency ±0.02 Hz 0.01Hz Impulse voltage: 6kV, 1.2/50µs THD IEC 61000-4-7 Class B 0.01% Electromagnetic Compatibility K-Factor IEC 61000-4-7 Class B 0.1 Phase angles ±1° 0.1° CE EMC Directive 2014 / 30 / EU (EN 61326: 2013) Immunity Tests Technical Specifications Electrostatic discharge IEC 61000-4-2: 2001 Level IV Radiated fields IEC 61000-4-3: 2002 (10 V/m) Voltage Inputs (V1, V2, V3, VN) Standard Un 400VLN/690VLL Fast transients IEC 61000-4-4: 2004 Level III Range 10V to 1.2Un Surges IEC 61000-4-5: 2005 Level IV Overload 1.2xUn continuous, 2xUn for 1s Conducted disturbances IEC 61000-4-6: 2006 Level III Burden <0.02VA per phase Magnetic Fields IEC 61000-4-8: 2001 Level IV Measurement Category CAT III up to 600VLL Oscillatory waves IEC 61000-4-12: 2006 Level III Frequency 45-65Hz Current Inputs (I11, I12, I21, I22, I31, I32) Radio Disturbances CISPR 22:2006, Level B Standard In 5A Emission Tests Range 0.1% to 200% In Limits and methods of measurement Starting Current 0.1% In of electromagnetic disturbance Overload 2xIn continuous, 20xIn for 1s EN 55011: 2009 (CISPR 11) characteristics of industrial, scientific Measurement Category CAT III up to 600VLL Burden <0.15VA per phase and medical (ISM) radio-frequency Power Supply (L+, N-, GND) equipment Standard 95-250VAC/DC, ±10%, 47-440Hz Limits and methods of measurement EN 55022: 2006+A1: 2007 Burden <2W of radio disturbance characteristics of (CISPR 22) Overvoltage Category CAT III up to 300VLN information technology equipment Digital Inputs (DI1, DI2, DI3, DI4, DIC) Limits for harmonic current emissions Type Dry contact, 24VDC internally wetted for equipment with rated current ≤16 EN 61000-3-2: 2006+A1: 2009 Sampling 1000Hz A Hysteresis 40ms minimum Limitation of voltage fluctuations and Digital Outputs (DO11, DO12, DO21, DO22) Type Form A Mechanical Relay flicker in low-voltage supply systems EN 61000-3-3: 2006 Loading 5A @ 250VAC or 30VDC for equipment with rated current ≤16 Pulse Outputs (kWh, kvarh) A Type Form A Solid State Relay Emission standard for residential, Isolation Optical commercial and light-industrial EN 61000-6-3: 2007 Max. Load Voltage 80V environments Max. Forward Current 50mA Electromagnetic Emission Tests for Installation Torque Measuring Relays and Protection IEC 60255-25: 2000 Voltage / Current Inputs 1.3 N.m Power Supply, RS485, I/O 0.5 N.m Equipment Environmental Conditions Mechanical Tests Operating Temp. -25°C to 70°C Response IEC 60255-21-1:1998 Level I Vibration Test Storage Temp. -40°C to 85°C Endurance IEC 60255-21-1:1998 Level I Humidity 5% to 95% non-condensing Response IEC 60255-21-2:1998 Level I Atmospheric Pressure 70 kPa to 106 kPa Shock Test Endurance IEC 60255-21-2:1998 Level I Mechanical Characteristics Panel Cutout 92x92 mm (3.62”x3.62”) Bump Test IEC 60255-21-2:1998 Level I Unit Dimensions 96x96x74 mm IP Rating 54 (Front Panel), 30 (Body) Shipping Weight TBD Shipping Dimensions TBD
Designed For Reliability Manufactured To Last
PMC-53A Intelligent Multifunction Meter Device View and Dimensions Ordering Information
Your Local Representative
Ceiec Electric Technology Inc.
A: 8/F, WestSide, Building 201, Terra Industrial & Tradepark Che Gong Miao, Shenzhen, Guangdong, P. R. China 518040 T: +86.755.8341.5187 F: +86.755.8341.0291 E: sales@cet-global.com W: www.cet-global.com Revision Date: August 3, 2016