Professional Documents
Culture Documents
Aircraft Maintenance Manual: Refer To Figure 605
Aircraft Maintenance Manual: Refer To Figure 605
**ON A/C 4006, 4009−4010, 4012, 4015, 4019−4029, 4033−4035 Pre SB84−34−20
TASK 05−20−00−210−805
General Visual Inspection of the Connectors in the AHRS HIRF Enclosure (MRB#052000−307)
1. General
A. The maintenance procedure that follows is for the general visual inspection of the connectors
related to the attitude heading reference system (AHRS) units. The AHRS units are installed in a
HIRF (Lightning/High Intensity Radiated Fields) enclosure below the floor in the passenger
compartment.
3. Job Set−Up
Subtask 05−20−00−010−008
REFERENCE DESIGNATION
133JZ Floor Panel
B. Remove the cover (1) from the HIRF enclosure (2) as follows:
(1) Remove the screws (3) and washers (4) from the cover (1) and the enclosure (2).
(2) Remove the cover (1) of the box (2).
4. Procedure
Refer to Figure 605.
Subtask 05−20−00−210−015
A. Use a light and mirror to do a general visual inspection of the AHRS connectors (5) in the HIRF
enclosure (2) as follows:
(1) Look at the connectors on the AHRS units(6).
(2) Make sure that all connectors and backshells are correctly installed.
(3) Make sure that the connectors are in a good condition and are not damaged.
5. Close Out
Subtask 05−20−00−410−006
REFERENCE DESIGNATION
133JZ Floor Panel
Subtask 05−20−00−941−017
C. Remove all tools, equipment and unwanted materials from the work area.
X388.00
X373.15
LEGEND
1. Cover.
2. HIRF enclosure.
3. Screw.
4. Washer.
5. AHRS connectors.
6. AHRS units.
4
1
6
Y9.25
Y0.00
brat14a01.dg, gg, 20/10/03